• 제목/요약/키워드: rotation closure

검색결과 48건 처리시간 0.025초

2차 모멘트 난류모형에 의한 회전하는 평행 평판유동 해석 (Numerical Simulation of Rotating Channel Flows Using a Second Moment Turbulence Closure)

  • 신종근;최영돈
    • 대한기계학회논문집B
    • /
    • 제24권4호
    • /
    • pp.578-588
    • /
    • 2000
  • A low-Reynolds-number second moment turbulence closure is improved with the aid of DNS data. For the model coefficients of pressure-strain terms, we adopted Shima's model with some modification. Shin and Choi's new dissipation-rate equation is employed to simulate accurately the turbulence energy dissipation rate distribution in the near wall sublayer. The results of computations are compared with DNS, LES data and experimental data for turbulent plane channel flow with rotation about spanwise axis. The present second moment closure achieves a level of agreement similar to that for the non-rotating. In particular, it accurately captures the distribution of turbulence energy dissipation rate in the near wall region.

개에서 척골의 원위 성장판 조기 폐쇄증에 대한 방사선학적 평가 (Diagnostic Radiography of Premature Closure of Distal Growth Plate of Ulna in a Dog)

  • 송경진;이희천;이기창;권정국;최민철
    • 한국임상수의학회지
    • /
    • 제20권3호
    • /
    • pp.403-405
    • /
    • 2003
  • A 11 month-old Shihtzu was referred to the Veterinary Medical Teaching Hospital, Seoul National University. Clinical signs of this patient were lameness, shortening limb, angular deformity, rotation of foot, subluxaion of elbow joint and restricted range of movement of left forelimb. For the evaluation of the abnormalities of left forelimb, radiographic examination was carried out. Radiographic findings were characteristics of premature closure of distal ulna such as closure of distal ulna growth plate and cranial bowing of radius. With radiographic signs and physical examination, it was diagnosed as premature closure of growth plate of the left forelimb. After osteotomy of the radius and ostectomy of the ulna, radiographic evaluation of limb about angulation of elbow joint was performed every 2-3 weeks for 3 months. In case of premature closure of distal growth plate of ulna, radiography was very useful for diagnositic method of premature closure of distal ulna and monitoring of healing process.

Forehead reconstruction using modified double-opposing rotation-advancement flaps for severe skin necrosis after filler injection

  • Kim, Jinwoo;Hwang, Woosuk
    • 대한두개안면성형외과학회지
    • /
    • 제19권1호
    • /
    • pp.64-67
    • /
    • 2018
  • Varying degrees of complications can occur after hyaluronic acid filler injections. Tissue necrosis due to interruption of the vascular supply is an early complication that can be severe. If the site of tissue necrosis due to the filler injection is the forehead, successfully reconstructing the region without distorting the key landmarks is challenging. We describe the case of a 50-year-old man who experienced widespread forehead skin necrosis after hyaluronic acid filler injection in the glabellar area. We successfully covered the forehead area with a $3{\times}4-cm^2$ midline necrotic tissue using the modified double-opposing rotation-advancement flap method. Although modified double-opposing rotation-advancement flap closure has the disadvantage of leaving a longer scar compared to conventional double-opposing rotation-advancement flap closure, the additional incision line made along the superior border of the eyebrow aids in camouflaging the scar and decreases eyebrow distortion. Therefore, it is believed that the modified double-opposing rotation-advancement flap technique is an excellent tool for providing adequate soft tissue coverage and minimal free margin distortion when reconstructing widespread skin necrosis in the central mid-lower forehead that can occur after filler injection in the glabellar area.

압하율에 따른 기공압착 거동에 관한 실험적 연구 (An Experimental Study on Void Closure Behavior with respect to Reductions in Height)

  • 최익준;최호준;박훈재;최석우;정택우;박동규;최성규;임성주
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.114-117
    • /
    • 2009
  • In this work, closing behavior of the voids generated in a casting process was investigated for various parameters such as reductions in height void size and billet rotation during hot open die forging process. The reduction in height and path schedule including the number of paths and billet rotation were chosen as key process variables to express the change of geometrical void shape and void closing behavior. On the other hand, values of die overlapping and die width ratio were set to be constant. Extend of void closure was observed and evaluated using tensile test and microscope. Based on the experimental result, it is ensured that void closure do not occur at 15% and 30% reduction in height as well as one or two rotations of a billet. The useful datum obtained from this study could be utilized to establish an optimum path schedule in the open die forging process.

  • PDF

기공닫힘부 폐쇄정도 결정을 위한 평가방법 연구 (Evaluation methods for Void Closing Behavior in Large Ingot)

  • 최익준;최호준;윤덕재;이근안;임성주
    • 소성∙가공
    • /
    • 제20권5호
    • /
    • pp.339-343
    • /
    • 2011
  • This paper presents methods for analyzing the extent of cylindrical-shaped void closure. In addition, a quantitative relationship between change in void fraction and height reduction ratio of a compressed specimen is proposed. The height reduction ratio, number of deformation steps and billet rotation were chosen as key process parameters influencing the void closing behavior, namely, the changes in void shape and size during hot open die forging of a large ingot. The extent of void closure was analyzed from microscopic observations and estimated from tensile test results. The tensile strengths of specimens with closed voids and those without were compared for various reduction ratios in height. The results confirmed that void closure occurs at reduction ratios greater than 30 %. The void closing behavior could be expressed as a hyperbolic tangent function of reduction ratio in height, number of paths, and billet rotation. The knowledge presented in this paper could be helpful for optimizing deformation paths in open die forging processes.

위상회전에 의한 필기체 한글의 자동인식 (Automatic Recognition of Hand-written Hangout by the Phase Rotation)

  • 이주근;김홍기
    • 대한전자공학회논문지
    • /
    • 제13권1호
    • /
    • pp.23-30
    • /
    • 1976
  • 이 논문에서는 위상회전에 의한 오목구조의 짐출로서 필기체 한글을 인식하는 한 방법을 검토한다. 문자 Pattern를 오목구조적인 기본 Segment로 분해하여 집합으로 분류하고, 그들 집함에 대한 각 Segment의 폐상태와 위상특징을 logic으로 표현한다. 다음 그들 logic pattern의 위상회전으로서 오목구조의 topological성질과 위상특징을 검출하여 문자를 결정한다. 이 방법은 필기체의 변화와 문자의 대소, 경사 띤 위치 변위에 대한 식별의 유연성을 가지며, 인식율이 높다. In this paper, a method is proposed for the recognition of hand-written Hangeul. This is peiformed by extraction of the concave structural segments by phase rotation. Character patterns can be decomposed into the fundamental concave structural segments which are also categorized into segment sects, and the closure and phase features of each segment in set is represented by logics. By rotating the logic pattern, the topological and phase features of segment are extracted for the reliable recognition of the character. It is also evaluated that this method applies to a wide variety of shape, position and declination of the character.

  • PDF

난치성 사마귀의 수술적 치료 (Surgical Treatment of Recalcitrant Wart)

  • 김가람;최재구;허지연;고장휴;서동국;이종욱;장영철
    • Archives of Plastic Surgery
    • /
    • 제38권6호
    • /
    • pp.798-802
    • /
    • 2011
  • Purpose: A wart is caused by epidermal infection with the human papilloma virus. Although wart naturally disappears in some cases, it require treatment because of pain, aesthetic problem, and the possibility of malignant change. Conventional non-surgical treatment cannot be a fundamental solution for the pain and has such disadvantages as frequent recurrence and difficulties in achieving a satisfactory outcome. A surgical procedure was performed on patients with wart and the procedure had a good outcome. Methods: We investigated the gender, age, lesion site, mean treatment duration, and presence or absence of recurrence in 21 patients with a wart within the period of January 2007 to July 2011. For local lesions, primary closure, including subcuticular suture after the excision, was performed. If the defect size was too big to do primary closure, we performed rotation flap. For wide multiple lesions, a split thickness skin graft was performed. Results: Among the 21 patients, 12 patients were male and 9 patients were female, and their mean age was 42 years (SD=17.38, range: 11~75 years). The lesion site was the foot in 10 patients, the hand in 8 patients, the face in 2 patients, and the scalp in 1 patient. The mean treatment duration was 13.5 days (SD=4.36, range: 6~15 days) for the primary closure or rotation flap, and 18.5 days (SD=2.12, range: 17~20 days) for the skin graft. 20 patients were cured without recurrence. No recurrence was observed in the patients who underwent primary closure or rotation flap. One of the two patients who underwent a skin graft of their wart that had covered their entire palm had local recurrence in part of her finger tips. Conclusion: We performed surgical procedure on recalcitrant wart. As a results, we can treat it with short treatment duration, low recurrence rate and less scarring and get high patient satisfaction.

광섬유전송에 의한 Zircaloy-4 봉단마개밀봉의 Nd:YAG LBW의 최적조건에 관한 연구 (A study on the Optimum Conditions of Nd:YAG LBW for Zircaloy-4 End Cap Closure By Optical Fiber Transmission)

  • 김수성;김웅기;이영호
    • Journal of Welding and Joining
    • /
    • 제15권6호
    • /
    • pp.85-95
    • /
    • 1997
  • This study is to investigate the optimum conditions of Nd:YAG laser beam welding for Zircaloy-4 end cap closure by optical fiber transmission. Laser welding parameters which affect the penetration depth and bead width were experimentally examined using the various beam radius by the beam quality analyzer, joint geometries of end cap and the laser parameters which mean pulse width, repetition rate and pulse energy. Also, an optimum welding speed and the effect of assistant gas with varying the flow rate of He were investigated. We found that the laser average power for the end cap welding will be 230W and rotation speed must not exceed 8 RPM, the best position of focus using optical fiber with 600.mu.m will be 2 to 3mm below the surface of the material.

  • PDF

Reconstruction of a large chest wall defect using bilateral pectoralis major myocutaneous flaps and V-Y rotation advancement flaps: a case report

  • Jo, Gang Yeon;Yoon, Jin Myung;Ki, Sae Hwi
    • Archives of Plastic Surgery
    • /
    • 제49권1호
    • /
    • pp.39-42
    • /
    • 2022
  • Bilateral pectoralis major myocutaneous (PMMC) flaps are commonly used to reconstruct large chest wall defects. We report a case of large chest wall defect reconstruction using bilateral PMMC flaps augmented with axillary V-Y advancement rotation flaps for additional flap advancement. A 74-year-old male patient was operated on for recurrent glottic squamous cell carcinoma. Excision of the tumor resulted in a 10×10 cm defect in the anterior chest wall. Bilateral PMMC flaps were raised to cover the chest wall defect. For further flap advancement, V-Y rotation advancement flaps from both axillae were added to allow complete closure. All flaps survived completely, and postoperative shoulder abduction was not limited (100° on the right side and 92° on the left). Age-related skin redundancy in the axillae enabled the use of V-Y rotation advancement flaps without limitation of shoulder motion. Bilateral PMMC advancement flaps and the additional use of V-Y rotation advancement flaps from both axillae may be a useful reconstructive option for very large chest wall defects in older patients.

En-masse 견인에 의한 발치공간 폐쇄 후 상악치열의 이동양상 -제1소구치 및 제2소구치 발치 비교 (Spatial changes of the upper dentition following en-masse space closure: A comparison between first and second premolar extraction)

  • 김희정;전윤식;정상혁
    • 대한치과교정학회지
    • /
    • 제35권5호
    • /
    • pp.371-380
    • /
    • 2005
  • 제1소구치 또는 제2소구치 발치 후 발치공간 폐쇄 시 치아이동의 양상 즉, 치아이동방향과 이동량을 구명하는 것이 본 연구의 목적이었다. 상악 우측 인공 치조골부에 제1소구치 또는 제2소구치를 제외한 중절치부터 제2대구치 까지 실험용 치아들을 식립하고 bull loop이 형성된 반쪽 호선에 15도의 gable bend를 부여한 후 전치부를 후방견인하여 발츠공간을 폐쇄시켰다. 실험 전후에 교합면 방사선사진과 시상면 방사선사진을 촬영하고 인공치조골부 하단에 식립된 기준표지점에 중첩하여 이동방향 및 이동량을 계측하였다. 그 결과 제2소구치 발치군의 전치부후방이동량이 제1소구치 발치군에 비해 더 적었으며 구치부의 고정원 소실 및 고정원의 근심설측회전량은 제2소구치 발치군에서 더 크게 나타났다.