• Title/Summary/Keyword: run off

Search Result 368, Processing Time 0.025 seconds

Inorganic Phosphate Has the Inhibitory Effect on Phosphotyrosyl Phosphatase Activity of Alkaline Phosphatase in Rabbit Plasma (인산에 의한 토끼 혈장 Alkaline Phosphatase의 Phosphotyrosyl Phosphatase 활성 저해)

  • Lee, Kyung Tae;Seo, Soong Hoon;Kim, Dong Hyun
    • Korean Journal of Clinical Pharmacy
    • /
    • v.9 no.1
    • /
    • pp.62-65
    • /
    • 1999
  • Inorganic phosphate (Pi) in rabbit plasma was found to block completely phosphotyrosine phosphatase (PTPase) activity without affecting the alkaline phosphatase (ALPase) activity. Our results provided that (1) PTPase activity and inhibitor are separated after G-25 gel-filtration. (2) This inhibitor is heat stable and trypsin-resistant and it can be removed by dialysis using 3 Kd cut-off tubing. (3) The elution pattern of the inhibitor is identical to that of Pi, and by performing a seperate run with inorganic phosphate. (4) The PTPase activity was recovered following an incubation with $CaCl_2$ (10 mM).

  • PDF

Relative SATD-based Minimum Risk Bayesian Framework for Fast Intra Decision of HEVC

  • Gwon, Daehyeok;Choi, Haechul
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.1
    • /
    • pp.385-405
    • /
    • 2019
  • High Efficiency Video Coding (HEVC) enables significantly improved compression performance relative to existing standards. However, the advance also requires high computational complexity. To accelerate the intra prediction mode decision, a minimum risk Bayesian classification framework is introduced. The classifier selects a small number of candidate modes to be evaluated by a rate-distortion optimization process using the sum of absolute Hadamard transformed difference (SATD). Moreover, the proposed method provides a loss factor that is a good trade-off model between computational complexity and coding efficiency. Experimental results show that the proposed method achieves a 31.54% average reduction in the encoding run time with a negligible coding loss of 0.93% BD-rate relative to HEVC test model 16.6 for the Intra_Main common test condition.

The Kinematic analysis of the third Hurdling motions of The 110m Hurdles Elite (엘리트 110m 허들선수의 세 번째 허들링 동작에 관한 운동학적 분석)

  • Lee, Jung-Ho;Park, Young-Jin;Ryu, Jae-Kyun;Kim, Jong-In
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.4
    • /
    • pp.31-39
    • /
    • 2008
  • The purposes of this study were to compare and analyze the world elite hurdler and the domestic hurdler 3-D kinematic and kinetic techniques about hurdling motion in the 110m hurdles. After analyzing variables in the 110m hurdle run the following conclusions were obtained; In a preparation phase, the domestic hurdler came out running more 0.13m then world elite hurdler from grounding to taking off in the height of center of gravity and the distance by 1.04m. In a flight phase, the domestic hurdler came out taking off 0.33m less then world elite hurdler from taking off to flight peak in the height of center of gravity and the distance by 1.63m. In a flight peak phase, domestic hurdler came out landing more 0.37m then world elite hurdler by 159m. More over, during the hurdling, the horizontal velocity of center of gravity came out decreasing from taking off to landing with domestic hurdler by 0.75m/s. the take off percentage and the landing percentage is 53:47. In a acceleration phase, domestic hurdler came out going slower 0.54m/s than world elite hurdler from landing in the horizontal velocity of center of gravity by 8.78m/s.

Soil Loss and Pollutant Load Estimation in Sacheon River Watershed using a Geographic Information System (GIS를 이용한 동해안 하천유역의 토양유실량과 오염부하량 평가 -사천천을 중심으로-)

  • Cho, Jae-Heon;Yeon, Je-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1331-1343
    • /
    • 2000
  • Through the integration of USLE and GIS, the methodology to estimate the soil loss was developed, and applicated to the Sacheon river in Gangrung. Using GIS, spatial analysis such as watershed boundary determination, flow routing. slope steepness calculation was done. Spatial information from the GIS application was given for each grid. With soil and land use map, information about soil classification and land use was given for each grid too. Based upon these data, thematic maps about the factors of USLE were made. We estimated the soil loss by overlaying the thematic maps. In this manner, we can assess the degree of soil loss for each grid using GIS. Annual average soil loss of Sacheon river watershed is 1.36 ton/ha/yr. Soil loss in forest, dry field, and paddy field is 0.15 ton/ha/yr, 27.04 ton/ha/yr, 0.78 ton/ha/yr respectively. The area of dry field, which is 4% of total area, is $2.4km^2$. But total soil loss of dry field is 6561 ton/yr, and it occupies 84.9 % of total soil loss eroded in Sacheon river watershed. Comparing with the 11.2 ton/ha/yr of an average soil loss tolerance for cropland, provision for the soil loss in dry field is necessary. Run-off and water quality of Sacheon river were measured two times in flood season: from July 24, 1998 to July 28 and from September 29 to October 1. As the run-off of the river increased, SS, TN, TP concentrations and pollutant loadings increased. SS, TN, TP loads of Sacheon river discharged during the 2 heavy rains were 21%, 39%, and 19% of the total pollutant loadings generated in the Sacheon river watershed for one year. We can see that much pollutants are discharged in short period of flood season.

  • PDF

Studies on the Maximal Oxygen Intake of the Korean - Part I. Accuracy of the Measurement of Maximal Oxygen Intake - (한국인(韓國人) 청년남여(靑年男女)의 최대산소섭취량(最大酸素攝取量)에 관(關)한 연구(硏究) - 제(第) I 편(篇) 최대효소섭취양(最大酸素攝取量) 측정치(測定値)의 변리도(變異度)에 관(關)하여 -)

  • Lee, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.1 no.1
    • /
    • pp.83-90
    • /
    • 1967
  • In order to evaluate the accuracy of the measurement of maximal oxygen intake (MOI), the MOI in seven subjects was determined 3 to 4 times in each individual. Following a 10 minute warm-up on treadmill (4.3 km/hr with 9 degree grade), the subject was asked to run at a speed of 8.73 km/hr on treadmill for a period of 3 minutes at a given grade which was elevated in a step-wise manner from zero to the level of exhaustion. Following a 3 minute run, the subject was allowed to rest for a period of 3 to 5 minutes. During each period of running, several cardio-pulmonary functions were determined and the range of variability for each measurement was computed. The oxygen consumption during the maximal work load was taken as the MOI. The results may be summarized as follows: (1) The minute volume, the oxygen consumption and the heart rate increased linearly until the grade was elevated to 9 degree above which these values were leveled off. (2) The minute volume and the heart rate during maximal exorcise were $87.4{\pm}8.10\;1/min\;and\;187{\pm}3.7$ per minute, respectively. (3) The maximal oxygen intake which corresponds to the oxygen consumption during maximal exercise was averaged to 3.04 1/min. (4) The coefficient of variance for the maximal oxygen intake was 6.32% while the corresponding values for the minute volume and the heart rate during maximal exercise were 5.22 and 2. 14%, respectively.

  • PDF

Counter-Rotating Type Pumping Unit (Impeller Speeds in Smart Control)

  • Kanemoto, Toshiaki;Komaki, Keiichi;Katayama, Masaaki;Fujimura, Makoto
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.3
    • /
    • pp.334-340
    • /
    • 2011
  • Turbo-pumps have weak points, such as the pumping operation is unstable on the positive slope of the head curve and/or the cavitation occurs at the low suction head. To improve simultaneously both weak points, the first author invented the unique pumping unit composed of the tandem impellers and the peculiar motor with the double rotational armatures. The front and the rear impellers are driven by the inner and the outer armatures of the motor, respectively. Both impeller speeds are automatically and smartly adjusted in response to the pumping discharge, while the rotational torques between both impellers/armatures are counter-balanced. Such speeds contribute to suppress successfully not only the unstable operation at the low discharge but also the cavitation at the high discharge, as verified with the axial flow type pumping unit in the previous paper. Continuously, this paper investigates experimentally the effects of the tandem impeller profiles on the pump performances and the rotational speeds against the discharge, using the impellers whose loads are low and/or high at the normal discharge. The worthy remarks are that (a) the unstable operation is suppressed as expected and the shut off power is scarcely large in the smart control, (b) the blade profile contributes to determine the discharge giving the maximum/minimum rotational speed where the reverse flow may incipiently appears at the front impeller inlet, (c) the tandem impeller profiles scarcely affect the rotational speeds, while the loads of the front and the rear impellers are same, but (d) the impeller with the low load must run faster and the impeller with the high load must run slower at the same discharge to take the same rotational torque, and (e) the reverse flow at the inlet and the swirling velocity component at the outlet of the front impeller with the high load require making the rotational speed of the rear impeller with low load fairly faster at the lower discharge.

Hot-Fire Test of a Turbopump for a 30 Ton Class Engine in Real Propellant Environment (30톤급 엔진용 터보펌프 실매질 고온시험)

  • Hong, Soon-Sam;Kim, Jin-Sun;Kim, Dae-Jin;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.11-17
    • /
    • 2009
  • Hot-fire test of a turbopump for a gas generator cycle rocket engine of 30 ton class was carried out in real propellant environment. Liquid oxygen and kerosene were used for the oxidizer pump and the fuel pump, respectively, while hot gas produced by the gas generator was supplied to the turbine. A part of the propellant discharged from the pumps was provided to the gas generator. The turbopump was run stably at both on-design and off-design conditions, satisfying all the performance requirements. This paper describes one of the test cases, where the turbopump was run for 120 seconds at three different operating modes in one test. In terms of performance characteristics of pumps and turbine, the results from turbopump assembly test using real propellant showed a good agreement with those from the turbopump component tests using simulant working fluid.

  • PDF

Prognostic Role of C-reactive Protein in Gastric Cancer: A Meta-analysis

  • Yu, Qing;Yu, Xiong-Fei;Zhang, Shou-De;Wang, Hao-Hao;Wang, Hai-Yong;Teng, Li-Song
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.5735-5740
    • /
    • 2013
  • Background: A number of studies have investigated the association between increased pretreatment serum C-reactive protein (CRP) levels and the prognosis of gastric cancer. However, due to the inconsistent results, whether the serum CRP level can be a prognostic factor in primary gastric cancer remains controversial. Methods: We searched Medline, PubMed, Embase and the Cochrane Central Register of Controlled Trials for relevant high-quality reports. A meta-analysis was carried out using the included studies to assess the association between pretreatment serum CRP level and overall survival (OS) in patients with gastric cancer. Correlation analyses were conducted to evaluate the relationship between serum CRP and tumor characteristics such as tumor node metastasis (TNM) stage and recurrence. Results: Twelve reports involving 2,597 patients with gastric cancer were included. Primary meta-analysis indicated a significant association between elevated CRP level and poor OS (HR 1.77, 95% CI 1.56-2.00). Subgroup analyses showed no single factor could alter the primary results when we divided the included studies by "number of patients", "max follow-up period", "TNM stage", "treatment" and "cut-off value". Correlation analyses showed that serum CRP level was significantly related to TNM stage (OR 2.96, 95% CI 2.22-3.93) and tumor recurrence (OR 1.81, 95% CI 1.21-2.71). Conclusions: We demonstrated that increased pretreatment serum CRP level (${\geq}10mg/L$) was significantly associated with poor prognosis in gastric cancer patients, either in early or advanced stages.

The Variation Characteristics of Indoor Radon Concentration from Buildings with Different Environment, Seoul (서울지역 건축물의 환경적 특성에 따른 실내 라돈농도 변화)

  • Jeon, Jae-Sik;Lee, Ji-Young;Eom, Seok-Won;Chae, Young-Zoo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.692-702
    • /
    • 2011
  • For more effective indoor radon reduction policy and technique, we researched radon data analysis for some buildings in Seoul. Those buildings were categorized as dwelling, underground and office space and the variations of radon concentration and its sources were evaluated. The variations of radon concentrations of indoor space of buildings for a day were patterned specifically by dwelling habits and different environment. As for the new built apartments which were not yet moved in, their indoor radon concentrations were showed more than 3 times after applying interior assembly, and were 5 times higher than ones of rather old residences. As for the subway stations, the radon concentrations during off-run times were about 15% higher than run-times. 10% of radon seemed to be reduced by installation of platform screen doors. As for office space, radon concentrations during working hours were about 2.5 times higher than non-working hours. Plaster board are expected as a main source of radon for them. By radon measurement method for long-term, its data can be over estimated because it covers non-active time in office or public space. Therefore combination of short and long-term measurement method is required for effective and economic reduction. Furthermore importance of ventilation is requested as public information service for all dwelling space. And also standardization for radium content or radiation of radon is necessary.

Real-Propellant Test of a Turbopump for a 30-Ton Thrust Level of Liquid Rocket Engine (30톤급 액체로켓엔진용 터보펌프 실매질시험)

  • Hong, Soon-Sam;Kim, Dae-Jin;Kim, Jin-Sun;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.359-365
    • /
    • 2008
  • Turbopump test for a 30-ton-thrust liquid rocket engine was carried out using real-propellant. Liquid oxygen, kerosene, cold hydrogen gas were used for the oxidizer pump, the fuel pump, the turbine, respectively. The turbopump was run stably at the design and off-design conditions and the performance requirements were satisfied, which implies that the turbopump development at the engine subsystem level is successfully accomplished in the point of performance validation. This paper presents the results of a test where the turbopump was run for 75 seconds at three operating modes. In terms of performance characteristics of pumps and turbine, the results from turbopump assembly test using real-propellant showed a good agreement with those from the turbopump component tests using simulant working fluid.

  • PDF