• 제목/요약/키워드: sand aggregate ratio

검색결과 204건 처리시간 0.019초

산업부산물인 가네트 미분말을 이용한 콘크리트의 역학적 성상에 관한 연구 (A Study on the Mechanical Properties of Concrete using Garnet Powder with Industrial By-Products)

  • 임병호;김태곤;박정민;김화중
    • 콘크리트학회논문집
    • /
    • 제11권3호
    • /
    • pp.123-130
    • /
    • 1999
  • In a preceding study(1), the using method of garnet powder has been studies through the various investigation of basic material properties on garnet powder, industrial by-products generated in Yungju, Kyungpook. In this study, the various properties of concrete mixed with garnet powder are examined as following condition : Unit weight of water (170kg/㎥), water-binder ratio W/B (53, 55 and 58%), sand-aggregate ratio (S/A) (43, 45 and 48%), substitutional ratio of garnet powder of 0, 5, 10, 15 and 20%. Slump increased a little as the substitutional ratio of garnet increased. Air content decreased a little at the substitutional ratio of 10%. or more. Though there is a little difference in compressive strength according to the W/B and the substitutional ratio, compressive strength of concrete using garnet exceeded that of plain concrete a little in the range of the substitutional ration of 5 to 15%. Also, There is a similar tendency in the tensile and flexural strength. Therefore, the use of garnet powder with industrial by-products is expected to improve the workability and the strength of concrete.

바닥용 모르타르의 균열방지를 위한 실험적 연구 (An Experimental Study for Crack Prevention of Floor Mortar)

  • 정재동;최응규;김진근;이칠성;이상순
    • 콘크리트학회지
    • /
    • 제8권3호
    • /
    • pp.167-175
    • /
    • 1996
  • 최근 건설 현장에서 소성수축과 건조수축으로 인한 바닥용 모르타르의 균열은 매우 심가하다. 이러한 바닥용 모르타르의 균열을 방지하기 위하여 필요한 작업성을 유지하면서 단위수량을 최소화하는 최적배합의 선정과 팽창제를 사용하여 수축을 보상하는 방법에 대하여 연구하였다. 현장조사에 의하면 현장에서 사용중인 바닥용 모르타르의 물 시멘트는 약 64%인 것으로 나타났다.그리고 바닥용 모르타르의 물 시멘트를 줄이더라도 조립율이 큰 잔골재를 사용하고 고성능감수제를 적정량만큼 첨가하면 필요한 작업성을 유지할 수 있는 것으로 나타났다. 또한 이 연구에서는 모르타르의 플로우와 물 시멘트비, 잔골재시멘트비, 잔골재의 조립율과의 관계식을 제안하였으며, 제시된 식은 바닥용 모르타르의 배합설계에 유용하게 활용될 것으로 판단된다.

재령에 따른 포장용 콘크리트의 강도특성 예측식 개발 (Development of Model Equations for Strength Properties with Age in Concrete Pavement)

  • 양성철;권수안;임유진
    • 한국방재학회 논문집
    • /
    • 제10권6호
    • /
    • pp.35-43
    • /
    • 2010
  • 본 연구는 콘크리트 포장설계법에 사용되는 재료입력변수의 DB화를 염두에 두고 신뢰성 있는 콘크리트 물성 정량화 수립을 목적으로 수행되었다. 실험에 사용된 포장용 콘크리트는 화강암, 석회암, 사암의 조골재를 사용하였으며 화강암 배합의 경우 세 골재로서 자연사, 세척사, 부순모래 배합을 포함하였다. 먼저 콘크리트 강도시험을 통해 얻은 데이터를 이용하여 강도간의 상관관계 모델식을 정리하였다. 그리고 각 조골재별로 재령에 따른 압축강도, 휨강도, 쪼갬인장강도 및 탄성계수의 모델식을 제시하였다. 화강암 배합의 경우 세골재로서 사용된 자연사, 세척사, 부순모래 배합을 모두 포함한 산술평균을 적용하여 모델식을 제시하였다. 한편 쪼갬인장강도와 탄성계수는 실험방법 및 계측상 결과가 분산되는 경향이 있어서 상관관계식에서 예측된 값과 직접 구한 실험결과에 대해 산술평균을 적용후 보정하여 각 조골재별로 재령에 따른 탄성계수 및 쪼갬인장강도의 예측식을 제시하였다. 마지막으로 각 조골재 배합별 콘크리트의 포와송비 및 건조수축에 대한 기준 값을 제시하였다.

경량콘크리트 연속보의 전단내력에 대한 골재크기의 영향 (Effect of Aggregate Size on the Shear Capacity of Lightweight Concrete Continuous Beams)

  • 양근혁;문주현
    • 콘크리트학회논문집
    • /
    • 제21권5호
    • /
    • pp.669-677
    • /
    • 2009
  • 철근콘크리트 연속 보의 전단거동에 대한 골재 최대직경의 영향을 평가하기 위하여 24개의 실험체가 실험되었다. 전경량, 모래경량 및 보통중량콘크리트 보에서 최대 골재직경은 4 mm에서 19 mm로 변하였으며, 전단경간비는 2.5와 0.6으로 있었다. 보통중량콘크리트 보의 무차원 최대전단내력에 대한 동일조건의 경량콘크리트 보의 무차원 최대 전단내력의 비가 ACI 318-05에서 제시하는 수정계수와 비교되었다. 파괴면에 대한 현미경 사진으로부터 경량콘크리트보의 파괴면은 주로 골재를 관통하지만 파괴되지 않은 경량골재들도 다수 발견되었는데, 이는 경량콘크리트 보의 전단거동 향상에 기여하였다. 이로 인해 경량콘크리트 연속 보의 최대전단내력은 골재 최대직경의 증가와 함께 증가하였는데, 그 증가기울기는 보통중량콘크리트 연속보에 비해 낮았다. ACI 318-05에서 제시하는 수정계수는 경량콘크리트 연속 보에서는 다소 불안전측에 있었는데, 그 불안전측은 최대 골재직경의 증가와 함께 증가하였다. 또한 ACI 318-05의 전단규정에 대한 안전성은 보통중량콘크리트 보에 비해 경량콘크리트 보에서 낮았다.

폐내화물 및 탈황석고의 치환율 변화에 따른 3종 고로슬래그 시멘트와 순환잔골재를 사용하는 모르타르의 품질향상 (Enhancement in the quality of mortar which uses uses 3-type blast-furnace slag cement and circulated fine aggregate, according to replacement ratio changes of waste refractories and desulfurized plaster)

  • 이재진;이제현;백철;김민상;윤원근;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 추계 학술논문 발표대회
    • /
    • pp.56-57
    • /
    • 2016
  • Recently amongst Korea's construction companies there has been heightened interest in environment load reduction and resource recycling. As a result, the construction industry is examining recycled materials alternative to cement and blast-furnace slag (BS henceforth) cement, such as waste refractories and desulfurized plaster. This study analyzes the liquidity and intensity characteristics of mortar according to changes in replacement ratios of waste refractories and desulfurized plaster, used as industry by-products in mortar environments that use BS 3-type cements and circulated fine aggregate. As a result, the greater the increase in replacement ratios of desulfurized plaster, the greater the increase in liquidity and air quantity, as well as compression strength.

  • PDF

Potential use of mine tailings and fly ash in concrete

  • Sunil, B.M.;Manjunatha, L.S.;Ravi, Lolitha;Yaragal, Subhash C.
    • Advances in concrete construction
    • /
    • 제3권1호
    • /
    • pp.55-69
    • /
    • 2015
  • Tailing Material (TM) and Fly Ash (FA) are obtained as waste products from the mining and thermal industries. Studies were carried out to explore the possibility of utilizing TM as a part replacement to fine aggregate and FA as a part replacement to cement, in concrete mixes. The effect of replacing fine aggregate by TM and cement by FA on the standard sized specimen for compressive strength, split tensile strength, and flexural strengths are evaluated in this study. The concrete mix of M40 grade was adopted with water cement ratio equal to 0.40. Concrete mix with 35% TM and 65% natural sand (TM35/S65) has shown superior performance in strength as against (TM0/S100, TM30/S70, TM40/S60, TM50/S50, and TM60/S40). For this composition, studies were performed to propose the optimal replacement of Ordinary Portland Cement (OPC) by FA (Replacement levels studied were 20%, 30%, 40% and 50%). Replacement level of 20% OPC by FA, has shown about 0-5% more compressive strength as against the control mix, for both 28 day and 56 days of water curing. Interestingly results of split tensile and flexural strengths for 20% OPC replaced by FA, have shown strengths equal to that of no replacement (control mix).

SCP 모듈 충전용 고유동 콘크리트의 최적배합 도출 및 채움성능 평가 (Evaluation of Optimum Mix Proportion and Filling Performance of High-fluidity Concrete for SCP Module charging)

  • 박기준;김성욱;박정준;이동규
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.452-459
    • /
    • 2017
  • 최근 특수 구조물의 경량화를 위해 프리스트레스트 콘크리트 대신 SCP(Steel Concrete Plate)와 같은 합성형 강판 콘크리트 구조모듈의 사용이 증가하고 있다. 다량의 스터드가 결합된 SCP 모듈의 경우 복잡한 단면과 내부구조로 인하여 유동성과 충전성이 우수한 고유동 콘크리트의 사용이 요구된다. 따라서 본 연구에서는 팽창재 및 수축저감제 사용에 따른 영향을 검토하여 스터드에 의한 수축거동을 방지하고, 잔골재율 및 잔골재 종류별 혼입비율을 검토하여 재료의 사용성 및 충전성을 극대화 시킬 수 있는 최적 배합을 도출하고자 하였다. 그 결과 팽창재 또는 수축저감제의 단독사용보다 병행하여 사용할 경우 가장 적은 수축거동을 나타내어 SCP 모듈 충전용 고유동 콘크리트의 제조에 가장 적합한 것으로 판단된다. 잔골재율이 너무 높은 경우 강도 저하 및 수축량 증가의 우려가 있어 최종배합으로 부순모래와 세척사의 비율을 5:5로 선정하였으며, 잔골재율은 55.6%가 적합한 것으로 판단된다. 대형 SCP 모듈 내 고유동 콘크리트 채움성능 평가를 위해 타설을 진행한 결과 SCP 모듈내 고유동 콘크리트 채움성은 양호한 결과를 나타냈다.

고유동 충전재의 개발과 노후 터널의 배면공동 뒤채움에 관한 연구 (A Study on Development of the Controlled Low-Strength and High-Flowable Filling Material and Application of the Backfilling in Cavities behind the Old Tunnel Lining)

  • 마상준;서경원;배규진;안상철;임경하
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권3호
    • /
    • pp.177-184
    • /
    • 2002
  • The most tunnel damage such as cracks or leakage which exist in tunnel lining commonly, is caused by the cavities where exist behind the tunnel lining, through the tunnel safety inspections. These cavities were analysed to affect a stability of a running-tunnel seriously. This study is on the development of the controlled low-strength and flowable filling material which is able to apply to the cavity behind the tunnel lining. The major materials of backfilling developed are a crushed sand and a stone-dust which exists as a cake-state and is a by-product obtained in the producting process of aggregate. It is conformed with the design standard to the physical characteristics of backfilling. The backfilling material developed is designed to reduce the fair amount of cement. According to the designed compound ratio, it is carried out the laboratory tests such as a compressive strength and a chemical analyses and is applied to dilapidated old tunnel for an application assessment.

Effect of Iron Ore Tailings Replacing Porous Basalt on Properties of Cement Stabilized Macadam

  • Qifang Ren;Fan Bu;Qinglin Huang;Haijun Yin;Yuelei Zhu;Rui Ma;Yi Ding;Libing Zhang;Jingchun Li;Lin Ju;Yanyan Wang;Wei Xu;Haixia Ji;Won-Chun Oh
    • 한국재료학회지
    • /
    • 제34권6호
    • /
    • pp.291-302
    • /
    • 2024
  • In this paper, iron ore tailings (IOT) were separated from the tailings field and used to prepare cement stabilized macadam (CSM) with porous basalt aggregate. First, the basic properties of the raw materials were studied. Porous basalt was replaced by IOT at ratios of 0, 20 %, 40 %, 60 %, 80 %, and 100 % as fine aggregate to prepare CSM, and the effects of different cement dosage (4 %, 5 %, 6 %) on CSM performance were also investigated. CSM's durability and mechanical performance with ages of 7 d, 28 d, and 90 d were studied with the unconfined compression strength test, splitting tensile strength test, compressive modulus test and freeze-thaw test, respectively. The changes in Ca2+ content in CSM of different ages and different IOT ratios were analyzed by the ethylene diamine tetraacetic acid (EDTA) titration method, and the micro-morphology of CSM with different ages and different IOT replaced ratio were observed by scanning electron microscopy (SEM). It was found that with the same cement dosage, the strengths of the IOT-replaced CSM were weaker than that of the porous basalt aggregate at early stage, and the strength was highest at the replaced ratio of 60 %. With a cement dosage of 4 %, the unconfined compressive strength of CSM without IOT was increased by 6.78 % at ages from 28 d to 90 d, while the splitting tensile strength increased by 7.89 %. However, once the IOT replaced ratio reached 100 %, the values increased by about 76.24 % and 17.78 %, which was better than 0 % IOT. The CSM-IOT performed better than the porous basalt CSM at 90 d age. This means IOT can replace porous basalt fine aggregate as a pavement base.

고주파 유도로를 이용한 산업 폐기물의 용융처리 (Treatment of Industrial Wastes by Melting Using H.F. Induction Furnace)

  • 정진기;정헌생;이재천;윤인주;남기대
    • 자원리싸이클링
    • /
    • 제6권1호
    • /
    • pp.23-28
    • /
    • 1997
  • 고주파 유도로에서 철캔, 석회석 슬러지, 폐줌루사, 석탄회, 그리고 폐유리병을 용융하여 철과 슬랙을 얻고 그 특성을 연구하였다. 직교 배열표를 이용하여 각 폐기물의 장입비가 최종 용융물의 물성에 미치는 영향을 조사하였다. 염기도 1.2에서 $\beta$-C$_2$S상과 $C_2$AS상이 주요한 상인 용융물이 생성되었으며 두 상의 분율은 폐기물 원료의 배합비율에 따라 변하였다. 철의 회수율은 93-95% 정도였으며 슬랙은 용출 및 압축시험 결과 일반 골재로서의 사용 가능성이 확인되었다.

  • PDF