• Title/Summary/Keyword: sEMG(surface-Electromyography)

Search Result 106, Processing Time 0.038 seconds

Comparative Review on Oriental Medicine Study Utilized Surface Electromyography in Korea, China, Japan (표면근전도를 이용한 한국.중국.일본의 한의학연구 경향)

  • Lee, Hyung Geol;Im, Jeong Gyun;Jung, Da Jung;Kim, Jong Uk;Kim, Lak Hyung;Yook, Tae Han
    • Journal of Acupuncture Research
    • /
    • v.30 no.1
    • /
    • pp.23-34
    • /
    • 2013
  • Background or Objectives : The purpose of this study is to review oriental medicine journal that have been utilize Surface EMG in Korea, China, Japan and compare each country's trend in studies. Methods : We investigated studies in relation to surface EMG through 10 articles in Korea from OASIS, 74 articles in China from CAJ, 6 articles in Japan from J-stage. Results : Of 90 articles, 6 articles in Korea, 7 article in China, 6 articles in Japan, totally 19 articles selected. There was no big differences number of articles, type of articles among three countries. There was differences topic of articles, treatment method of articles among three countries. Conclusion : The result of this study could provide useful information of field of Surface EMG is used in Oriental medicine. Studies about Surface EMG performed in different way in Korea, China, Japan.

Study on the Validity of Surface Electromyography as Assessment Tools for Facial Nerve Palsy

  • Ryu, Hye-Min;Lee, Seung-Jeong;Park, Eun-Jin;Kim, Su-Gyeong;Kim, Kyeong Han;Choi, Yoo Min;Kim, Jong Uk;Song, Beom Yong;Kim, Cheol Hong;Yoon, Hyun-Min;Yook, Tae-Han
    • Journal of Pharmacopuncture
    • /
    • v.21 no.4
    • /
    • pp.258-267
    • /
    • 2018
  • Objectives: The purpose of this study was to find out validity of Surface Electromyography(sEMG) compared with Nerve Conduction Study and clinical assessment scale as assessment factors for facial palsy. Methods: We investigated 50 cases of patients with peripheral facial palsy who had records of sEMG and NCS to check. Then we analyzed the correlation between sEMG and NCS that carried out around 1 week after onset. And we analyzed the correlation between sEMG and clinical assessment scales that were measured three times around 1 week, 3-4 weeks and 5-6 weeks after onset. Clinical assessment scales used in this study were House-brackmann grade, Yanagihara unweighted grading scale and Sunnybrook facial grading system. We used Pearson's correlation for statistical analysis. Results: sEMG and NCS, measured at similar times, were statistically correlated. Especially, the correlation with the forehead region was high. And sEMG and clinical assessment scale, measured at same time, were statistically correlated, especially after 5 weeks from onset. Conclusion: According to this study, sEMG is expected to be useful to assessment facial palsy.

A Study of the Electrical Properties of the Buccal Area using Facial Surface Electromyography

  • Choi, Yoo Min;Kim, Jong Uk;Kim, Lak Hyung;Yook, Tae Han
    • Journal of Acupuncture Research
    • /
    • v.34 no.2
    • /
    • pp.75-82
    • /
    • 2017
  • Objectives : The purpose of this study was to determine the electrical properties of the buccal area using facial surface electromyography (sEMG). Methods : This research was conducted on 44 healthy participants irrespective of their sex. Surface electrodes were attached to the midpoints of three imaginary lines connecting ST4 (Dicang) to ST6 (Jiache), ST4 to SI18 (Quanliao), and ST4 to the center point of SI18 and ST6. Then, the participants were trained in the movement that included a comprehensive action of buccal area. While the participants were performing the motion, sEMG values ($E_1$, $E_2$, $E_3$) and the distance change of the three imaginary lines ($D_1$, $D_2$, $D_3$) were measured. The data were statistically analyzed using SPSS ver. 22.0. Results : Significant differences were observed in the distance changes ($D_1$>$D_3$, $D_2$>$D_3$) and sEMG values ($E_1$<$E_2$<$E_3$). Moreover, there were positive correlations between $D_1$ and $E_1$, $D_2$ and $E_2$. Conclusion : We suggest that the measurement at ST4 to the center point of ST6 and SI18 with this motion would be adequate to check the electrical characteristics of the buccal area.

Estimation of Shoulder Flexion Torque and Angle from Surface Electromyography for Physical Human-Machine Interaction (물리적 인간-기계 상호작용을 위한 표면 근전도 신호 기반의 어깨 굴곡 토크 및 각도 추정)

  • Park, Ki-Han;Lee, Dong-Ju;Kim, Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.6
    • /
    • pp.663-669
    • /
    • 2011
  • This paper examines methods to estimate torque and angle in shoulder flexion from surface electromyography(sEMG) signals for intuitive and delicate control of robotic assistance device. Five muscles on the upper arm, three for shoulder flexion and two for shoulder extension, were used to offer favorable sEMG recording conditions in the estimation. The methods tested were the mean absolute value (MAV) with linear regression and the artificial neural network (ANN) method. An optimal condition was sought by varying combination of muscles used and the parameters in each method. The estimation performance was evaluated using the correlation values and normalized root mean square error values. In addition, we discussed their possible use as an estimation of motion intent of a user or as a command input in a physical human-machine interaction system.

A Study of Surface Electromyography Measurement of Facial Muscles in Normal Person (정상인의 안면부 운동 시 표면근전도 측정 연구)

  • Lee, Hyung Geol;Jung, Da Jung;Choi, Yoo Min;Kim, Suk Hee;Yook, Tae Han;Song, Beom Yong;Kim, Jong Uk
    • Journal of Acupuncture Research
    • /
    • v.31 no.2
    • /
    • pp.51-63
    • /
    • 2014
  • Background or Objectives : The purpose of this study is to measure surface Electromyography(sEMG) of facial muscles in normal person and to find method for standardizing of sEMG's value. Methods : We measured 3points on face, frontalis muscle($GB_{14}$), zygomaticus muscle($SI_{18}$), orbicularis oris muscle($LI_{19}$) of 40 normal person by sEMG. 40 normal person consist with two groups, each 20 male, 20 female. Average age of subject was $26.50{\pm}4.79$. SEMG instrument QEMG-4 XL was used. After training exercise of facial muscles, sEMG's root mean square value was measured once. Results : 1. In whole experimental group, frontalis muscle's both side average was $78.36{\pm}40.87$, zygomaticus muscle's both side average was $84.70{\pm}49.81$, orbicularis oris's both side average was $104.83{\pm}38.81$. 2. Left side of Frontalis muscle, both side of zygomaticus muscle are high marked in male than female in statistically. 3. In whole experimental group, average of ratio comparing smaller value with bigger value in difference between left side and right side was $19.60{\pm}12.88$ %. 4. Average of asymmetry index(AI) was $11.46{\pm}8.36$ %. orbicularis oris muscle's average of AI had least difference was $8.95{\pm}7.50$ %. zygomaticus muscle's average of AI had most difference was $13.95{\pm}8.90$ %. Conclusions : The result of this study could provide useful information of field of sEMG is used in oriental medicine treatment of facial muscles. To assess efficacy of treatment in facial muscles, we need to standardize facial muscle's sEMG values by using AI, ratio comparing values and etc.

Human-Machine Interaction based on a Real-time Upper Limb Motion Prediction using Surface Electromyography (표면 근전도 신호를 이용한 실시간 상지부 동작 예측을 통한 인간-기계 상호작용)

  • Kwon, Sun-Cheol;Kim, Jung
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.418-421
    • /
    • 2009
  • This paper presents a human-machine interaction based on a realtime upper limb motion prediction method using surface electromyography (sEMG). The motions were predicted using an artificial neural network algorithm and sEMG signals which are acquired from five muscles, and then a manipulator was controlled to follow after the predicted motions. Upper limb motions were restricted to 2D vertical plane with the contact condition between a user and an end-effector of manipulator. In order to demonstrate the feasibility of the proposed method, experiments using developed method and using a goniometer were performed. The results showed that the proposed real-time motion prediction method can be implemented a human-machine interaction system.

  • PDF

Visualization of Motor Unit Activities in a Single-channel Surface EMG Signal

  • Hidetoshi Nagai
    • International journal of advanced smart convergence
    • /
    • v.12 no.3
    • /
    • pp.211-220
    • /
    • 2023
  • Surface electromyography (sEMG) is a noninvasive method used to capture electrically muscle activity, which can be easily measured even during exercise. The basic unit of muscle activity is the motor unit, and because an sEMG signal is a superposition of motor unit action potentials, analysis of muscle activity using sEMG should ideally be done from the perspective of motor unit activity. However, conventional techniques can only evaluate sEMG signals based on abstract signal features, such as root-mean-square (RMS) and mean-power-frequency (MPF), and cannot detect individual motor unit activities from an sEMG signal. On the other hand, needle EMG can only capture the activity of a few local motor units, making it extremely difficult to grasp the activity of the entire muscle. Therefore, in this study, a method to visualize the activities of motor units in a single-channel sEMG signal by relocating wavelet coefficients obtained by redundant discrete wavelet analysis is proposed. The information obtained through this method resides in between the information obtained through needle EMG and the information obtained through sEMG using conventional techniques.

Reliability and validity of new evaluation methods using static surface electromyography in persons with neck pain

  • Kim, Go-Eun;Yun, Dong-Uk;An, Yu-Ju;Park, Dae-Sung;Ham, Joo-Hyun
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Objective: The aim of this study was to evaluate the validity and reliability of using static surface electromyography (sEMG) on persons with neck pain and in healthy adults. Design: Cross-sectional study. Methods: Twenty-two female participants with neck pain and thirty healthy adults in the age group of 20-65 years were recruited in this study. To evaluate the validity and reliability of sEMG in subjects with neck pain, the subjects'characteristics were recorded and the Visual Analog Scale (VAS) and Neck Disability Index (NDI) were examined in addition to sEMG and algometer tests being carried out on the subjects. The site for using the sEMG and algometer was the upper trapezius. sEMG test-retest reliability was measured by intraclass correlation coefficients (ICCs). Independent t-tests were used to analyze the differences in the dependent variables between subjects with neck pain and healthy adults. The Pearson correlation coefficient was used to examine the linear relationship between measured variables. Results: sEMG and algometer tests were reliable according to the test-retest reliability results in subjects with neck pain and healthy adults (ICC=0.815-0.979). The results of this study showed that there were significant differences in respect to age, VAS, sEMG and algometer tests between persons with neck pain and healthy adults (p<0.05). The VAS and NDI were statistically correlated with sEMG and algometer results (p<0.05). Conclusions: In this study, we investigated the clinical usefulness of the static sEMG test in evaluating the pain scale of persons with neck pain with high reliability and validity.

Assessment of Muscle Fatigue Associated with Prolonged Standing in the Workplace

  • Halim, Isa;Omar, Abdul Rahman;Saman, Alias Mohd;Othman, Ibrahim
    • Safety and Health at Work
    • /
    • v.3 no.1
    • /
    • pp.31-42
    • /
    • 2012
  • Objectives: The objectives of this study were to determine the psychological fatigue and analyze muscle activity of production workers who are performing processes jobs while standing for prolonged time periods. Methods: The psychological fatigue experienced by the workers was obtained through questionnaire surveys. Meanwhile, muscle activity has been analyzed using surface electromyography (sEMG) measurement. Lower extremities muscles include: erector spinae, tibialis anterior, and gastrocnemius were concurrently measured for more than five hours of standing. Twenty male production workers in a metal stamping company participated as subjects in this study. The subjects were required to undergo questionnaire surveys and sEMG measurement. Results: Results of the questionnaire surveys found that all subjects experienced psychological fatigue due to prolonged standing jobs. Similarly, muscle fatigue has been identified through sEMG measurement. Based on the non-parametric statistical test using the Spearman's rank order correlation, the left erector spinae obtained a moderate positive correlation and statistically significant ($r_s$ = 0.552, p < 0.05) between the results of questionnaire surveys and sEMG measurement. Conclusion: Based on this study, the authors concluded that prolonged standing was contributed to psychological fatigue and to muscle fatigue among the production workers.

Usefulness of Myotonometer for Measurement of Tissue Compliance on Medialis Gastrocnemius in Patients with Stroke (뇌졸중 환자에서 내측 비복근의 조직탄성 측정을 위한 Myotonometer의 유용성)

  • Bae, Sea-Hyun;Lee, Jeong-In;Kim, Kyung-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.1129-1137
    • /
    • 2012
  • The aim of this study was to find useful parameters of the between myotonometer and surface electromyography(sEMG) on the medialis gastrocnemius of stroke patients and investigate between these parameters and modified Ashworth scale(MAS) relationship. 5 years clinical experience physical therapist using the Modified Ashworth Scale(MAS) was selected 15 patients with ankle spasticity and divided randomly MAS2, MAS3, MAS4 groups. Myotonometer and sEMG was measured during relaxed and maximum voluntary contractions of the gastrocnemius muscle. The results of this study, the higher MAS score was the lowered the relaxation and contraction state tissue compliance and muscle activity and in the correlation analysis the higher MAS score during voluntary contraction in the cylinder receiving low-intensity correlation could see that increased than relaxation. Therefore, the myotonometer is a useful clinical and research tool with spasticity muscle and can provide objective quantitative data about the efficacy of physical therapy interventions.