• Title/Summary/Keyword: safety diagnosis

Search Result 980, Processing Time 0.026 seconds

Understanding Facility Management on Tunnel through Text Mining of Precision Safety Diagnosis Data (터널시설물 점검진단 데이터의 텍스트마이닝 분석을 통한 유형별·지역별 중점 유지관리요소의 이해)

  • Seo, Jeong-eun;Oh, Jintak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.21 no.3
    • /
    • pp.85-92
    • /
    • 2021
  • The purpose of this paper is to understand the key factors for efficient maintenance of rapidly aging facilities. Therefore, the safety inspection/diagnosis reports accumulated in the unstructured data were collected and preprocessed. Then, the analysis was performed using a text mining analysis method. The derived vulnerabilities of tunnel facilities can be used as elements of inspections that take into account the characteristics of individual facilities during regular inspections and daily inspections in the short term. In addition, if detailed specification information and other inspection results(safety, durability, and ease of use) are used for analysis, it provides a stepping stone for supporting preemptive maintenance decision-making in the long term.

Review of Non-Contact Concrete Damage Depth Estimation Technique Based on High-Power Pulsed Laser (고출력펄스 레이저 기반 비접촉 콘크리트 열화깊이 추정 기법 검토)

  • Choe, Gyeong-Cheol;Kim, Hong-Seop;Jeon, Jun-Seo;Kim, Eun-Young;Lee, Mun-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.267-268
    • /
    • 2023
  • Out of an estimated 7 million buildings nationwide, approximately 38% of them have been standing for over 30 years, and this number is expected to continue to increase. Additionally, due to the Building Act, safety inspections will be mandatory for approximately 70,000 buildings annually, leading to an increase in demand for building safety inspections. However, the current building safety diagnosis heavily relies on manpower, making it difficult to diagnose locations that are hard to access, and requiring lengthy investigation periods. Therefore, this paper presents the basic research results of a non-contact concrete damage depth estimation technique using laser technology aimed at remote building safety diagnosis and shortening investigation periods.

  • PDF

Evaluation of Popping Performance of Safety Valves in City Gas Facilities (도시가스시설에서 안전밸브의 분출성능에 관한 평가 연구)

  • 김영규;김청균
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.2
    • /
    • pp.104-108
    • /
    • 1998
  • In order to evaluate the performances of safety valves for low pressure, the popping pressure and flow rate of the natural gas have been investigated. The measured results of the popping pressure show that there is a big scattering depending on the manufacture year of a safety valve. And sample A showed the ideal popping pressure mode compared to other B and C samples. The popping flow rate of the safety valve is proportional to the seat size as the inlet pressure increases. These results may be used as a guideline for a design and diagnosis of the safety valve.

  • PDF

The Development of Infrared Thermal Imaging Safety Diagnosis System Using Pearson's Correlation Coefficient (피어슨 상관계수를 이용한 적외선 열화상 안전 진단 시스템 개발)

  • Jung, Jong-Moon;Park, Sung-Hun;Lee, Yong-Sik;Gim, Jae-Hyeon
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.55-65
    • /
    • 2019
  • With the rapid development of the national industry, the importance of electrical safety was recognized because of a lot of new electrical equipment are installing and the electrical accidents have been occurring annually. Today, the electrical equipments is inspect by using the portable Infrared thermal imaging camera. but the most negative element of using the camera is inspected for only state of heating, the reliable diagnosis is depended with inspector's knowledge, and real-time monitoring is impossible. This paper present the infrared thermal imaging safety diagnosis system. This system is able to monitor in real time, predict the state of fault, and diagnose the state with analysis of thermal and power data. The system consists of a main processor, an infrared camera module, the power data acquisition board, and a server. The diagnostic algorithm is based on a mathematical model designed by analyzing the Pearson's Correlation Coefficient between temperature and power data. To test the prediction algorithm, the simulations were performed by damaging the terminals or cables on the switchboard to generate a large amount of heat. Utilizing these simulations, the developed prediction algorithm was verified.

Availability evaluation of automatic inspection equipment using line scan camera for concrete lining (라인스캔 카메라를 이용한 콘크리트 라이닝 자동점검진단 장비 활용성 평가)

  • Lee, Gyu-Phil;Lim, Hyung-Joon;Kim, Jeong-Heum
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.6
    • /
    • pp.643-653
    • /
    • 2020
  • The concrete lining inspection by inspector after traffic control poses various problems such as congestion caused by traffic control and social loss costs resulting from it, and risks of traffic accidents and safety accidents for inspectors et al. To solve the problems, the concrete lining inspection has been carried out using automatic inspection equipment and image analysis that can be objectively and quantitatively investigated in overseas. In this study, to solve the problems of concrete lining inspection by inspector and to review improvement plan for inspection, inspection was carried out using automatic inspection equipment for ◯◯ tunnel that precision safety diagnosis has been conducted in 2019. Analysis was carried out for both inspection results. Automatic inspection equipment investigated defects in concrete lining such as cracks more accurately than precision safety diagnosis.

A Study on The Safety Management of City Gas Pipelines Attached on the Bridges (교량에 설치된 도시가스배관의 안전관리에 관한 연구)

  • Yun, Young-Man;Son, Sang-Geun;Choi, Do-Kyun;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.45-52
    • /
    • 2018
  • In this study, 398 city gas pipe systems installed on the bridges were surveyed and analyzed classified characteristics about the ages, length, and remote isolation devices installed or not. As a result of analysis, 43.0% pipes have been used more than 20 years and 89.4% do not have remote cut-off devices, so this study suggest safety management ways for the issues. Chosen 76 pipes were researched stress strain characteristics by CAESAR-II which is a specialized program for stress analysis. And, when a loop is installed on the bridge pipe, effect on code stress by the location and size of the loop was performed. This study can help to improve safety level by revising criteria of new installation, inspection and diagnostic.

A Study on the Safety Improvement of City Gas Pressure Regulators in Apartment Housing (공동주택 등에 설치하는 도시가스 압력조정기의 안전성 향상에 관한 연구)

  • Youngman Yun;Yongchai Kwon;Kyungho Kim;Jihyun Jang
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.86-94
    • /
    • 2023
  • This study was conducted with the purpose of preparing an alternative to improving the safety of civil pressure regulators installed instead of gas governors to supply city gas to apartment houses. First, problems were derived and solutions were presented by investigating the safety standards and installation status of domestic pressure regulators. In addition, using the DNV Phast-Safeti program, a quantitative risk assessment solution, risks such as gas leakage contained in pressure regulators installed in apartment houses and surrounding gas facilities were evaluated in terms of individual risks and societal risks, and measures were derived to reduce the risks in the installation and management of the pressure regulators.