• Title/Summary/Keyword: safety diagnosis

Search Result 982, Processing Time 0.023 seconds

The Clinical Usefulness of Transbronchial Lung Biopsy in Critically III Patients with Pulmonary Infiltrates of Uncertain Etiology (폐 침윤과 호흡부전을 동반한 중환자에서 경기관지폐생검의 임상적 유용성에 관한 연구)

  • Jang, Eun-Ha;Koh, Youn-Suck;Shim, Tae-Sun;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Go, Yun-Seok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.2
    • /
    • pp.236-245
    • /
    • 2000
  • Background: Transbronchial lung biopsy(TBLB) has known to yield useful information for pulmonary infiltrates of uncertain etiology, However, its safety and usefulness have not been conclusive in the critically ill patients with respiratory failure. Moreover, TBLB has not been recommended for patients with mechanical ventilation. This study was conducted to investigate the diagnostic values and risks of Will performed on critically ill patients at bedside to obtain information on the pulmonary infiltrate of unknown etiology. Methods: Twenty patients(21 admissions with 23 cases) with diffuse pulmonary infiltrates who were treated in a medical intensive care unit of a tertiary referral hospital from January 1994 to May 1998, were enrolled for the study. Their medical records were retrospectively reviewed. TBLB was opted when a noninvasive diagnostic work-up failed to reveal the cause for the pulmonary infiltrate. The procedure was performed at patients' bedside without assistance of fluoroscopy. Bronchial washing or bronchoalveolar lavage was performed on the same pulmonary segment before performing TBLB. Results: Adequate specimens were obtained in 18 cases(78%). TBLB provided a specific diagnosis in two cases. The results of TBLB suggested the underlying etiology in 9 cases; bacterial pneumonitis(4), hypersensitivity pneumonitis(1), polymyositis(1), radiation fibrosis(1), idiopathic pulmonary fibrosis(1), and BOOP(1). Therapeutic decisions were altered in 11 cases(47.8%) based on the TBLB results. Pneumocystis carinii was found in the BAL fluid of another case. Ten patients with a therapeutic change and ten patients without a management change had mortality rates of 40% and 80%, respectively. The APACHE III scores were significantly higher in patients with complications($72.8{\pm}21.8$) compared with those without complications ($48.3{\pm}18.9$)(p<0.05). The complication rates were higher in those with mechanical ventilation(50%) than in those without Mechanical ventilation(33%), but the difference was not statistically significant(p=0.3). Conclusions: TBLB may be a useful diagnostic option for critically ill patients with unknown cause of pulmonary infiltrates. However, it should be cautious be used with care for patients with mechanical ventilation or for severely ill patients.

  • PDF

Is Video-assisted Thoracoscopic Resection for Treating Apical Neurogenic Tumors Always Safe? (흉강 첨부 양성 신경종의 흉강경을 이용한 절제술: 언제나 안전하게 시행할 수 있나?)

  • Cho, Deog Gon;Jo, Min Seop;Kang, Chul Ung;Cho, Kyu Do;Choi, Si Young;Park, Jae Kil;Jo, Keon Hyeon
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.72-78
    • /
    • 2009
  • Background: Mediastinal neurogenic tumors are generally benign lesions and they are ideal candidates for performing resection via video-assisted thoracoscopic surgery (VATS). However, benign neurogenic tumors at the thoracic apex present technical problems for the surgeon because of the limited exposure of the neurovascular structures, and the optimal way to surgically access these tumors is still a matter of debate. This study aims to clarify the feasibility and safety of the VATS approach for performing surgical resection of benign apical neurogenic tumors (ANT). Material and Method: From January 1996 to September 2008, 31 patients with benign ANT (15 males/16 females, mean age: 45 years, range: 8~73), were operated on by various surgical methods: 14 VATS, 10 lateral thoracotomies, 6 cervical or cervicothoracic incisions and 1 median sternotomy. 3 patients had associated von Recklinhausen's disease. The perioperative variables and complications were retrospectively reviewed according to the surgical approaches, and the surgical results of VATS were compared with those of the other invasive surgeries. Result: In the VATS group, the histologic diagnosis was schwannoma in 9 cases, neurofibroma in 4 cases and ganglioneuroma in 1 case, and the median tumor size was 4.3 cm (range: 1.2~7.0 cm). The operation time, amount of chest tube drainage and the postoperative stay in the VATS group were significantly less than that in the other invasive surgical group (p<0.05). No conversion thoracotomy was required. There were 2 cases of Hornor's syndrome and 2 brachial plexus neuropathies in the VATS group; there was 1 case of Honor's syndrome, 1 brachial plexus neuropathy, 1 vocal cord palsy and 2 non-neurologic complications in the invasive surgical group, and all the complications developed postoperatively. The operative method was an independent predictor for postoperative neuropathies in the VATS group (that is, non-enucleation of the tumor) (p=0.029). Conclusion: The VATS approach for treating benign ANT is a less invasive, safe and feasible method. Enucleation of the tumor during the VATS procedure may be an important technique to decrease the postoperative neurological complications.

Laparoscopy Assisted Total Gastrectomy with Lymph Node Dissection-77 Consecutive Cases (복강경 보조 위 전절제술-연속된 77예의 경험)

  • Lee, Joong-Ho;Song, Jye-Won;Oh, Sung-Jin;Kim, Sung-Soo;Choi, Won-Hyuk;Cheong, Jae-Ho;Hyung, Woo-Jin;Choi, Seung-Ho;Noh, Sung-Hoon
    • Journal of Gastric Cancer
    • /
    • v.7 no.4
    • /
    • pp.206-212
    • /
    • 2007
  • Purpose: The number of laparoscopy assisted distal gastrectomies (LADG) is gradually increasing for the treatment of early gastric cancer (EGC) patients as a surgical modality for improving quality of life. However, there are few reports on laparoscopy-assisted total gastrectomy (LATG), mainly because this procedure is performed relatively infrequently, and the procedure is more complicated than LADG. This study was performed to evaluate the technical feasibility, safety, and surgical results of LATG with lymphadenectomy through a review of our experience. Materials and Methods: From July 2003 to June 2007, 77 LATG with Roux-en-Y esophagojejunostomy were performed for patients with a preoperative diagnosis of EGC. The clinicopathological features and surgical outcomes were analyzed. Results: There were 49 males and 28 females in the study with a mean age of 61 years (range $30{\sim}85$ years). The mean operation time was 210 minutes (range $100{\sim}400$ minutes) and the operation time was gradually decreased as the case numbers increased. There were 13 operative morbidities (16.9%) and no operative mortalities. The restoration of bowel motility was noted at 3.2 postoperative days; a soft diet was started at 4.4 postoperative days and the duration of hospital stay was 10 days. There were 20 mucosal lesions, 32 submucosal lesions, 15 proper muscle lesions, 7 subserosal lesions and 3 serosal lesions. A total of 20 patients were treated by D2 lymph node dissection, 55 patients were treated by D1+$\beta$ lymph node dissection, and two patients were treated by D1+$\alpha$ lymph node dissection. The mean number of retrieved lymph nodes was 42 (range $11{\sim}86$). Lymph node metastases were noted in 12 patients. Conclusion: This study indicated LATG could be applied safely and effectively for patients with EGC. However, a prospective study comparing laparoscopy-assisted versus open gastrectomy for short-term and long-term surgical outcome is needed.

  • PDF

Repair of Acute Aortic Arch Dissection with Hypothermic Circulatory Arrest and Retrograde Cerebral Perfusion (저체온순환정지와 역행성 뇌관류에 의한 대동맥궁을 침범한 급성 대동맥 박리증의 수술결과)

  • 이삼윤
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.43-49
    • /
    • 2004
  • Background: Acute thoracic aortic dissections involving the aortic arch differ in diagnosis, surgical procedures, and operative results compared to those that do not involve the aortic arch. In general cerebral perfusion under deep hypothermic circulatory arrest (HCA) is performed during the repair of the aortic arch dissection. Here, we report our surgical results of the aortic arch dissection repair using retrograde cerebral perfusion (RCP) and its safety. Material and Method: Between January 1996 and June 2002, 22 consecutive patients with aortic arch dissection underwent aortic arch repair. In 20 of them RCP was performed under HCA. RCP was done through superior vena cava in 19 patients and by systemic retrograde venous perfusion in 1, in whom it was difficult to reach the SVC. When the patient's rectal temperature reached 16 to 18$^{\circ}C$, systemic circulation was arrested, and the amount of RCP amount was 481.1 $\pm$292.9 $m\ell$/min with perfusion pressure of 20∼30 mmHg. Result: There were two in-hospital deaths (4.5%) and one late death (9.1%). Mean circulatory arrest time (RCP time) was 54.0$\pm$ 13.4 minutes (range, 7 to 145 minutes). RCP time has no correlation with the appearance of consciousness, recovery of orientation, or ventilator weaning time (p=0.35, 0.86, and 0.92, respectively). Ventilator weaning was faster in patients with earlier recovery of consciousness and orientation (r=0.850, r=926; p=0.000, respectively). RCP of more than 70 minutes did not affect the appearance of consciousness, recovery of orientation, ventilator weaning time, exercise time, or hospital stay (p=0.42, 0.57, 0.60, 0.83, and 0.51, respectively). Conclusion: Retrograde cerebral perfusion time under hypothermic circulatory arrest during repair of aortic arch dissection may not affect recovery of orientation, ventilator weaning time, neurologic complications, and postoperative recovery.

Performance Measurement of Diagnostic X Ray System (진단용 X선 발생장치의 성능 측정)

  • You, Ingyu;Lim, Cheonghwan;Lee, Sangho;Lee, Mankoo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.447-454
    • /
    • 2012
  • To examine the performance of a diagnostic X-ray system, we tested a linearity, reproducibility, and Half Value Layer(HVL). The linearity was examined 4 times of irradiation with a given condition, and we recorded a level of radiation. We then calculated the mR/mAs. And the measured value should not be more than 0.1. If the measured value was more than 0.1, we could know that the linearity was decreased. The reproducibility was analyzed 10 times of irradiations at 80kVp, 200mA, 20mAs and 120kVp, 300mA, 8mAs. The values from these analyses were integrated into CV equation, and we could get outputs. The reproducibility was good if the output was lower than 0.05. HVL was measured 3 times of irradiation without a filter, and we inserted additional HLV filters with 0, 1, 2, 4 mm of thickness. We tested the values until we get the measured value less than a half of the value measured without additional filter. We tested the linearity, the reproducibility, and HVL of 5 diagnostic X-ray generators in this facilities. The linearity of No. 1 and No. 5 generator didn't satisfy the standard for radiation safety around 300mA~400mA and 100mA~200mA, respectively. HVL of No.1 generator was not satisfied at 80kVp. The outputs were higher in the three-phase equipment than the single-phase equipment. The old generators need to maintain and exchange of components based on the these results. Then, we could contribute to getting more exact diagnosis increasing a quality of the image and decreasing an expose dose of radiation.

The Evaluation and Development of Head and Neck Radiation Protective Device for Chest Radiography in 10 Years Children (소아(10세) 흉부 방사선촬영에서의 두경부 방사선 방어기구 개발 및 평가)

  • Lee, Jun Ho;Lim, Hyun Soo;Lee, Seung Yeol
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.118-123
    • /
    • 2015
  • The frequency of diagnostic radiation examinations in medical institutions has recently increased to 220 million cases in 2011, and the annual exposure dose per capita was 1.4 mSv, 51% and 35% respectively, compared to those in 2007. The number of chest radiography was found to be 27.59% of them, the highest frequency of normal radiography. In this study, we developed a shielding device to minimize radiation exposure by shielding areas of the body which are unnecessary for image interpretation, during the chest radiography. And in order to verify its usefulness, we also measured the difference in entrance surface dose (ESD) and the absorbed dose, before and after using the device, by using an international standard pediatric (10 years) phantom and a glass dosimeter. In addition, we calculated the effective dose by using a Monte Carlo simulation-based program (PCXMC 2.0.1) and evaluated the reduction ratio indirectly by comparing lifetime attributable risk of cancer incidence (LAR). When using the protective device, the ESD decreased by 86.36% on average, nasal cavity $0.55{\mu}Sv$ (74.06%), thyroid $1.43{\mu}Sv$ (95.15%), oesophagus $6.35{\mu}Sv$ (78.42%) respectively, and the depth dose decreased by 72.30% on average, the cervical spine(upper spine) $1.23{\mu}Sv$ (89.73%), salivary gland $0.5{\mu}Sv$ (92.31%), oesophagus $3.85{\mu}Sv$ (59.39%), thyroid $2.02{\mu}Sv$ (73.53%), thoracic vertebrae(middle spine) $5.68{\mu}Sv$ (54.01%) respectively, so that we could verify the usefulness of the shielding mechanism. In addition, the effective dose decreased by 11.76% from $8.33{\mu}Sv$ to $7.35{\mu}Sv$ before and after wearing the device, and in LAR assessment, we found that thyroid cancer decreased to male 0.14 people (95.12%) and female 0.77 people (95.16%) per one million 10-year old children, and general cancers decreased to male 0.14 people (11.70%) and female 0.25 people (11.70%). Although diagnostic radiation examinations are necessary for healthcare such as the treatment of diseases, based on the ALARA concept, we should strive to optimize medical radiation by using this shielding device actively in the areas of the body unnecessary for the diagnosis.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.

Analyze Technologies and Trends in Commercialized Radiology Artificial Intelligence Medical Device (상용화된 영상의학 인공지능 의료기기의 기술 및 동향 분석)

  • Chang-Hwa Han
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.881-887
    • /
    • 2023
  • This study aims to analyze the development and current trends of AI-based medical imaging devices commercialized in South Korea. As of September 30, 2023, there were a total of 186 AI-based medical devices licensed, certified, and reported to the Korean Ministry of Food and Drug Safety, of which 138 were related to imaging. The study comprehensively examined the yearly approval trends, equipment types, application areas, and key functions from 2018 to 2023. The study found that the number of AI medical devices started from four products in 2018 and grew steadily until 2023, with a sharp increase after 2020. This can be attributed to the interaction between the advancement of AI technology and the increasing demand in the medical field. By equipment, AI medical devices were developed in the order of CT, X-ray, and MR, which reflects the characteristics and clinical importance of the images of each equipment. This study found that the development of AI medical devices for specific areas such as the thorax, cranial nerves, and musculoskeletal system is active, and the main functions are medical image analysis, detection and diagnosis assistance, and image transmission. These results suggest that AI's pattern recognition and data analysis capabilities are playing an important role in the medical imaging field. In addition, this study examined the number of Korean products that have received international certifications, particularly the US FDA and European CE. The results show that many products have been certified by both organizations, indicating that Korean AI medical devices are in line with international standards and are competitive in the global market. By analyzing the impact of AI technology on medical imaging and its potential for development, this study provides important implications for future research and development directions. However, challenges such as regulatory aspects, data quality and accessibility, and clinical validity are also pointed out, requiring continued research and improvement on these issues.

Physiological and Psychological analysis of musculoskeletal symptoms (근골격계질환에 대한 물리적/심리적요인에 대한 연구)

  • Donghyun Park;Sung Kyu Bae
    • Korean Journal of Culture and Social Issue
    • /
    • v.9 no.spc
    • /
    • pp.107-122
    • /
    • 2003
  • The object of this study is to evaluate the prevailing physical and psychosocial conditions regarding occupational low back injury. This study consists of two parts. In the first part of the study, analytic biomechanical model and NIOSH guidelines are applied to evaluate risk levels of low back injury for automobile assembly jobs. Total of 246 workers are analysed. There are 20 jobs having greater back compressive forces than 300kg at L5/S1. Also, there are 44 jobs over Action Limit with respect to 1981 NIOSH guidelines. The relationship between psychosocial factors and low back injury was examined in the second part of the study. A battery of questionnaires concerning the psychosocial stress based on PWI (Psychosocial Well-being Index) and musculoskeletal pain symptoms at low back was completed by 246 workers at the same plant. Results showed that 207 out 246 workers experienced the symptoms and 27 workers were diagnosed as patients. Two groups(low stressed, high stressed) based on PWI score had no significant relationships with both symptoms and results of diagnosis. The relationships between physical work load and psychosocial stress were also analysed. Specifically, some postural factors(vertical deviation angle of forearm, horizontal deviation angle of upperarm, vertical deviation angle of thigh, etc) were highly correlated with psychosocial stress. The results illustrated that PWI scores were associated with some physical workloads. However, psychosocial stress levels couldn't be well related with the pain symptom as well as the actual incidence of low back injury since pain or discomfort regarding low back injury were more complex than that of other musculoskeletal disorders.

  • PDF