• Title/Summary/Keyword: runaway test

Search Result 37, Processing Time 0.026 seconds

Thermal Hazard Evaluation on Self-polymerization of MDI

  • Sato, Yoshihiko;Okada, Ken;Akiyoshi, Miyako;Murayama, Satoshi;Matsunaga, Takehiro
    • International Journal of Safety
    • /
    • v.9 no.1
    • /
    • pp.6-11
    • /
    • 2010
  • Thermal analysis, heating test on gram scale and simulation of exothermic behavior based on kinetic analysis has been conducted in order to evaluate thermal hazards of self-polymerization of MDI. The exothermic reactions of MDI are expected to be the polymerization which forms carbodiimide and carbon dioxide, dimerization and trimerization. When MDI is kept in adiabatic condition during 1 week (10080 hours), the simulated result shows runaway reaction can occur in the case that initial temperature was more than $130^{\circ}C$. The relationship between the initial temperature (T, $^{\circ}C$) and TMR is given in a following equation. TMR=$4.493{\times}10^{-7}$ exp ($9.532{\times}10^3$/(T+273.15)) We propose that the relationship gives important criteria of handling temperature of MDl to prevent a runaway reaction.

Degradation Mechanism of ZnO Ceramic Varistors with the Time on the DC Stress Test (DC 스트레스 시간에 따른 ZnO 세라믹 바리스터의 열화기구)

  • 소순진;김영진;소병문;박춘배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.857-860
    • /
    • 2000
  • The objective of this paper is to demonstrate degradation phenomena through DC degradation tests and predicts degradation phenomena as a function of time from the tests. The ZnO varistor used in this investigation were fabricated by standard ceramic techniques. Especial, these were sintered in nitrogen atmosphere, at 2 h, for $1300^{\circ}C$. The conditions of DC degradation test were 115$\pm$$2^{\circ}C$for 0, 2, 4, and 8 h, respectively. To demonstrate the degradation phenomena of ZnO varistors, Voltagecurrent analyses were performed before and after the degradation test, and frequency analyses were used with the time of the degradation tests. It was found that the degradation occurred in not grain but grain boundary and the degradation behavior of varistors was unsymmetrically degraded with the direction of tests.

  • PDF

Construction of small hydropower facilities performance evaluation system (소수력 발전설비 성능평가 시스템 구축)

  • Kim, Youngjoon;Kim, Yongyeol;Cho, Yong;Ko, Jaemyoung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.193.2-193.2
    • /
    • 2010
  • Domestic hydroelectric power plants has been manufactured as the design condition by the demand. Hydraulic turbine power plants operating at appointed load shall be operate stable in terms of pressure, discharge, rotational speed and torque. A performance guarantees for hydro turbines shall be contain, as a minimum, guarantees covering power, discharge and specific hydraulic energy, efficiency, maximum momentary overspeed and maximum momentary pressure and maximum steady-state runaway speed, as well as guarantees related to cavitation. But, present in Korea, the absence of testing laboratories and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic hydropower machines, and makes it difficult to objectively evaluate the performance of hydro turbine. Therefore We planned making a basis of performance test of small hydropower turbine by using our flowmeter calibration system the largest one in Korea. We planned the maximum measurable power of hydro turbine will be 200 kW in our system.

  • PDF

Construction of small hydropower facilities performance evaluation system (소수력 발전설비 성능평가 시스템 구축)

  • Kim, Youngjoon;Cho, Yong;Ko, Jaemyoung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.206.2-206.2
    • /
    • 2011
  • Domestic hydroelectric power plants has been manufactured as the design condition by the demand. Hydraulic turbine power plants operating at appointed load shall be operate stable in terms of pressure, discharge, rotational speed and torque. A performance guarantees for hydro turbines shall be contain, as a minimum, guarantees covering power, discharge and specific hydraulic energy, efficiency, maximum momentary overspeed and maximum momentary pressure and maximum steady-state runaway speed, as well as guarantees related to cavitation. But, present in Korea, the absence of testing laboratories and technical criteria for the performance test of small hydropower degrades the efficiency of the domestic hydropower machines, and makes it difficult to objectively evaluate the performance of hydro turbine. Therefore We planned making a basis of performance test of small hydropower turbine by using our flowmeter calibration system the largest one in Korea. We planned the maximum measurable power of hydro turbine will be 200 kW in our system.

  • PDF

The Analysis of Factors Causing the High Prevalence of Child Obesity in Jeju Island

  • Park, Eun Hye;Oh, Min-Su;Kim, Sorina;Lee, Juyeon;Kang, Ki Soo
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.21 no.2
    • /
    • pp.127-133
    • /
    • 2018
  • Purpose: For 3 consecutive years from 2012-2014, we analyzed the causative factors for why the Jeju Island had the highest obesity prevalences of school children among the 15 provinces in Korea. Methods: From our analysis of 28,026 elementary school children with obesity or normal weight in the 15 provinces, we analyzed 12 factors related to eating habits, exercise habits, lifestyle, and mental health. The differences between the obese and normal weight children were researched. Finally, Jeju was compared with Seoul, which has the lowest obesity prevalence in school age children. Statistical analysis was performed using the chi square test of PASW Statistics ver. 18.0. Results: Compared to the normal weight group, the obese group had significantly higher rates of consuming soft drinks (p<0.001), fast food intake (p=0.019), skipping breakfast (p<0.001), insufficient sleep (p<0.001), bullying experiences (p=0.001) and runaway impulses (p=0.012). Compared to Seoul, Jeju Island had significantly higher rates of Ramen intake (3.4% vs. 5.4%, p=0.021) and meat intake (46.0% vs. 52.9%, p=0.003). On the other hand, Jeju Island was significantly lower than was Seoul in their fruit intake (83.4% vs. 67.1%, p<0.001), vegetable intake (71.4% vs. 64.2%, p=0.001), and intense physical activity (63.4% vs. 47.7%, p<0.001). Meanwhile, insufficient sleep (15.4% vs. 9.6%, p<0.001) and runaway impulses (5.6% vs. 3.3%, p=0.027) in children were significantly lower in Jeju Island than in Seoul. Conclusion: The results of the obesity factor analysis of elementary school students in Jeju Island can be used as useful educational material for lowering the obesity prevalence in Jeju community.

Thermal Resistant Characteristics of Accelerated Flowable Backfill Materials on Water Content (함수비에 따른 유동성 뒤채움재의 열저항 특성)

  • Oh, Gi-Dae;Kim, Dae-Hong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1258-1263
    • /
    • 2010
  • Backfill material of buried electrical transmission cable should dissipate the heat as rapidly as it is generated, or high temperatures will lead thermal runaway. These problems could raise thermal resistance and recude trasmission efficiency. So Backfill material of buried electrical transmission cable should have not only structual safty but good thermal property. So, in this study, we performed thermal resistancy test for various materials such as sand, weathered soil, clay and mixed soil to analyze the thermal characteristics of CLSM(controlled low strength materials) for water content.

  • PDF

Evaluation of Internal Blast Overpressures in Test Rooms of Elcetric Vehicles Battery with Pressure Relief Vents (압력배출구를 설치한 전동화 차량 배터리 시험실의 내부 폭압 평가)

  • Pang, Seungki;Shin, Jinwon;Jeong, Hyunjin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.3
    • /
    • pp.7-18
    • /
    • 2022
  • Secondary batteries used in electric vehicles have a potential risk of ignition and explosion. Various safety measures are being taken to prevent these risks. A numerical study was performed using a computational fluid dynamics code on the cases where pressure relief vents that can reduce the blast overpressures of batteries were installed in the through-compression test room, short-circuit drop test room, combustion test room, and immersion test room in facilities rleated to battery used in electric vehicles. This study was conducted using the weight of TNT equivalent to the energy release from the battery, where the the thermal runaway energy was set to 324,000 kJ for the capacity of the lithium-ion battery was 90 kWh and the state of charge (SOC) of the battery of 100%. The explosion energy of TNT (△HTNT) generally has a range of 4,437 to 4,765 kJ/kg, and a value of 4,500 kJ/kg was thus used in this study. The dimensionless explosion efficiency coefficient was defined as 15% assuming the most unfavorable condition, and the TNT equivalent mass was calculated to be 11 kg. The internal explosion generated in a test room shows the very complex propagation behavior of blast waves. The shock wave generated after the explosion creates reflected shock waves on all inner surfaces. If the internally reflected shock waves are not effectively released to the outside, the overpressures inside are increased or maintained due to the continuous reflection and superposition from the inside for a long time. Blast simulations for internal explosion targeting four test rooms with pressure relief vents installed were herein conducted. It was found that that the maximum blast overpressure of 34.69 bar occurred on the rear wall of the immersion test room, and the smallest blast overpressure was calculated to be 3.58 bar on the side wall of the short-circuit drop test room.

Comparison of steady and unsteady simulation methodologies for predicting no-load speed in Francis turbines

  • Hosseinimanesh, Hossein;Devals, Christophe;Nennemann, Bernd;Guibault, Francois
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.3
    • /
    • pp.155-168
    • /
    • 2015
  • No-load speed is an important performance factor for the safe operation of hydropower systems. In turbine design, the manufacturers must conduct several model tests to calculate the accurate value of no-load speed for the complete range of operating conditions, which are expensive and time-consuming. The present study presents steady and unsteady methods for calculating no-load speed of a Francis turbine. The steady simulations are implemented using a commercial flow solver and an iterative algorithm that relies on a smooth relation between turbine torque and speed factor. The unsteady method uses unsteady RANS simulations that have been integrated with a user subroutine to compute and return the value of runner speed, time step and friction torque. The main goal of this research is to evaluate and compare the two methods by calculating turbine dynamic parameters for three test cases consisting of high and medium head Francis turbines. Overall, the numerical results agreed well with experimental data. The unsteady method provided more accurate results in the opening angle range from 20 to 26 degrees. Nevertheless, the steady results showed more consistency than unsteady results for the three different test cases at different operating conditions.

Development of numerical model for estimating thermal environment of underground power conduit considering characteristics of backfill materials (되메움재 특성을 고려한 전력구 열환경 변화 예측 수치해석모델 개발)

  • Kim, Gyeonghun;Park, Sangwoo;Kim, Min-Ju;Lee, Dae-Soo;Choi, Hangseok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.2
    • /
    • pp.121-141
    • /
    • 2017
  • The thermal analysis of an underground power conduit for electrical cables is essential to determine their current capacity with an increasing number of demands for high-voltage underground cables. The temperature rises around a buried cable, caused by excessive heat dissipation, may increase considerably the thermal resistance of the cables, leading to the danger of "thermal runaway" or damaging to insulators. It is a key design factor to develop the mechanism on thermal behavior of backfilling materials for underground power conduits. With a full-scale field test, a numerical model was developed to estimate the temperature change as well as the thermal resistance existing between an underground power conduit and backfill materials. In comparison with the field test, the numerical model for analyzing thermal behavior depending on density, moisture content and soil constituents is verified by the one-year-long field measurement.

Optimum Condition of Micro Fuse Fusing as a Function Changed Thickness of Thermosetting Ink Epoxy (열경화성 잉크 에폭시의 두께 변화에 따른 마이크로 퓨즈 용단의 최적 조건)

  • Kim, Do-Kyeong;Hwang, Neung-Hwan;Kil, Tae-Hong;Lee, Soo-Hwa;Seo, Dae-Man;Kim, Min-Ho;Kim, Jong-Sick
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.10
    • /
    • pp.623-629
    • /
    • 2014
  • For the semiconductor device safety from over current in the digital electronic circuit system must be surely designed that it's surface mount type micro fuse device. In this paper, We has analysed to the fusing character of micro fuse as a function changed thickness of thermosetting ink epoxy. To the change of thermosetting ink epoxy thickness with in production lot, in the electrically character (fusing test in the 2 multiple over current and 10 multiple over current, surface temperature test in the 1.25 multiple over current) of micro fuse has been tested. According to the electrically character result, changed thickness of thermosetting ink epoxy in designed micro fuse withheld direct effect in both end resistance changes. Also, because high thermal energy in the micro fuse test of over current was occurred to effect such as thermal runaway and explosion. Therefore, screen printing process in the design of micro fuse using thermosetting ink epoxy is very important for production quality improvement.