• 제목/요약/키워드: safety switch

검색결과 165건 처리시간 0.025초

Anomaly detection of isolating switch based on single shot multibox detector and improved frame differencing

  • Duan, Yuanfeng;Zhu, Qi;Zhang, Hongmei;Wei, Wei;Yun, Chung Bang
    • Smart Structures and Systems
    • /
    • 제28권6호
    • /
    • pp.811-825
    • /
    • 2021
  • High-voltage isolating switches play a paramount role in ensuring the safety of power supply systems. However, their exposure to outdoor environmental conditions may cause serious physical defects, which may result in great risk to power supply systems and society. Image processing-based methods have been used for anomaly detection. However, their accuracy is affected by numerous uncertainties due to manually extracted features, which makes the anomaly detection of isolating switches still challenging. In this paper, a vision-based anomaly detection method for isolating switches, which uses the rotational angle of the switch system for more accurate and direct anomaly detection with the help of deep learning (DL) and image processing methods (Single Shot Multibox Detector (SSD), improved frame differencing method, and Hough transform), is proposed. The SSD is a deep learning method for object classification and localization. In addition, an improved frame differencing method is introduced for better feature extraction and a hough transform method is adopted for rotational angle calculation. A number of experiments are conducted for anomaly detection of single and multiple switches using video frames. The results of the experiments demonstrate that the SSD outperforms the You-Only-Look-Once network. The effectiveness and robustness of the proposed method have been proven under various conditions, such as different illumination and camera locations using 96 videos from the experiments.

RCD 접점형태에 따른 산화특성 분석 (The Analysis of Oxidization Characteristics according to the shapes of RCD contacts)

  • 김동우;김향곤;길형준;한운기;최충석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.576-577
    • /
    • 2005
  • In this paper, the oxidization characteristics were analyzed according to the shapes of Residual Current Protective Device(RCD) contacts. RCD is an electrical safety device specially designed to immediately switch the electricity off when electric leakage is detected at a level harmful to a person using electrical equipment. The shapes of RCD contacts are a little bit different according to the models. When RCD is turned on, stationary and moving contact do not fit together. So, it can cause the increase of contact resistance. To discover the deterioration characteristics of RCD contacts by switching repetition, the contacts were analyzed by stereo microscope, Scanning Electron Microscope(SEM) and Energy Dispersive X-ray Spectrometer(EDS).

  • PDF

단상 MJ81 전기선로전환기 국산품의 현장설치시험 (The Site Installation Test of Single-Phase MJ81 Switch Point Machine Localization)

  • 백종현;김용규
    • 한국산학기술학회논문지
    • /
    • 제10권12호
    • /
    • pp.3632-3637
    • /
    • 2009
  • 본 논문에서는 단상 MJ81 전기선로전환기의 실용화를 위해 요구되는 현장설치시험을 수행한 결과를 기술하고 있다. 이러한 단상 MJ81 전기선로전환기는 경부고속철도 건설시에 프랑스 알스톰 및 코지프로부터 기술이전 받아 국산화한 3상 MJ81 전기선로전환기를 단상 220V를 사용하고 있는 국내 기존선에서도 선로 연변 전원설비의 변경 없이도 사용할 수 있도록 구동부의 성능 개선을 통해 공인인증시험을 통과한 제품이다. 한국철도기술연구원 및 삼성 SDS에서는 기존철도기술개발사업을 통해 기존선의 속도 및 안전성 향상을 위해 단상 MJ81 전기선로전환기를 국산화 하였으나 이의 실용화를 위해서는 연동장치와의 인터페이스 시험 뿐 아니라 실제 선로에서의 현장설치시험을 통해 성능을 입증하여야 한다. 본 논문에서는 이러한 시험을 진행한 과정과 함께 현장설치시험의 결과 분석을 통해 국산품인 단상 MJ81 전기선로전환기의 실용성을 입증하였으며, 입증된 결과를 바탕으로 2009년 2월 한국철도시설공단의 물량을 수주하여 현재 설치 중이다.

저압용 누전차단기의 스위칭에 따른 아크 비산 및 접점의 특성분석 (The analysis of arc dispersion and contacts characteristics according to switching of RCD for low voltage)

  • 김동우;김향곤;길형준;한운기;최충석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.69-73
    • /
    • 2005
  • The arc dispersion and contacts characteristics were analyzed according to switching off Residual Current Protective Device(RCD) switch. Arc dispersion process was taken by high speed imaging system at a rate of 10,000 frames per second. When RCD was switched from on to off, art was observed and it took about 2.3[ms] from the generation of arc to the extinction of arc. When RCD was switched from off to on, arc was not observed. We repeated switching on and off 1000, 3000 and 6000 times. After repetition, the surface characteristics of contacts were taken by stereo microscope and Scanning Electron Microscope(SEM). From the scattering patterns analysis of arc and the analysis of deteriorated contacts, it could be applicable to the research of electric fire and arc suppression.

  • PDF

산업현장의 천장크레인 조작장치 사용 현황과 인간공학적 문제점 (Overhead Crane Controllers and Ergonomic Problems in Industrial Field)

  • 박재희;김승희
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.90-97
    • /
    • 2017
  • Overhead cranes are the most widely used and have been identified as one of the main causes of fatal accidents. Although structural, mechanical and electrical safety standards for overhead cranes have been established to some extent, ergonomic standards related to crane controllers are rarely established. As a result, many crane accidents are reported to be caused by operator's error. To investigate the actual use of crane controllers in the industrial field, we surveyed 82 overhead cranes in 15 workplace and interviewed workers operating them. This study has presented the ergonomic problems related to the crane controllers in the field. As a result of investigation, it was found that the direction control signs, the sign language, and the button layout on the pendant switches and remote controllers are not standardized, which can cause a human error. To reduce human errors in overhead crane operation, ergonomic standards for controllers should be reflected on the government legislation or standards.

국외 수변전실 및 지상 전력기기 침수방지 대책에 관한 조사연구 (The analysis for flooding prevention countermeasures of Electrical facility and Transformer Vault on Foreign)

  • 김기현;이상익;전현재;배석명;이재용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.305-307
    • /
    • 2008
  • Inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-tying shore by heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical equipment (Pad-mounted Transformer and Switch). So we research the flooding prevention countermeasures of electrical facility and Transformer Vault on Foreign. We conform the site facility and related regulation for flooding prevention on Foreign.

  • PDF

공정안전용 Polymer PTC 소재의 제조 및 특성 (Preparation and Properties of Polymer PTC Composites for Process Safety)

  • 강영구;조명호
    • 한국안전학회지
    • /
    • 제18권3호
    • /
    • pp.101-108
    • /
    • 2003
  • Polymeric positive temperature coefficient(PTC) composites have been prepared by incorporating carbon black(CB) into high density polyethylene(HDPE), polyphenylene sulfide(PPS) and polybutylene terephthalate(PBT) matrices. A PTC effect was observed in the composite, caused by the large thermal expansion due to He consecutive melting of HDPE, PPS and PBT crystallites. This theory is based upon the premise that the PTC phenomenon is due to a critical separation distance between carbon particles in the polymer matrix at the higher temperature. The influence of PTC characteristics of the PPS/CB composite can be explained by DSC result. HDPE, one of prepared composition, exhibit the higher performance PTC behavior that decreaseing of negative temperature coefficient(NTC) effect and improved reproducibility by chemically crosslinking. Also, PBT/CB and PPS/CB composites exhibit the higher PTC peack temperature than HDPE/CB PTC composite, individually $200^{\circ}C$ and $230^{\circ}C$. These PTC composite put to good use in a number of safety application, such as self$.$controlled heater, over-current protectors, auto resettable switch, high temperature proctection sensor, etc.

소음과 불꽃을 제거한 단상유도전동기의 아날로그식 기동기 설계 (Analogue type Starter of Single Phase Induction Motor Removing Noise and Arc)

  • 박수강;조금배;백형래;임양수;이성길;임종연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.654-656
    • /
    • 2001
  • This research used triac that is semi-conductor that act to static contact to overcome happened shortcoming been using mechanical centrifugal force switch usually Detect starting current of single phase induction motor and decided moving time. Therefore, could improve life of switch semipermanently. Also, wish to reduced impact that electric motor suffers at the starting moment and do stable starting which there is no life improvement and noise of electric motor itself, arc.

  • PDF

A Study on the Stem Coefficient of Friction of Motor- operated Gate/Globe halves

  • Jeoung, Rae-Hyuck;Park, Sung-Keun;Lee, Do-Hwan;Kim, Yang-Seok
    • Nuclear Engineering and Technology
    • /
    • 제35권2호
    • /
    • pp.133-143
    • /
    • 2003
  • Stem-stem nut coefficient of friction(COF) in motor-operated gate/globe valves is one of the important factors which determine the performance of the valve/actuators. The COF is affected greatly by the type and condition of the stem-stem nut lubricants, environmental parameters, surface condition of the stem/stem-nuts, and the number of strokes after the lubrication. In this paper, the measured data of the COFs at stem threads of some safety-related motor-operated gate/globe valves in domestic nuclear power plants are presented. In addition, the performance of the lubricants is evaluated by comparing the COFs among those valves. The results show that the measured COF at torque switch trip are higher than the unwedging COF and conservatively applicable to the unwedging COF. It is also shown that the lubricating performance based on the measured COFs varies with the lubricants.

Analyzing Safety Factors of Swimming Pool

  • KWON, Yeon Taek;SEO, Myung Seok;SEO, Won Jae
    • Journal of Sport and Applied Science
    • /
    • 제5권1호
    • /
    • pp.11-15
    • /
    • 2021
  • Purpose: Swimming industry is improving faster than the other types of sport industries and populations of participating swimming are promptly increasing. Lack of recognition of fire safety in swimming facilities is issues related-studies has only recently begun to pay attention. This study is to review and extract fire safety factors for managing swimming pool. Research design, data, and methodology: The study reviewed related-ordinances, governmental documents, and studies discussing safety management of sport facility. Given the literature review, the study produced an initial construct presenting items and factors including fire safety elements and experts' review were conducted to ensure conceptual validity. Finally, the study generated the final factors and subitems representing fire safety elements for swimming pool management. Results: The study confirms factors and elements as follows: the study identifies fire safety equipments as first factors presenting fire extinguisher' place, its proper run, check list and so forth, Second factor is warning system including fire warning equipment, its proper operation, sprinkler and its proper operation, switch and lamp of emergency panel and their proper run and so on. Third factor is evacuation system including a fire exit, exit sign, broadcasting equipment, and their proper operation, and so on. The other factors are an electronic equipment and its subelements, gas management including safety management of LPG, gas valve, pipe, and fire prevention facility including a fire door and its proper operating. Conclusions: Regarding safety management of swimming pool, further discussions and implications were made, and future directions for related-studies were discussed.