• 제목/요약/키워드: rotation correction

검색결과 178건 처리시간 0.026초

실시간 회전영상 안정화를 위한 회전중심 및 회전각도 추정 방법 (Estimation of Rotation Center and Rotation Angle for Real-time Image Stabilization of Roll Axis.)

  • 조재수;김도종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.153-155
    • /
    • 2004
  • This paper proposes a real-time approach on the rotational motion estimation and correction for the roll stabilization of the sight system. This method first estimates a rotation center by the least-mean square algorithm based on the motion vectors of some feature points. And, then, a rotation angle is searched for a best matching block between a reference block image and seccessive input images using MPC(maximum pixel count) matching criterion. Finally, motion correction is performed by the bilinear interpolation technique. Various computer simulations show that the estimation performance is good and the proposed algorithm is a real-time implementable one to the TMS320C6415(500MHz) DSP.

  • PDF

SIMULATION OF IMAGE DISTORTON AND ITS CORRECTION BY OBSERVER'S ROTATION MOVEMENT IN STEREOSCOPIC DISPLAY

  • Kim, Dong-Wook;Lee, Kwang-Hoon;Chang, Eun-Young;Kim, Jin-Woong;Kim, Sung-Kyu
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2009년도 IWAIT
    • /
    • pp.360-363
    • /
    • 2009
  • Variation of viewing position of the observer is one of factors of image distortion in the stereoscopic display. A rotation movement of the observer makes the stereoscopic image distortion and that is caused by different horizontal position of each eye of the observer. It is different from horizontal and depth directional movement of the observer. In this paper, we showed the numerical simulation result about the distortion analysis and the correction of the stereoscopic image in rotation movement of the observer.

  • PDF

방사선수술치료계획 프로그램의 지시자 회전 오차 교정 기능 점검 (Verification of Indicator Rotation Correction Function of a Treatment Planning Program for Stereotactic Radiosurgery)

  • 정현태;이레나
    • Journal of Radiation Protection and Research
    • /
    • 제33권2호
    • /
    • pp.47-51
    • /
    • 2008
  • 목 적: 방사선수술에 사용되는 치료계획을 위한 정위 영상 획득 때 사용되는 표시기(indicator)의 회전에 의한 오차를 분석하고 이를 교정하는 소프트웨어의 기능을 점검하는 방법을 제시한다. 이 방법을 이용하여 상용 프로그램인 렉셀감마플랜의 회전 오차 기능을 점검한다. 대상 및 방법: 상용 프로그래밍 언어인 Interactive Data Language (version 5.5)를 이용하여 소프트웨어적으로 만든 정위 영상으로 가상 팬텀을 만들었다. 영상의 두께는 0.5 mm, 픽셀 크기 0.5 mm, 필드 크기 256 mm, 그리고 분해능은 $512{\times}512$이었다. 영상은 DICOM 3.0 표준을 따라서 렉셀감마플랜이 인식할 수 있도록 하였다. 회전 교정 기능 점검을 위하여 가상 팬텀의 중심에서 상하로 50 mm와 30 mm 떨어진 곳과 중앙에 위치한 횡단면 영상에 각각 50 mm 간격으로 측정점 9개를 만들어 총 45개의 측정점을 만들었다. 기준 가상 팬텀을 x, y, z축을 중심으로 각각 $3^{\circ}$ 회전한 영상, xy, yz, zx 축을 중심으로 각각 $3^{\circ}$씩 회전한 영상, xyz세 방향으로 모두 $3^{\circ}$씩 회전한 영상을 만들어서 회전에 의한 오차를 계산하고, 렉셀감마플랜의 교정 기능을 점검하였다. 결과: 가상 영상을 렉셀감마플랜에 입력하고 정위좌표를 정의할 때 영상에 의한 등록 오차는 $0.1{\pm}0.1mm$로써 방사선수술에서 요구하는 오차 내에 있었다. x, y, z축 중 1개 축을 중심으로 $3^{\circ}$ 회전할 때 가능한 최대 오차는 2.6mm, 2개 축을 중심으로 $3^{\circ}$씩 회전할 때는 3.7mm, 3개축 모두에 대해 $3^{\circ}$씩 회전할 때는 4.5 mm이다. 이에 대해 영상의 회전을 교정하여 렉셀감마플랜에서 측정한 측정점들의 변위는 1 개축을 중심으로 회전하였을 때 $0.1{\pm}0.1mm$, 2 개 축의 경우 $0.2{\pm}0.2mm$, 3개축의 경우 $0.2{\pm}0.2mm$로서 회전의 영향을 보정하는 기능이 정확하게 작동하고 있음을 확인할 수 있었다. 결론: 방사선수술 치료계획 프로그램의 여러 소프트웨어적 기능을 점검하기 위한 가상 팬텀을 만들고 상용프로그램의 회전 오차 교정 기능을 점검한 결과 정확하게 작동하고 있음을 확인하였다. 본 연구에서 작성한 가상 팬텀은 치료계획 프로그램의 다른 여러 기능들을 점검하는 데도 사용될 수 있을 것이다.

The effect of the tongue in groove technique on the nasolabial angle and nasal tip projection

  • Khabir, Fatemeh;Sezavar, Mehdi;Bohluli, Behnam;Mesgarzadeh, Vahid;Tavakoli, Hamidreza
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.19.1-19.4
    • /
    • 2020
  • Background: The tongue in groove technique (TIG) is a useful technique for the correction of the nasal tip projection and the nasolabial angle. The purpose of this study was to determine the utility of this technique for nasal tip rotation and projection correction in the Iranian society. Methods: This is a retrospective clinical trial study of 20 patients undergoing open septo-rhinoplasty using TIG technique from January 2017 to August 2019 at the oral and maxillofacial unit of Bu Ali Hospital and private sector. Preoperative and postoperative profile view photographs were compared to assess the changes in tip projection and rotation. Results: Fifteen patients (75%) had normal angular size, and 5 of them (25%) were not within the normal range after the surgery. The Fisher exact test showed that this success was statistically significant (P = 0.006). Ten patients (50%) had normal projection size, postoperatively. The Fisher exact test showed that this effect was statistically significant (P < 0.01) Conclusion: The study demonstrated the benefit of TIG on the correction of nasal tip projection and rotation.

PDA에서의 명함 영상의 기울기 보정 (Skew Correction of Business Card Images for PDA Application)

  • 박준효;장익훈;김남철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 Ⅳ
    • /
    • pp.2128-2131
    • /
    • 2003
  • We present an efficient algorithm for skew correction of business card images obtained by a PDA camera. The proposed method is composed of four parts: block adaptive binarization (BAB), stripe generation, skew angle calculation, and image rotation. In the BAB, an input image is binarized block by block so as to lessen the effects of irregular illumination and shadows over the input image. In the stripe generation, character string clusters are generated merging character strings and their inter-spaces, and then only clusters useful for skew angle calculation are output as stripes. In the skew angle calculation, the direction angles of the stripes are calculated using their central moments and then the skew angle of the input image is determined averaging the direction angles. In the image rotation, the input image is rotated by the skew angle. Experimental results shows that the proposed method yields correction rates of 97% for business card images.

  • PDF

신경가동운동과 견갑골 자세교정운동이 오십견 환자에게 미치 는 영향 (Effects of Nerve Mobilization Exercise and Scapula Postural Correction Exercise for Adhesive Capsulitis Patients)

  • 정민근;김유리;김완기;전재국
    • 대한정형도수물리치료학회지
    • /
    • 제24권1호
    • /
    • pp.57-65
    • /
    • 2018
  • Background: This study examined the effects of nerve mobilization exercise and scapula postural correction exercise and scapula postural correction exercise after applying conservative physical therapy to frozen shoulder. Methods: Thirty-four outpatients were divided into a nerve mobilization exercise and scapula postural correction exercise group and scapula postural correction exercise group. Each group performed its own exercise 30 minutes per day, three times per week, for 6 weeks. Pain intensity was measured by the visual analogue scale. Range of motion was measured by the goniometer. The scapular position was measured by scapular index. Grasping power was measured by the Grip Track Commander. Measurements were made at baseline and six weeks after the intervention. Results: the visual analogue scale, range of motion (except lateral rotation), and grasping power for each group showed significant changes at baseline and six weeks after the intervention (p<.05). Significant differences were also evident between the two groups for these three measurements (p<.05). Conclusions: Nerve mobilization exercise & scapula postural correction exercise is more effective than scapula postural correction exercise for reducing pain intensity and increasing grasping power, scapular index and range of motion (except lateral rotation) in frozen shoulder syndrome patients.

심각한 외측 회전을 동반한 전완 기형의 외과적 교정 치료 2 증례 (Surgical Correction of an Antebrachial Deformity with Severe External Rotation in Two Dogs)

  • 윤헌영;노미영;정순욱
    • 한국임상수의학회지
    • /
    • 제28권3호
    • /
    • pp.328-331
    • /
    • 2011
  • 간헐적 전지 파행을 보이는 두 마리 개가 내원하였다. 신체 검사에서 약 $90^{\circ}$ 외측 회전을 동반한 전완 기형을 두 마리 모두에서 확인 하였다. 일반 방사선 사진에서 척골 원위부 아탈구, 요골 앞쪽 휨 현상, 짧아진 요골 척골, 및 앞발의 외측 회전을 확인하였다. 외측 회전을 동반한 전완 기형의 교정을 위해 척골 원위부 골절제와 요골 원위부 쐐기형 절골술 및 요골 원위부 내측 회전을 실시 하였다. 관절 부조화를 예방하기 위해 척골 근위부 절골술을 첫 번째 개에서 실시 하였다. 수술 후 정기 검진은 수의사의 신체 검사를 통해 실시 되었으며 두 마리 모두에서 수술과 관련한 합병 증상 및 파행이 없음을 확인하였다.

ACTIVATOR를 이용한 편측성 구치부 반대교합의 치험예 (A CASE REPORT OF UNILATERAL POSTERIOR CROSS BITE BY THE ACTIVATOR)

  • 담재화;전윤식
    • 대한치과교정학회지
    • /
    • 제18권2호
    • /
    • pp.449-458
    • /
    • 1988
  • The author evaluated the effect of wunderer activator and karwetzky's u-bow activator for correction of anterior and posterior cross bite and mandibular shift to the Rt. or Lt. side. The results were as follows. 1. correction of anterior and posterior cross bite. 2. correction of mandibular shift to the unilateral side. 3. slightly down and backward rotation of mandible was occured.

  • PDF

HI LINEWIDTHS, ROTATION VELOCITIES AND THE TULLY-FISHER RELATION

  • Rhee, Myung-Hyun;Broeils, Adrick H.
    • Journal of Astronomy and Space Sciences
    • /
    • 제22권2호
    • /
    • pp.89-112
    • /
    • 2005
  • We determine the rotation velocities of 108 spiral and irregular galaxies (XV-Sample) from first-order rotation curves from position-velocity maps, based on short 21-cm observations with the Westerbork Synthesis Radio Telescope (WSRT). To test the usual random motion corrections, we compare the global HI linewidths and the rotation velocities, obtained from kinematical fits to two-dimensional velocity fields for a sample of 28 galaxies (RC-Sample), and find that the most frequently used correction formulae (Tully & Fouque 1985) are not very satisfactory. The rotation velocity parameter (the random-motion corrected HI linewidth: W?), derived with these corrections, may be statistically equal to two times the true rotation velocity, but in individual cases the differences can be large. We analyse, for both RC- and XV-Samples, the dependence of the slope of, and scatter in the Tully-Fisher relation on the definition of the rotation velocity parameters- For the RC-Sample, we find that the scatter in the Tully-Fisher relation can be reduced considerably when the rotation velocities derived from rotation curves are used instead of the random-motion corrected global H I linewidths. No such reduction in the scatter is seen for XV-Sample. We conclude that the reduction of the scatter in the Tully-Fisher relation seems to be related to the use of two-dimensional velocity information: accurate rotation velocity and kinematical inclination.

SIFT 특징을 이용한 의료 영상의 회전 영역 보정 (Correction of Rotated Region in Medical Images Using SIFT Features)

  • 김지홍;장익훈
    • 한국멀티미디어학회논문지
    • /
    • 제18권1호
    • /
    • pp.17-24
    • /
    • 2015
  • In this paper, a novel scheme for correcting rotated region in medical images using SIFT(Scale Invariant Feature Transform) algorithm is presented. Using the feature extraction function of SIFT, the rotation angle of rotated object in medical images is calculated as follows. First, keypoints of both reference and rotated medical images are extracted by SIFT. Second, the matching process is performed to the keypoints located at the predetermined ROI(Region Of Interest) at which objects are not cropped or added by rotating the image. Finally, degrees of matched keypoints are calculated and the rotation angle of the rotated object is determined by averaging the difference of the degrees. The simulation results show that the proposed scheme has excellent performance for correcting the rotated region in medical images.