• 제목/요약/키워드: sample and holder

검색결과 80건 처리시간 0.029초

비정질 칼코게나이드 박막에 Surface Relief 격자 형성 (The recording of surface relief grating on the chalcogenide thin film)

  • 박종화;장선주;박정일;여철호;이영종;정홍배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.299-302
    • /
    • 2000
  • In this study, we have made the large holographic surface relief gratings on amorphous chalcogenide $As_{40}$$Ge_{10}$$Se_{15}$$S_{35}$ films by two beam interference using a He-Ne laser(632.8nm) light. The film thickness was about 0.6$\mu\textrm{m}$, we could magnify beam size by using beam expander. We made use $90^{\circ}$ holder which was made of reflection mirror and sample. Formed the surface relief structures were investigated using optical microscope. The diffraction efficiency was obtained by measuring +lst order intensity. In addition we investigated grating formation and diffraction efficiency as a function of polarization states which is linear or circular polarization. The results indicate that the grating was formed by linear polarized beam is better clear than that by circular polarized beam.

  • PDF

다중 채널 심장전기도 주 증폭기를 위한 필터 설계 (The design of filters for multi-channel cardiac activation main amplifier)

  • 한영오
    • 한국전자통신학회논문지
    • /
    • 제5권2호
    • /
    • pp.180-184
    • /
    • 2010
  • 본 논문에서는 다중 채널 심장 전기도 주 증폭기의 중요한 부분인 필터를 설계하고 시뮬레이션을 통하여 성능을 분석하였다. 주 증폭기는 샘플/홀더, 가변 고역통과 필터, 노치 필터, 가변 저역통과 필터로 구성된다. 필터는 기존의 64 채널의 공간 분해능을 향상시키기 위하여 128채널을 고려하여 설계되었다.

동축 슬롯 선로를 이용한 기준 용액들의 이동 통신 주파수帶에서의 복소 유전율 측정 (Complex Permittivity Measurement using a Coaxial Slotted Line of Reference Liquids at Mobile Communication Frequencies)

  • 김정호;김윤명
    • 한국전자파학회논문지
    • /
    • 제14권9호
    • /
    • pp.955-960
    • /
    • 2003
  • 본 논문에서는 이동 가능한 프로브(probe)가 있는, 종단된 동축 슬롯 선로(Coaxial slotted line)를 샘플 液의 흘더로 사용하여, 이동 통신 단말기 의 송신 주파수帶에서의 복소 유전율을 측정할 수 있는 시스템을 제작하였으며, 이를 이용하여 IEEE Std 1528-200X에 서 제안한 기준 액체들(Reference Liquids)의 복소 유전율을 측정 비교하여 봄으로써, 측정 시스템의 타당성을 조사하였다.

밀리미터파 전파특성 분석용 샘플홀더 제작 (Manufacturing of Sample Holder for the Property Analysis in Millimeter Wave Range)

  • 최창묵;임봉택
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 추계학술대회
    • /
    • pp.311-314
    • /
    • 2010
  • 본 논문에서는 밀리미터파 대역 전파특성 분석용 샘플홀더 제작을 위하여 전파의 도파이론을 정립하고 밀리미터파 W-bnad(75 GHz ~ 110 GHz) 주파수 대역에 알맞은 도파관형 샘플홀더를 설계 및 실 제작하였다. 그리고 제작된 샘플홀더를 테스트하기 위하여 샘플시료를 제작하여 재료정수 및 전파흡수능을 측정하고 분석하였다. 분석결과 샘플시료 특성을 정확하게 측정할 수 있음을 확인하였으며, 향후 이 측정 샘플홀더는 밀리미터파 대역 전파특성 분석을 위해 매우 유용하게 쓰일 수 있을 것이다.

  • PDF

통전가열과 접촉냉각이 가능한 교환시료 고정장치의 고안 (A Design of Transferable Sample Holder for Resistive Heating and Conductive Cooling)

  • 서재명;김기정;임삼호;구세정;박찬;김영기
    • 한국진공학회지
    • /
    • 제2권3호
    • /
    • pp.288-293
    • /
    • 1993
  • 통전가열, 접촉냉각, 전기적 bias 및 시료 교환을 자유로이 할 수 있는 다기능의 새롭고 간단한 시료 고정장치를 저온 및 초고진공 상태에서 기체와 여러 방향의 시료표면 사이의 상호작용을 연구하기 위하여 고안하였다. 이 장치로써 2분 이내에 기판의 온도를 1600K에서 20K로 2분 이내에 냉각시킬 수 있었다. 그러므로 청결한 표면위에 수소나 He이나 Ne을 제외하고는 대부분의 기체를 흡착시킬 수 있게 되었다. 이러한 장치는 표면에서의 상변화, 기체와 표면의 화학반응의 연구에 중요하게 활용될 수 있다.

  • PDF

타격조건에 따른 수박의 음파특성 (Acoustic Characteristics of Watermelon According to Impact Conditions)

  • 최동수;최규홍;이영희;이강진;김만수
    • Journal of Biosystems Engineering
    • /
    • 제27권1호
    • /
    • pp.67-76
    • /
    • 2002
  • This study was conducted to investigate the effects of impact conditions on the acoustic characteristics of a watermelon. The study was crucial to develop a device for nondestructive internal quality evaluation of a watermelon by an acoustic impulse response method. An impact device was constructed with a pendulum to hit the watermelon, a microphone to detect the acoustic impulse responses, and a digital oscilloscope and computer to store and analyze the data. The selected samples were Guemcheon cultivar watermelons(Citrulus Vulgaris Schrad) harvested on Oct. 20,1998. Sixty watermelons were tested on flour different types of sample holders, with four kinds of ball made of different materials, at four bevels of the angular position of the pendulum and distance from the watermelon to the microphone. Since the magnitudes of frequencies obtained by hitting with the steel and rubber ball were relatively small at the bandwidths of above 500 Hz, it was shown that the steel and rubber ball were not suitable far a hitting ball in the pendulum to get informations on internal quality of the watermelon. In case of using broth of the wood and acryl ball, almost the same and good acoustic responses were shown on the wide range of frequency bandwidth. Therefore, it seemed that the acryl ball was more suitable to the test than the wood ball in considering its mechanical properties. The acoustic characteristics of the watermelon were not shown a significant difference between the types of sample holder. The amplitudes of the acoustic signals and the magnitudes of frequencies from the whole samples increased with increase of the angular position of pendulum and with decrease of the distance from the watermelon to the microphone. However, the resonance resonance of the sample were almost the same regardless of the angular positions and the distances.

산물벼 함수율 측정을 위한 $2{\times}2$ 마이크로스트립 패치 안테나 개발 (A $2{\times}2$ Microstrip Patch Antenna Array for Moisture Content Measurement of Paddy Rice)

  • 김기복;김종헌;노상하
    • Journal of Biosystems Engineering
    • /
    • 제25권2호
    • /
    • pp.97-106
    • /
    • 2000
  • To develop the grain moisture meter using microwave free space transmission technique, a 10.5GHz microwave signal with the power of 11mW generated by an oscillar with a dielectric resonator is transmitted to an isolator and radiated from a transmitting $2{\times}2$ microstrip patch array antenna into the sample holder filled with the 12 to 26%w.b. of Korean Hwawung paddy rice. the microwave signal, attenuated through the grain with moisture, is collected by a receiving $2{\times}2$ microstrip patch array antenna and detected using a Shottky diode with excellent high frequency characteristic. A pair of light and simple microstrip patch array antenna for measurement of grain moisture content is designed and implemented on atenflon substrate with trleative dielectric constant of 2.6 and thickness of 0.54 by using Ensemble ver. 4.02 software. The aperture of microstrip patch arrays is 41 mm width and 24mm high. The characteristics of microstrip patch antenna such as grain. return loss, and bandwidth are 11.35dBi, -38dB and 0.35GHz($50^{\circ}$ at far-field pattern of E and H plane. The width of the sample holder is large enough to cover the signal between the antennas temperature and bulk density respectively. The calibration model for measurement of grain moisture content is proposed to reduce the effects of fluectuations in bulk density and temperature which give serious errors for the measurements . From the results of regression analysis using the statistically analysis method, the moisture content of grain samples (MC(%)) is expressed in terms of the output voltage(v), temperature (t), and bulk density of samples(${\rho}b$)as follows ;$$MC(%)\;=\;(-3.9838{\times}10^{-8}{\times}v^{3}+8.023{\times}10^{-6}{\times}v^{2}-0.0011{\times}v-0.0004{\times}t+0.1706){\frac{1}{{\rho}b}}{\times}100$ Its determination coefficient, standard error of prediction(SEP) and bias were found to be 0.9855, 0.479%w.b. and -0.0.369 %w.b. respectively between measured and predicted moisture contents of the grain samples.

  • PDF

X-Ray Diffraction Analysis of Various Calcium Silicate-Based Materials

  • An, So-Youn;Lee, Myung-Jin;Shim, Youn-Soo
    • 치위생과학회지
    • /
    • 제22권3호
    • /
    • pp.191-198
    • /
    • 2022
  • Background: The purpose of this study was to evaluate the composition of the crystal phases of various calcium silicate-based materials (CSMs): ProRoot white MTA (mineral trioxide aggregate) (WMTA), Ortho MTA (OM), Endocem MTA (EM), Retro MTA (RM), Endocem Zr (EN-Z), BiodentineTM (BD), EZ-sealTM (EZ), and OrthoMTA III (OM3). Methods: In a sample holder, 5 g of the powder sample was placed and the top surface of the material was packed flat using a sterilized glass slide. The prepared slides were mounted on an X-ray diffraction (XRD) instrument (D8 Advance; Bruker AXS GmbH, Germany). The X-ray beam 2θ angle range was set at 10~90° and scanned at 1.2° per minute. The Cu X-ray source set to operate at 40 kV and 40 mA in the continuous mode. The peaks in the diffraction pattern of each sample were analyzed using the software Diffrac (version 2.1). Then, the peaks were compared and matched with those of standard materials in the corresponding Powder Diffraction File (PDF-2, JCPDS International Center for Diffraction Data). A powder samples of the materials were analyzed using XRD and the peaks in diffraction pattern were compared to the Powder Diffraction File data. Results: Eight CSMs showed a similar diffraction pattern because their main component was calcium silicate. Eight CSMs showed similar diffraction peaks because calcium silicate was their main component. Two components were observed to have been added as radiopacifiers: bismuth oxide was detected in WMTA, OM, and EM while zirconium oxide was detected in RM, EN-Z, BD, EZ, and OM3. Unusual patterns were detected for the new material, OM3, which had strong peaks at low angles. Conclusion: It was caused by the presence of Brushite, which is believed to have resulted in crystal growth in a particular direction for a specific purpose.

MOISTURE CONTENT MEASUREMENT OF POWDERED FOOD USING RF IMPEDANCE SPECTROSCOPIC METHOD

  • Kim, K. B.;Lee, J. W.;S. H. Noh;Lee, S. S.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.II
    • /
    • pp.188-195
    • /
    • 2000
  • This study was conducted to measure the moisture content of powdered food using RF impedance spectroscopic method. In frequency range of 1.0 to 30㎒, the impedance such as reactance and resistance of parallel plate type sample holder filled with wheat flour and red-pepper powder of which moisture content range were 5.93∼-17.07%w.b. and 10.87 ∼ 27.36%w.b., respectively, was characterized using by Q-meter (HP4342). The reactance was a better parameter than the resistance in estimating the moisture density defined as product of moisture content and bulk density which was used to eliminate the effect of bulk density on RF spectral data in this study. Multivariate data analyses such as principal component regression, partial least square regression and multiple linear regression were performed to develop one calibration model having moisture density and reactance spectral data as parameters for determination of moisture content of both wheat flour and red-pepper powder. The best regression model was one by the multiple linear regression model. Its performance for unknown data of powdered food was showed that the bias, standard error of prediction and determination coefficient are 0.179% moisture content, 1.679% moisture content and 0.8849, respectively.

  • PDF

Ebert-Fastie spectrograph using the Transformable Reflective Telescope kit

  • Ahn, Hojae;Mo, Gyuchan;Jung, Hyeonwoo;Choi, Junwhan;Kwon, Dou Yoon;Lee, Minseon;Kim, Dohoon;Lee, Sumin;Park, Woojin;Lee, Ho;Park, Kiehyun;Kim, Hyunjong;Pak, Soojong
    • 천문학회보
    • /
    • 제45권1호
    • /
    • pp.40.4-40.4
    • /
    • 2020
  • Kyung Hee university invented the Transformable Reflective Telescope (TRT) for optical experiment and education. The TRT kit can transform into three optical configurations from Newtonian to Cassegrain to Gregorian by exchanging the secondary mirror. We designed the Ebert-Fastie spectrograph as an extension of the TRT kit. The primary mirror of the TRT kit serves as both collimator and camera lens, and the reflective grating as the dispersing element is placed along the optical axis of the primary mirror. We designed and fabricated the grating holder and the source units using 3D printer. Baffle was also fabricated to suppress the stray light, which was reduced by 83%. The spectrograph can observe the optical wavelength range (4000Å~7000Å). Measured resolving power (R=λ/Δλ) was ~700 with slit width of 0.18mm. The spectrograph is optimized for f/24, and the spectral pixel scale is 0.49Å/pixel with Canon 550D detector. We present the sample spectra of discharged Ne, Ar and Kr gases. The flexible setting and high performance make this spectrograph a useful tool for education and experiment.

  • PDF