• Title/Summary/Keyword: sample injection method

Search Result 168, Processing Time 0.022 seconds

A STUDY ON THE PHYSICAL PROPERTIES AND VOLUMETRIC STABILITY OF SR-IVOCAP RESIN SYSTEM (SR-Ivocap resin system의 물리적 특성과 체적 안정성에 관한 연구)

  • Eun, Sung-Sik;Kweon, Hyeog-Sin;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.453-467
    • /
    • 1998
  • This study helps to clarify conflicting reports by comparing the physical properties and accuracy of complete denture processed by the pack and press technique, continuous- pressure injection technique(SR-Ivocap system) and Mark press technique. The 6 different specimens have been evaluated using the SEM, Impact test, DSC (Differential Scanning Calorimetry) and DMTA (Dynamic Mechanical Thermal Analysis). Each sample was made of SR-Ivocap resin and QC-20 resin by different processing methods. The results were as follows ; 1. As the result of the observation on the fracture surface of resin by use of SEM, sample SR-Ivocap resin cured by continuous pressure injection method showed the most homogeneous structure. This is why molecules in SR-Ivocap resin have no orientation. 2. As the result of the Impact test in order to measure the deformity, fracture energy and impact resistance of resin, the samples with QC-20 acrylic resin and SR-Ivocap resin cured by continuous pressure injection method were exellent. 3. In consequence of measuring ${\alpha}$-glass transition temperature by use of DSC on the basis of temperature change, the glass transition temperatures of sample QC-20 resin cured by pack and press method and sample SR-Ivocap resin cured by continuous pressure injection method were very similar. Thus volumetric stability could not be evaluated only by glass transition temperature. 4. In comparing volumetric stability data by DMTA, the glass transition temperature(Tg) showed $137.88^{\circ}C$ at sample QC-20 resin cured by pack and press method and $139.78^{\circ}C$ at sample SR-Ivocap resin cured by continuous pressure injection method. Therefore sample SR-Ivocap resin cured by continuous pressure injection method seems to be superior to sample QC-20 resin cured by pack and press method in the dimensional stability at high temperature. 5. In comparing storage modulus data by DMTA, the storage modulus of sample SR-Ivocap resin cured by continuous pressure injection method was higher than that of sample QC-20 resin cured by pack and press method. So. sample SR-Ivocap resin cured by continuous pressure injection method seems to be superior to sample QC-20 resin cured by pack and press method in impact strength.

  • PDF

Seismic wave monitoring of $CO_2$ migration in water-saturated porous sandstone

  • Xue Ziqiu;Ohsumi Takashi
    • Geophysics and Geophysical Exploration
    • /
    • v.7 no.1
    • /
    • pp.25-32
    • /
    • 2004
  • We have carried out laboratory measurements of P-wave velocity and deformation strain during $CO_2$ injection into a porous sandstone sample, in dry and water-saturated conditions. The rock sample was cylindrical, with the axis normal to the bedding plane, and fluid injection was performed from one end. Using a piezoelectric transducer array system, we mapped fluid movement during injection of distilled water into dry sandstone, and of gaseous, liquid, and supercritical $CO_2$ into a water-saturated sample. The velocity changes caused by water injection ranged from $5.61\;to\;7.52\%$. The velocity changes caused by $CO_2$ injection are typically about $-6\%$, and about $-10\%$ for injection of supercritical $CO_2$, Such changes in velocity show that the seismic method may be useful in mapping $CO_2$ movement in the subsurface. Strain normal to the bedding plane was greater than strain parallel to the bedding plane during $CO_2$ injection; injection of supercritical $CO_2$ showed a particularly strong effect. Strain changes suggest the possibility of monitoring rock mass deformation by using borehole tiltmeters at geological sequestration sites. We also found differences associated with $CO_2$ phases in velocity and strain changes during injection.

Analysis of Perchlorate in Water Using Ion Chromatograph with Preconcentration (이온크로마토그래프를 이용한 수중의 퍼클로레이트 농축 및 분석)

  • Kim, Hak-Chul
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.4 s.62
    • /
    • pp.29-38
    • /
    • 2006
  • This study included the development of analytical method for determining perchlorate in water sample. The analytical condition was referred in EPA 314.0 method which use ion chromatography and the concentrator column was replaced by the guard column. Concentrating 10mL raw or treated water sample on to AGl6 guard column made it possible to get the LOD(Limit of Detection) of $0.73\;{\mu}g/L$. The total run time was 11 minutes and during run time next sample could be concentrated on AGl6 guard column. Compared to the Concentration method which needed manual operation, the Direct Injection method could screen the many water samples. The LOD of the Direct Injection method was higher and the sensitivity was lower than that of the Concentration method. The RSDs(Relative Standard Deviations) were lower than 2.5 % for peak height and 0.7 % for retention time in pre-concentration methods. This method Showed good reproducibility and reliability and it was thought the deviations of recovery value could be reduced by considering column capacity and making water sample homogeneous. Matrix Elimination could be done using the pre-concentration method if perchlorate were in complex matrix of sample.

Effects of Aconiti Tuber on the Change of Interleukin-6 and $TNF-{\alpha}$ Level induced by LPS I.C.V. Injection in Mice (부자(附子)가 Lipopolysaccharide의 뇌실 주입으로 유발된 생쥐의 혈중 IL-6와 $TNF-{\alpha}$ 변화에 미치는 영향)

  • Koh Dong-Kyun;Yun Jeong-Moon;Lee Tae-Hee
    • Herbal Formula Science
    • /
    • v.12 no.1
    • /
    • pp.195-208
    • /
    • 2004
  • Objective: This study was conducted to investigate the effects of Aconiti Tuber on the plasma IL-6 and $TNF-{\alpha}$ level in mice stimulated by intracerebroventricular(I.C.V.) Injection of Lipopolysaccharide(LPS). Method: 6 mice were assigned to each of the normal group, the control group, and the experimental group. In the normal group only saline was administered intragastrically, and in the control group LPS was injected intracerebro-ventricularly 1 hr after intragastric administration of saline. In the experimental groups (Aconiti Tuber 0.5g/kg, Aconiti Tuber 1.0g/kg, Aconiti Tuber 3.0g/kg) each sample was administered intragastrically to mice 1 hr prior to the stimulation by LPS I.C.V. Injection. To measure the plasma IL-6 and $TNF-{\alpha}$ level of mice, their blood samples were collected from retro-orbital plexus, immediately centrifuged at $4^{\circ}C$, and plasma was removed and stored frozen at $-83^{\circ}C$ for later determination of plasma IL-6 and $TNF-{\alpha}$. Result : 1. LPS I.C.V. Injection increased plasma IL-6 level significantly in a dose-dependent manner compared with normal group(P<0.01). The plasma IL-6 concentration reached a significant maximal level about 1 hr after LPS I.C.V. Injection(P<0.001). LPS I.C.V. Injection increased plasma $TNF-{\alpha}$ level significantly in a dose-dependent manner(P<0.05). The plasma $TNF-{\alpha}$ concentration reached a significant maximal level about 1 hr after LPS I.C.V. Injection(P<0.001). 2. Sample A group to which Aconiti Tuber(0.5g/kg) was administered intragastrically 1 hr prior to the stimulation by LPS I.C.V. Injection showed insignificant lower plasma IL-6 level in 1 hr than control group(P<0.0635), and sample B group (Aconiti Tuber 1.0g/kg) showed significant lower plasma IL-6 level in 1 hr than control group(P〈0.05), and sample C group (Aconiti Tuber 3.0g/kg) showed significant lower IL-6 plasma level in 1 hr than control group(P<0.01). 3. sample A group to which Aconiti Tuber(0.5g/kg) was administered intragastrically 1 hr prior to the stimulation by LPS I.C.V. Injection showed insignificant lower plasma $TNF-{\alpha}$ level in 1 hr than control group(P>0.05), and Both sample B(1.0g/kg) and sample C(3.0g/kg) groups showed significant lower $TNF-{\alpha}$ plasma level in 1 hr than control group(P<0.01). These data revealed that Aconiti Tuber might have the anti inflammatory effect by reducing the plasma IL-6 and $TNF-{\alpha}$ level in a dose dependent manner in mice LPS I.C.V. Injection.

  • PDF

The Study on Analysis Method and Performance Evaluation of Portable GC/MS (휴대용 GC/MS 성능검사 및 분석방법 연구)

  • Park, Yuonshin;Noh, Hyeran;Yang, Heeseon;Seok, Gwanseol
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.249-258
    • /
    • 2013
  • Recieved Mar. 06, 2013 Revised Mar. 29, 2013 Accepted Sep. 11, 2013In this study, we evaluated the method performance and the optimum sample injection method of the portable GC/MS(HAPSITE) which were designed to operate on scene of chemical accidents. Chemicals used for performance test were vinyl chloride(VC), methyl chloride(MC), benzene(Bz), toluene(Tol). CRM(Certified Reference Material) Manufactured by KRISS(Korea Research Institute of Standards and Science) was used as the standard gas. The results showed that 1) Among three sample injection methods(Cylinder, Silico canister, and Bag), bag was identified as the most appropriate sample injection method. Bag material and capacity did not significantly affect the results. The most ideal reproducibility occurred at the 2-minute point of the purge time in the loop and tenax methods. 2) Performance evaluation of HAPSITE was conducted. Evaluation items were reproducibility, linearity, method detection limit, etc. Tenax concentration method was appropriate for larger molecules and Carbopack concentration method was suitable for smaller molecules.

The Selection of Sample Injection Modes and Its Effect on the Calibration Bias in S Gas Detection by Gas Chromatography (GC의 주입방식 차에 따른 고농도 악취황 성분의 검량오차 연구 : 주입부피의 고정방식 대비 주입농도의 고정방식 간 비교연구)

  • Kim Ki-Hyun;Choi YJ
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.269-274
    • /
    • 2005
  • In this work, analytical bias arising from the gas chromatographic determination of sulfur compounds was evaluated by the application of direct loop injection method to the GC/PFPD detection of four sulfur compounds including H$_{2}$S, CH$_{3}$SH, DMS, and DMDS. For the proper evaluation of analytical uncertainties involved in GC calibration, we employed two comparative techniques of calibration at fxed concentration injection (CFCI) vs calibration at fixed volume injection (CFVI) method. The results of our study indicate that CFCI method exhibits very poor sensitivity due to the matrix effect with varying injection volumes. On the other hand, as CFVI method overcomes such limitation, it can be used to obtain very accurate quantification of S compounds at their high concentration levels above a few to a few tens ppb.

Transmission Electron Microscopy Sample Preparation of Ge2Sb2Te5 Nanowire Using Electron Beam

  • Lee, Hee-Sun;Lee, Jun-Young;Yeo, Jong-Souk
    • Applied Microscopy
    • /
    • v.45 no.4
    • /
    • pp.199-202
    • /
    • 2015
  • A simple and novel transmission electron microscopy (TEM) sample preparation method for phase change nanowire is investigated. A $Ge_2Sb_2Te_5$ (GST) nanowire TEM sample was meticulously prepared using nanomanipulator and gas injection system in a field emission scanning electron microscopy for efficient and accurate TEM analysis. The process can minimize the damage during the TEM sample preparation of the nanowires, thus enabling the crystallographic analysis of as-grown GST nanowires without unexpected phase transition caused by e-beam heating.

An experimental study on the biological safety and compatability of P.V.C. made in Korea (한국산 P.V.C.의 생물학적 안정도 및 적합성에 대한 실험적 고찰)

  • Sun, Kyung
    • Journal of Chest Surgery
    • /
    • v.17 no.1
    • /
    • pp.157-166
    • /
    • 1984
  • These biologic test procedures are designed to test the suitability of P.V.C. made in Korea intended for parenteral preparation, which were based on the U.S. Pharmacopeia XIX "Biologic Test-Plastic Container", Official from July 1, 1975. Healthy adult human blood and rabbits weighing 2\ulcorner.2Kg were used for test materials. Sample P.V.C. were sampled from the medical equipments made in Korea randomly and Control P.V.C. were sampled from the standardized Cobe and Polystan P.V.C. tubes. P.V.C. extract was prepared from a homogeneous P.V.C. samples by incubating 60 square centimeters of the sample per 20 millimeters of sterile pyrogen-free saline at 70\ulcorner for 72 hours or autoclaving at 120\ulcorner for 1 hour. The Implantation Test was designed to evaluate the reaction of living tissue to the plastic by the method of the implantation of the Sample itself into animal tissue. The Systemic Injection Test, the Intracutaneous Test, and the remainders were designed to determine the biological response of animals to plastics by the single-dose injection of specific extracts prepared from a Sample. The results are as follows; 1.Implantation Test - No significant difference for reactions was noted between the Sample treated animal and the Control after 72 hours of implantation. 2.Systemic Toxicity Injection Test - No sign of toxicity and/or death immediately after injection and at 4, 24, 48 hours respectfully after injection. 3.Intracutaneous Test - None of the animals treated with the Sample showed a significantly greater reaction than the observed in the animals treated with Blank. 4.Pyrogen Assay-Only one animal treated with the Sample showed the maximal rise of rectal temperature about 0.2\ulcorner after 3 hours of injection, but remainders showed no change. 5.Hemolytic Index - The positive Control tube of distilled water exhibited complete hemolysis while the negative Control tube and P.V.C. extract were negative demonstrating no hemolysis. 6.Cell Morphology of Erythrocytes and Leukocytes on Stored, Heparinized Human Blood -- There was no significant difference in the morphology of either the Control or Sample extract. 7.Clotting Mechanism of Human Blood in vitro - After allowing to the P.V.C. extract at room temperature for 5 Hours and at 10\ulcorner for 24 hours, there was no appreciable difference in Prothrombin Time under these conditions. 8.Clotting Mechanism of Rabbit in vivo - At the termination of 5 days after intraperitoneal injection of the P.V.C. extract, no significant changes in Clotting Time were observed. According to the above results, it could be concluded that the P.V.C. made in Korea was acceptable for parenteral preparation, especially treated with physiologic saline and/or human blood.man blood.

  • PDF

Experimental Study on Injection Rate Effects during Gas Hydrate Production using Flue Gas Swapping Method (가스하이드레이트 배가스 치환 시 주입유속의 영향에 관한 실험적 연구)

  • Lee, Dong-Gun;Lee, Joo-Yong;Lee, Min-Hui;Lee, Jae-Hyung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.196-199
    • /
    • 2008
  • In this study, gas hydrate production has been followed using swapping method to investigate the effect of injection rate of flue gas and soaking period in unconsolidated artificial sand sample. The results shows that recovery factor of methane gas decreases with increasing the injection rate of flue gas. This indicates that the velocity of flue gas in porous media may act as kinds of inhibitor for production of hydrate. Also recovery factor increases with increasing the soaking time.

  • PDF

The Transient Phenomena of Fuel Injection Nozzle for Electronic Control SI Engines (SI 機關용 電子制御 燃料噴射노즐의 過渡的 現象)

  • 김신구;김덕줄;이충원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.2
    • /
    • pp.308-318
    • /
    • 1988
  • The liquid disintegration and characteristics of atomization through the swirl nozzle is affected by injection pressure and injection time when the liquid is injected intermittently. These transient phenomena are investigated by electronic controlled-fuel injection nozzle. The effect of injection conditions on disintegration of liquid injected through nozzle is observed photographically by using delay circuit. Droplet size of the element of the sample is measured by the liquid immersion sampling technique. SMD of droplets is varied with time and is decreased as the injection pressure increases. As the injection pressure increases, the maximum diameter of droplet and diameter of droplet which has the maximum droplet number decrease. Spray angle is not affected on injection pressure and change of spray angle with time is associated with needle movement.