• Title/Summary/Keyword: safety standard and work method

Search Result 112, Processing Time 0.034 seconds

A Lattice-Based Monte Carlo Evaluation of Canada Deuterium Uranium-6 Safety Parameters

  • Kim, Yonghee;Hartanto, Donny;Kim, Woosong
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.642-649
    • /
    • 2016
  • Important safety parameters such as the fuel temperature coefficient (FTC) and the power coefficient of reactivity (PCR) of the CANada Deuterium Uranium (CANDU-6) reactor have been evaluated using the Monte Carlo method. For accurate analysis of the parameters, the Doppler broadening rejection correction scheme was implemented in the MCNPX code to account for the thermal motion of the heavy uranium-238 nucleus in the neutron-U scattering reactions. In this work, a standard fuel lattice has been modeled and the fuel is depleted using MCNPX. The FTC value is evaluated for several burnup points including the mid-burnup representing a near-equilibrium core. The Doppler effect has been evaluated using several cross-section libraries such as ENDF/B-VI.8, ENDF/B-VII.0, JEFF-3.1.1, and JENDL-4.0. The PCR value is also evaluated at mid-burnup conditions to characterize the safety features of an equilibrium CANDU-6 reactor. To improve the reliability of the Monte Carlo calculations, we considered a huge number of neutron histories in this work and the standard deviation of the k-infinity values is only 0.5-1 pcm.

An Experimental Study on the Application for High Pressure Spray by Heat Cycle Type Equipment to Improve Work Safety and Workability of Asphalt Water Proofing method. (아스팔트 방수공법의 시공성 및 작업안전성 개선을 위한 열순환 방식의 고압 분사장치 적용에 관한 실험적 연구)

  • Chung, Chang-Pyo;Song, Je-Young;Lee, Sun-Kyu;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.33-39
    • /
    • 2009
  • Asphalt waterproofing method has a long history over 80years since introduce to domestic market. This method has a good point as high water proofing not permeable to water by material performance of bitumen, In spite of high waterproofing, the application has become decreased. This asphalt method has some problem such as work safety, low workability by complicated work process, environmental problem in job site, it should be solve by complementary measures. 'Therefore, in this paper, suggest the principle of high pressure spray by heat cycle type equipment by analysis of exist problem and materials investigation. And. study and examine the spray type degeneration rubberized asphalt membrane materials to adopt job site. Moreover, suggest the evidence by inspection about waterproofing performance by Korean Industrial Standard through the performance test of the spray type degeneration rubberized asphalt membrane materials.

  • PDF

A Study on the Design/construction Standard of Unlined Tunneling Method (Unlined Tunnel 공법 지보재의 설계 및 시공 기준 고찰)

  • 서영화;김성구;나승훈
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.121-134
    • /
    • 2002
  • Tunneling is a very dangerous and expansive work. Especially, the concrete lining works need many long hours and much cost. As an alternative, the unlined tunneling methods including NMT have been developed in various country. These methods have advantages in cost, time and quality. In Korea, many considerations have been conducted to apply the unlined tunneling method in comparatively good rock. Since primary reinforcements play the role of the final supporting system in unlined tunnels, the initial stiffness and long term durability of reinforcements are very important for tunnel safety. To establish the reinforcements standard suitable to Korea, we investigated the foreign standards and construction cases, comparing geological and construction conditions of foreign land and Korea. As the result, we have proposed the standard of primary supporting system for unlined tunnel in aspects of material, design, construction and quality control etc.

  • PDF

A Study on the Development of Safety Management Manual for Private Museums (사립 박물관 안전관리 매뉴얼 개발에 관한 연구)

  • Song, Changyoung
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.607-616
    • /
    • 2019
  • Purpose: The purpose of this study is to development of standard manual for safety management in private museums. Method: For this purpose. Fifty private museums in the KOREA have been selected. and Interviewed experts to investigate problems in safety management work. Result: The results of study are as followed: 1)The improvement measures for the problems of safety management are derived. 2)It was survey that the staff responsible in safety managers for safety management needs education. Conclusion: Therefore, the standard procedure for scenario-based safety management using figures and charts was proposed.

Factors Affecting Nurses' Performance of Standard Precautions for Infection in Public Medical Institutions: Focusing on Knowledge and Safety Environment (공공의료기관 간호사의 감염 표준주의지침 수행도 영향요인 : 지식, 안전환경 중심으로)

  • Lee, Ji-in;Kim, Jong Kyung
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.7
    • /
    • pp.238-247
    • /
    • 2021
  • This study is a descriptive research to investigate the, safety environment, and performance of nurses working in public medical institutions on standard precautions for infection, and to identify factors affecting the performance of standard precautions for infection. As for the research method, data were collected through a questionnaire on 192 nurses from two public medical institutions in S city and N city, and the results were analyzed using the SPSS WIN 22.0 statistical program. From the research results, there was a significant difference in the knowledge of standard precautions according to work experience, and there was a significant difference in the safety environment of standard precautions according to the position. The average level of knowledge of standard precautions was 21.98/25 points, the average safety environment was 5.68/7 points, and the average performance was 40.28/60 points. There was a significant positive correlation between the safety environment of standard precautions and the performance of standard precautions (r=.21, p<0.01). The affecting factor on the performance of standard precautions was found to be the safety environment of standard precautions(𝛽=.22, p=.003). Therefore, to improve the performance of standard precautions for nurses' infection control in public medical institutions, Different and persistent infection management educational programs that consider the Historical situation and monitoring are required other than providing financial support and supportive safety environment.

Relation between Multiple Markers of Work-Related Fatigue

  • Volker, Ina;Kirchner, Christine;Bock, Otmar L.
    • Safety and Health at Work
    • /
    • v.7 no.2
    • /
    • pp.124-129
    • /
    • 2016
  • Background: Work-related fatigue has a strong impact on performance and safety but so far, no agreed upon method exists to detect and quantify it. It has been suggested that work-related fatigue cannot be quantified with just one test alone, possibly because fatigue is not a uniform construct. The purpose of this study is therefore to measure work-related fatigue with multiple tests and then to determine the underlying factorial structure. Methods: Twenty-eight employees (mean: 36.11; standard deviation 13.17) participated in five common fatigue tests, namely, posturography, heart rate variability, distributed attention, simple reaction time, and subjective fatigue before and after work. To evaluate changes from morning to afternoon, t tests were conducted. For further data analysis, the differences between afternoon and morning scores for each outcome measure and participant (${\Delta}$ scores) were submitted to factor analysis with varimax rotation and each factor with the highest-loading outcome measure was selected. The ${\Delta}$ scores from tests with single and multiple outcome measures were submitted for a further factor analysis with varimax rotation. Results: The statistical analysis of the multiple tests determine a factorial structure with three factors: The first factor is best represented by center of pressure (COP) path length, COP confidence area, and simple reaction time. The second factor is associated with root mean square of successive difference and useful field of view (UFOV). The third factor is represented by the single ${\Delta}$ score of subjective fatigue. Conclusion: Work-related fatigue is a multidimensional phenomenon that should be assessed by multiple tests. Based on data structure and practicability, we recommend carrying out further studies to assess work-related fatigue with manual reaction time and UFOV Subtest 2.

The Effects of Reinforcing in Concrete Crack by AIG Method (Auto Injector Grouting을 이용한 콘크리트 균열 보강효과)

  • Oh, Se-Wook;Youn, Il-Ro;Cho, Hong-Dong
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.79-84
    • /
    • 2008
  • Auto injector grouting method as low pressure injected by using epoxy and Boyle's law is very excellent method in economical efficiency and construction work because injected process can be dealt with collectively. For estimation of filling capacity purpose of this study compared the Auto injector method with the piston injector method. In this study, the tests allow for width of crack, injected angle of epoxy resin and injected method were performed using concrete block specimen making artificial crack. The results of test, tilling et1iciency of epoxy by Auto Injector grouting method verify to better than the piston injector method and uniaxial strength increased about 11% than standard specimen.

Laboratorial technique for fabrication of outer diameter stress corrosion cracking on steam generator tubing (증기발생기 전열관 2차측 응력부식균열의 실험실적 모사 방법)

  • Lee, Jae-Min;Kim, Sung-Woo;Hwang, Seong-Sik;Kim, Hong-Pyo;Kim, Hong-Deok
    • Corrosion Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.112-119
    • /
    • 2014
  • In this work, it is aimed to develop the fabrication method of axial stress corrosion cracking (SCC) defects having various sizes, on the outer diameter surface of the steam generator (SG) tubings. To control the length of the artificial SCC defect, the specific area of the SG tubing samples was exposed to an acidic solution after a sensitization heat treatment. During the exposure to an acidic solution, a direct current potential drop (DCPD) method was adopted to monitor the crack depth. The size of the SCC defect was first evaluated by an eddy current test (ECT), and then confirmed by a destructive examination. From the comparison, it was found that the actual crack length was well controlled to be similar to the length of the surface exposed to an acidic solution (5, 10, 20 or 30 mm in this work) with small standard deviation. From in-situ monitoring of the crack depth using the DCPD method, it was possible to distinguish a non-through wall crack from a through wall crack, even though the depth of the non-through wall crack was not able to be precisely controlled. The fabrication method established in this work was useful to simulate the SCC defect having similar size and ECT signals as compared to the field cracks in the SG tubings of the operating Korean PWRs.

A Comparative Study on the Regulation of Explosive Noise in Demolition Work at Home and abroad (국내외 철거작업시 발파소음 규제에 대한 비교 연구)

  • Ki-Taek Oh
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.984-992
    • /
    • 2023
  • Purpose: The core problem of this study is that there are no specific noise regulation standards for domestic blasting work. Currently, the domestic blasting work noise regulation standard has not been established separately, and the noise regulation standard of 80 decibels is corrected by 10 decibels to 70 decibels, which is the daily living noise standard. In contrast, many foreign countries have separate noise regulation standards specifically tailored to blasting work. Accordingly, it is intended to present international reasonable blasting noise standards by comparing domestic and foreign blasting work noise regulation standards. Mmethod: This study can be inferred as a comparative analysis of domestic and foreign noise regulation standards. Data on the current noise regulation standards during domestic blasting and noise regulation standards during blasting operations in the United States, the United Kingdom, Australia, Japan, and China are collected and analyzed. Results: According to the study, the noise regulation value during blasting work at domestic construction sites was not separately established, so it was not properly tailored to the specific and characteristics of blasting noise. In the case of overseas, a realistic noise regulation value was established so that a safer, more efficient and eco-friendly blasting method could be applied to the noise regulation value uniformly during blasting work. Conclusion: In this study, it is hoped that noise regulations will be established during reasonable blasting work, as shown in domestic and international comparative studies, and will be widely adopted without interfering with the introduction of efficient, economical, and eco-friendly blasting methods by complying well with blasting safety standards.

Evaluation of Matrix Effects in Quantifying Microbial Secondary Metabolites in Indoor Dust Using Ultraperformance Liquid Chromatographe-Tandem Mass Spectrometer

  • Jaderson, Mukhtar;Park, Ju-Hyeong
    • Safety and Health at Work
    • /
    • v.10 no.2
    • /
    • pp.196-204
    • /
    • 2019
  • Background: Liquid chromatography-tandem mass spectrometry (LC-MSMS) for simultaneous analysis of multiple microbial secondary metabolites (MSMs) is potentially subject to interference by matrix components. Methods: We examined potential matrix effects (MEs) in analyses of 31 MSMs using ultraperformance LC-MSMS. Twenty-one dust aliquots from three buildings (seven aliquots/building) were spiked with seven concentrations of each of the MSMs ($6.2pg/{\mu}l-900pg/{\mu}l$) and then extracted. Another set of 21 aliquots were first extracted and then, the extract was spiked with the same concentrations. We added deepoxy-deoxynivalenol (DOM) to all aliquots as a universal internal standard. Ten microliters of the extract was injected into the ultraperformance LC-MSMS. ME was calculated by subtracting the percentage of the response of analyte in spiked extract to that in neat standard from 100. Spiked extract results were used to create a matrix-matched calibration (MMC) curve for estimating MSM concentration in dust spiked before extraction. Results: Analysis of variance was used to examine effects of compound (MSM), building and concentration on response. MEs (range: 63.4%-99.97%) significantly differed by MSM (p < 0.01) and building (p < 0.05). Mean percent recoveries adjusted with DOM and the MMC method were 246.3% (SD = 226.0) and 86.3% (SD = 70.7), respectively. Conclusion: We found that dust MEs resulted in substantial underestimation in quantifying MSMs and that DOM was not an optimal universal internal standard for the adjustment but that the MMC method resulted in more accurate and precise recovery compared with DOM. More research on adjustment methods for dust MEs in the simultaneous analyses of multiple MSMs using LC-MSMS is warranted.