• Title/Summary/Keyword: running room

Search Result 84, Processing Time 0.035 seconds

A Design and Implementation of Web-based Traffic Monitoring System for Management of Small-scale PC-room (소규모 실습실 관리를 위한 웹기반 트래픽 모니터링 시스템의 설계 및 구현)

  • Lee Kang-ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.9 no.4 s.32
    • /
    • pp.127-131
    • /
    • 2004
  • In this paper, I propose the web-based network traffic monitoring system to monitor computers running MS Windows in the small-scale PC-room. The system can support network and system operation, management, expansion, and design using network analysis and diagnosis to a network administrator. The whole system consists of two parts: analysis server for collection and analysis of the network information. and supports real-time monitoring of network traffic, and the web-based interface system. a client system shows user a graphical data that analyzed a returned result from the server. This system implements web-based technology using java and contributes to enhance the effectiveness of network administrator's management activities in PC-room by controlling and monitoring.

  • PDF

A Study on the Characteristics and Satisfaction on the Interior Design of Asian Cruise Ship - Focused on the interior space of Costa Victoria - (한·중·일 크루즈 선박 실내디자인 특성 및 만족도 연구 - 코스타 빅토리아호의 실내공간을 중심으로 -)

  • Bong, Sunwha;Yoon, Jiyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.1
    • /
    • pp.328-338
    • /
    • 2013
  • This study aims at exploring the characteristics of interior design of the Cruise line running Korea, Japan and China, and the satisfaction level of the Korean passengers for the interior design. Literature review and the physical traces of the cruise ship interior including 4 types of cabins and public spaces such as main hall, restaurants, outdoor swimming pool, jogging track, theater, meeting room, duty-free shop were performed. Also, the questionnaire to the passengers were used to understand their preferences and satisfaction level for each space. The results show that the passengers are very satisfied with the color and atmosphere of the cabin, while they complain the inconvenience of the bathroom size. Also in the public space, they prefer western classic style and modern style rather than Asian or Korean style. This means that they want the exotic feeling coming out of home. Also they prefer buffet restaurant, duty-free shop, theater, observation platform compared to other public spaces. However, the problem is that there are no place for the Korean family members with young children except for the outdoor pool. The interior and the program should be redesigned for the public spacs such as cinema room, family karaoke and internet-free room for Korean passengers.

The Effect of Food Deprivation Length of Pair House Pigs on the Running Speed and Feeding Activity in Solitary and Social Conditions

  • Hsia, L.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.2
    • /
    • pp.271-277
    • /
    • 2004
  • The purpose of this experiment was to study the feeding behavior and running speed under various feed deprivation lengths and social environments. Three trials were conducted. Trial 1: ten pigs were trained individually to run a course and eat their feed at the end of the course. The pigs were deprived feed for 1, 5, 10 or 20 h. Trial 2: 1. Two pigs ran and ate together. Both pigs had 5 h of feed deprivation before the run (D5). 2. Two pigs ran and ate alone, but both pigs had 5 h of feed deprivation before the run (S5). 3. Two pigs ran and ate together. Both had 1 h of feed deprivation before the run (D1). 4. Two pigs ran and ate alone and both pigs had 1 h of feed deprivation before the run (S1). 5. Two pigs ran together, one had 5 h of feed deprivation, and the other had 1 h of feed deprivation before the run (51). Trial 3: 1. On the 1st day 5 pairs of pigs had 5 h feed deprivation and could eat feed together at (B) point (D1). 2. On the 2nd day the pigs ran and ate alone at (B) point after 5 h of feed deprivation. Feed was obtainable (D2). On the 3rd to 6th days, the pigs ran in pairs after 5 h of feed deprivation and only the dominant pig ate feed at point (B). The inferior pig was chased back to room and fed there. This stage was continued for four consecutive days, d 3 to 6. In trial 1, the running speed of pigs increased with the length of feed deprivation until 10 h, then being stable afterwards. Total feeding time increased with the length of feed deprivation (p<0.001). Eating speed did not increase with the length of feed deprivation (p>0.05). In trial 2, nine of ten pigs in treatment D5 ran faster than those in S5. Seven of the ten pigs in treatment S1 ran faster than those in treatment D1. The pigs in treatment D5 had significantly higher feed intake (p<0.001) and eating speed (p<0.05) than the pigs in other treatments. In trial 3, there were significant differences on running speed between D1 and D6 (p<0.01) and between D2 and D1, D3, D4 and D5. The inferior pig ran faster in D2 but from 3 to 6 it was the dominant pig that showed the greatest speed in completing the whole course. The results demonstrated that the pigs with low feeding motivation may cause low running speed to feed and low feed intake of the neighbor when compared with pigs kept individually.

Effects of Tribological Characteristics on Lubricants Properties (The 1st) (윤활유 성질이 마모특성에 미치는 영향(제1보))

  • 오성모;이봉구
    • Tribology and Lubricants
    • /
    • v.14 no.2
    • /
    • pp.57-62
    • /
    • 1998
  • When lubricants is used under severe running conditions, their tribological characteristics are very important. We have studied the lubricating oil viscosity, kinds of additives and their amounts, and lubricating oil temperatures were changed. In order to study the effect of oil temperature on the wear of the surface, the temperature of the oil was changed for the same sample. Moreover, the temperatures of three kinds of oils which have very different viscosities at room temperature, were varied between 6$0^{\circ}C$ and 115$^{\circ}C$ while the oil viscosity was unchanged. It was shown from the test results that surface wear is not greatly affected by the amount of ZnDTP (Zinc dialkyl dithio phosphate) antiwear agent, but EP (Extreme pressure) additives are less effective against wear than ZnDTP additives. The viscosity of lubricating oil and its temperature greatly affect the wear of the surface. Combining all the wear data with those of the surface strength, it was observed that the higher the load, the wider the scratching of wear, and also in the case of the same running load, the lower the wear, the longer the life of the surface strength.

Prediction of Trajectories of Particles Generated Underneath a Subway Train Running in An Underground Tunnel (지하터널에서 주행하는 전동차의 하부에서 발생한 입자의 이동경로 예측)

  • Lee, Kyung-Ran;Kim, Won-Geun;Yook, Se-Jin;Woo, Sang-Hee;Kim, Jong Bum;Bae, Gwi-Nam;Park, Hyung-Koo;Yoon, HwaHyeon
    • Particle and aerosol research
    • /
    • v.11 no.1
    • /
    • pp.21-28
    • /
    • 2015
  • In this study, the flow around a subway train running in an underground tunnel was numerically estimated. For the validation of the numerical results, the airflow velocity at a point underneath a subway train was measured using an ultrasonic anemometer. Then, the trajectories of particles generated at the contact points between the wheels and rails were numerically predicted. By considering the airflow velocity and particle trajectories, the space underneath the T-Car (trailer car) was expected to be appropriate for the room for the installation of a dust-removal system.

Study on Control of Refrigerant Flow Rate and Characteristics of Superheat in Evaporator using Electronic Expansion Valve (전자(電子) 팽창밸브를 이용(利用)한 증발기(蒸發器)의 냉매(冷媒) 流量(유량) 제어(制御) 및 과열도(過熱度) 특성(特性)에 관한 연구(硏究))

  • Choi, S.O.;Kim, J.H.;Yang, H.S.;Kim, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.380-387
    • /
    • 1994
  • An experimental study was performed to investigate the characteristics of refrigerant flow rate control and superheat in an evaporator with an electronic expansion valve(EEV). The EEV used in this study was devised using a needle valve coupled with a stepping motor controlled by a personal computer. A Pill control equation was used to control the superheat of the evaporator and to set the superheat to $5^{\circ}C$. In order to determine an optimum running condition for the system, Pill parameters were varied for the wide range of values. The running condition of an air conditioning system with a PI control was reasonably stable compared with that of the Pill control. Experimental results for the PI control using parameter values, $K_p=1.5$, $T_i=400(sec)$ and $T_s=6(sec)$ show that the superheat reached its target value. When external disturbances were introduced to the system, the superheat target value was reached within about 3 minutes. When the EEV was applied to the air conditioning system driven by an inverter, room temperature control was excellent.

  • PDF

Environmental Hazardous Assessment on Wood Panel Manufacturing Process (목재판넬 제조공정의 환경위험성평가)

  • Lee, Su-Gil;Lee, Nae-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.13-21
    • /
    • 2007
  • Personal and static sampling for formaldehyde, wood dust and noise monitoring, in accordance to the equipment running on the day, were carried out throughout wood panel manufacturing process. Even though the exposure level of formaldehyde and wood dust were below than exposure criteria, but the personal protective equipment(PPE) for those should be worn to everyone in the process because of its potential characteristics like carcinogenicity. Also a few local air extraction system above the cutting, grinding sections and organic blending room should be required. Most of the exposures of noise exposure were exceeded permitted exposure criteria, in case of Hopper operators, exposed to maximally 94dB(A) as LAeq 8hr, therefore active controls like PPE, monitoring, isolation etc. are necessary. The main sources of noise were caused on compressed air of the machinery, radio sound and operation noise like running machines, conveying, cutting, sawing, moving vehicles, storing and so on. For the comparison of control criteria in each country, the permitted exposure standards for above hazardous materials and noise in Korea, ACGIH and Australia were discussed. We have recognized that the Korean criteria should be discussed urgently to give the right information to employee and modified, if it is necessary.

Analysis of the Room Temperature Fitting Process for Assembling the Part(Valve Seat and Cylinder Head) (Valve Seat/Cylinder Head 단품조립을 위한 상온압입공정 해석)

  • Bae, J.H.;Kim, M.S.;Woo, T.K.;Kim, T.J.;Ho, J.D.;Kim, C.
    • Transactions of Materials Processing
    • /
    • v.18 no.8
    • /
    • pp.607-616
    • /
    • 2009
  • There are three sub-processes associated with the assembly of the valve seat and cylinder head; heat fitting, cold fitting, and shrink fitting. In the heat fitting stage, the cylinder head is heated to a specified temperature and then squeezed toward the outer diameter of the valve seat. The cold fitting process cools the valve seat and safely squeezes it toward the inner diameter of cylinder head. However, these methods increased the installations & running cost and curtailed productivity. To address these problems, we analyzed the shrink fitting process using the contact pressure caused by fitting interference between the outer diameter of the valve seat and the inner diameter of the cylinder head. In this study, a closed form equation for predicting the contact pressure and fitting load is proposed. For quality control of the assembly line, principal factors of the shrink fitting process influenced in contact pressure were simulated by the FEM. Actual loads measured in the field showed good agreement with the results obtained by theoretical and finite element analysis.

Changes in Circulatory and Respiratory Activities Observed on Men in an Engine Room of a Navy Ship (함정 기관실내 활동의 순환 및 호흡 기능에 대한 영향)

  • Hyun, Kwang-Chul;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.1 no.2
    • /
    • pp.199-213
    • /
    • 1967
  • Circulatory and respiratory activities were observed in men exposed to the environment of engine room of a cruising Republic of Korea Navy ship and compared to the control values obtained in an ordinary laboratory room on land. The environment of an engine room of cruising navy ship was presumed to be a multiple stress acting on men. The environment of the engine room included high temperature $(35-42^{\circ}C)$, low relative humidity (20-38% saturation), vibration (about 7 cycles per second), rolling and pitching of ship and noises. Sixteen men were divided into two groups consisted of each 8 subjects. Subjects of sea duty group had experience of continuous on board duty averaging 3.5 years. Men of land duty group had no experience of on board activity. On land observations were made on one day prior to the boarding and leaving the port and four days after landing. In between observations in the engine room were made on the first, 5 th, 9 th, 12 th, and 14 th day of on board activity. The whole experimental period lasted for 20 days. Measurements on circulatory and respiratory parameters were at standing resting state (after 30 minutes standing in the case of on land study and 15 minutes in engine room study) and within one minute after cessation of on the spot running of which rhythm was 30/min. and lasted for 5 minutes. Oxygen consumption and pulmonary function test were done in the period of two minutes from the 3rd to 5th minutes of running. The following results were obtained. 1. Body temperature showed no change regardless of group difference or on land or on board measurements. 2. Pulse rate increased markedly after boarding the ship id both groups. Pulse rate increased from the first day on board at rest and after exercise as compared to the on land control value. This increase in pulse rate was more marked after exercise. Sea duty group showed less increase in pulse rate at rest than the land duty group. Standing and resting pulse rate of sea duty group on lam was 81 and increased to 87 at the 5th day on board and remained smaller than the land duty group throughout the period on board. Control standing and resting pulse rate of land duty group on land was 76 and reached 89 at the 9th day on board and thereafter decreased a little. Pulse rate of land duty group at rest on board remained greater than that of sea duty group throughout the period on board. 3. Systolic blood pressure of sea duty group increased after boarding the ship and remained higher than the control value on land. In the land duty group, however, systolic blood pressure decreased during the period on board the ship. Diastolic blood pressure decreased in both groups. 4. Resting breathing rate of land duty group increased and remained higher than the control value on land. In sea duty group, however, resting breathing rate showed a transient increase on the 1st day on board and decreased thereafter to the control value on land and kept the same level throughout the period of cruise. Absolute value of breathing rate in the sea duty group was greater than the land duty group both at rest and after exercise. 5. There was a lowering of breathing efficiency in both groups. Thus, increases in tidal volume and minute ventilation volume and decreases in maximum breathing capacity, vital capacity, capacity ratio and air velocity Index were observed after boarding the ship. An increase in ventilation equivalent was also observed in both groups. The lowering of breathing efficiency was more marked in the land duty group than the sea duty group. 6. Energy expediture increased in both groups during their stay on the ship and was more marked in the sea duty group. 7, Lactate concentration in venous blood at rest and after exercise increased after boarding the ship and no group difference was observed.

  • PDF

A Study on the Characteristics of the Current Situation of the Child Care Centers for the Children with Disability in Japan - Focus on the 'Day Service for Children' in Tokyo - (일본 장애아 요육시설의 설치 및 이용현황의 특성에 관한 연구 - 일본 동경권의 '아동 데이서비스'를 중심으로 -)

  • Choi, Hee-Won
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.6
    • /
    • pp.224-232
    • /
    • 2010
  • This paper aims to identify the characteristics and the current situation of the architectural characteristics, children's characters using facilities, and status of management and utilization by surveying 'Day Service for Children' in Tokyo-do. First, About the status of management and utilization, 'Day Service for Children' is operated by a local government, NPO corporate group and social welfare corporate. There are not big differences of the care program or running hours depending on operating principals but there are differences depending on staff organization, number of children and space constitution. Also, infants ratio at 'Day Service for Children' is high for the purpose of detecting disability early and supporting their development early. They have diverse disabilities but developmental disabilities' ratios high and most children are using both this facility and normal nursery centers together. Samples for proper child care based on status of space constitutions were installing lock, raising door knobs and using softer floor materials which are for children's safety. For the problem of space utilization, most comments were about lack of space which is not enough for teaching and training materials. Therefore, as an example, observation rooms for parents and teachers were sometimes used as storages and it changes teachers' moving direction, staying area and behavior zone. The programs of 'Day Service for Children' are divided to group teaching and private one. It will be the best if they have separate spaces such as group class room, private class room and play room. When they were operated by NPO corporate group or Social welfare corporate, there are many cases that their space was not properly zoned for each activity.