• Title/Summary/Keyword: safety function

Search Result 2,793, Processing Time 0.032 seconds

Motion Analysis of Light Buoys Combined with 7 Nautical Mile Self-Contained Lantern (7마일 등명기를 결합한 경량화 등부표의 운동 해석)

  • Son, Bo-Hun;Ko, Seok-Won;Yang, Jae-Hyoung;Jeong, Se-Min
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.5
    • /
    • pp.628-636
    • /
    • 2018
  • Because large buoys are mainly made of steel, they are heavy and vulnerable to corrosion by sea water. This makes buoy installation and maintenance difficult. Moreover, vessel collision accidents with buoys and damage to vessels due to the material of buoys (e.g., steel) are reported every year. Recently, light buoys adopting eco-friendly and lightweight materials have come into the spotlight in order to solve the previously-mentioned problems. In Korea, a new lightweight buoy with a 7-Nautical Mile lantern adopting expanded polypropylene (EPP) and aluminum to create a buoyant body and tower structure, respectively, was developed in 2017. When these light buoys are operated in the ocean, the visibility and angle of light from the lantern installed on the light buoys changes, which may cause them to function improperly. Therefore, research on the performance of light buoys is needed since the weight distribution and motion characteristics of these new buoys differ from conventional models. In this study, stability estimation and motion analyses for newly-developed buoys under various environmental conditions considering a mooring line were carried out using ANSYS AQWA. Numerical simulations for the estimation of wind and current loads were performed using commercial CFD software, Siemens STAR-CCM+, to increase the accuracy of motion analysis. By comparing the estimated maximum significant motions of the light buoys, it was found that waves and currents were more influential in the motion of the buoys. And, the estimated motions of the buoys became larger as the sea state became worser, which might be the reason that the peak frequencies of the wave spectra got closer to those of the buoys.

An Exploratory Empirical Study on Shopping Choice in Retail Channels by the Selective Characteristics of Foods (상품 선택 특성에 따른 쇼핑채널 선택에 관한 연구: 식품 MD를 중심으로)

  • Ha, Kwang-Ok;Lee, Jung-Hee
    • The Journal of Small Business Innovation
    • /
    • v.20 no.1
    • /
    • pp.35-46
    • /
    • 2017
  • The purpose of this study is to obtain the implications for establishing a marketing strategy for retailers by analyzing whether the consumer's preference for products (food) is influenced by on-line, off-line, and omni-channel preferences. The research model consisted of the effects of consumers' food selection characteristics on business preference and omni channel preference. The results of analysis based on 477 questionnaires are summarized as follows. First, food purchasing characteristics that utilize the seven characteristics of (1) freshness of food, (2) taste, (3) quality and safety, (4) tasting, (5) food function and information, (6) country of origin, and (7) brand loyalty, has various effects on types of business preference, omni-channel preference. The adopted hypotheses were selected in order of brand loyalty (5 times), freshness (3 times), tasting (3 times), and origin (1 time). The selective attributes on foods are: (1) what kind of brand, (2) how good the freshness is, (3) tasting. (4) The country of origin is to be compressed. Actually consumers seem to utilize only the core selective factors that are appropriate to the characteristics of the distribution channel rather than all of them in the shopping of the food, and there is three characteristics on Convenience Store and only one or two factors in the other types of business. Second, in the analysis of the omni-channel preference analysis, food selection characteristics has been shown to have a limited effect, which is attributed to the fact that the consumer has not yet understood the concept of omni channel. Third, the results of this study suggest that there is a need to reflect the selection characteristics of foods that have diverse influences by business type in the marketing strategies. Because consumers make reasonable consumption to use both on-line and off-line simultaneously, consumers who use Omni Channel focus on quality and safety of food, identify products through tasting, pursue brands that can trust anywhere. Customers who pursue rationality will have a high preference for using Omni Channel. Product choice characteristic has significant effect on omni-channel preference. For a few years, omni-channel strategy of retailers meets with a difficulty. This study make a first attempt to study omni-channel preference changing retailing paradigm.

  • PDF

A Study on the construction of physical security system by using security design (보안디자인을 활용한 시설보안시스템 구축 방안)

  • Choi, Sun-Tae
    • Korean Security Journal
    • /
    • no.27
    • /
    • pp.129-159
    • /
    • 2011
  • Physical security has always been an extremely important facet within the security arena. A comprehensive security plan consists of three components of physical security, personal security and information security. These elements are interrelated and may exist in varying degrees defending on the type of enterprise or facility being protected. The physical security component of a comprehensive security program is usually composed of policies and procedures, personal, barriers, equipment and records. Human beings kept restless struggle to preserve their and tribal lives. However, humans in prehistoric ages did not learn how to build strong house and how to fortify their residence, so they relied on their protection to the nature and use caves as protection and refuge in cold days. Through the history of man, human has been establishing various protection methods to protect himself and his tribe's life and assets. Physical security methods are set in the base of these security methods. Those caves that primitive men resided was rounded with rock wall except entrance, so safety was guaranteed especially by protection for tribes in all directions. The Great Wall of China that is considered as the longest building in the history was built over one hundred years from about B.C. 400 to prevent the invasion of northern tribes, but this wall enhanced its protection function to small invasions only, and Mongolian army captured the most part of China across this wall by about 1200 A.D. European lords in the Middle Ages built a moat by digging around of castle or reinforced around of the castle by making bascule bridge, and provided these protections to the resident and received agricultural products cultivated. Edwin Holmes of USA in 20 centuries started to provide innovative electric alarm service to the development of the security industry in USA. This is the first of today's electrical security system, and with developments, the security system that combined various electrical security system to the relevant facilities takes charging most parts of today's security market. Like above, humankind established various protection methods to keep life in the beginning and its development continues. Today, modern people installed CCTV to the most facilities all over the country to cope with various social pathological phenomenon and to protect life and assets, so daily life of people are protected and observed. Most of these physical security systems are installed to guarantee our safety but we pay all expenses for these also. Therefore, establishing effective physical security system is very important and urgent problem. On this study, it is suggested methods of establishing effective physical security system by using system integration on the principle of security design about effective security system's effective establishing method of physical security system that is increasing rapidly by needs of modern society.

  • PDF

A Study on the Individual Radiation Exposure of Medical Facility Nuclear Workers by Job (의료기관 핵의학 종사자의 직무 별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee;Oh, Shin-Hyun;Park, Min-Soo;Kim, Jung-Yul;Lee, Jin-Kyu;Na, Soo-Kyung;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.9-16
    • /
    • 2010
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: 1 January 2007 to 31 December 2009 to work in medical institutions are classified as radiation workers Nuclear personal radiation dosimeter regularly, continuously administered survey of 40 workers in three years of occupation to target, Imaging Unit beautifully, age, dose sector, job function-related tasks to identify the average annual dose for a deep dose, respectively, were analyzed. The frequency analysis and ANOVA analysis was performed. Results: Imaging Unit beautifully three years the annual dose PET and PET/CT in the work room 11.06~12.62 mSv dose showed the highest, gamma camera injection room 11.72 mSv with a higher average annual dose of occupation by the clinical technicians 8.92 mSv the highest, radiological 7.50 mSv, a nurse 2.61 mSv, the researchers 0.69 mSv, received 0.48 mSv, 0.35 mSv doctors orderly, and detail work employed the average annual dose of the PET and PET/CT work is 12.09 mSv showed the highest radiation dose, gamma camera injection work the 11.72 mSv, gamma camera imaging work 4.92 mSv, treatment and safety management and 2.98 mSv, a nurse working 2.96 mSv, management of 1.72 mSv, work image analysis 0.92 mSv, reading task 0.54 mSv, with receiving 0.51 mSv, 0.29 mSv research work, respectively. Dose sector average annual dose of the study subjects, 15 people (37.5%) than the 1 mSv dose distribution and 5 people (12.5%) and 1.01~5.0 mSv with the dose distribution was less than, 5.01~10.0 mSv in the 14 people (35.0%), 10.01~20.0 mSv in the 6 people (15.0%) of the distribution were analyzed. The average annual dose according to age in occupations that radiological workers 25~34 years old have the highest average of 8.69 mSv dose showed the average annual dose of tenure of 5~9 years in jobs radiation workers in the 9.5 mSv The average was the highest dose. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

A Double-Blind Comparison of Paroxetine and Amitriptyline in the Treatment of Depression Accompanied by Alcoholism : Behavioral Side Effects during the First 2 Weeks of Treatment (주정중독에 동반된 우울증의 치료에서 Paroxetine과 Amitriptyline의 이중맹 비교 : 치료초기 2주 동안의 행동학적 부작용)

  • Yoon, Jin-Sang;Yoon, Bo-Hyun;Choi, Tae-Seok;Kim, Yong-Bum;Lee, Hyung-Yung
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.2
    • /
    • pp.277-287
    • /
    • 1996
  • Objective : It has been proposed that cognition and related aspects of mental functioning are decreased in depression as well as in alcoholism. The objective of the study was to compare behavioral side effects of paroxetine and amitriptyline in depressed patients accompanied by alcoholism. The focused comparisons were drug effects concerning psychomotor performance, cognitive function, sleep and daytime sleepiness during the first 2 weeks of treatment. Methods : After an alcohol detoxification period(3 weeks) and a washout period(1 week), a total of 20 male inpatients with alcohol use disorder (DSM-IV), who also had a major depressive episode(DSM-IV), were treated double-blind with paroxetine 20mg/day(n=10) or amitriptyline 25mg/day(n=10) for 2 weeks. All patients were required to have a scare of at least 18 respectively on bath the Hamilton Rating Scale far Depression(HAM-D) and Beck Depression Inventory(BDI) at pre-drug baseline. Patients randomized to paroxetine received active medication in the morning and placebo in the evening whereas those randomized to amitriptyline received active medication in the evening and placebo in the morning. All patients performed the various tasks in a test battery at baseline and at days 3, 7 and 14. The test battery included : critical flicker fusion threshold for sensory information processing capacity : choice reaction time for gross psychomotor performance : tracking accuracy and latency of response to peripheral stimulus as a measure of line sensorimotor co-ordination and divided attention : digit symbol substitution as a measure of sustained attention and concentration. To rate perceived sleep and daytime sleepiness, 10cm line Visual analogue scales were employed at baseline and at days 3, 7 and 14. The subjective rating scales were adapted far this study from Leeds sleep Evaluation Questionnaire and Epworth Sleepiness Scale. In addition a comprehensive side effect assessment, using the UKU side effect rating scale, was carried out at baseline and at days 7 and 14. The efficacy of treatment was evaluated using HAM-D, BDI and clinical global impression far severity and improvement at days 7 and 14. Results : The pattern of results indicated thai paroxetine improved performance an mast of the lest variables and also improved sleep with no effect on daytime sleepiness aver the study period. In contrast, amitriptyline produced disruption of performance on same tests and improved sleep with increased daytime sleepiness in particular at day 3. On the UKU side effect rating scale, mare side effects were registered an amitriptyline. The therapeutic efficacy was observed in favor of paroxetine early in day 7. Conclusion : These results demonstrated thai paroxetine in much better than amitriptyline for the treatment of depressed patients accompained by alcoholism at least in terms of behavioral safety and tolerability, furthermore the results may assist in explaining the therapeutic outcome of paroxetine. For example, and earlier onset of antidepressant action of paroxetine may be caused by early improved cognitive function or by contributing to good compliance with treatment.

  • PDF

Autologous Bone Marrow Cell Transplantation Combined with Off-pump Coronary Artery Bypass Grafting in Ischemic Myocardium (허혈성 심근에 관상동맥우회술과 병행한 자가 골수줄기세포 이식)

  • 김현옥;곽영란;강석민;장양수;임상현;안지영;이창영;강면식;유경종
    • Journal of Chest Surgery
    • /
    • v.37 no.7
    • /
    • pp.547-552
    • /
    • 2004
  • Recently, autologous bone marrow cell transplantation (CTx) for angiogenesis and myogenesis in ischemic myocardium has been extensively investigated to improve heart functions. This study was designed to evaluate the effects of CTx with off-pump coronary artery bypass grafting (OPCAB) in patients who were not feasible for complete revascularization. Material and Method: Four male patients underwent CTx and OPCAB simultaneously. Bone marrow was aspirated from iliac bone. Mean 1.5 ${\times}$ 10$^{9}$ mononuclear cells including mean 6.7 ${\times}$ 10$^{6}$ CD34 + cells and 3.7 ${\times}$ 10$^{6}$ AC133 + cells were obtained and concentrated with 10 cc. These cells were transplanted into non-graftable ischemic myocardium after OPCAB. The heart function of all patients were evaluated using the MIBI scan, echocardiogram and MRI preoperatively. The effects of CTx was evaluated using MIBI scan and echocardiogram at 1 month postoperatively. Result: An average of 2 grafts were bypassed to left anterior descending artery territory. Other territories were transplanted with isolated mononuclear cell. All patients had uncomplicated postoperative course. After 1 month follow up, there were improvement in symptom, ejection fraction (from 49% to 55%) on echocardiogram and myocardial perfusion on MIBI scan in all patients. Conclusion: These preliminary data showed improvement of heart function and myocardial perfusion and also showed the feasibility and safety of combined therapy with OPCAB and CTx in ischemic myocardium. However, the effectiveness of CTx alone cannot be readily assessed. Further randomized, controlled studies are required to evaluate the effectiveness of CTx alone.

Temperature-dependent Development and Its Model of the Greenbug, Schizaphis graminum (Rondani) (Homoptera: Aphididae) (보리두갈래진딧물 [Schizaphis graminum (Rondani)]의 온도발육과 발육모형)

  • Lee, Jang-Ho;Kim, Tae-Heung;Kim, Ji-Soo;Hwangn, Chang-Yeon;Lee, Sang-Guei
    • Korean journal of applied entomology
    • /
    • v.46 no.2
    • /
    • pp.213-219
    • /
    • 2007
  • The development of Schizaphis graminum (Rondani) was studied at various constant temperatures ranging from 15 to $32.5^{\circ}C$, with $65{\pm}5%$ RH, and a photoperiod of 16L:8D. Mortality of the $1_{st}-2_{nd}\;and\;the\;3_{rd}-4_{th}$ stage nymphs were similar at most temperature ranges while at high temperature of $32.5^{\circ}C$, more $3_{rd}-4_{th}$ stage individuals died. The total developmental time ranged from 13.8 days at $15^{\circ}C$ to 4.9 days at $30.0^{\circ}C$ suggesting that the higher the temperature, the faster the development. However, at higher end temperature of $32.5^{\circ}C$ the development took 6.4 days. The lower developmental threshold temperature and effective accumulative temperatures for the total immature stage were $6.8^{\circ}C$ and 105.9 day-degrees, respectively and the nonlinear shape of temperature related development was well described by the modified Sharpe and DeMichele model. The normalized cumulative frequency distributions of developmental period for each life stage were fitted to the three-parameter Weibull function. The attendance of shortened developmental times was apparent with $1_{st}-2_{nd}\;nymph,\;3_{rd}-4_{th}$ nymph, and total nymph stages in descending order. The coefficient of determination $r^2$ ranged between 0.80 and 0.87.

Persistence of Fungicide Pencycuron in Soils (토양 중 살균제 Pencycuron의 잔류 특성)

  • An, Xue-Hua;An, Wen-Hao;Im, Il-Bin;Lee, Sang-Bok;Kang, Jong-Gook
    • The Korean Journal of Pesticide Science
    • /
    • v.10 no.4
    • /
    • pp.296-305
    • /
    • 2006
  • The adsorption and persistence of pencycuron {1-(4-chlorobenzyl) cyclopentyl-3-phenylurea} in soils were investigated under laboratory and field conditions to in order to assess the safety use and environmental impact. In the adsorption rate experiments, a significant power function of relation was found between the adsorbed amount of pencycuron and the shaking time. Within one hour following the shaking, the adsorption amounts in the SCL and the SiCL were 60 and 65% of the maximum adsorption amounts, respectively. The adsorption reached a quasi-equilibrium 12 hours after shaking. The adsorption isotherms followed the Freundlich equation. The coefficient (1/n) indicating adsorption strength and degree of nonlinearity was 1.45 for SCL and 1.68 to SiCL. The adsorption coefficients ($K_d$) were 2.31 for SCL and 2.92 to SiCL, and the organic carbon partition coefficient, $K_{oc}$, was 292.9 in SCL and 200.5 inSiCL. In the laboratory study, the degradation rate of pencycuron in soils followed a first-order kinetic model. The degradation rate was greatly affected by soil temperature. As soil incubation temperature was increased from 12 to $28^{\circ}C$, the residual half life was decreased from 95 to 20 days. Arrhenius activation energy was 57.8 kJ $mol^{-1}$. Furthermore, the soil moisture content affected the degradation rate. The half life in soil with 30 to 70% of field moisture capacity was ranged from 21 to 38 days. The moisture dependence coefficient, B value in the empirical equation was 0.65. In field experiments, the half-life were 26 and 23 days, respectively. The duration for period of 90% degradation was 57 days. The difference between SCL and SiCL soils varied to pencycuron degradation rates were very limited, particularly under the field conditions, even though the characteristics of both soils are varied.

Respiratory Gas Exchange and Ventilatory Functions at Maximal Exercise (최대운동시의 호흡성 가스교환 및 환기기능)

  • Cho, Yong-Keun;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.900-912
    • /
    • 1995
  • Background: Although graded exercise stress tests are widely used for the evaluation of cardiorespiratory performance, normal standards on respiratory gas exchange and ventilatory functions at maximal exercise in Koreans have not been well established. The purpose of this study is to provide reference values on these by sex and age, along with derivation of some of their prediction equations. Method: Symptom-limited maximal exercise test was carried out by Bruce protocol in 1,000 healthy adults consisting of 603 males and 397 females, aged 20~66 years. Among them VC, $FEV_1$ and MVV were also determined in 885 cases. All the subjects were members of a health center, excluding athletes. During the exercise, subjects were allowed to hold on to front hand rail of the treadmill for safety purpose. Results: The $VO_2\;max/m^2$, $VCO_2\;max/m^2$ and $V_E\;max/m^2$ were greater in males than in females and decreased with age. The RR max in men and women was similar but decreased slightly with age. The $V_T$ max was markedly greater in men but showed no significant changes with age in either gender. The mean of $V_T$ max/VC, $V_E$ max/MVV and BR revealed that there were considerable ventilatory reserves at maximal exercise even in older females. The regression equations of the cardinal parameters obtained using exercise time(ET, min), age(A, yr), height(Ht, cm), weight(W, kg), sex(S, 0=male; 1=female), VC(L), $FEV_1$(L) and $V_E$ max(L) as variables are as follows: $VO_2\;max/m^2$(L/min)=1.449+0.073 ET-0.007A+0.010W-0.006Ht-0.209S, $VCO_2\;max/m^2$(L/min)=1.672+0.063ET-0.008A+0.010W-0.005Ht-0.319S, VE max/$m^2$(L/min)=58.161+1.503ET-0.315A-9.871S or VE max/$m^2$(L/min)=47.873+6.548 $FEV_1$-5.715 S, and VT max(L)=1.497+0.223VC-0.493S. Conclusion: Respiratory gas exchange and ventilatory variables at maximal exercise were studied in 1,000 non-athletes by Bruce protocol. During exercise, the subjects were allowed to hold on to hand rail of the treadmill for safety purpose. We feel that our results would provide ideal target values for patients and healthy individuals to be achieved, since our study subjects were members of a health center whose physical fitness levels were presumably higher than ordinary population.

  • PDF

Effect of Mulberry Leaf Extract Supplement on Blood Glucose, Glycated Hemoglobin and Serum Lipids in Type II Diabetic Patients (상엽추출물이 제2형 당뇨병 환자의 혈당, 당화혈색소 및 혈청지질에 미치는 영향)

  • Yang, Jung-Hwa;Han, Ji-Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.5
    • /
    • pp.549-556
    • /
    • 2006
  • The purpose of this study was to assess the effects of mulberry leaf extract supplement on blood glucose, glycated hemoglobin ($HbA_{1C}$) and serum lipids in type II diabetic patients, and also to assess safety in liver function after mulberry leaf extract supplement. The study was a randomized placebo-controlled trial and total 23 type II diabetic patients were divided into a MLE group taking 1,000 mg mulberry leaf extract supplement per day as experimental group and a placebo group taking 1,000 mg cellulose Powder supplement per day for 12 weeks. After 2 weeks of wash-out period, fasting blood glucose, $HbA_{1C}$, serum lipid levels and liver function test were analyzed before and after treatment of 12 weeks. The general baseline characteristics, nutrient intake and life style factors of study subjects were similar between two groups during intervention. The concentrations of fasting blood glucose and $HbA_{1C}$ (p<0.05) decreased significantly after mulberry leaf extract supplement in MLE group, while there were no changes found in placebo group. We also found it showed that mulberry leaf extract supplement for 12 weeks decreased significantly (p<0.05) the fasting blood glucose in poor fasting blood glucose group and $HbA_{1C}$ concentration in poor $HbA_{1C}$ group. The concentrations of LDL-cholesterol (p<0.05) and triglyceride (p<0.01) decreased significantly in MLE group after 12 weeks of taking the supplement, while there were no changes found in placebo group. The mulberry leaf extract supplement for 12 weeks didn't show hepatotoxicity. These results suggested that mulberry leaf extract supplement could be effective in improving fasting blood glucose and $HbA_{1C}$ levels in the diabetic patients, specially having high concentrations of fasting blood glucose and $HbA_{1C}$ among type II diabetic patients.