• Title/Summary/Keyword: sandpapers

Search Result 14, Processing Time 0.027 seconds

A Study on Tactile Visuality Using Sandpapers (연마지를 이용한 촉각적 시각에 관한 연구)

  • Lee, Eun-Suk;Kim, Ji-Sun;Oh, Han-Byeol;Baek, Jin-Young;Jun, Jae-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1424-1430
    • /
    • 2017
  • Human senses have been studied widely. Many studied are being actively conducted to analyze correlations between two or more different senses. Among them, research on tactile visuality where a subject can indirectly experience visual sensation through tactile elements is also progressing in various fields. In this study, we analyzed color information by having subjects perceive sandpapers with different roughness through tactile sense, then having them choose a color that is reminiscent of the tactile sensation. Unlike existing tactile-visuality studies allowing the perception of indirect visual sense by using tactile sense, this study shows that it is possible to analyze with quantitative value by representing visual image perceived by tactile sense as a color. This study will contribute to emotional evaluation research that combines two or more of the senses felt by humans, and especially is considered to be useful as basic data when conducting research about tactile visuality or auditory tactile sense.

SHEAR BOND STRENGTH OF ORTHODONTIC BONDING RESINS TO PORCELAIN; AN IN VITRO STUDY (도재에 대한 교정용 브라켓 접착 레진의 전단접착강도에 관한 연구)

  • Ko, Jin-Hwan;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.22 no.1
    • /
    • pp.43-65
    • /
    • 1992
  • Bonding orthodontic adhesive resins to glazed porcelain surface is not attainable. The aim of this investigation was to examine, in vitro, the effect of three methods of porcelain surface pretreatment on the shear bond strength of orthodontic adhesives, and to compare the shear strength of orthodontic bracket bonding to porcelain surface by the best results that to human enamel. Porcelain disks ($Ceramco^{(TM)}$ and $Vita^{(TM)}$) baked in the laboratory were roughened by sandpapers, #320, #600, #800, #1000 and #1200, and were pretreated with silane and dried at the various temperatures, room temperature, $50^{\circ}C$, $70^{\circ}C$ and $90^{\circ}C$, and were etched by 3% hydrofluoric acid solution for 1, 3, 5, 7, and 9 minutes, orthodontic adhesives (System $1+^{(TM)}$ and $Unite^{(TM)}$) were applied on them, and shear bond strengths were measured by Instron. The best results of pretreatment of each method were determined by the shear bond strengths. Again, porcelain disks were pretreated by the determined best results and human enamel were etched by 37% hydrofluoric acid solution, orthodontic brackets were bonded on them by the orthodontic adhesives, and the shear bond strengths were measured and compared between them. 1. Roughening porcelain surfaces with coarse sandpaper (#300) showed higher shear bond strength than that with finer sandpapers, but it $(22.44Kgf/cm^2)$ was distinguishably low compared to that from etched human enamel $(144.11Kgf/cm^2)$. 2. There were disparities in shear bond strengths upon the orthodontic resins, which was presumably related to the contents of fillers in orthodontic adhesive resins. Also there were disparities in shear bond strength upon the porcelains which had different composition. 3. Silane enhanced the shear bond strength of orthodontic resins to porcelain surfaces ($25.20Kgf/cm^2$ at $50^{\circ}C$), which was markedly low compared to that from etched human enamel. 4. Etched porcelain surface with 3% hydrofluoric acid solution for 1 to 9 minutes showed no difference in shear bonding strength of orthodontic adhesive resins. Shear bond strength from etched porcelain $(97.43-120.72Kgf/cm^2)$ were as high as clinically available, but low compared to that from etched human enamel. 5. Roughening with #300 sandpaper and etching by 3% hydrofluoric acid followed silane application on porcelain surface showed lower shear bond strength than etched human enamel, but were as high as clinically useful. 6. The results suggest that etching porcelain surface by 3% hydrofluoric acid solution might provide comparatively high shear bond strength as much as clinically favorable.

  • PDF

Reproducibility Prediction of Surface Roughness in Mold and Injected Parts through Polycarbonate Injection Molding (폴리카보네이트 사출성형에 따른 금형과 사출품에서 표면거칠기의 재현성 예측)

  • Hong, Su Yong;Kim, SungSu;Lee, Sang Sun;Lee, Ji Ho;Choi, Wong Jun;Kang, Myung Chang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.3
    • /
    • pp.131-137
    • /
    • 2017
  • In this study, we evaluated the surface roughness of mold and injected parts manufactured by polycarbonate (PC) injection molding. The mold surface was polished to produce six differentiated roughnesses with 12 areas using stones (#800, #1200), sandpapers (#800, #1200), and diamond compounds (#8000, #14000). Injected parts were created using 20mm/s injection speed, 80 bar holding pressure for 5 seconds, and $70^{\circ}C$ cooling water. Injected parts surface roughness (Sa) was measured randomly in 10 of 30 using an interferometer (NewView8000, zygo, USA). In the same way, mold surface was measured randomly 10 times on 12 polished areas. Surface roughness of molds and injected parts were compared, and a regression equation to predict mold surface roughness was proposed for specific injection molding parameters.

Effect of adhesive application method on repair bond strength of composite

  • Hee Kyeong Oh;Dong Hoon Shin
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.3
    • /
    • pp.32.1-32.10
    • /
    • 2021
  • Objectives: This study aimed to evaluate the effect of the application method of universal adhesives on the shear bond strength (SBS) of repaired composites, applied with different thicknesses. Materials and Methods: The 84 specimens (Filtek Z350 XT) were prepared, stored in distilled water for a week and thermocycled (5,000 cycles, 5℃ to 55℃). They were roughened using 400-grit sandpapers and etched with phosphoric acid. Then, specimens were equally divided into 2 groups; Single Bond Universal (SU) and Prime&Bond Universal (PB). Each group was subdivided into 3 subgroups according to application methods (n = 14); UC: 1 coat + uncuring, 1C: 1 coat + curing, 3C: 3 coats + curing. After storage of the repaired composite for 24 hours, specimens were subjected to the SBS test and the data were statistically analyzed by 2-way analysis of variance and independent t-tests. Specimens were examined with a stereomicroscope to analyze fracture mode and a scanning electron microscope to observe the interface. Results: Adhesive material was a significant factor (p = 0.001). Bond strengths with SU were higher than PB. The highest strength was obtained from the 1C group with SU. Bonding in multiple layers increased adhesive thicknesses, but there was no significant difference in SBS values (p = 0.255). Failure mode was predominantly cohesive in old composites. Conclusions: The application of an adequate bonding system plays an important role in repairing composite resin. SU showed higher SBS than PB and the additional layers increased the adhesive thickness without affecting SBS.

Evaluation of Scratch Characteristics of Diaphragm for Application of Hydrogen Compressor Parts

  • Sung-Jun Lee;Chang-Lae Kim
    • Tribology and Lubricants
    • /
    • v.39 no.5
    • /
    • pp.212-215
    • /
    • 2023
  • Diaphragm compressors play a crucial role in safely compressing large volumes of high-purity hydrogen gas without contamination or leakage, thereby ensuring quality and reliability. Diaphragm compressors use a thin, flat, triple-layered diaphragm plate that is subjected to repetitive piston pressure for compression. They are usually made of metallic materials such as stainless steel or Inconel owing to their high-pressure resistance. However, since they are consumable components, they fail due to fatigue from repetitive pressure and vibration stress. This study aims to evaluate the scratch characteristics of diaphragms in operational environments by conducting tests on three different samples: Inconel 718, AISI 301, and Teflon-coated AISI 301. The Inconel 718 sample underwent a polishing process, the AISI 301 sample used raw material, and the Teflon coating was applied to the AISI 301 substrate at a thickness of 50 ㎛. To assess the scratch resistance, reciprocating motion friction tests were performed using a tribometer, utilizing 220 and 2000 grit sandpapers as the counter materials. The results of the friction tests suggested that the Teflon-coated sample exhibited the lowest initial friction coefficient and consistently maintained the lowest average friction coefficient (0.13 and 0.11 with 220 and 2000 grit, respectively) throughout the test. Moreover, the Teflon-coated diaphragm showed minimal wear patterns, indicating superior scratch resistance than the Inconel 718 and AISI 301 samples. These findings suggest that Teflon coatings may offer an effective solution for enhancing scratch resistance in diaphragms, thereby improving compressor performance in high-pressure hydrogen applications.

Experimental analysis of vortical structures in a turbulent layer using a dynamic PIV technique (Dynamic PIV를 이용한 난류경계층 내부 와구조 거동의 실험적 분석)

  • Choi, Yong-Seok;Lee, Sang-Joon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.193-196
    • /
    • 2008
  • The vortical structures in a turbulent boundary layer (TBL) developed over a flat plate have been investigated experimentally. The flow conditions tested in this study were Re$_{\theta}$ = 3700, Re$_{\delta}$ = 11${\times}$105 and the shape factor H = 1.3. Instantaneous velocity fields in the streamwise-wall-normal planes were measured by using a dynamic PIV system. A trip-wire and sandpapers were placed behind the leading edge to promote the turbulent transition. 1000 velocity fields were obtained consecutively with a time interval of 1 millisecond. Streamwise u-velocity components were temporally averaged in the measuring plane. In addition, 2000 velocity fields were obtained randomly and ensemble-averaged to get the fully-developed turbulent characteristics. Profiles of the normalized u-component, turbulent intensities and Reynolds shear stress were evaluated. The structures of spanwise vortices were extracted from the instantaneous velocity fields by determining the swirling strength, ${\lambda}_{ci}$. The wall-normalized locations of vortices were temporally averaged in the measuring plane with respect to their rotational direction. The correlations between the temporally averaged u and the temporally averaged $y^+$ of vortices were evaluated. For the case of positive vortices, the correlation is not significant. However, the negative vortices show a strong negative correlation. The y-location of negative vortices tends to increase, as the averaged u decreases and vice versa. These findings indicate that the number of negative vortices in the outer layer increases during the outward bursting events.

  • PDF

Evaluation of Friction Properties between Geostrip/Sandpaper Interface (지오스트립/샌드페이퍼 계면에서의 마찰특성 평가)

  • Lim, Ji-Hye;Byun, Sung-Won;Jeon, Han-Yong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.4
    • /
    • pp.27-33
    • /
    • 2006
  • Frictional properties between geostrip and sand paper interface were estimated considering soil particle size also the friction coefficients and angles were determined with normal stress. Three kinds of geostrips of design strength 50, 70, 100 KN/m were used and 5 sandpapers of P100, P220, P320, P400, P600 were used also. Shear strength between geostrip and sand paper interface with design strength showed big difference and this is due to the uniform surface pattern of each geostrip when contact to sandpaper without regard to design strength. Shear strength of geostrip was increased with design strength and geostrips/P100 sandpaper interface showed the biggest value. Finally, all of geostrips showed the decrease phenomena of post-peak strength and this is due to the abrasion of geostrip surface by shear test.

  • PDF

THE ADAPTATION OF LIGHT CURED GLASS IONOMER CEMENTS TO TOOTH STRUCTURE (광중합형 글래스 아이오노머 시멘트의 치질접착에 관한 연구)

  • Hur, Seung-Myun;Cho, Young-Gon;Moon, Joo-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.489-504
    • /
    • 1996
  • The purpose of this study was to compare the adaptation to the tooth structure of five light cured glass ionomer cements (Fuji II LC. VariGlass VLC, Vitremer, Dyract and Geristore). Human, non-carious fifty extracted permanent premolars stored in normal saline were used. Class V cavity preparations were created on the buccal surfaces. The occlusal margin of each cavity was placed on the enamel and the gingival margin was placed on the cementum/dentin. The teeth were then distributed at random into five groups of 10 teeth each. Group 1: Fuji II LC, Group 2 : VariGlass VLC, Group 3 : Vitremer, Group 4: Dyract, Group 5 : Geristore. The prepared cavities were restored with one of the five light cured glass ionomer cements. The manipulation of each material was handled according to the manufacturer's instructions. All samples were placed in incubator of 100% relative humidity at $37^{\circ}C$ for 24 hours. The roots of the teeth were removed with the tapered fissure bur and the remaining crowns were sectioned buccolingually through the center of restorations. The cut interfaces were gradually hand polished on sandpapers from 300 up to 1200 grit. The adaptation at the tooth/cements interface was assessed by SEM (JSM-840A, JEOL Ltd.). The results of this study were as follows : 1. Group 2 revealed the best adaptation and groups 1, 4 and 5 revealed similar adaptation pattern to the cavity walls. Group 3 revealed the worst adaptation to the cavity walls. 2. Enamel margins showed better adaptation than dentin/cementum margins with each material except group 3. 3. The hybrid layers were observed between the glass ionomer cement and dentin in groups 2, 4 and 5.

  • PDF

A STUDY ON THE COLOR STABILITY OF RESIN MODIFIED GLASS IONOMERS (레진 강화형 글라스아이오노머의 색 안정성에 관한 연구)

  • Koo, Dae-Hoi;Lee, Yong-Keun;Son, Ho-Hyun;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.358-373
    • /
    • 1997
  • Resin modified glass ionomers were introduced in 1988 to overcome the problems of moisture sensitivity and low early mechanical strength of conventional glass ionomers and to maintain their clinical advantages. The purpose of this study was to evaluate the color stability of four resin modified glass ionomers(Fuji II LC, Vitremer, Dyract and VariGlass), one resin composite material(Z-100), and one conventional glass ionomer(GC Fuji II) under several conditions. These conditions were as follows: 1) before curing, 2) after curing, 3) after polishing, 4) after 500 thermocycling, 5) after 1,000 thermocycling, 6) after 1,500 thermocycling and 7) after 2,000 thermocycling. Three specimens of each material/shade combination were made. Materials were condensed into metal mold with a diameter of 10 mm and a thickness of 2.0 mm, and were pressed between glass plates. The material was polymerized using a light polymerizing unit(Visilux II, 3M, USA). After removal of excess, the surface was polished sequentially on wet sandpapers. A reflection spectrophotometer(Model TC-6FX, Tokyo Denshoku Co., Japan) was used to determine CIELAB coordinates($L^*,a^*$ and $b^*$) of each specimen. CIE standard illumination C was used as the light source. The results were as follows : 1. In comparing different shades of same material, CIELAB color difference(${\Delta}E^*$) value was not significantly different from each other(p>0.05). 2. CIELAB color difference(${\Delta}E^*$) values between after-curing and after-polishing were ranged from 5.53 to 27.08. These values were higher than those of other condition combinations. 3. CIELAB color difference(${\Delta}E^*$) values between before-thermocycling and after-thermocycling were ranged from 1.40 to 7.81. Despite the number of thermocycling increased, CIELAB color difference(${\Delta}E^*$) value was low. 4. The color stability of resin modified glass ionomers was more stable than that of conventional glass ionomers but less stable than that of Z100.

  • PDF

BI-AXIAL FRACTURE STRENGTH OF RESIN MODIFIED GLASS IONOMERS (레진강화형 글라스아이오노머의 2 축 굽힘강도)

  • Lee, Yong-Keun;Im, Mi-Kyung;Koo, Dae-Hoi;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.751-760
    • /
    • 1997
  • Resin-modified glass ionomers were introduced in 1988 to overcome the problems of moisture sensitivity and low early mechanical strengths of the conventional glass ionomers, and to maintain their dinical advantages. The purpose of this study was to evaluate the bi-axial fracture strength of four resinmodified glass-ionomers(Fuji II LC, Vitremer, Dyract, VariGlass), one resin composite material(Z-100), and one conventional glass-ionomer(Fuji II). Three specimens of each material and shade combination were made according to the manufacturers' instructions. Materials were condensed into metal mold with a diameter of 10mm and a thickness of 2.0mm and pressed between two glass plates. Resin-modified glass ionomers were polymerized using a Visilux II light curing unit by irradiating for 60 seconds from both sides, and conventional glass ionomer was cured chemically. After specimens were removed from the molds, surfaces were polished sequentially on wet sandpapers up to No. 600 silicone carbide paper. The specimens were thermocycled for 2,000 cycles between $5^{\circ}C$ and $55^{\circ}C$ distilled water. After thermocycling, bi-axial fracture strengths were measured using a compressive-tensile tester(Zwick 1456 Z020, Germany) with the cross head speed of 0.5mm/minute. The results were as follows: 1. Two factors of the kind and color of materials had a main effect on bi-axial fracture strength (p<0.01), and bi-axial fracture strength was influenced significantly by the kinds of materials (p<0.01). But there was no significant interaction between two variables of the kind and color of materials (p>0.05). 2. Comparing the mechanical properties of the materials, the elastic modulus of Z100 was higher than any other material, and there was no difference in the displacement at fracture among materials. The bi-axial fracture strength of Z100 was significantly higher than any other material, and that of resin-modified glass ionomers was significantly higher than that of conventional glass ionomer (p<0.05). 3. In the same material group, the color of material had little influence on the mechanical properties.

  • PDF