• Title/Summary/Keyword: safe use

Search Result 2,035, Processing Time 0.027 seconds

A Study on a Secure Internet Service Provider Model Using Smart Secure-Pad (스마트 보안패드를 이용한 안전한 인터넷 서비스 제공 모델에 관한 연구)

  • Lee, Jae-Sik;Kim, Hyung-Joo;Jun, Moon-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1428-1438
    • /
    • 2013
  • Services take place in Internet environment, a formation of the trust relationship between user and service provider for services. Different authentication schemes such as using Certificate of Public Key Infrastructure authentication and using ID/PW for a simple user authentication have been proposed for trust relationship. In addition, in the case of electronic financial transactions, transaction integrity and non-repudiation features are provided. These services are provided in Internet environment, use various measures to ensure service safety. However, it was difficult to prevent attacks using existing security technology because of emergence of MITB attack that manipulate the memory area of the Web browser and social engineering attacks such as phishing/pharming, requires application of new security technologies became. In this paper, we propose a concept of smart secure-pad, and utilize it safely formed a trust relationship between user and service provider, a model has been proposed to ensure safety of data transmission. Proposed model's security evaluation results show security against to MITB attack and phishing/pharming that can't be prevent attack using existing security technology. In addition, service provider can easily apply the model in safe environment can provide Internet service using provided representative services applying the proposed model.

Surgical Treatment with Extracorporeal Circulation for Acute Dissection of Descending Thoracic Aorta (체외순환을 이용한 흉부 하행대동맥의 급성 박리증 수술)

  • 최종범;정해동;양현웅;이삼윤;최순호
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.481-487
    • /
    • 1998
  • The surgical management of acute type B dissection is controversial. The complexity of the repair usually requires a period of aortic cross-clamping exceeding 30 minutes, which can cause ischemic injury of the spinal cord. Several forms of distal perfusion have been considered for use to prevent this injury. To determine the safety and efficacy of a graft replacement with cardiopulmonary bypass in reparing acute dissection of descending thoracic aorta, we retrospectively reviewed our surgical experience treating 8 patients who had aortic dissection secondary to atherosclerosis, trauma, and carcinoma invasion. Cardiopulmonary bypass was performed with two aortic cannulas for simultaneous perfusion of the upper and lower body and one venous cannula for draining venous blood from the right atrium or inferior vena cava. Although aortic cross-clamp time was relatively long (average, 117.8 minutes; range, 47 to 180 minutes) in all cases, there was no neurologic deficit immediately after graft replacement for the aortic lesion. Two patients(25%) of relatively old age died on the postoperative 31st and 41st days, respectively, because of delayed postoperative complications, such as pulmonary abscess and adult respiratory distress syndrome. Although any of several maneuvers may be appropriate in managing dissection of the descending aorta, graft replacement with cardiopulmonary bypass during aortic cross-clamping may be a safe and effective method for the treatment of acute dissection of the descending thoracic aorta.

  • PDF

Pulmonary Resection for Invasive Pulmonary Aspergillosis in Hematological Malignancy Patients (혈액암 환자에서 합병된 침습성 폐아스페르길루스증의 수술적 치료)

  • Sa, Young-Jo;Kim, Yong-Han;Nam, Sang-Yong;Sim, Sung-Bo;Lee, Sun-Hee;Park, Jae-Kil
    • Journal of Chest Surgery
    • /
    • v.40 no.9
    • /
    • pp.617-623
    • /
    • 2007
  • Background: Invasive pulmonary aspergillosis, a frequent fungal infection in immunocompromised patients, is known to have a poor prognosis despite the use of antifungal therapy in leukemic patients. We studied the outcome of surgical resection of invasive pulmonary aspergillosis where bleeding tendency, localized recurrence of infection, and incidence could be reduced. Material and Method: We retrospectively reviewed 14 patients with a hematological malignancy where invasive pulmonary aspergillosis was diagnosed during the 10 years between 1998 and 2007. From the medical records, we reviewed the type and treatment of the hematological malignancy, including the diagnostic methods of invasive pulmonary aspergillosis, the preoperative hematological conditions and their management, and the surgical methods and records. We also analyzed the development of postoperative complications and patient mortality, the recurrence of postoperative invasive pulmonary aspergillosis, and if the patients had a bone marrow transplant. Result: Fourteen patients with invasive pulmonary aspergillosis and a hematological malignancy underwent a pulmonary lobectomy. One patient had a complication of bronchopleural fistula, but there were no other serious complications such as bleeding or wound infection, and none of the patients died postoperatively. Conclusion: We have shown that pulmonary lobectomy is a safe and effective therapy for invasive pulmonary aspergillosis in patients with hematological malignancies that allow further treatment of the hematological malignancy.

Early and Midterm Outcome of Redo Coronary Artery Bypass Grafting: On-Pump versus Off-Pump Bypass

  • Shin, Yu Rim;Lee, Sak;Joo, Hyun Chel;Youn, Young-Nam;Kim, Jong Gun;Yoo, Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.47 no.3
    • /
    • pp.225-232
    • /
    • 2014
  • Background: Redo coronary artery bypass grafting (CABG) is still associated with increased morbidity and mortality as compared to the first-time operation. Further, the application of the off-pump technique to redo CABG is limited due to technical difficulties. The aim of this retrospective study was to analyze early and midterm results after redo CABG and compare the outcome of redo on-pump and off-pump CABG. Methods: From June 1996 to October 2011, elective redo CABG was performed in 32 patients. Mean age was 64.8 years (on pump 64.3 years vs. off pump 65.5 years; p=0.658), and 21 patients were male. Among these patients, 14 (43.8%) underwent on-pump CABG, and 18 (56.2%) underwent off-pump CABG. Results: Internal thoracic artery was used in 22 patients (68.8%), and total arterial revascularization was achieved in 17 patients (53.1%). The average number of distal anastomoses was 2.13, and the rate of incomplete revascularization was 43.8%. The rate of total arterial revascularization was higher in the off-pump group (14.3% vs. 83.3%, p<0.001), and the use of saphenous vein graft was more in the on-pump group (78.6% vs. 16.7%, p<0.001). Overall hospital mortality was 3.1% (n=1) and was comparable in both groups (on pump 7.1% vs. off pump 0%; p=0.249). Postoperative complications occurred in 9 patients (64.2%), and the rate of complications was high in the on-pump group without statistical significance (64.2% vs. 33.3%, p=0.082). The mean follow-up duration was 5.4 years, and overall survival at 10 years was $86.0%{\pm}10.5%$. There was no significant difference in the 10-year survival rate between the two groups (79.6% vs. 100%, p=0.225). Conclusion: Redo CABG can be safely performed with acceptable mortality. Redo off-pump coronary artery bypass is feasible with low mortality and morbidity, comparable target vessel bypass grafting, and long-term survival. The off-pump technique might be considered a safe option for redo CABG in high-risk patients.

Development and Application of Traffic Accident Forecasting Model for Signalized Intersections (Four-Legged Signalized Intersections In Kwang-Ju) (신호교차로 교통사고 예측모형의 개발 및 적용 (광주광역시 4-지 신호교차로를 중심으로))

  • 하태준;강정규;박제진
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.6
    • /
    • pp.207-218
    • /
    • 2001
  • As a city and industries are developed rapidly, a traffic accident and congestion take places on the road link become serious and it can be a large problem of the society in the future. Especially, most of the traffic accidents on the signalized intersection are caused by the human factor, vehicle and environmental factor mutually. The relation of the traffic accident and volume is acting on the outbreak of the traffic accident and the mistake of driver altogether as a major cause. The purpose of this paper is to develop a model for the forecasting of the traffic accident and to use research data gained to predict many traffic accidents. The data of this study were used with real one of the 73 areas of the four-legged signalized intersection in Kwang-ju city from 1996 to 1998 for three years to develop a model for the forecasting of the traffic accident. The statistical methods used in this paper are the principal component, regression and correlation analysis. We studied accident models to find out useful data from the statistics method and applied the data to the different area of the Choun-La province for the verification of the model. So, the result of this paper showed a reasonable model for the forecasting or the traffic accident and possibility of the model for simulating on real case. Finally, This study would be made of a study continually for the safe design and plan for the four-legged signalized intersection.

  • PDF

Bactericidal Efficacy of Non-thermal DBD Plasma on Staphylococcus aureus and Escherichia coli (비열 유전체장벽방전 플라즈마의 포도상구균 및 대장균 살균효과)

  • Kim, Keyyoung;Paik, Namwon;Kim, Yonghee;Yoo, Kwanho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.1
    • /
    • pp.61-79
    • /
    • 2018
  • Objectives: The objective of this study was to examine the effect of non-thermal dielectric barrier discharge(DBD) plasma on decontamination of Staphylococcus aureus(S. aureus) and Escherichia coli(E. coli) as common pathogens. Methods: This experiment was carried out in a chamber($0.64m^3$)designed by the authors. The plasma was continuously generated by a non-thermal DBD plasma generator(Model TB-300, Shinyoung Air tech, Korea). Suspensions of S. aureus and E. coli of 0.5 McFarland standard($1.5{\times}10^8CFU/mL$) were prepared using a Densi-Check photometer(bio $M{\acute{e}}rieux$, France). The suspensions were diluted1:1000 in sterile PBS solutions(approximately$10^{4-5}CFU/mL$) and inoculated on tryptic soy agar(TSA) in Petri dishes. The Petri dishes(80mm internal diameter)were exposed to the non -thermal DBD plasma in the chamber. Results: The results showed that 95% of S. aureus colonies were killed after a six-hour exposure to the DBD plasma. In the case of E. coli, it took two hours to kill 100% of the colonies. The gram-negative E. coli had a greater reduction than the gram-positive S. aureus. This difference may be due to the structure of their cell membranes. The thickness of gram-positive bacteria is greater than that of gram-negative bacteria. The S. aureus is more resistant to DBD plasma exposures than is E. coli. It should be noted that average concentrations of ozone, a byproduct of the DBD plasma generator, were monitored throughout the experiment and the results were well below the criteria, 50 ppb, recommended by the Korean Ministry of the Environment. Thus, non-thermal DBD plasma is deemed safe for use in hospital and public facilities. Conclusions: There was evidence that non-thermal DBD plasma can effectively kill S. aureus and E. coli. The results indicate that DBD plasma technology can greatly contribute to the control of infections in hospitals and other public and private facilities.

Mouse Single Oral Dose Toxicity Test of Lactobacillus-fermented Araliae Continentalis Radix Aqueous Extracts (fACR) (독활의 복합 유산균 발효 추출액의 마우스에 대한 단회경구투여 독성시험)

  • Jung, Young-Mi;Ku, Sae-Kwang;Lee, Dong Sub;Kwon, Kisang
    • Journal of Life Science
    • /
    • v.26 no.2
    • /
    • pp.204-211
    • /
    • 2016
  • The objective of this study was to obtain acute (single) oral dose toxicity information on Lactobacillus-fermented Araliae Continentalis Radix aqueous extracts (fACR) in female and male ICR mice, as compared with Araliae Continentalis Radix aqueous extracts (ACR). After administering a single oral dose of fACR, no treatment-related mortalities were observed within 14 days after the end of treatment up to 2,000 mg/kg, the maximum dosage for rodents of both sexes; moreover, no fACR treatment-related changes in the body and organ weights, clinical signs, necropsy, and histopathological findings were detected in this experiment. In addition, no ACR 2,000 mg/kg treatment-related mortalities, clinical signs, body and organ weights, or gross and histopathological findings were observed, as compared with equal genders of vehicle control. The results obtained in this study suggest that fACR is non-toxic in mice and is, therefore, likely to be safe for clinical use. The LD50 and approximate LD in female mice and male mice, respectively, were considered after a single oral dose of fACR over 2,000 mg/kg, the maximum dosage for rodents. In addition, no specific targets or clinical signs were detected in the present study. ACR 2,000 mg/kg-treated mice also did not show any treatment-related mortalities, clinical signs, changes to body and organ weights, or gross and histopathological findings, as compared with equal genders of vehicle control.

The Effect of Lithium Carbonate in the Treatment of Hyperthyroidism (Lithium Carbonate를 사용(使用)한 갑상선기능항진증(甲狀腺機能亢進症)의 치료(治療))

  • Lee, Gwon-Jun;Lee, Myung-Chul;Lee, Hong-Kyu;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.11 no.1
    • /
    • pp.49-58
    • /
    • 1977
  • For the assessment of antithyroid effect of lithium carbonate, it was administered to the 17 hyperthyroid and 5 euthyroid patients, who visited the Seoul National University Hospital from Jan. to Aug., 1977. Thyroid function tests were performed just before the administration of Lithium carbonate, 2 weeks and 2 months after lithium treatment. The results were as follows; 1) In the 5 euthyroid patients, no significant changes in thyroid function tests were obtained before and after lithium treatment. 2) In the 17 hyperthyroid patients, the values of the $T_3RIA$ were $370{\pm}121ng/dl$ 2 weeks after lithium treatment as compared with $506{\pm}121ng/dl$ before the administration, of which the mean percentage fall was 26.9%. $T_3RU$ was varied from $56.8{\pm}8.0%\;to\;47.3{\pm}8.1%$ (16.7% in mean percentage fall), $T_4$ was changed from $24.2{\pm}2.4ug/dl\;to\;22.0{\pm}4.2ug/dl$ (9.1% in mean fall), and $T_7$, from $13.82{\pm}2.25\;to\;10.55{\pm}3.12$ (23.7% in mean fall). 3) In the 5 hyperthyroid patients, serial thyroid function tests were performed 2 weeks and 2 months later. The mean percentage falls of $T_3RIA$ were 36.6 and 61.3%, 2 weeks and 2 months after lithium treatment respectively. Those of $T_3RU$ were 17.5 and 35.1%, those of $T_4$ were 20.4 and 44.0%, $T_7$, 35.0 and 60.7%. 4) Approximately $45{\sim}60%$ of mean fall in thyroid function tests were obtained within the second week. Normal thyroid function tests were observed in 2 among 17 patients within the second week, and 2 among 5 patients within the second month. 18 patients, however, became clinically euthyroid within the 4th week. 5) Single case of hypothyroidism was experienced, and 5 patients (29.4%) complained mild side effects. Lithium salts could be safely administered to hyperthyroid patients who are allergic to thioamides or iodine. Its use is indicated in cases of acute thyrotoxicosis in which it's necessary to reduce hormone levels very rapidly, and lithium-thioamides drug combination is a highly effective and safe means of initial routine control of hyperthyroidism.

  • PDF

A Study on the Measurement of Ultrasound Velocity to Evaluate Degradation of Low Voltage Cables for Nuclear Power Plants (원전 저압케이블 열화도 평가를 위한 초음파 음속계측에 관한 연구)

  • Kim, Kyung-Cho;Kang, Suk-Chull;Goo, Charles;Kim, Jin-Ho;Park, Jae-Seok;Joo, Geum-Jong;Park, Chi-Seung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.325-330
    • /
    • 2004
  • Several kinds of low voltage cables have been used in nuclear power plants for the supply of electric power, supervision, and the propagation of control signals. These low voltage tables must be inspected for safe and stable operation of nuclear power plants. In particular, the degradation diagnosis to estimate the integrity of low voltage rabies has recently been emphasized according to the long use of nuclear power plants. In order to evaluate their degradation, the surrounding temperature, hardness of insulation material, elongation at breaking point (EAB), etc. have been used. However, the measurement of temperature or hardness is not useful because of the absence of quantitative criteria; the inspection of a sample requires turning off of the power plant power; and, the electrical inspection method is not sufficiently sensitive from the initial through the middle stage of degradation. In this research, based on the theory that the ultrasonic velocity changes with relation to the degradation of the material, we measured the ultrasonic velocity as low voltage cables were degraded. To this end, an ultrasonic degradation diagnosis device was developed and used to measure the ultrasonic velocity with the clothing on the cable, and it was confirmed that the ultrasonic velocity changes according to the degradation of low voltage cables. The low voltage cables used in nuclear power plants were degraded at an accelerated rate, and EAB was measured in a tensile test conducted after the measurement of ultrasonic velocity. With the increasing degradation degree, the ultrasonic velocity decreased, whose potential as a useful parameter for the quantitative degradation evaluation was thus confirmed.

Study on implementation of Secure HTML5 Local Storage (안전한 HTML5 로컬스토리지 구현에 대한 연구)

  • Myeong, Hee-Won;Paik, Jung-Ha;Lee, Dong-Hoon
    • Journal of Internet Computing and Services
    • /
    • v.13 no.4
    • /
    • pp.83-93
    • /
    • 2012
  • HTML5 has developed not to have browser dependancy considering interoperability as same as maintaining compatability with lower versions of HTML. HTML5, the newest web standardization is on going of being structured. Along with the smart phone boom, HTML5 is spotlighted because it can be applied to cross platforms in mobile web environments. Specially the local Storage that has been listed in new features in HTML5 supports offline function for web application that enables web application to be run even when the mobile is not connected to 3G or wifi. With Local storage, development of server-independent web application can be possible. However Local storage stores plaintext data in it without applying any security measure and this makes the plaintext data dangerous to security threats that are already exist in other client side storages like Cookie. In the paper we propose secure Local storage methods to offer a safe way to store and retrieve data in Local storage guaranteeing its performance. Suggested functions in this paper follow localStorage standard API and use a module that provide cryptographic function. We also prove the efficiency of suggested secure Local storage based on its performance evaluation with implementation.