• Title/Summary/Keyword: sampler flow rate

Search Result 17, Processing Time 0.024 seconds

A Suggested Air Sampling Strategy for Bioaerosols in Daycare Center Settings (어린이활동공간에서의 바이오에어로졸 포집 전략)

  • Jo, JungHeum;Park, Jun-sik;Kim, Sung-Yeon;Kwon, Myung hee;Kim, Ki Youn;Choi, Jeong-Hak;Seo, SungChul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.324-333
    • /
    • 2016
  • Objectives: We aimed to compare the sampling performance of different flow-based impactor samplers for collecting fungal spores and bacteria and to explore the association of the level of bioaerosols with activity patterns of occupants in daycare center settings. Methods: For comparison of sampling performance, two different flow-based samplers (greater than 100 L/min or not) were selected; a low flow-based sampler (one-stage Andersen sampler) and two high flow-based samplers (DUO SAS SUPER 360 sampler, BUCK bio-culture sampler). We collected airborne mold and bacteria in 30 daycare centers with various levels of contaminated air. Three repeat samplings per each sampler were performed. Mold and bacteria were grown for 96 hours at $25{\pm}1^{\circ}C$ and 48 hours at $35{\pm}1^{\circ}C$, respectively. The Andersen and SAS samplers were used for investigating the association between the level of bioaerosols and the activity patterns of occupants in daycares. Particular matters 10($PM_{10}$), temperature, and relative humidity were monitored as well. Samplings were carried out with one-hour interval from 9 to 5 O'clock. For statistical comparisons, Kruskal-Wallis test, Wilcoxon's signed rank test, and multiple regression analysis were carried out. Results: The airborne level of molds by the low flow-based sampler were significantly higher than that of high flow-based samplers (indoor, P=0.037; outdoor, P=0.041). However, no statistical difference was observed in the airborne level of bacteria by each sampler. Also the level of bioaerosols varied by the time, particularly with different activity patterns in daycare centers. The higher level of mold and bacteria were observed in play time in indoor. Similarly, the concentrations of $PM_{10}$ were significantly associated with the level of bioaerosols (P<0.05). Conclusions: Our findings indicate that the flow rate of sampler, rather than total air volume, could be able to affect the results of sampling. Also, the level of airborne mold and bacteria vary behavior patterns of occupants in indoor of daycare settings. Therefore, different samplers with other flow rate may be selected for mold or bacteria sampling, and activity patterns should be considered for bioaerosol sampling as well.

Development of a Passive Sampler using 4-amino-3-hydrazino-5-mercapto-1, 2, 4-triazole for Measuring Indoor Formaldehyde (4-Amino-3-hydrazino-5-mercapto-1, 2, 4-triazole을 이용한 실내 포름알데히드 측정용 passive sampler 개발)

  • Kim Sun-Tae;Yim Bongbeen;Jeong Jaeho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.593-603
    • /
    • 2005
  • Passive sampler using 4-amino-3-hydrazino-5-mercapto-1, 2, 4-triazole (AHMT) was developed to determine formaldehyde in indoor environment. The chromatography paper cleaned by $3\%$ hydrogen peroxide solution was experimently determined as a optimum absorbtion filter for the collection of formaldehyde. The passive sampler with a broad cross-sectional area and a short diffusion length was quite good in sensitivity. The passive sampler and the active sampling method with an impinger were strongly correlated with a correlation coefficient of 0.9848. The limits of detection and quantification of the passive sampler for the measurement of formaldehyde in the indoor environment were 7.5 and 10.2 ppb, respectively. Temperature ($19\∼28^{circ}C$) and relative humidity ($30\∼90\%$) had slight influence on the sampling rate of the passive sampler. However, the increase of flow velocity on the surface of sampler resulted in the increase of sampling rate.

Minimum Detectable Radioactivity Concentration of Atmospheric Particulate Measurement System for Nuclear Test Monitoring (핵활동 감시를 위한 대기 입자 측정시스템의 최소검출 방사능 농도 결정)

  • Kim, Jong-Soo;Yoon, Suk-Chul;Shin, Jang-Soo;Kwack, Eun-Ho;Choi, Jong-Seo
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.111-117
    • /
    • 1997
  • Recently, the conclusion of Comprehensive Test Ban Treaty(CTBT) is globally constructing a network system for nuclear test monitoring. The radionuclide experts of the Conference on Disarmament recommended that the detection of nuclear debris in the atmosphere was an essential factor of nuclear test monitoring and proposed the technical requirements. Based on those requirements, atmospheric radionuclide monitoring system to detect nuclear debris generated from the nuclear explosion test was composed. The system is comprised of high volume air sampler(HVAS), filter paper presser and high purity germanium detector(HPGe). Minimum detectable concentrations(MDCs) of the key nuclides requiring in CTBT monitoring strategies are determined by considering of decay time, counting time and flow rate of the high volume air sampler for the rapid explosion and the optimum measurement condition. The results were selected $10{\pm}$2h, $20{\pm}$2h and $850{\pm}50m^3$/h as parameters, respectively. The relation between the natural air-borne radionuclide concentration of $^{212}Pb$ and MDC were calculated which gave effect in the Compton continuum baseline due to those nuclides in the gamma-ray spectroscopy. These results can be used as an actually tool in the CTBT monitoring strategies.

  • PDF

Characterization of PM10 and PM2.5 Mass Concentrations in Jinju (진주시 대기중 PM10 및 PM2.5의 질량농도 특성)

  • Park, Jeong-Ho;Park, Gee-Hyeong;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.1963-1970
    • /
    • 2014
  • Ambient particulate matters($PM_{10}$ and $PM_{2.5}$) were investigated at GNTECH university in Jinju city. Samples were collected using a dichotomous sampler(series 240, Andersen Corp.) and a TEOM(Tapered Element Oscillating Microbalance) monitor period from November 2012 to October 2013. For the dichotomous sampler measurements, daily 24-h integrated $PM_{2.5}$ and $PM_{10-2.5}$ ambient air samples were collected at a total flow rate of 16.7 L /min. For the TEOM monitor measurements, daily 1-h integrated $PM_{10}$ ambient air samples were collected at a flow rate of 16.7 L /min. The annual average concentrations of $PM_{10-2.5}$ and $PM_{2.5}$ by a dichotomous sampler were $10.0{\pm}6.1{\mu}g/m^3$ and $22.6{\pm}9.3{\mu}g/m^3$, respectively. And $PM_{10}$ concentration by dichotomous sampler were similar to TEOM monitor by $32.7{\pm}12.9{\mu}g/m^3$ and $31.7{\pm}11.3{\mu}g/m^3$, respectively. And good correlation ($R^2=0.964$) between the two methods was observed. The annual average of $PM_{2.5}/PM_{10}$ ratio was $0.70{\pm}0.12$.

The Nationwide NO$_2$Monitoring with Passive Sampler in Korea

  • Kim, Sun-Tae;Kim, Han-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E2
    • /
    • pp.69-77
    • /
    • 2002
  • The nationwide NO$_2$monitoring program has been carried out using the passive sampler in Korea since 1993. During the sixteenth periods of measurement, total 26,474 sites of data were collected through eight years. In this paper, the roadside NO$_2$concentration of six major cities were analyzed. As results, the most frequent NO$_2$concentration of Seoul, Incheon, and Daegu ranged from 40 to 60 ppb, and that of Pusan, Kwanju, and Daejeon was from 20 to 40 ppd. Despite that the automobile number of Incheon was less than that of Daegu and Pusan, the exceedence rate of Korean national ambient air quality standard and ninetieth percentile concentration of Incheon were almost the same level as Seoul. In addition, the mean and standard deviation of roadside NO$_2$concentration of Seoul and Incheon was also appeared to be higher than that of other cities. These results indicates that NO$_2$concentration on roadside was affected by the traffic volumes and the traffic flow conditions.

Hydrograph Separation using Geochemical tracers by Three-Component Mixing Model for the Coniferous Forested Catchment in Gwangneung Gyeonggido, Republic of Korea

  • Kim, Kyongha;Yoo, Jae-Yun
    • Journal of Korean Society of Forest Science
    • /
    • v.96 no.5
    • /
    • pp.561-566
    • /
    • 2007
  • This study was conducted to clarify runoff production processes in forested catchment through hydrograph separation using three-component mixing model based on the End Member Mixing Analysis (EMMA) model. The study area is located in the coniferous-forested experimental catchment, Gwangneung Gyeonggido near Seoul, Korea (N 37 45', E 127 09'). This catchment is covered by Pinus Korainensis and Abies holophylla planted at stocking rate of 3,000 trees $ha^{-1}$ in 1976. Thinning and pruning were carried out two times in the spring of 1996 and 2004 respectively. We monitored 8 successive events during the periods from June 15 to September 15, 2005. Throughfall, soil water and groundwater were sampled by the bulk sampler. Stream water was sampled every 2-hour through ISCO automatic sampler for 48 hours. The geochemical tracers were determined in the result of principal components analysis. The concentrations of $SO_4{^{2-}$ and $Na^+$ for stream water almost were distributed within the bivariate plot of the end members; throughfall, soil water and groundwater. Average contributions of throughfall, soil water and groundwater on producing stream flow for 8 events were 17%, 25% and 58% respectively. The amount of antecedent precipitation (AAP) plays an important role in determining which end members prevail during the event. It was found that ground water contributed more to produce storm runoff in the event of a small AAP compared with the event of a large AAP. On the other hand, rain water showed opposite tendency to ground water. Rain water in storm runoff may be produced by saturation overland flow occurring in the areas where soil moisture content is near saturation. AAP controls the producing mechanism for storm runoff whether surface or subsurface flow prevails.

Comparison of PM2.5 Concentrations by Measurement Method (측정 방법에 따른 PM2.5 농도 비교)

  • Ghim, Young Sung;Choi, Yongjoo;Park, Jisoo;Kim, Pilho;Han, Yu Kyung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.5
    • /
    • pp.515-520
    • /
    • 2017
  • $PM_{2.5}$ concentrations were measured using a cyclone, impactor (the U.S. Environmental Protection Agency well impactor ninety-six, WINS) and optical particle counter (OPC) at a campus site located in Yongin for the period August 2014 through March 2017. The concentrations from cyclone (Y) were generally higher than those from impactor(X); the best-fit line was Y=1.22X+5.64. The ratios of $PM_{2.5}/PM_{10}$ ranged from 0.61 to 0.66 when $PM_{2.5}$ concentrations from cyclones in selected studies were converted into those from impactors using a regression equation in this study. The slope of the best-fit line between OPC and impactor was close to 1 at 0.95, while that between OPC and cyclone was 0.72. After sampling, the flow rate in the low-volume air sampler with cyclone decreased by 3% on average, which did not have a significant effect on measured concentrations.

Characteristics of Inorganic Components in Fine Particles Collected at Chunchon during the Springtime Yellow Sand Occurrence Period in 2002 (춘천에서 2002년 봄철 황사 발생기간 동안에 채취된 미세분진 중 무기성분의 특성)

  • 김희갑;정경미;김동진;이종태
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.4
    • /
    • pp.333-339
    • /
    • 2002
  • Yellow sand (YS) storms were observed about ten times in the Korean peninsula during March and April in 2002. Twenty four hour fine particle (PM$\_$2.5/) samples were collected onto the 47 mm Teflon - coated quartz filters over 9 days during and after the events using the MiniVol Portable Air Sampler at a flow rate of 5 liters per minute. The highest PM$\_$2.5/ concentration measured during the YS period was 289 $\mu\textrm{g}$/㎥, which is 13 times higher than the lowest of the values for the samples collected during the non-yellow sand period. The filter samples were analyzed for inorganic ions using the IC, AAS and Autoanalyzer, and for metals using the ICP-MS. The results showed that the concentrations of some inorganic ions (e.g., Ca$\^$2+/ and SO$_4$$\^$2-/) and metals (e.g., Fe, Mn) of soil origin were elevated during the yellow sand events.

Analyses of Shear Stress and Erosion Characteristic in a Vegetated Levee Revetment with Root Fiber Quantity (근모량에 따른 식생호안의 전단강도와 침식특성 분석)

  • Choi, Heung Sik;Lee, Woong Hee
    • Ecology and Resilient Infrastructure
    • /
    • v.1 no.1
    • /
    • pp.29-38
    • /
    • 2014
  • This study analyzed shear stress and erosion characteristic of a vegetated levee embankment with root fiber quantity, which is an important factor for evaluating the stability of it. The averaged root fiber quantity in a vegetated levee revetment was measured by the sampler manufactured by this research. The Phragmites Japonica Steud which is somewhat dominant species in a vegetated levee embankment was selected as an experimental vegetation. As a result of experiment of each flow regime, the shear stress was increased while root fiber quantity was increased and the erosion rate was exponentially decreased as the root fiber quantity was increased. The erosion rate was exponentially decreased as the shear stress was increased which is shown that the increase of shear stress by root fiber quantity results in the increase of erosion resistance in a vegetated soil. The relationship between shear stress and erosion rate with root fiber quantity were analyzed and their regression equations were suggested with high determination coefficients. The hydraulic stability is governed by the increase of shear stress by root fiber quantity and the Froude number of flow characteristic in a vegetated levee revetment.

Application of Semi-continuous Ambient Aerosol Collection System for Elemental Analysis (대기입자의 원소성분 배출특성연구를 위한 반-연속식 입자채취시스템 적용)

  • Park, Seung-Shik;Ko, Jae-Min;Lee, Dong-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.1
    • /
    • pp.39-51
    • /
    • 2012
  • Aerosol slurry samples were collected in 60-min interval using Korean Semi-continuous Elements in Aerosol Sampler (KSEAS) between May 19 and June 6, 2010 at an urban site of Gwangju. The $PM_{2.5}$ samples were collected with a flow rate of 16.7 L/min and particles are grown by condensation of water vapor in a condenser maintained at ${\sim}5^{\circ}C$ after saturation by direct injection of steam. The resulting droplets are collected in a liquid slurry with a airdroplet separator. Concentrations of 16 elements (Al, Fe, Mn, Ca, K, Cu, Zn, Pb, Cd, Cr, Ti, V, Ni, Co, As, Se) in the collected slurry samples were determined off-line by ICP-MS. KSEAS sample analysis encompassed the sampling periods for which 24-hr average elemental species concentrations were calculated for comparison with those derived from 24-hr integrated filter samples. Relationship between elemental species measured by two methods indicated high correlation coefficients (r), mostly greater than r of 0.80. However, we note that concentrations of Al, K, Ca, Mn, and Fe, which are often associated with crustal elemental particles, in the KSEAS samples, were substantially lower (1.4~11 times) than those found in the typical filter-based samples. This discrepancy is probably due to difficulties in transferring insoluble dust particles to the collection vials in the KSEAS. Temporal profiles of elemental concentrations indicate that some transient events in their concentrations are observed over the sampling periods. For the elemental species studied, atmospheric concentrations during the transient events increased by factors of 4 in Mn~80 in Zn, compared to their background levels. Principle component analyses were applied to the hourly KSEAS data sets to identify sources affecting the concentrations of the metal constituents observed. In this study, we conclude that hourly measurements for particle-bound elemental constituents were extremely useful for revealing the short-term variability in their concentrations and developing insights into their sources.