표준 바닥재를 이용한 미끄럼 측정기의 검증방법 개선 및 활용방안 (A Study on the Improvement of Validation and Application for Slipmeters using Reference Surfaces)

  • 김정수
    • 한국안전학회지
    • /
    • 제28권6호
    • /
    • pp.73-78
    • /
    • 2013
  • The purpose of this study was to evaluate three kinds of slipmeters (BOT, BPT, English XL) used on-site floor with ASTM F2508 which is comprised of four different standard surfaces(polished granite, glazed porcelain, vinyl composite tile ;VCT, and ceramic tile). ASTM F2508 has two criteria that decide which slipmeter is appropriate or not. The evaluated slipmeters were dreg sled, articulated sturt, and pendulum strike type. The test results revealed that two kinds of slipmeters(BOT, BPT) successfully ranked all four standard surfaces and differentiated among standard surfaces with varying degrees of slipperiness. Nevertheless, the measured value with BOT on the VCT, which was reported as slippery floor in previous study, was higher than its threshold(0.6). Although some slipmeter satisfy two criteria of ASTM F2508, they can underestimate the slip potential. So, another criteria is needed so as to reduce this problem. English XL couldn't properly measure slipperiness under the two kind of floors(glazed porcelain, VCT). So the slider of English XL was modified in order to meet two criteria of ASTM F2508.

규격화된 분전반 제작을 위한 표준작업절차(SOP)의 공정 개발 (Process Development of a Standard Operating Procedure (SOP) for the Manufacturing of Standardized Distribution Boards)

  • 고완수;이병설;최충석
    • 한국안전학회지
    • /
    • 제33권5호
    • /
    • pp.21-27
    • /
    • 2018
  • The purpose of this study is to develop a SOP (Standard Operating Procedure) for a distribution board that can monitor the leakage current of a load distribution line in real time. The developed distribution board was fabricated by applying IEC 61439-1. It consists of the distribution board and an alarm device. The work process for making the distribution board was compliant with the KEMC (Korea Electrical Manufacturers Cooperative) regulations. And the AC distribution board range is 1,000 V. In addition, the voltage in DC is less than 1500 V. The distribution board receives a 3-phases and 4-wires power supply system and can supply power to the load of a maximum of 32 single or three phase distribution circuits. Also, leakage current measured on the power distribution board was used by sensors installed. The SOP of the developed distribution board consists of the installation standards for the short circuit alarm device and sensor, the surge protection device, switches and indication lamps, and other devices. The operation procedure was prepared so that each manufacturing step of the distribution board must be confirmed by the persons in charge of preparation, production, quality control and approval before moving forward to the next step.

반 잠수형 쌍동선에 설치된 수중관람용 관람창 설계 및 구조 안전성 평가 (Structural Safety Assessments for Viewing Window of Semi-Submersible Catamaran)

  • 황세윤;김호성;이경훈;김유일;이장현
    • 대한조선학회논문집
    • /
    • 제51권4호
    • /
    • pp.291-299
    • /
    • 2014
  • In the design process of ship or its comprising components, the key to the successful design is how to guarantee the structural safety satisfying the international standard and regulation, which sometimes is not clear enough to cover the detail designs. This study deals with the design procedure for submersible viewing window installed in catamaran. As the window material, the Plexiglass, a type of reinforced plastic, is considered to satisfy the design requirements of international standard. Window thickness is calculated using geometric nonlinear finite element analysis, in order to take into account possible large deformation due to low stiffness of the Plexiglass, and the results are compared with those determined by the procedure specified in ISO12216. Finally, for the validation of proposed design, the pressure test had been carried out following the procedure specified in the standard, and structural safety was checked.

우리나라의 사업장 위험성평가 제도 실시에 관한 연구 (A Study on the Implementation of Risk Assessment System at Workplace in Korea)

  • 정진우
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.121-128
    • /
    • 2014
  • Risk assessment system which is the point of occupational safety and health management system is recognized to be effective to prevent industrial accident and occupational disease internationally. Ministry of Employment and Labor developed guidance on risk assessment at workplace recently. This guidance presents standard model on risk assessment at workplace. However, enterprises may be confronted with many questions in the process of introducing and operating risk assessment. For risk assessment to be implemented properly and effectively at workplace, there are various questions that need to be considered in advance, including giving shape to standard on risk evaluation and clarifying the implementation system at workplace in advance. Also for risk assessment to be revitalized at workplace, several policy matters need to be settled. First, an administrative agency should present the implementation method of risk assessment more concretely. Secondly, it is necessary for an administrative agency to develop and spread various detailed manual, models and good practices related to risk assessment. Thirdly, a government agency need to apply an incentive & disadvantage policy actively to risk assessment.

비틀림 마운트형 저압 터빈 블레이드의 안전성 평가에 관한 연구 (A Study on the Safety Estimation of Low Pressure Torsion mounted Turbine Blade)

  • 홍순혁;조석수;주원식
    • 한국정밀공학회지
    • /
    • 제20권3호
    • /
    • pp.149-156
    • /
    • 2003
  • The estimation of fatigue limit for the component with complicated shape is difficult than of standard fatigue specimen, due to complex test equipment. So, we substitute maximum principle stress from FEM results for fatigue limit diagram made by standard fatigue specimen. Then we can estimate endurance safety of component with high trust. The static stress analysis, the nonlinear contact stress analysis and the model analysis for turbine blade is performed by ANSYS ver. 5.6. the comparison of maximum static stress around hole with maximum contact stress between pun and hole can make the cause of fracture for turbine blade clear. The difference of fatigue limit between fatigue test by standard specimen and in-service mechanical components is due to surface roughness and machining condition etc. In in-service mechanical components, Goodman diagram has to consider surface roughness for failure analysis. To find fracture mechanism of torison-mounted blade in nuclear plant. This study performs the static stress, the nonlinear contact stress and the modal analysis on torison-mounted blade with finite element method and makes the estimation for safety of turbine blade.

원자력발전소 비안전등급 배관의 내진해석 방법론 연구 (Seismic Analysis Methodology for Non-Nuclear Safety Piping in Nuclear Power Plants)

  • 서건창;반치범
    • 한국압력기기공학회 논문집
    • /
    • 제18권1호
    • /
    • pp.1-10
    • /
    • 2022
  • Currently, there is no technical standard and regulation for seismic analysis of non-nuclear safety piping. Accordingly, ASME Sec.III ND, a standards applied to safety class 3 piping, is applied. However, the technical standard applied for other than seismic analysis is ASME B31, which leads to controversy. In this study, the feasibility of applying ASME B31E was confirmed by reviewing rulescomparing technical standards, and evaluating piping allowable stress margins. The evaluation revealed that applying ASME B31.1 as a technical standard is too conservative compared to ASME Sec.III ND. On the other hand, ASME B31E (issued at the request of the industry) clearly presents the technical standards for seismic analysis of ASME B31 piping, and shows a similar level of conservatism compared to ASME Sec.III ND. It is expected to reduce the controversy over technical standards for seismic analysis of non-nuclear safety piping by applying ASME B31E.

Analysis of IEC 61727 Photovoltaic (PV) systems Characteristics of the utility interface

  • Lee, Jeong Hyeon;Yoon, Yong Ho;Kim, Jae Moon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권2호
    • /
    • pp.90-95
    • /
    • 2015
  • This paper describes IEC 61727 standard of Photovoltaic (PV) systems -Characteristics of the utility interface. IEC 61727 standard tests include utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1) voltage, current and frequency, 2) normal voltage operating range, 3) flicker, 4) DC injection, 5) normal frequency operating range, 6) harmonics and 7) waveform distortion, 8) power factor of PV inverter. Also personnel safety and equipment protection part includes test items 1)loss of utility voltage, 2)over/under voltage and frequency, 3)Islanding protection, 4)response to utility recovery, 5)earthing, 6)short circuit protection, 7)Isolation and switching of PV inverter. In this paper, each item of IEC 61727 standard test is studied and analyzed and finally full tested by PV inverter performance function.

경쟁우위 전략에서의 기업윤리에 관한 연구 (A Study on Business Ethics of Competitive Superiority Strategy)

  • 임웅석;김형준;이내형
    • 대한안전경영과학회지
    • /
    • 제9권1호
    • /
    • pp.157-174
    • /
    • 2007
  • Corporation had been made by important action rule of business ethics that observes legal standard that is prescribed in each class of administration activity. But it does not keep ethicality of corporation action that conforms law. Law can not include all parts of business ethics because it is forcing essential class for public order preservation and public welfare in right. Moreover, partial corporations are doing to justify unethical action of other evasion of taxes, consultation, manufacturing etc. with legal basis meaning abusing legal standard. For these reason, Insistence that is in point of legal standard and ethical standard is not different each other that is in equal viewpoint is brought.

전기철도분야 국제 표준화 흐름에 대응한 한국철도표준규격의 발전 방향 (Advancement Directions for Korean Railway Standard(KRS) Corresponding to the Trend of International Standard in Electric Railway)

  • 이창영;권성태;김정국;백승구;장석각
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.1156-1164
    • /
    • 2006
  • According to Korean railway safety law and its ordinances, the Korean railway standard(KRS)s to recommend railway operators and manufacturers the regulations for safety and inter-operability of railway system were enacted in the early 2006. In order to reflect rapidly advancing railway technologies and correspond to the international railway standard led by Europe and Japan, KRSs should be confirmed and revised continuously. This paper deals with recent trends in enacting international standards by IEC and the Europe and Japan's activities for this, and presents advancement directions for KRS.

  • PDF