• Title/Summary/Keyword: salicylate

Search Result 161, Processing Time 0.024 seconds

COMPARISON OF THE INFLUENCE OF CANAL CURVATURE ON THE SEALING ABILITY OF LATERAL CONDENSATION AND SYSTEM BTM (측방가압법과 System BTM를 이용한 근관충전시 근관만곡도에 따른 폐쇄효과의 비교)

  • Lim, Dong-Yeul;Lee, Hee-Joo;Hur, Buck
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.3
    • /
    • pp.482-489
    • /
    • 1999
  • The purpose of this study was to compare sealing ability between lateral condensation and continuous wave of condensation in depend of root canal curvature. In this study, we divided fifty-six human molar teeth into two group in depend of Schneider method, and then subdivided them into four experimental group (each group is composed of twelve teeth) by canal curvature and obturation method, and eight teeth were served as positive and negative controls. Specimens were prepared by Quantac 2000 series file and obturated by lateral condensation or System B. Specimens were immersed in india ink for 7 days, decalcified by 10% nitric acid, dehydrated by 75, 95 and 100% alcohol in order, cleared by methyl salicylate and then measured of dye penetration with stereomicroscope(${\times}6.5$ magnification) and Image Pro plus. The data were analyzed stastically by one-way ANOVA and Scheffe test. The data were as follows: 1. The mean leakage was $0.725{\pm}1.167$ for group A, $0.813{\pm}0.921$ for group B, $0.809{\pm}0.997$ for group C, $1.111{\pm}1.147$ for group D, but no significant difference among them(p>0.05). 2. Lateral condensation had better sealing ability than continuous wave of condensation, but no significant difference among them(p>0.05). 3. There was no significant difference between root canal curvature degree and microleakage(p>0.05).

  • PDF

Development of a Fluoride-Selective Electrode based on Scandium(III) Octaethylporphyrin in a Plasticized Polymeric Membrane

  • Kang, Young-Jea;Lutz, Christopher;Hong, Sung-A;Sung, Da-Yeon;Lee, Jae-Seon;Shin, Jae-Ho;Nam, Hak-Hyun;Cha, Geun-Sig;Meyerhoff, Mark E.
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.6
    • /
    • pp.1601-1608
    • /
    • 2010
  • A scandium(III) porphyrin-based fluoride-selective potentiometric sensor and its application in the analysis of hydrofluoric acid is described. Scandium(III) octaethylporphyrin, an ionophore recently developed for the optical fluoride sensor, was employed as a host molecule for the selective binding with fluoride in the plasticized PVC membrane. Nernstian response for $F^-$ between $10^{-4.6}$ to $10^{-1}$ M was observed at a glycine-phosphate buffer (pH 3.0). The selectivity pattern was observed as $F^-$, salicylate $\gg$ $SCN^-$ > $Cl^-$, $Br^-$, $NO_3{^-}$, $ClO_4{^-}$, which is consistent with the binding constant data measured in the plasticized PVC membrane based on a sandwich membrane method. This highly selective and reversible fluoride-sensitive electrode was employed for the analysis of hydrofluoric acid (HF). A disposable differential-type HF sensor was fabricated on the screen-printed electrode and demonstrated its ability to detect the neutral HF in the acidic solution.

Development of Wireless Real-Time Gas Detector System for Chemical Protection Performance Test of Personal Protective Equipment (화생방 보호의 성능평가를 위한 무선 실시간 가스 검출기 개발)

  • Kah, Dong-Ha
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.294-301
    • /
    • 2020
  • Man-In-Simulant Test(MIST) provides a test method to evaluate chemical protective equipments such as protective garments, gloves, footwear and gas mask. The MIST chamber is built to control concentration of chemical vapor that has a activity space for two persons. Non-toxic methyl-salicylate(MeS) is used to simulate chemical agent vapor. We carried out to measure inward leakage MeS vapors by using passive adsorbent dosimeter(PAD) which are placed on the skin at specific locations of the body while man is activity according to the standard procedure in MIST chamber. But more time is required for PADs and there is concern of contamination in PADs by recovering after experiment. Therefore detector for measuring in real time is necessary. In order to analyze in real time the contamination of the personal protective equipment inside the chemical environment, we have developed a wireless real-time gas detector. The detector consists of 8 gas-sensors and 1 control-board. The control-board includes a CPU for processing a signal, a power supply unit for biasing the sensor and Bluetooth-chipset for transmission of signals to external PC. All signals from gas-sensors are converted into digital signals simultaneously in the control-board. These digital signals are stored in external PC via Bluetooth wireless communication. The experiment is performed by using protective equipment worn on manikin. The detector is mounted inside protective equipment which is capable of providing a real-time monitoring inward leakage MeS vapor. Developed detector is demonstrated the feasibility as real-time detector for MIST.

A STUDY ON THE APICAL MICROLEAKAGE OF GLASS IONOMER ROOT CANAL SEALER (Glass Ionomer Root Canal Sealer의 치근단 미세누출에 관한 연구)

  • Lee, So-Young;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.236-246
    • /
    • 1998
  • The purpose of this study was to compare the degree of micro- leakage of new glass ionomer root canal sealer, Ketac-Endo(ESPE Co., Seefeld, Germany) with that of AH-26(De Trey Co., Ltd., U.S.A.). Root canal treatment using K -file, H -file, Gate Glidden drill was conducted on 49 extracted single-rooted teeth. 45 teeth were randomly divided into 3 experimental groups(15 teeth per group) and 4 teeth were used as the control group. Group 1 was used AH -26 sealer with the lateral condensation method for canal filling, group 2 was used Ketac-Endo with the single cone method and group 3 was used Ketac-Endo with the lateral condensation method. The control group was obturated with the single cone method without sealer. The teeth were covered with two coats of nail varnish after 48 hours of obturation. The teeth were immersed in India ink for 1 week and cleaned with methyl salicylate and then the degree of dye penetration were measured with stereomicroscope. The data were analyzed statistically by one-way ANOVA. The results were as follows: 1. 7 teeth in group 1, 5 in group 2, and 3 in group 3, were showed evidence of microleakage implying appropriate canal filling. 2, The mean average of microleakage was $0.17{\pm}0.32mm$ in group 1, $0.30{\pm}0.37mm$ in group 2. $0.10{\pm}0.21mm$ in group 3, showing that canal filling using the lateral condensation canal filling method with Ketac-Endo showed the least microleakage and using the single cone method with Ketac-Endo showed the largest amount of microleakage, 3. There were no statistically significant difference in the variation of microleakage among groups. From the results above, Ketac-Endo which has the advantage of glass ionomer, whether using the single cone method or the lateral condensation method, showed similar results as AH-26, but for clinical application it is thought that were studies on the properties of Ketac-Endo should be followed.

  • PDF

A STUDY ON THE EFFECT OF MOISTURE ON APICAL SEALING PROPERTY OF ROOT CANAL (근관충전 시 수분오염이 치근단 폐쇄성에 미치는 영향에 관한 연구)

  • Lim, Sung-Sam;Kang, Myung-Whai
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.628-634
    • /
    • 1996
  • The purpose of this study was to investigate the effect of moisture on apical sealing properties of root canal. Fifty five single rooted human teeth were selected from maxillary and mandibular teeth. After removing crown portion at the cemento-enamel junction, all teeth were routinely prepared with step-back method. And then, the canals were dried with paper point and the teeth were randomly divided into 3 groups of 15 teeth each, and remaining 10 teeth were used as positive and negative control teeth : Group 1 were irrigated with 1ml of 95% alcohol and dried with air and paper point. Group 2 and 3 were intentionally contaminated with 0.05ml of 3.5% NaOCl or saliva, respectively. All the teeth were obturated with sealapex and gutta percha cone by lateral condensation technique, and covered with two coat of nail varnish after 48 hours of obturation. The teeth were immersed in india ink for 1 week and cleaned with methyl salicylate and then the degree of dye penetration were measured with stereomicroscope. The data were analyzed statistically by one-way ANOVA. The results were as follows : 1. All experimental groups showed varying degrees of dye penetration, and the mean degree of dye penetration was 0.1mm to 0.7mm. 2. Saliva contamination group(group 3) showed the highest amount of dye penetration, followed by NaOCl contamination group, then alcohol dried group, but there was no significant difference among three experimental groups. * This results suggest that there was no significant differences of apical leakage after canal obturation between alcohol dried canal and moisture present canals and the use of alcohol instead of paper point is unnecessary to dry the canals prior to canal filling. But other factors such as bacterial contamination and sealer discoloration by moisture must be considered in application of this results to clinical practice.

  • PDF

A STUDY ON THE SEALING ABILITY OF THE THERMAFIL ENDODONTIC OBTURATION TECHNIQUE (Thermafil 충전법의 근관폐쇄성에 관한 연구)

  • Park, Chan-Je;Yo, In-Ho;Lim, Sung-Sam
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.517-529
    • /
    • 1996
  • The purpose of this study was to evaluate the apical sealing ability of the Thermafil endodontic obturation technique and to compare it with lateral condensation technique. 42 straight canals from extracted human anterior teeth and 42 curved canals(> $25^{\circ}$) from maxillary and mandibular molar teeth were selected. And 80 of them were divided into four groups, 20 canals respectively. The teeth in prior two groups had straight canals and the other two groups had curved canals. The rest of four canals served as positive and negative controls. After resecting anatomical crowns, all canals were prepared using a standard step-back technique. Lateral condensation was used to obturate two groups, one group of straight ones the other curved. And Thermafil obturators were also used in the same two groups. Obturated teeth were infiltrated by India ink for a week, decalcified and cleared with 5% nitric acid and methyl salicylate. The apical leakage and the frequency of filled lateral and accessory canals were measured with stereomicroscope and also apical extrusion of sealer and gutta-percha and obturation time were checked and the data were analyzed statistically(one-way ANOVA, t-test, Chi-square test). The results were as follows : 1. There was no significant difference in the degree of dye penetration between Thermafil and lateral condensation groups(p>0.05). 2. Apical extrusion of sealer and gutta-percha occurred significantly more often with Thermafil obturators in straight canals(p<0.05), but not significantly different in curved canals(p>0.05). 3. Canal obturation time with Thermafil obturators was significantly faster than lateral condensation (p<0.05). 4. The Thermafil groups showed a higher frequency of filled lateral and accessory canals than in the lateral condensation groups. But the difference was not statistically significant (p>0.05).

  • PDF

Evaluation of Single and Binary Mixture Toxicity of Organic UV-Filters Using H295R Cells (H295R 세포를 활용한 유기 UV-Filters의 단일 및 혼합독성 평가)

  • Bomee Lee;Inhye Lee;Kyunghee Ji
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.3
    • /
    • pp.201-211
    • /
    • 2024
  • Background: Organic ultraviolet (UV) filters are widely used in sunscreen products and have been identified as an emerging contaminant. Organic UV filters co-exist with multiple components, but their mixture toxicity remains largely unknown. Objectives: We investigated the toxicity of single and binary mixtures of commonly used UV-filters using the human adrenocarcinoma (H295R) cell line. Methods: After exposure to non-cytotoxic concentrations of avobenzone (AVO), homosalate (HS), octisalate (OS), octinoxate (OMC), and octocrylene (OC), the levels of testosterone (T) and 17β-estradiol (E2) were measured. The median effective concentration (EC50) values for the E2 of the individual substances were used to determine the mixture effect of four binary combinations: OMC+AVB, OMC+HS, OMC+OS, and OMC+OC. The synergistic, additive, and antagonistic effects of the mixture were determined by calculating toxic units (TU). To examine the mechanism of mixture toxicity, eight genes involved in steroidogenesis were analyzed using the real-time polymerase chain reaction. Results: The significant increase in E2 in H295R cells exposed to AVO, HS, OS, OMC, and OC suggest an estrogenic effect of the tested UV-filters. A significant decrease in T was observed in cells exposed to HS and OS. EC50 values for E2 increase were 105 nM for AVO, 110 nM for HS, 120 nM for OS, 55 nM for OMC, and 80 nM for OC. Both binary mixtures consisting of OMC+HS and OMC+OS have synergistic effects. Conclusions: Our results showed that five types of UV-filter substances increase E2 in H295R cells. We examined the mixture toxicity in terms of increased estrogenicity and confirmed that E2 significantly increased when OMC was mixed with a salicylate-based UV-filters. These findings highlight the importance of determining the impact of UV filter mixtures.

Comparative Genome analysis of the Genus Curvibacter and the Description of Curvibacter microcysteis sp. nov. and Curvibacter cyanobacteriorum sp. nov., Isolated from Fresh Water during the Cyanobacterial Bloom Period

  • Ve Van Le;So-Ra Ko;Mingyeong Kang;Seonah Jeong;Hee-Mock Oh;Chi-Yong Ahn
    • Journal of Microbiology and Biotechnology
    • /
    • v.33 no.11
    • /
    • pp.1428-1436
    • /
    • 2023
  • The three Gram-negative, catalase- and oxidase-positive bacterial strains RS43T, HBC28, and HBC61T, were isolated from fresh water and subjected to a polyphasic study. Comparison of 16S rRNA gene sequence initially indicated that strains RS43T, HBC28, and HBC61T were closely related to species of genus Curvibacter and shared the highest sequence similarity of 98.14%, 98.21%, and 98.76%, respectively, with Curvibacter gracilis 7-1T. Phylogenetic analysis based on genome sequences placed all strains within the genus Curvibacter. The average nucleotide identity (ANI) and digital DNA-DNA hybridization (dDDH) values between the three strains and related type strains supported their recognition as two novel genospecies in the genus Curvibacter. Comparative genomic analysis revealed that the genus possessed an open pangenome. Based on KEGG BlastKOALA analyses, Curvibacter species have the potential to metabolize benzoate, phenylacetate, catechol, and salicylate, indicating their potential use in the elimination of these compounds from the water systems. The results of polyphasic characterization indicated that strain RS43T and HBC61T represent two novel species, for which the name Curvibacter microcysteis sp. nov. (type strain RS43T =KCTC 92793T=LMG 32714T) and Curvibacter cyanobacteriorum sp. nov. (type strain HBC61T =KCTC 92794T=LMG 32713T) are proposed.

Sodium Salicylate(NaSaL) Induces Apoptosis of NCI-H1299 Lung Carcinoma Cells via Activation Caspase-3 Protease (NCI-H1299 폐암 세포주에서 Caspase-3 Protease 활성을 통한 Sodium Salicylate(NaSaL)의 세포고사)

  • Shim, Hyeok;Yang, Sei-Hoon;Bak, Sang-Myeon;Jeong, Eun-Taik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.5
    • /
    • pp.485-496
    • /
    • 2002
  • Background : Nonsteroidal anti-inflammatory drugs (NSAIDs) are useful in the chemoprevention of colon cancers. Continuous NSAID use results in a 40% to 50% reduction in the relative risk of colorectal cancer. The precise mechanism by which NSAIDs prevent and/or cause the regression of colorectal tumors is not known. Some investigators have reported that certain NSAIDs induce apoptosis and alter the expression of the cell cycle regulatory genes in some carcinoma cells when administered at a relatively high concentration. However, the possibility of NSAIDs application as chemopreventive agents in lung cancers remains to be elucidated. To address this question, the human lung cancer cell line NCI-H1299 was used to investigate whether or not NSAIDs might induce the apoptotic death of NCI-H1299 cells. Methods : A viability test was carried out using a MTT assay. Apoptosis was measured by flow cytometric analysis and unclear staining(DAPI). The talytic activity of the caspase family was measured by the fluirigenic cleavage of biosubstrates. To define the mechanical basis of apoptosis, western blot was performed to analyze the expression of the death substrates(PARP and ICAD). Results : NaSaL significantly decreased the viability of the NCI-H1299 cells, which was revealed as apoptosis characterized by an increase in the $subG_0/G_1$ population and unclear fragmentation. The catalytic activity of caspase-3 protease began to increase after 24 Hr and reached a peak 30 Hr after treatment with 10 mM NaSaL. In contrast, caspase-6, 8, and 9 proteases did not have a significantly altered enzymatic activity. Consistent with activation of caspase-3 protease, NaSaL induced the cleavage of the protease biosubstrate. Conclusion : NaSaL induces the apoptotic death of NCI-H1299 human lung cancer cells via the activation of caspase-3 protease.

A Study of Reportable Range Setting through Concentrated Control Sample (약물검사에서 관리시료의 농축을 이용한 보고 가능 범위의 설정에 대한 연구)

  • Chang, Sang Wu;Kim, Nam Yong;Choi, Ho Sung;Park, Yong Won;Yun, Keun Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.1
    • /
    • pp.13-18
    • /
    • 2004
  • This study was designed to establish working range for reoportable range in own laboratory in order to cover the upper and lower limits of the range in test method. We experimented ten times during 10 days for setting of reportable range with between run for method evaluation. It is generally assumed that the analytical method produces a linear response and that the test results between those upper and lower limits are then reportable. CLIA recommends that laboratories verify the reportable range of all moderate and high complexity tests. The Clinical Laboratory Improvement Amendments(CLIA) and Laboratory Accreditation Program of the Korean Society for Laboratory Medicine states reportable range is only required for "modified" moderately complex tests. Linearity requirements have been eliminated from the CLIA regulations and from others accreditation agencies, many inspectors continue to feel that linearity studies are a part of good lab practice and should be encouraged. It is important to assess the useful reportable range of a laboratory method, i.e., the lowest and highest test results that are reliable and can be reported. Manufacturers make claims for the reportable range of their methods by stating the upper and lower limits of the range. Instrument manufacturers state an operating range and a reportable range. The commercial linearity material can be used to verify this range, if it adequately covers the stated linear interval. CLIA requirements for quality control, must demonstrate that, prior to reporting patient test results, it can obtain the performance specifications for accuracy, precision, and reportable range of patient test results, comparable to those established by the manufacturer. If applicable, the laboratory must also verify the reportable range of patient test results. The reportable range of patient test results is the range of test result values over which the laboratory can establish or verify the accuracy of the instrument, kit or test system measurement response. We need to define the usable reportable range of the method so that the experiments can be properly planned and valid data can be collected. The reportable range is usually defined as the range where the analytical response of the method is linear with respect to the concentration of the analyte being measured. In conclusion, experimental results on reportable range using concentrated control sample and zero calibrators covering from highest to lowest range were salicylate $8.8{\mu}g/dL$, phenytoin $0.67{\mu}g/dL$, phenobarbital $1.53{\mu}g/dL$, primidone $0.16{\mu}g/dL$, theophylline $0.2{\mu}g/dL$, vancomycine $1.3{\mu}g/dL$, valproic acid $3.2{\mu}g/dL$, digitoxin 0.17ng/dL, carbamazepine $0.36{\mu}g/dL$ and acetaminophen $0.7{\mu}g/dL$ at minimum level and salicylate $969.9{\mu}g/dL$, phenytoin $38.1{\mu}g/dL$, phenobarbital $60.4{\mu}g/dL$, primidone $24.57{\mu}g/dL$, theophylline $39.2{\mu}g/dL$, vancomycine $83.65{\mu}g/dL$, valproic acid $147.96{\mu}g/dL$, digitoxin 5.04ng/dL, carbamazepine $19.76{\mu}g/dL$, acetaminophen $300.92{\mu}g/dL$ at maximum level.

  • PDF