• Title/Summary/Keyword: safety switch

Search Result 165, Processing Time 0.022 seconds

Anomaly detection of isolating switch based on single shot multibox detector and improved frame differencing

  • Duan, Yuanfeng;Zhu, Qi;Zhang, Hongmei;Wei, Wei;Yun, Chung Bang
    • Smart Structures and Systems
    • /
    • v.28 no.6
    • /
    • pp.811-825
    • /
    • 2021
  • High-voltage isolating switches play a paramount role in ensuring the safety of power supply systems. However, their exposure to outdoor environmental conditions may cause serious physical defects, which may result in great risk to power supply systems and society. Image processing-based methods have been used for anomaly detection. However, their accuracy is affected by numerous uncertainties due to manually extracted features, which makes the anomaly detection of isolating switches still challenging. In this paper, a vision-based anomaly detection method for isolating switches, which uses the rotational angle of the switch system for more accurate and direct anomaly detection with the help of deep learning (DL) and image processing methods (Single Shot Multibox Detector (SSD), improved frame differencing method, and Hough transform), is proposed. The SSD is a deep learning method for object classification and localization. In addition, an improved frame differencing method is introduced for better feature extraction and a hough transform method is adopted for rotational angle calculation. A number of experiments are conducted for anomaly detection of single and multiple switches using video frames. The results of the experiments demonstrate that the SSD outperforms the You-Only-Look-Once network. The effectiveness and robustness of the proposed method have been proven under various conditions, such as different illumination and camera locations using 96 videos from the experiments.

The Analysis of Oxidization Characteristics according to the shapes of RCD contacts (RCD 접점형태에 따른 산화특성 분석)

  • Kim, Dong-Woo;Kim, Hyang-Kon;Gil, Hyoung-Jun;Han, Woon-Kim;Choi, Chung-Seog
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.576-577
    • /
    • 2005
  • In this paper, the oxidization characteristics were analyzed according to the shapes of Residual Current Protective Device(RCD) contacts. RCD is an electrical safety device specially designed to immediately switch the electricity off when electric leakage is detected at a level harmful to a person using electrical equipment. The shapes of RCD contacts are a little bit different according to the models. When RCD is turned on, stationary and moving contact do not fit together. So, it can cause the increase of contact resistance. To discover the deterioration characteristics of RCD contacts by switching repetition, the contacts were analyzed by stereo microscope, Scanning Electron Microscope(SEM) and Energy Dispersive X-ray Spectrometer(EDS).

  • PDF

The Site Installation Test of Single-Phase MJ81 Switch Point Machine Localization (단상 MJ81 전기선로전환기 국산품의 현장설치시험)

  • Baek, Jong-Hyen;Kim, Yong-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3632-3637
    • /
    • 2009
  • In this paper, we describe the performance results of the field installation test which is required to practicalize the single-phase MJ81 Switch Point Machine. This product has passed the certified test through performance improvement of driving parts in order to use 3 phase MJ81 Switch Point Machine, which is localized by taking over technology from Alstom and Cogifer when constructing Seoul-Busan rapid-transit railway, without change of the electrical equipment at track-side in domestic existing lines which single-phase 220V is used. KRRI and Samsung SDS have localized the single-phase MJ81 Switch Point Machine to improve the speed and safety of the conventional lines through the existing railway technology development project. For practicalization of this, we should, however, verify the performance through not only field installation test in real lines but also interface test with the interlocking. In this paper we verify the practicality of the domestic single-phase MJ81 Switch Point Machine through analysis on the performance result of the field installation test as well as the research contents for this test. Thereby, in Feb 2009 we have received an order from the Korea Rail Network Authority and are currently installing the single-phase MJ81 Switch Point Machine.

The analysis of arc dispersion and contacts characteristics according to switching of RCD for low voltage (저압용 누전차단기의 스위칭에 따른 아크 비산 및 접점의 특성분석)

  • Kim, Dong-Woo;Kim, Hyang-Kon;Gil, Hyung-Jun;Han, Woon-Ki;Choi, Chung-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.69-73
    • /
    • 2005
  • The arc dispersion and contacts characteristics were analyzed according to switching off Residual Current Protective Device(RCD) switch. Arc dispersion process was taken by high speed imaging system at a rate of 10,000 frames per second. When RCD was switched from on to off, art was observed and it took about 2.3[ms] from the generation of arc to the extinction of arc. When RCD was switched from off to on, arc was not observed. We repeated switching on and off 1000, 3000 and 6000 times. After repetition, the surface characteristics of contacts were taken by stereo microscope and Scanning Electron Microscope(SEM). From the scattering patterns analysis of arc and the analysis of deteriorated contacts, it could be applicable to the research of electric fire and arc suppression.

  • PDF

Overhead Crane Controllers and Ergonomic Problems in Industrial Field (산업현장의 천장크레인 조작장치 사용 현황과 인간공학적 문제점)

  • Park, Jae Hee;Kim, Seung Hee
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.1
    • /
    • pp.90-97
    • /
    • 2017
  • Overhead cranes are the most widely used and have been identified as one of the main causes of fatal accidents. Although structural, mechanical and electrical safety standards for overhead cranes have been established to some extent, ergonomic standards related to crane controllers are rarely established. As a result, many crane accidents are reported to be caused by operator's error. To investigate the actual use of crane controllers in the industrial field, we surveyed 82 overhead cranes in 15 workplace and interviewed workers operating them. This study has presented the ergonomic problems related to the crane controllers in the field. As a result of investigation, it was found that the direction control signs, the sign language, and the button layout on the pendant switches and remote controllers are not standardized, which can cause a human error. To reduce human errors in overhead crane operation, ergonomic standards for controllers should be reflected on the government legislation or standards.

The analysis for flooding prevention countermeasures of Electrical facility and Transformer Vault on Foreign (국외 수변전실 및 지상 전력기기 침수방지 대책에 관한 조사연구)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Jean, Hyun-Jae;Bae, Suk-Myong;Lee, Jae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.305-307
    • /
    • 2008
  • Inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-tying shore by heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical equipment (Pad-mounted Transformer and Switch). So we research the flooding prevention countermeasures of electrical facility and Transformer Vault on Foreign. We conform the site facility and related regulation for flooding prevention on Foreign.

  • PDF

Preparation and Properties of Polymer PTC Composites for Process Safety (공정안전용 Polymer PTC 소재의 제조 및 특성)

  • 강영구;조명호
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.3
    • /
    • pp.101-108
    • /
    • 2003
  • Polymeric positive temperature coefficient(PTC) composites have been prepared by incorporating carbon black(CB) into high density polyethylene(HDPE), polyphenylene sulfide(PPS) and polybutylene terephthalate(PBT) matrices. A PTC effect was observed in the composite, caused by the large thermal expansion due to He consecutive melting of HDPE, PPS and PBT crystallites. This theory is based upon the premise that the PTC phenomenon is due to a critical separation distance between carbon particles in the polymer matrix at the higher temperature. The influence of PTC characteristics of the PPS/CB composite can be explained by DSC result. HDPE, one of prepared composition, exhibit the higher performance PTC behavior that decreaseing of negative temperature coefficient(NTC) effect and improved reproducibility by chemically crosslinking. Also, PBT/CB and PPS/CB composites exhibit the higher PTC peack temperature than HDPE/CB PTC composite, individually $200^{\circ}C$ and $230^{\circ}C$. These PTC composite put to good use in a number of safety application, such as self$.$controlled heater, over-current protectors, auto resettable switch, high temperature proctection sensor, etc.

Analogue type Starter of Single Phase Induction Motor Removing Noise and Arc (소음과 불꽃을 제거한 단상유도전동기의 아날로그식 기동기 설계)

  • Park Su-Kang;Cho Geum-Bae;Baek Hyung-Lae;Lim Yang-Su;Lee Sung-Kil;Lim Jong-Yeun
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.654-656
    • /
    • 2001
  • This research used triac that is semi-conductor that act to static contact to overcome happened shortcoming been using mechanical centrifugal force switch usually Detect starting current of single phase induction motor and decided moving time. Therefore, could improve life of switch semipermanently. Also, wish to reduced impact that electric motor suffers at the starting moment and do stable starting which there is no life improvement and noise of electric motor itself, arc.

  • PDF

A Study on the Stem Coefficient of Friction of Motor- operated Gate/Globe halves

  • Jeoung, Rae-Hyuck;Park, Sung-Keun;Lee, Do-Hwan;Kim, Yang-Seok
    • Nuclear Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.133-143
    • /
    • 2003
  • Stem-stem nut coefficient of friction(COF) in motor-operated gate/globe valves is one of the important factors which determine the performance of the valve/actuators. The COF is affected greatly by the type and condition of the stem-stem nut lubricants, environmental parameters, surface condition of the stem/stem-nuts, and the number of strokes after the lubrication. In this paper, the measured data of the COFs at stem threads of some safety-related motor-operated gate/globe valves in domestic nuclear power plants are presented. In addition, the performance of the lubricants is evaluated by comparing the COFs among those valves. The results show that the measured COF at torque switch trip are higher than the unwedging COF and conservatively applicable to the unwedging COF. It is also shown that the lubricating performance based on the measured COFs varies with the lubricants.

Analyzing Safety Factors of Swimming Pool

  • KWON, Yeon Taek;SEO, Myung Seok;SEO, Won Jae
    • Journal of Sport and Applied Science
    • /
    • v.5 no.1
    • /
    • pp.11-15
    • /
    • 2021
  • Purpose: Swimming industry is improving faster than the other types of sport industries and populations of participating swimming are promptly increasing. Lack of recognition of fire safety in swimming facilities is issues related-studies has only recently begun to pay attention. This study is to review and extract fire safety factors for managing swimming pool. Research design, data, and methodology: The study reviewed related-ordinances, governmental documents, and studies discussing safety management of sport facility. Given the literature review, the study produced an initial construct presenting items and factors including fire safety elements and experts' review were conducted to ensure conceptual validity. Finally, the study generated the final factors and subitems representing fire safety elements for swimming pool management. Results: The study confirms factors and elements as follows: the study identifies fire safety equipments as first factors presenting fire extinguisher' place, its proper run, check list and so forth, Second factor is warning system including fire warning equipment, its proper operation, sprinkler and its proper operation, switch and lamp of emergency panel and their proper run and so on. Third factor is evacuation system including a fire exit, exit sign, broadcasting equipment, and their proper operation, and so on. The other factors are an electronic equipment and its subelements, gas management including safety management of LPG, gas valve, pipe, and fire prevention facility including a fire door and its proper operating. Conclusions: Regarding safety management of swimming pool, further discussions and implications were made, and future directions for related-studies were discussed.