• Title/Summary/Keyword: sagA

Search Result 562, Processing Time 0.029 seconds

Identification of Mutations in Protein Kinase CKIIβ Subunit That Affect Its Binding to Ribosomal Protein L41 and Homodimerization

  • Ahn, Bong-Hyun;Lee, Ji-Hoon;Bae, Young-Seuk
    • BMB Reports
    • /
    • v.36 no.4
    • /
    • pp.344-348
    • /
    • 2003
  • Protein kinase CKII is composed of two catalytic ($\alpha$ or $\alpha$') subunits and two regulatory ($\beta$) subunits. The $CKII{\beta}$ subunit is thought to mediate the tetramer formation and interact with other target proteins. However, its physiological function remains obscure. In this study, point mutants of $CKII{\beta}$ that are defective for the L41 binding were isolated by using the reverse two-hybrid system. A sequence analysis of the point mutants revealed that Asp-26, Met-52, and Met-78 of $CKII{\beta}$ are critical for L41 binding; Asn-67 (and/or Lys-139) and Met-52 are important for $CKII{\beta}$ homodimerization. Two point mutants, R75 and R83, of $CKII{\beta}$ interacted with L5, topoisomerase $II{\beta}$, and CKBBP1/SAG, but not with the wild-type $CKII{\beta}$. This indicates that $CKII{\beta}$ homodimerization is not a prerequisite for its binding to target proteins. These $CKII{\beta}$ point mutants may be useful in exploring the biochemical physiological functions of $CKII{\beta}$.

Quantitative Analysis and Comparisons between In-Phase Control and Energy-Optimized Control for Series Power Quality Controllers

  • Xinming, Hunag;Jinjun, Liu;Hui, Zhang
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.553-566
    • /
    • 2009
  • In-phase control and energy-optimized control are the two major control strategies proposed for series power quality controllers (SPQC). However quantitative analysis and comparison between these two control strategies is quite limited in previous publications. In this paper, an extensive quantitative analysis is carried out on these two control strategies through phasor diagram approach, and a detailed quantitative comparison is conducted accordingly. The load current is used as the reference phasor, and this leads to a simpler and clearer phasor diagram for the quantitative relationship. Subsequently detailed analysis of SPQC using in-phase control and energy-optimized control are provided respectively, under different modes both for under voltage/voltage sag and for over voltage/voltage swell. The closed form analytic expressions and the curves describing SPQC compensation characteristics are obtained. The detailed system power flow is figured out for each mode, and the detailed quantitative comparison between the two control strategies is then carried out. The comparison covers several aspects of SPQC, such as required compensating voltage magnitude, required capacity of energy storage component, and maximal ride-through time. In the end, computer simulation and prototype experimental results are shown to verify the validity of all the analysis and the result of the comparison.

Study on Tension and Thermal Properties of Corrosive-fractured Steel Sleeve (강 슬리브 파단 직선 슬리브의 장력 및 열적 특성 분석 연구)

  • Ahn, Sang-Hyun;Kim, Byung-Geol;Kim, Sang-Shu;Sohn, Hong-Kwan;Kim, In-Pyo;Kim, Sung-Kyu
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.11
    • /
    • pp.1036-1041
    • /
    • 2008
  • According to previous report, aged sleeves of old transmission line showed several defaulted installation patterns, which was biased or corrosive-fractured of steel sleeve installed cases. These defects can cause serious accidents such as rapid increasing of sag or falling out of overhead conductor from sleeves. Consequently, the defects lead to the major power outage. Corrosion of steel sleeve is a typical defect by aging of sleeves. And it occupied almost 25 percent of investigated aged sleeves. This paper studied thermal properties and tension for ACSR conductor in case of fractured steel sleeve model by corrosion. The temperature distribution within overhead conductor has a specific gradient. Thermal properties of splice connectors(sleeve and clamp) showed normal behavior. However, mechanical properties were worse than normal sleeves. The detailed results were presented in the text.

The Analysis of Trolley-Rail Short Circuit Current in a Single Track AT Feeding System (단선 AT 급전계통의 전차선-레일 단락 고장전류 분석)

  • Cho, Gyu-Jung;Ryu, Kyu-Sang;Lee, Hun-Do;Heo, Seung-Hun;Kim, Chul-Hwan;Kwon, Sung-Il;Kim, Cheol-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1659-1665
    • /
    • 2015
  • In general, AT(Auto-transformer) is used to improve voltage sag and inductive interference in power lines and communication lines in AC electrical railway feeding system. Especially, Korean AT feeding system has different composition compared to other countries like Japan or France, so that it has some special characteristics. However, relays imported from other countries have been used in Korea, and settings of these relays should be modified and reflect distinct characteristics of Korean AT feeding system. Therefore, study about fault analysis based on modeled AT feeding system is important. In this paper, we modeled a single track AT feeding system by using PSCAD and analyzed fault current flow in case of trolley-rail short circuit fault. Finally, we presented current magnitude of each branch expressed by boosting current of AT.

A study on the welding performance of korean automatic gas pressure welding machine by external appearance investigation (외관검사를 통한 한국형 철근자동가스압접기의 압접성능 연구)

  • Seo, Deok-Seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.6
    • /
    • pp.161-166
    • /
    • 2008
  • This study is focused on the welding performance of automatic gas pressure welding machine adapted to korean construction site by external appearance investigation. As gas pressure welding is more economical and has good performances compared with other steel bar jointing methods, as arc welding and mechanical joint etc, in Japan, the gas pressure welding is one of the typical connection of steel reinforcement when connecting the D29 and thicker steel bars, But in Korea, gas pressure welding joint method is not widely used caused by the shortage of skilled workers. so to activate the gas pressure welding in Korea, the automatic gas pressure welding machine is developed. In this study, the welding performances of gas pressure welding joint samples using korean automatic gas pressure welding machine are measured by external appearance investigation - blown diameters, blown length, welding face disagreement, central axis eccentric ratio, bending, sag and crack. The results of welding performances on the gas pressure welding joint samples show that samples are satisfied with the standard value regulated in KS D 0244 and JIS Z 3120.

Analysis of Transient Characteristics for Distributed Generations with the Secondary Feeders (저압배전선로에 연계된 분산전원의 과도특성 해석에 관한 연구)

  • Yoon, Gi-Gab;Rho, Dae-Seok;Kim, Eui-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3898-3904
    • /
    • 2010
  • In order to analyze the transient characteristics for distributed generation located with the secondary feeders, this paper constructs a Distributed Generations Filed Test Center which can produce transient characteristics such as voltage sag, swell, interruption, harmonic and so on. And also this paper proposes the test results for the interconnection of distributed generations. The results show the effectiveness for the utility technical guidelines for distributed generations with the secondary feeders.

Present Condition of High Capacity & Low Sag Overhead Transmission Development (증용량 & 저이도 가공송전 개발 현황)

  • Kim, Dong-Hoon;Choi, A-Leum;Kang, Seung-Hun;Hong, Dong-Suk;Shim, Jeong-Woon;Kim, Dong-Hee;Lee, Dong-Il;Shin, Koo-Yong;Kim, Byung-Geol
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.576-577
    • /
    • 2011
  • 이상기후 변화에 따라 전력 수요량이 매년 증가하는 추세에 따른 전력 보유량이 줄어들고 있는 실정이다. 5차 전력수급 계획에 따르면 전력 소비량에 비해 전력공급 설비 증가량이 매우 부족한 실정이다. 이에 기존의 가공송전선인 ACSR에 전력송전 용량을 증가시킬 수 있는 방안으로 알루미늄 도체에 합금 원소를 첨가하여 특성을 향상시키나, 도체의 형상을 Round Type에서 Trapezoidal Type으로 변경함에 따라 도체의 점적률을 약 20~25% 향상시킴으로 전력송전 용량을 향상시킨 증용량 가공송전선 개발이 진행되고 있다. 또한 지지선을 고강도, 비자성 특성을 갖는 강선 및 고강도, 저 선팽창계수 특성을 갖는 복합재료를 사용함으로써 가공송전선의 이도 특성을 향상시킨 가공선 개발이 활발히 진행되고 있다.

  • PDF

Customer Nodal Cost Calculation considering Power Quality (전력품질을 고려한 수용가 모선 가격 계산)

  • Jeong, Sung-Won;Park, In-Duck;Gim, Jae-Hyeon;Lee, Geun-Joon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.3
    • /
    • pp.82-87
    • /
    • 2007
  • This paper measures power quality of bus in case electric charges about customer are imposed by each bus, supposed that can calculate this cost. When reflected this in system planning, expected cost proposed following method through sample system. To calculate nodal cost operating condition of power equipment calculates nodal cost[$/MVAH] supposing by situation that is optimized by OPF(optimal power flow) in system. The damage cost that is shed by fault that happen during year of loads in system that is linked on each bus was produced. As a result, proposed method was very effective in case of calculating bus total cost including power quality cost.

Anti-islanding Detection Method for BESS Based on 3 Phase Inverter Using Negative-Sequence Current Injection (역상분 전류 주입을 적용한 3상 인버터 기반 BESS의 단독 운전 검출 방법)

  • Sin, Eun-Suk;Kim, Hyun-Jun;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1315-1322
    • /
    • 2015
  • This paper proposes an active islanding detection method for the BESS (Battery Energy Storage System) with 3-phase inverter which is connected to the AC grid. The proposed method adopts the DDSRF (Decoupled Double Synchronous Reference Frame) PLL (Phase Locked-Loop) so that the independent control of positive-sequence and negative-sequence current is successfully carried out using the detected phase angle information. The islanding state can be detected by sensing the variation of negative-sequence voltage at the PCC (Point of Common Connection) due to the injection of 2-3% negative-sequence current from the BESS. The proposed method provides a secure and rapid detection under the variation of negative-sequence voltage due to the sag and swell. The feasibility of proposed method was verified by computer simulations with PSCAD/EMTDC and experimental analyses with 5kW hardware prototype for the benchmark circuit of islanding detection suggested by IEEE 1547 and UL1741. The proposed method would be applicable for the secure detection of islanding state in the grid-tied Microgrid.

A Real-time Symmetric Component Sequence Analysis Algorithm for Power Quality Analysis (전력품질 분석을 위한 대칭성분 실시간 추종에 관한 연구)

  • Park, Jin-Soo;You, Jin-Ho;Ahn, Jae-Young;Park, Il-Ho;Cheon, Young-Sig
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.187-188
    • /
    • 2015
  • 본 논문은 시간영역에서 대칭좌표법을 사용한 전력품질 이벤트 검출에 관한 연구이다. sag, swell. interruption, harmonic, flicker, transients, notches, spike 등과 같은 전력품질 이벤트들이 이 방법으로 쉽게 검출된다. 본 방법은 웨이블릿, s-변환, 힐버트 변환 등의 방법이 가지고 있는 계산 부담이 없기 때문에 온라인 응용프로그램에 쉽게 사용될 수 있다. 단상 전력품질 이벤트 신호는 시간 영역에서 대칭요소를 계산하기 위하여 120도, 240도 위상차를 가지고 생성되는 다른 두 신호와 함께 이동되어 간다. 전력품질 이벤트 신호의 시작점(triggering point)은 역상분으로부터 쉽게 검출될 수 있고 이벤트는 정상분과 역상분의 합을 사용한 파형의 특징 분석으로 쉽게 분류될 수 있다. 시뮬레이션된 결과는 전력품질 이벤트의 검출과 분류를 위한 본 방법의 효과를 보여주기 위하여 다수의 전력품질 이벤트를 보여주고 있고 전력계통망 지락사고 시뮬레이션을 수행하여 유용성을 확인하였다.

  • PDF