• Title/Summary/Keyword: safety requirement

Search Result 722, Processing Time 0.031 seconds

A Study for the Present Conditions and the Service Satisfaction with Hospital Home Care Service (병원가정간호사업 운영 현황 및 서비스 만족도에 관한 연구)

  • Hong, Chun-Sil;Oh, Kyong-Ok;Park, Mi-Young;Sim, Hee-Sook;Cha, Young-Nam
    • Journal of Korean Academic Society of Home Health Care Nursing
    • /
    • v.8 no.2
    • /
    • pp.121-134
    • /
    • 2001
  • The purpose of this study were to analyze the home care services and to evaluate the client's satisfaction with the home care services provided by home care service center in the C hospital. The data were collected by reviewing charts of 128 home care clients who were receiving home care services at C hospital from October 1997 to September 2000. The subjects for satisfaction of home care service were 20 clients from July 10 to September 30, 2000. The tool for measurement of present condition of home care service was developed by the researchers. The satisfactions of the home care services were measured by using the instrument developed by Im(997). The data were analyzed by using the SPSS/PC+. The results of this study were as followings : 1. Majority of the subjects was female(61.7%). The average of age was 63.5 years. The service has been used mostly by the elderly 60 years of age or older(71.1%). The economic level of most of subjects was in middle class(94.5%). 2. Majority of the subject had a cancer(55.4%), following stroke(25.0%). The average duration of disease for the subjects was 31 months. The average time of hospitalization for the subjects was 3.3 times. The duration of hospitalization was 10$\sim$30 days(26.6%), 30$\sim$60 days(23.4%) and above of the 210 days(9.4%). 3. Most of the subjects used his/her doctor (47.7%), as a consultant, following his/her nurse (28.1%), other patients or their family (21.9%). Most of reasons for a consultation were supportive management(Infusion or medication, 60.94%), following tube management(L-tube or T-tube, 25%), Foley catheter management (15.63%) etc. 4. 28 types of nursing diagnoses were used by the home care service. The nursing diagnosis altered nutrition: less than body requirement were used mostly by the home care service, following risk for infection, impaired skin integrity, impaired swallowing, ineffective airway clearance altered comfort: pain, impaired physical mobility. By the human-response pattern, exchanging(63.2%), moving(7.5%), feeling(10.4%), knowing(5.2%), communicating (2.6%), relating(0.5%) perceiving(0.4%) and choosing(0.3%). There were 42 nursing intervention types were performed by the home care service. By the NIC(nursing intervention classification. McCloskey. Bulech. 1996). physiologic: complex (30.3%) was the most, safety(28.3%), behavioral(20.0%), physiologic: basic(10.8%) and health system(1.7%). Observation or assessment was the most nursing intervention performed by the home care service. following IV infusion. vital sign observation. infusion management and fluid-electrolyte balance management. 5. The level of client's satisfaction with provided home care services showed considerably high(2.67/ 3).

  • PDF

3D Track Models Generation and Applications Based on LiDAR Data for Railway Route Management (철도노선관리에서의 LIDAR 데이터 기반의 3차원 궤적 모델 생성 및 적용)

  • Yeon, Sang-Ho;Lee, Young-Dae
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1099-1104
    • /
    • 2007
  • The visual implementation of 3-dimensional national environment is focused by the requirement and importance in the fields such as, national development plan, telecommunication facility deployment plan, railway construction, construction engineering, spatial city development, safety and disaster prevention engineering. The currently used DEM system using contour lines, which embodies national geographic information based on the 2-D digital maps and facility information has limitation in implementation in reproducing the 3-D spatial city. Moreover, this method often neglects the altitude of the rail way infrastructure which has narrow width and long length. There it is needed to apply laser measurement technique in the spatial target object to obtain accuracy. Currently, the LiDAR data which combines the laser measurement skill and GPS has been introduced to obtain high resolution accuracy in the altitude measurement. In this paper, we first investigate the LiDAR based researches in advanced foreign countries, then we propose data a generation scheme and an algorithm for the optimal manage and synthesis of railway facility system in our 3-D spatial terrain information. For this object, LiDAR based height data transformed to DEM, and the realtime unification of the vector via digital image mapping and raster via exactness evaluation is transformed to make it possible to trace the model of generated 3-dimensional railway model with long distance for 3D tract model generation.

  • PDF

A Study on Compressive Strength Estimation of Underwater Concrete Structures According to Water Depths (수중 콘크리트 구조물의 수심별 강도 추정에 관한 연구)

  • Lee, Jisung;Han, Sanghun;Park, Seunghee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.341-348
    • /
    • 2016
  • Harbor facilities require long-term durability and safety, and also maintain the performance requirement until the durability life. However, existing harbor facilities are becoming superannuated with durable years and durability is declined by erosion of the sea and damage from sea. In addition, harbor facilities will be in demand for the expansion of harbor and offshore structures with rising economic power by enhancement of domestic industry and increase of import and export. Therefore, in this study, two kinds of nondestructive test (NDT) techniques (schmidt rebound hammer and ultrasonic sensor) are verified for the effective maintenance of underwater concrete structures including harbor facilities. Sea field applicability of Schmidt hammer and ultrasonic sensor was verified by comparing field test result with sea field test result and also deduced the compressive strength estimation equation by depth of the water. On the basis of the sea field test result, compressive strength estimation equation which was deduced by multiple regression analysis indicated highest accuracy compared to other equations, especially it will be more likely to be used in underwater because of the depth of water correction. In the future, if schmidt hammer and ultrasonic sensor which were invented as waterproofing are used with ROV (Remotely Operated Vehicle), it will be possible to make a diagnosis of high reliability for underwater concrete structures and set up a ubiquitous concept of NDT system.

A study on the characteristics for temporary ventilation of long subsea tunnels - focused on the current situation and improvement requirements (초장대 해저터널의 공사중 환기 특성에 관한 기초연구 - 현황 및 개선필요사항 중심)

  • Jo, Hyeong-Je;Chun, Kyu-Myung;Kim, Jong-Won;Lee, Ju-Kyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.153-166
    • /
    • 2015
  • Long subsea tunnel to be built below the seabed, as compared to the general railway tunnel, is subject to many restrictions in terms of spatial limitation when vertical or inclined shafts are built for the purpose of ventilation and fire safety. So, the construction of some artificial island is required to provide ventilation. But, because of construction difficulty and cost increase, it is necessary to minimize the artificial island construction. The longer ventilation distance is, the more fresh air requirement is needed. When supply airflow becomes excessive, duct size is restricted by the limitations of structure clearance and fan pressure and power increase exponentially. Therefore, in order to build a long subsea tunnel, it is necessary to overcome these practical problems and to develop technical solution that can keep the comfortable condition of tunnel environment during construction. In this study, as on ventilation method development suitable for long subsea tunnel, through comparison of temporary ventilation capacity calculation methods during construction phase, domestic and abroad, the application of Swiss SIA 196 code is found suitable for long subsea tunnel. And, through experiment on leakage of the duct connector, we confirmed that the leakage ratio per 100 m of domestic duct connection type is between 1.5~3.0%. Based on S-class duct of SIA 196 code, ventilation distance is 10.2 km, So, ventilation distance can be longer if duct connection method is improved. So, we confirmed that the improvement of leakage ratio is key issue in the construction-phase ventilation of long subsea tunnel.

Suggestion for the Enhancement of Military Supplies via Segregation of Defense Quality Management System (국방 분야 품질경영시스템 세분화를 통한 군수품 품질향상 방안)

  • Ju, Jin-Chun;Kim, Sung-kon;Lee, Jong-chan;Ahn, Nam-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.251-261
    • /
    • 2016
  • Recently, many weapon related quality issues have arisen in the armed forces, such as failures of K-21 Infantry Fighting Vehicles, K-9 self-propelled mounts, and grenade explosion during boot training. Since all of the issues are repetitive phenomena, we examined the defense quality management system and identified the possible solutions for it. Since the government quality assurance agency performs their quality assurance activity using the system evaluation technique, we first reviewed the regulations related to the defense quality management system. Then, we benchmarked some other advanced quality management systems. We suggested two types of defense quality management system, one for small (in terms of the amount of the contract) competitive contracts and the other for large private contracts. For the first one, we adopted the framework of MIL-I-45208 (Inspection System Requirement), while for the second one, we adopted the framework of NATO AQAP 2310 (Quality Management System Requirements for Aviation, Space and Defense Suppliers).

Analysis on Ventilation Efficiency of Standard Duck House using Computational Fluid Dynamics (전산유체역학을 이용한 표준 오리사 설계안에 대한 환기효율성 분석)

  • Yeo, Uk-Hyeon;Jo, Ye-Seul;Kwon, Kyeong-Seok;Ha, Tae-Hwan;Park, Se-Jun;Kim, Rack-Woo;Lee, Sang-Yeon;Lee, Seung-No;Lee, In-Bok;Seo, Il-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.5
    • /
    • pp.51-60
    • /
    • 2015
  • In Korea, 69.4 % of duck farms had utilized conventional plastic greenhouses. In this facilities, there are difficulties in controlling indoor environments for raising duck. High rearing density in duct farms also made the environmental control difficult resulting in getting more stressed making their immune system weaker. Therefore, a facility is needed to having structurally enough solidity and high efficiency on the environmental control. So, new design plans of duck house have recently been conducted by National Institute of Animal Science in Korea. As a study in advance to establish standard, computational fluid dynamics (CFD) was used to estimate the aerodynamic problems according to the designs by means of overall and regional ventilation efficiencies quantitatively and qualitatively. Tracer gas decay (TGD) method was used to calculate ventilation rate according to the structural characteristics of duck houses including installation of indoor circulation fan. The results showed that natural ventilation rate was averagely 164 % higher than typically designed ventilation rate, 1 AER ($min^{-1}$). Meanwhile, mechanically ventilated duck houses made 81.2 % of summer ventilation rate requirement. Therefore, it is urgent to develop a new duck house considering more structural safety as well as higher efficiency of environmental control.

Field Tracer Experiments under Severe Wether Conditions for the Validation of the Dispersion of Radioactive Materials (방사능 확산 검증을 위한 악기상 조건에서의 추적자 야외확산 실증실험)

  • Han, Moon Hee;Kim, Eun Han;Jeong, Hyo Joon;Jeong, Hae Sun;Park, Mi Sun;Hwang, Won Tae
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.208-213
    • /
    • 2013
  • The suitability of the site criteria is a basic requirement for securing safety of nuclear power plants. The suitability should be confirmed through the estimation of environmental radiation effects at the exclusion area boundary under the severe weather conditions. In this study, field tracer experiments over short range of 1 km radius under severe weather conditions were conducted at flat area in Daejeon. Severe weather conditions are represented with stable atmospheric condition and low wind speed. In general, the condition is appeared at clean night time with weak wind. The analysis of the measured distribution of the released tracer gas shows two big differences between the results of the past experiments conducted under the favorable weather conditions. One is the difficulty of finding the typical distribution of the released tracer gas with peak concentration in the downwind direction. The other one is the appearance of the contour of the concentration of tracer gas at several hundred meters even though the gas released at 10 m height over the ground.

A Survey on Patient's Experience on Health Care Utilization and Perception of Health Care System for Developing of a Korean Medicine Clinical Practice Guideline for Traffic Injuries (교통사고상해증후군 한의표준임상진료지침 개발을 위한 환자의 의료이용 경험과 의료체계 인식도 설문조사 연구)

  • Park, Sun-Young;Lee, Sang-Hyun;Heo, In;Hwang, Man-Suk;Kim, Koh-Woon;Cho, Jae-Heung;Park, Kyoung Sun;Ha, In Hyuk;Shin, Byung-Cheul
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.30 no.2
    • /
    • pp.139-152
    • /
    • 2020
  • Objectives To explore the traffic injury patients' experience on health care utilization of Korean Medicine (KM) practice and perception of health care system for developing a Korean medicine clinical practice guideline (CPG) of traffic injuries by survey method. Methods Two hundred ten patients in suffering from traffic injuries were surveyed from September 1st, 2019 to January 31th, 2020 at 2 University Hospitals (Pusan National Korean Medicine Hospital and Kyung Hee Korean Medicine Hospital at Gangdong) and 1 Spine Specialty Hospital (Jaseng Hospital of Korean Medicine). A structured questionnaire of experience on health care utilization of KM practice and perception of health care system of was distributed to responders by visits and all data were statistically analysed. Results Survey results showed high satisfaction of patients with the experience of KM treatments in order of daoyin exercise (7.8±2.3), chuna manual therapy (7.7±4.0), pharmacoacupuncture (7.4±3.0) etc. Safety concerns were reported in 9.1% subjects and 205 (97.6%) patients answered that collaboration with KM and western medicine is necessary for patients with traffic injuries. For the patients' requirement for extending insurance coverage, the most required therapy was chuna manual therapy (57.5%) and pharmacoacupuncture (42.0%). Conclusions This study presented the realistic patient-centered perception of KM practice and health care system in Korea. These results will provide basic data to be reflected in the process of adaptation for the revision of Korean Medicine CPG for traffic injuries.

Deduction of affecting factors for selecting the way of going into the main building of an apartment complex when constructing an underground parking lot. (지하주차장 공사시 주동진입방법 선정 영향요인 도출)

  • Song, Nak-Hyun;Whang, Kyoung-Jin;Lee, Chan-Sik
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.995-998
    • /
    • 2007
  • The number of households old over as much as 20 years is expected to get increased rapidly more than 1,000,000(1 million). As a measure to this fact remodeling is being revitalized over the country. parking lots expansion actually takes up a great deal of weight among the requirement for remodeling. When constructing a parking lot for enlargement, the way of going into the main building determines such construction features as selection of Retaining Wall Method, installation of an elevator, parking measure of capacity, etc. This study derived the affecting factors for selecting the way of going into the main building when constructing an underground parking lot. In a research way, we examined the features on each method of going into the main building in an apartment complex through an in-depth interview with some experts after investigating the method of enlarging an underground parking lot and going into the main building. After that, we derived the affecting factors for selecting the way of going into the main building. The affecting factors include constructability, convenience, economic efficiency as a high level as well as existence and nonexistence of basement and removal, safety of current building, parking measure of capacity, amenity, inhabitant traffic line, construction expenses and construction duration as a low one. This study will be applied as a reference for selecting the way of going into the main building when constructing an underground parking lot especially targetted on an old apartment house.

  • PDF

Dissipation Pattern of Azoxystrobin, Difenoconazole and Iprodione Treated on Field-Grown Green Garlic (노지재배 풋마늘 중 Azoxystrobin, Difenoconazole 및 Iprodione의 잔류특성)

  • Kang, Hye-Rim;Lee, Young-Ju;Lee, Yu-Ri;Han, Guk-Tak;Chang, Hee-Ra;Kim, Kyun
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.4
    • /
    • pp.446-452
    • /
    • 2011
  • BACKGROUND: To investigate the dissipation patterns of 3 pesticides, azoxystrobin, difenoconazole and iprodione, on green garlic after field treatment pesticides were treated as foliar treatment by single application at recommended and double the recommended rates. METHODS AND RESULTS: Residue samples were harvested at 0, 1, 2, 5, 7 and 10 days post-treatment for azoxystrobin and 0, 1, 2, 5, 7, 10, 15 and 21 days post-treatment for difenoconazole and iprodione. After preparation the fortified samples were extracted and analyzed by gas chromotography-electron capture detector (GC-ECD) to determine the residue levels. Recoveries ranged from 87 to 109% for azoxystrobin, difenoconazole and iprodione at two different levels. The limit of Quantification (LOQ) values were 0.002 mg/kg for azoxystrobin and difenoconazole and 0.01 mg/kg for iprodione. CONCLUSION(S): Half-lives of azoxystrobin, difenoconazole and iprodione in green garlic after treatment were 1.2, 3.8 and 3.2 days at recommended and 1.4, 3.3 and 3.2 at double the recommended rate, respectively. Residue level of azoxystrobin, difenoconazole and iprodione in green garlic were below the maximum residue limits (MRLs) at 0 day, 0 day and 5 days, respectively. Therefore, these pesticide were considered that residues was satisfied to the requirement of domestic trade related to the consumer safety.