• Title/Summary/Keyword: rotational

Search Result 3,863, Processing Time 0.039 seconds

Software development for the visualization of brain fiber tract by using 24-bit color coding in diffusion tensor image

  • Oh, Jung-Su;Song, In-Chan;Ik hwan Cho;Kim, Jong-Hyo;Chang, Kee-Hyun;Park, Kwang-Suk
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.133-133
    • /
    • 2002
  • Purpose: The purpose of paper is to implement software to visualize brain fiber tract using a 24-bit color coding scheme and to test its feasibility. Materials and Methods: MR imaging was performed on GE 1.5 T Signa scanner. For diffusion tensor image, we used a single shot spin-echo EPI sequence with 7 non-colinear pulsed-field gradient directions: (x, y, z):(1,1,0),(-1,1,0),(1,0,1),(-1,0,1),(0,1,1),(0,1,-1) and without diffusion gradient. B-factor was 500 sec/$\textrm{mm}^2$. Acquisition parameters are as follows: TUTE=10000ms/99ms, FOV=240mm, matrix=128${\times}$128, slice thickness/gap=6mm/0mm, total slice number=30. Subjects consisted of 10 normal young volunteers (age:21∼26 yrs, 5 men, 5 women). All DTI images were smoothed with Gaussian kernel with the FWHM of 2 pixels. Color coding schemes for visualization of directional information was as follows. HSV(Hue, Saturation, Value) color system is appropriate for assigning RGB(Red, Green, and Blue) value for every different directions because of its volumetric directional expression. Each of HSV are assigned due to (r,$\theta$,${\Phi}$) in spherical coordinate. HSV calculated by this way can be transformed into RGB color system by general HSV to RGB conversion formula. Symmetry schemes: It is natural to code the antipodal direction to be same color(antipodal symmetry). So even with no symmetry scheme, the antipodal symmetry must be included. With no symmetry scheme, we can assign every different colors for every different orientation.(H =${\Phi}$, S=2$\theta$/$\pi$, V=λw, where λw is anisotropy). But that may assign very discontinuous color even between adjacent yokels. On the other hand, Full symmetry or absolute value scheme includes symmetry for 180$^{\circ}$ rotation about xy-plane of color coordinate (rotational symmetry) and for both hemisphere (mirror symmetry). In absolute value scheme, each of RGB value can be expressed as follows. R=λw|Vx|, G=λw|Vy|, B=λw|Vz|, where (Vx, Vy, Vz) is eigenvector corresponding to the largest eigenvalue of diffusion tensor. With applying full symmetry or absolute value scheme, we can get more continuous color coding at the expense of coding same color for symmetric direction. For better visualization of fiber tract directions, Gamma and brightness correction had done. All of these implementations were done on the IDL 5.4 platform.

  • PDF

Comparison of Misalignment and Retardation Errors of Dual Rotating Quarter-Wave Plates in Muller-Matrix Ellipsometry (타원편광 분석기에서 정렬오차와 사분파장판의 지연오차로 인한 뮬러 매트릭스 오차 분석)

  • Cheong, Hai Du;Kim, Dukhyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.5
    • /
    • pp.262-272
    • /
    • 2014
  • Using an ellipsometer with dual rotating quarter-wave plates, we have analyzed the relationship between Fourier coefficients and Mueller matrices in the cases of an error-free optical system and of five systematic errors (alignment errors and retardation errors in the quarter-wave plates, and alignment error in the analyzer). In the case with five systematic errors, simulation results show that retardation errors cause more error in the diagonal elements of the Mueller matrix than do alignment errors. We have found that errors in the Mueller matrix caused by initial misalignment of the dual quarter-wave plates were the same. We have chosen the rotation rates of two quarter-wave plates such that the rotational frequencies ${\omega}_1$ and ${\omega}_2$ differ by a factor of 5, i.e. ${\omega}_2=5{\omega}_1$. The simulation results show 0.18% relative error in the diagonal elements ($m_{22}$ and $m_{33}$) and 200% relative error in the off-diagonal elements ($m_{23}$ and $m_{32}$), when we compare errors caused by misalignment of the analyzer to those caused by initial misalignment of the quarter-wave plates. We can use these results in measuring accurate Mueller matrices of optical materials.

The effect of treatment timing on maxillary protraction treatment response - A comparison of prepubertal and pubertal patients (치료시기에 따른 상악골 전방견인효과 - 사춘기전과 사춘기의 비교)

  • Kim, Kyung-Ho;Choy, Kwang-Chul;Baik, Hyoung-Seon;Lee, Ji-Hyun
    • The korean journal of orthodontics
    • /
    • v.32 no.5 s.94
    • /
    • pp.301-312
    • /
    • 2002
  • Treatment timing is a very important factor to consider in treating skeletal Class III patients by means of maxillary protraction. According to the literature maxillary Protraction should be carried out at an early age before puberty. However, no scientific data were presented to support this statement and recent studies supported by statistical data showed disagreement concerning the optimum treatment time of maxillary protraction. Therefore, there is no agreement about the optimum treatment time of maxillary protraction. In this study hand-wrist X-rays were taken from 119 patients and subjects were grouped into prepubertal and pubertal group according to their skeletal maturity. Pretreatment and posttreatment lateral cephalometric X-rays were taken and treatment effects were compared. The average treatment time was 6.5 months for the prepubertal group and 6.1 months for the pubertal group. The obtained results were as follows ; 1. The amount of maxillary forward movement was the same for Pretreatment and pubertal group. 2. The amount of maxillary downward movement was the same for prepubertal and pubertal group. 3. The amount of mandibular downward and backward rotational movement was the same for prepubertal and pubertal group. 4. Dental effects were the same for prepubertal and pubertal group.

Rheological Properties of Gelatinized Model Foods (모형식품의 리올로지 특성)

  • Chun, Ki-Chul;Park, Young-Deok;Chang, Kyu-Seob
    • Korean Journal of Agricultural Science
    • /
    • v.22 no.1
    • /
    • pp.103-109
    • /
    • 1995
  • The model foods were prepared by simulating mositure, protein and starch, and they were heated for 30 mins, at $80^{\circ}C$ and then cooled at $25^{\circ}C$ in water bath. Their rheological properties were investigated by the use of Brookfield wide-gap rotational viscometer at $30{\sim}60^{\circ}C$, and the rotation speed ranged from 0.6 to 6 rpm and solid content ranged from 8% to 11%, the results obtained were as follows. 1. All the model foods ($P_1S_3$, $P_2S_2$, $P_1S_1$, $P_2S_1$, $P_3S_1$, $P_4S_0$) exhibited pseudoplastic behaviors with yeild stress and were thixotropic foods which showed time - dependent structural decays, but the starch food of 8 ~ 11 % solid content did not show the flow behavior. 2. The correlation between the rheological parameters and the protein content of model foods in various moisture content did not appeared a constant relationship. 3. The change of shear stress against shear rate in high starch foods was larger than that in high protein foods and the structure at initial shear time was decayed with a quatic equation according to the Tiu's Model and structural decay was in parallel with the increase of shear rate. 4. The temperature dependency of the apparent viscosity of $P_1S_2$, and $P_2S_1$ was fully expressed by Arrhenius equation and activation energies of their food were 2.35 and $1.34Kcal/g{\cdot}mol$, respectively.

  • PDF

Structural Design and Analysis of a Hydraulic Coiling Arm for Offshore Wind-turbine Submarine Cable (해상풍력 해저케이블 하역용 유압식 코일링 암 구조설계 및 해석)

  • Kim, Myung-Hwan;Kim, Dong-Hyun;Oh, Min-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Structural design and analysis of a coiling arm unloading machine for submarine cable have been originally conducted in this study. Three-dimensional CAD modeling process is practically applied for the structural design in detail. Finite element method(FEM) and multi-body dynamics(MBD) analyses are also used to verify the safety and required motions of the designed coiling arm structure. The effective moving functions of the designed coiling arm with respect to rotational and radial motions are achieved by adopting bearing-roller mechanical parts and hydraulic system. Critical design loading conditions due to its self weight, carrying cables, offshore wind, and hydraulic system over operation conditions are considered for the present structural analyses. In addition, possible inclined ground conditions for the installation of the designed coiling arm are also considered to verify overturn stability. The present hydraulic type coiling arm system is originally designed and developed in this study. The developed coiling arm has been installed at a harbor, successfully tested its operational functions, and finished practical unloading mission of the submarine cable.

A Study on the Determination of Slot's Number of Rotor to Reduce Noise and Vibration and Design the 3-Phase Induction Motor Considering Kinetic Energy in Flywheel Energy Storage System (운동 에너지를 고려한 Flywheel Energy Storage System 설계와 진동 저감을 위한 3상 유도기의 슬롯수 산정에 관한 연구)

  • Ryu, Jae Ho;Kim, Hui Min;Lee, Chee Woo;Park, Gwan Soo;Jeong, Dong Wook
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Flywheel Energy Storage System (FESS) is composed by flywheel generating rotating potential energy and motor/generator set charging and discharging electric potential energy. The flywheel and motor/generator is connected by rotating shaft. And torque characteristics of motor/generator part can influence charging and mechanical traits of FESS. This paper analyze about motor/generator design method of 5 [kWh] FESS and torque ripple, harmonic effects by change of slots. At First, this paper proposes a method to estimate the flywheel size and the rotor size of the motor from the the rotational kinetic energy by inertia of FESS. The number of induction motor rotor slots for torque ripple reduction in the high speed operation region is selected. This paper performs to reduce the noise and vibration of the flywheel composed of coaxial with motor/generator and flywheel and realize the high efficiency.

Paraboloidal 2-mirror Holosymmetric System with Unit Maginification for Soft X-ray Projection Lithography (연X-선 투사 리소그라피를 위한 등배율 포물면 2-반사경 Holosymmetric System)

  • 조영민;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.188-200
    • /
    • 1995
  • A design of unit magnification 2-mirror system with high resolution is presented. It is for soft X-ray(wavelength of 13 nm) projection imaging and suitable for preparation of high density semiconductor chip. In general, a holosymmetric system with unit magnification has the advantage that both coma and distortion are completely eliminated. In our holosymmetric 2-mirror system, spherical aberration is addtionally removed by using two identical paraboloidal mirror surfaces and field curvature aberration is also corrected by balancing Petzval sum and astigmatism which depends on the distance between two mirrors, so that the system is a aplanatic flat-field paraboloidal 2-mirror holosymmetric system. This 2-mirror system is small in size, and has a simple configuration with rotational symmetry about optical axis, and has also small central obscuration. Residual finite aberrations, spot diagrams, and diffraction-based MTF's are analyzed for the check of performances as soft X-ray lithography projection system. As a result, the image sizes for the resolutions of$0.25\mum$and $0.18\mum$are 4.0 mm, 2.5 mm respectively, and depths of focus for those are $2.5\mum$, $2.4\mum$respectively. This system should be useful in the fabrication of 256 Mega DRAM or 1 Giga DRAM. DRAM.

  • PDF

A Study on Yongin -Ansung Landslides in 1991 (1991년 용인 -안성 지역 산사태 연구)

  • Park, Yong-Won;Kim, Gam-Rae;Yeo, Un-Gwang
    • Geotechnical Engineering
    • /
    • v.9 no.4
    • /
    • pp.103-118
    • /
    • 1993
  • This paper presents the results of investigation of the rainstorm induced landslides occurred in the districts of Yongin, Ansung and Osan on July 21st 1991. More than two thousand and sirs hundred landsilides took place during or after a 3-t hours heavy rainfall and about 466 ha mountain slopes were affected by slope failures. The result of study on the effect of-iainfall on landslides shows that landslides began to occur where daily and maximum hourly rainfall exceeded 114mm and 40mm respectively, and all districts (myun) where maximum hourly rainfall exceeded 62mm were affected by landslides. The morphological study on landslides on Talbongsan area reveals that, by Walker's classi fication using D IL(failure depth ratio), 50% of the landslides were classified as flows, 20% of them as translational slides, and 30% were between flow and slide and there were few rotational slides. Over 90% of landslides tookplace at slopes of 20$^{\circ}$-40$^{\circ}$ in slope and 50m or shorter in length And more than 50% of the crown of slides locates at higher than 0.7 times of slope hight. Any differences between the kinds of tree in landslide resisting effects are shown in this case.

  • PDF

INFLUENCE OF TUNGSTEN CARBIDE/CARBON COATING ON THE PRELOAD OF IMPLANT ABUTMENT SCREWS (임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중에 미치는 영향에 관한 연구)

  • Choi Jin-Uk;Jeong Chang-Mo;Jeon Young-Chan;Lim Jang-Seop;Jeong Hee-Chan;Eom Tae-Gwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.229-242
    • /
    • 2006
  • Statement of problem: In order to increase preload with reducing the friction coefficient, abutment screws coated with pure gold and Teflon as dry lubricant coatings have been introduced. But the reported data indicate that if screw repeated tightening and loosening cycle, an efficiency of increasing preload was decreased by screw surface wearing off. Purpose: This study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on the preload of abutment screws and the stability of coating surface after repeated closures. Material and method: The rotational values of abutment screws and the compressive forces between abutment and fixture were measured in implant systems with three different joint connections, one external butt joint and two internal cones. Moreover the stability and the alteration of coating surface were examined by comparison of the compressive force and the removable torque values during 10 consecutive trials, observation with scanning electron microscope and analyzed the elemental composition with energy dispersive x-ray spectroscopy Results and conclusion: 1. Application of coating resulted in significant increase of compressive force in all implant systems(P<.05). The increasing rate of compressive force by coating in external butt joint was gloater than those in internal cones (P<.05). 2. Coated screw showed the significant additional rotation compared to non-coated screw in all implant systems (P<.05). There were no significant differences in the increasing rate of rotation among implant systems (P>.05). 3. Removable torque values were greater with non-coated screw than that with coated screw (P<.05). 4. Coated screw showed insignificant variations in the compressive forces during 10 consecutive trials(P>.05) 5. After repeated trials, the surface layer of coated screw was maintained relatively well. However surface wearing and irregular titanium fragments were found in non-coated screw.

Open Techniques for Bone Defect in Anterior Shoulder Instability (골 결손이 동반된 전방 견관절 불안정성에서 개방적 수술 술기)

  • Lee, Bong-Gun;Rhee, Yong-Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.255-263
    • /
    • 2009
  • Purpose: An osseous defect in the glenoid and humeral head is closely associated with recurrence of anterior shoulder instability. The purpose of this article is to describe the open surgical techniques and introduce our experiences with anterior instability with a significant osseous defect. Materials and Methods: We reviewed the articles that have focused on and/or mentioned the affect of osseous defects on anterior shoulder instability. The open surgical techniques and its related pearls are summarized in this review. Results: Accurate evaluation for the size and location of the osseous defect is critical for preventing recurrence after restoration of the anterior capsulolabral structure. The glenoid bone restoration techniques include the coracoids transfer (the Bristow procedure and the Latarjet procedure) and a structural iliac bone graft. Rotational humeral osteotomy and an osteoarticular allograft could be used for repairing a significant posterosuperior humeral defect (Hill-Sachs lesion). Shoulder arthroplasty may be tried for treating a humeral bone defect, but more study on this is needed. Conclusion: Open surgical restoration decreases the risk of recurrence anterior shoulder instability that is combined with a significant osseous defect. Arthroscopic surgery currently has limitations for treating an osseous defect, but it will become useful in proportion to the development of arthroscopic instruments and techniques in the future.