• Title/Summary/Keyword: rotational symmetry

Search Result 49, Processing Time 0.023 seconds

Electronic Structures of Unusual Silyltitanocene Complexes (특이한 Silyltitanocene 화합물의 전자구조)

  • An, Byeong Gak;Gang, Seong Gwon;Yun, Seok Seung
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.1
    • /
    • pp.55-60
    • /
    • 1994
  • Molecular orbital calculations at the extended Huckel level have been carried out for $Cp_2TiSiHPh(1),\;[Cp_2Ti]_2[{\mu}-HSi(HPh)][{\mu}-H] (2),\;and\;[Cp_2TiSiH_2Ph]_2$ (3) complexes which are important intermediates in organosilane polymerization. Stable geometry of complex 1 is not $C_{2V}$, but Cs symmetry and the rotational energy barrier of $SiH_2$ unit is computed to be 14 kcal/mol. The orbital interaction diagrams are studied to characterize the chemical bonding for the electron deficient systems, 2 and 3. It is possible for Si-H to be coordinated to the Ti metal using $\sigma$ bonding.

  • PDF

Optimization of extrusion process for long-length multi-filaments of BSCCO 2223 superconductor tape (고온초전도 BSCC02223 장선재 제조를 위한 압출공정의 최적화)

  • Cho, Ki-Hyun;Choi, Jong-Ung;Yoo, Jim-Moo;Ko, Jae-Woong;Kim, Hai-Doo
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.230-235
    • /
    • 2000
  • The extrusion process for long-length multi-filaments of BSCCO 2223 superconductor tape has been investigated with aids of Finite Element Method and experimental inspection. Since the arrangement of filaments in matrix material has characteristic of rotational symmetry, a 2-dimensional commercial FEM package, DEFORM-2D, was adopted to simulate extrusion process with different variables such as hardness of sheath material, lengths of each filament and arrangement. From the FEM analysis, since the inner filaments move faster than the outer one, distribution of filaments is needed to be optimized. In the case of pure Ag matrix, undesirable non-uniform distribution of filament was obtained due to low hardness of sheath material. Dummy sample(brass (sheath) and talc powder(filament)), however, which has relatively high hardness of sheath material, had been produced with desirable results. Therefore, it is necessary to optimize hardness of sheath material, extrusion temperature and billet design.

  • PDF

Molecular dynamics study of ionic diffusion and the FLiNaK salt melt structure

  • A.Y. Galashev
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1324-1331
    • /
    • 2023
  • In the present work, we carried out a molecular dynamics study of the kinetic properties of the FLiNaK molten salt, as well as a detailed study of the structure of this salt melt. The high value of the self-diffusion coefficient of fluorine ions is due to the large number of Coulomb repulsions between the most numerous negative ions. The calculated values of shear viscosity are in good agreement with the experimental data, as well as with the reference data obtained on the basis of finding the most reliable data. The total and partial functions of the radial distribution are calculated. According to the statistical analysis, fluorine ions have the greatest numerical diversity in the environment of similar ions, and sodium ions with the lowest representation in FLiNaK, have the least such diversity. For the subsystem of fluorine ions, the rotational symmetry of the fifth order is the most pronounced. Some of the fluorine ions form linear chains consisting of three atoms, which are not formed for positive ions. The results of the work give an understanding of the behavior molten FLiNaK under operating conditions in a molten salt reactor and will find application in future studies of this molten salt.

Purification and Structural Characterization of P93 Complex from Hyperthermophilic Archaeon Thermococcus profundus (초고온 archaeon인 Thermococcus profundus에서 P93 복합체의 분리 및 구조적 특성)

  • Lee, Mi-Hong;Kim, Suk-Kyoung;Yun, Young-Gun;Park, Seong-Cheol;Bahk, Jeong-Dong;Cheong, Gang-Won
    • Applied Microscopy
    • /
    • v.30 no.2
    • /
    • pp.185-191
    • /
    • 2000
  • An unusually large protein complex was found in the cytosol of the hyperthmophilic archaeon. Thermococcus profundus. The purified protein was shown to be a homomultimer of 93 kDa subunit (P93 complex). The complex is extremely heat stable. During 12 hrs incubation with SDS (final concentration 1%) at $85^{\circ}C$, no changed structure could be observed. Electron image analysis of negatively stained showed that the complex has a single, stable characteristic view and a well-preserved core with threefold rotational symmetry. The periphery of the assembly is composed of a nebulose, possibly flexible, component. Based on the projected structure suggest the P93 complex from T. profundus is composed 24 homomultimer.

  • PDF

PIV Measurement of Pulsatile Flows in 3D Curved Tubes Using Refractive Index Matching Method (3차원 곡관에서의 굴절률 일치법을 이용한 맥동 유동의 PIV 측정)

  • Hong, Hyeon Ji;Ji, Ho Seong;Kim, Kyung Chun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.8
    • /
    • pp.511-517
    • /
    • 2016
  • Three-dimensional models of stenosis blood vessels were prepared using a 3D printer. The models included a straight pipe with axisymmetric stenosis and a pipe that was bent $10^{\circ}$ from the center of stenosis. A refractive index matching method was utilized to measure accurate velocity fields inside the 3D tubes. Three different pulsatile flows were generated and controlled by changing the rotational speed frequency of the peristaltic pump. Unsteady velocity fields were measured by a time-resolved particle image velocimetry method. Periodic shedding of vortices occurred and moves depended on the maximum velocity region. The sizes and the positions of the vortices and symmetry are influenced by mean Reynolds number and tube geometry. In the case of the bent pipe, a recirculation zone observed at the post-stenosis could explain the possibility of blood clot formation and blood clot adhesion in view of hemodynamics.

The Effect of the Shift of Incident Beam on the Astigmatism (입사광의 편위가 난시안에 미치는 영향)

  • Park, Seong-Jong;Joo, Suk-Hee;Chong, Chang-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.47-52
    • /
    • 2001
  • We investigate the variation in the shape of confusion circle as the real amplitude distribution of incident beam in pupil area is shifted and the effect of the shift of incident beam on the astigmatism for eye. The shifted magnitudes of Incident beam are 0.0, 0.25, 0.5 and 0.75 and the shifted direction of incident beam ${\pi}/2$. We also consider the optical system having the astigmatism which are $0.0{\lambda}$, $0.25{\lambda}$, $0.5{\lambda}$ and $0.75{\lambda}$. As the shifted magnitude of the real amplitude distribution of incident beam increases, the shape of confusion circle on the image surface transfers from the rotational symmetry to the asymmetry like ellipse and the length of the major axis for confusion circle on the Image surface increases. We know from results in this paper that the shift of the incident beam in pupil area compensates the effect of astigmatism and the real amplitude distribution of incident beam in pupil area is shifted to minimize the effect of astigmatism for eye.

  • PDF

A Monitor Unit Verification Calculation in IMRT as a Dosimetry QA

  • Kung, J.H.;Chen, G.T.Y.;Kuchnir, F.T.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.68-73
    • /
    • 2002
  • In standard teletherapy, a treatment plan is generated with the aid of a treatment planning system, but it is common to perform an independent monitor unit verification calculation (MUVC). In exact analogy, we propose and demonstrate that a simple and accurate MUVC in Intensity Modulated Radiotherapy (IMRT) is possible. We introduce a concept of Modified Clarkson Integration (MCI). In MCI, we exploit the rotational symmetry of scattering to simplify the dose calculation. For dose calculation along a central axis (CAX), we first replace the incident IMRT fluence by an azimuthally averaged fluence. Second, the Clarkson Integration is carried over annular sectors instead of over pie sectors. We wrote a computer code, implementing the MCI technique, in order to perform a MUVC for IMRT purposes. We applied the code to IMRT plans generated by CORVUS. The input to the code consists of CORVUS plan data (e.g., DMLC files, jaw settings, MU for each IMRT field, depth to isocenter for each IMRT field), and the output is dose contribution by individual IMRT field to the isocenter. The code uses measured beam data for Sc, Sp, TPR, (D/Mu)$\_$ref/ and includes effects from MLC transmission, and radiation field offset. On a 266 MHZ desktop computer, the code takes less than 15 sec to calculate a dose. The doses calculated with MCI algorithm agreed within +/- 3% with the doses calculated by CORVUS, which uses a 1cm x 1cm pencil beam in dose calculation. In the present version of MCI, skin contour variations and inhomogeneities were neglected.

  • PDF

Crystal Structure of Penicillin V Potassium Salt

  • Kim, Whan-Chul;Yi, Seung-Ho;Shin, Jung-Mi;Yoon, Tae-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.6
    • /
    • pp.713-717
    • /
    • 1993
  • The crystal structure of the potassium salt of penicillin V has been studied by the X-ray crystallographic methods. Crystal data are as follows; potassium 3,3-dimethyl-7-oxo-6-phenoxyacetoamido-4-thia-1- azabicyclo[3.2.0]-heptane-2${\alpha}$-carboxylate, $K^+{\cdot}C_{16}H_{18}N_2O_5S^-$, $M_r$= 388.5, triclinic, Pl, a= 9.371 (1), b= 12.497 (2), c= 15.313 (2) ${\AA},\;{\alpha}= 93.74\;(2),\;{\beta}=99.32\;(1),\;{\gamma}=90.17\;(1)^{\circ},\;V=1765.7\;(2)\;{\AA}^3$, Z=4, $D_m=1.461\;gcm^{-1},\;{\lambda}(Cu\;K{\alpha})=1.5418\;{\AA},\;{\mu}=40.1\;cm^{-1}$, F(000)=808, T=296 K. The structure was solved by the heavy atom and difference Fourier methods with intensity data measured on an automated four-circle diffractometer. The structure was refined by the full-matrix least-squares method to a final R= 0.081 for 3563 observed $[I_0{\geq}2{\sigam}(I_0)]$ reflections. The four independent molecules assume different overall conformations with systematically different orientations of the phenyl groups although the penam moieties have the same closed conformations. There are intramolecular hydrogen bonds between the exocyclic amide nitrogen and phenoxy oxygen atoms. The penam moiety is conformationally very restricted although the carboxyl and exocyclic amide groups apparently have certain rotational degrees of freedom but the phenyl group is flexible about the ether bond despite the presence of the intramolecular N-H${\cdots}$O hydrogen bond. There are complicated pseudo symmetric relationships in the crystal lattice. The penam moieties are related by pseudo 20.5 screw axes and the phenyl groups by pseudo centers of symmetry. The potassium ions, related by both pseudo symmetries, form an infinite zigzag planar chain parallel to the b axis. Each potassium ion is coordinated to seven oxygen atoms in a severely distorted pentagonal bipyramid configuration, forming the infinite hydrophilic channels which in turn form the molecular stacks. Between these stacks, there are only lipophilic interactions involving the phenyl groups.

Paraboloidal 2-mirror Holosymmetric System with Unit Maginification for Soft X-ray Projection Lithography (연X-선 투사 리소그라피를 위한 등배율 포물면 2-반사경 Holosymmetric System)

  • 조영민;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.188-200
    • /
    • 1995
  • A design of unit magnification 2-mirror system with high resolution is presented. It is for soft X-ray(wavelength of 13 nm) projection imaging and suitable for preparation of high density semiconductor chip. In general, a holosymmetric system with unit magnification has the advantage that both coma and distortion are completely eliminated. In our holosymmetric 2-mirror system, spherical aberration is addtionally removed by using two identical paraboloidal mirror surfaces and field curvature aberration is also corrected by balancing Petzval sum and astigmatism which depends on the distance between two mirrors, so that the system is a aplanatic flat-field paraboloidal 2-mirror holosymmetric system. This 2-mirror system is small in size, and has a simple configuration with rotational symmetry about optical axis, and has also small central obscuration. Residual finite aberrations, spot diagrams, and diffraction-based MTF's are analyzed for the check of performances as soft X-ray lithography projection system. As a result, the image sizes for the resolutions of$0.25\mum$and $0.18\mum$are 4.0 mm, 2.5 mm respectively, and depths of focus for those are $2.5\mum$, $2.4\mum$respectively. This system should be useful in the fabrication of 256 Mega DRAM or 1 Giga DRAM. DRAM.

  • PDF