• Title/Summary/Keyword: rotary function

Search Result 103, Processing Time 0.022 seconds

A Study of Structural Stability and Dynamics for Functionally Graded Material Plates and Shells using a 4-node Quasi-conforming Shell Element (4절점 준적합 쉘 요소를 이용한 점진기능재료(FGM) 판과 쉘의 구조적 안정 및 진동 연구)

  • Han, Sung-Cheon;Lee, Chang-Soo;Kim, Gi-Dong;Park, Weon-Tae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.5
    • /
    • pp.47-60
    • /
    • 2007
  • In this paper, we investigate the natural frequencies and buckling loads of functionally graded material (FGM) plates and shells, using a quasi-conforming shell element that accounts for the transverse shear strains and rotary inertia. The eigenvalue of the FGM plates and shells are calculated by varying the volume fraction of the ceramic and metallic constituents using a sigmoid function, but their Poisson's ratios of the FGM plates and shells are assumed to be constant. The expressions of the membrane, bending and shear stiffness of FGM shell element are more complicated combination of material properties than a homogeneous element. In order to validate the finite element numerical solutions, the Navier's solutions of rectangular plates based on the first-order shear deformation theory are presented. The present numerical solutions of composite and sigmoid FGM (S-FGM) plates are proved by the Navier's solutionsand various examples of composite and FGM structures are presented. The present results are in good agreement with the Navier's theoretical solutions.

Resin Bond Strength of Lithium Disilicate Glass-Ceramic by Surface Cleansing Method after Temporary Cementation (임시접착 후, 치면세마에 따른 Lithium Disilicate Glass-Ceramic의 레진결합강도에 대한 연구)

  • Chung, Seung-Hwa;Lee, Jin-Han;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.3
    • /
    • pp.259-268
    • /
    • 2007
  • purpose: This study was to evaluate the shear bond strength of Lithium Disilicate Glass-Ceramic by removable method of temporary cement on the abutment tooth. Material and Method: Sixty molar teeth of human with the occlusal surface up were mounted in acrylic resin blocks. The 45 specimens were prepared to exposure dentin by diamond bur and the eugenol-containing temporary cement($Cavitec^{TM}$ ($KERR^{(R)}$, U.S.A)was applied to the dentin surfaces. After initial removal of the cement with a dental explorer, the specimens were divided into 4 groups of 15 specimens each. The dentin surfaces of the specimens were treated by rotary instrument with as follow pastes: $Zircate^{(R)}$ prophy paste(Dentsply, U.S.A), Radent Prophy Paste(Pascal company,inc. U.S.A), and Dental pumice(Wip mix corporation,U.S.A). An adhesive resin luting agent(Variolink $II^{(R)}$, Ivoclar Vivadent, Leichtenstein) including Monobond-S and $Excite^{(R)}$ was applied to all specimens. The ceramic specimens were made with an A1 ingot of IPS Empress $II^{(R)}$ (Ivoclar Vivadent, Leichtenstein). After the specimens were stored in distilled water for 48hr, the shear bond strength(MPa) was measured by a Universal testing machine(Zwick 145641, Zwick, Germany) at a 1mm/min cross-head speed. The data were statistically analyzed by one-way ANOVA and Duncan's multiple range test. Results: In all group, there were no significant differences in comparison with the control group(p>0.05). The pattern of most failure showed the mixed type of cohesive and adhesive failure. Conclusion: Resin bond strength of IPS Empress $II^{(R)}$ was not affected by removal method of the temporary cement.

Accuracy Simulation of Precision Rotary Motion Systems (회전운동 시스템의 정밀도 시뮬레이션 기술)

  • Hwang, Joo-Ho;Shim, Jong-Youp;Hong, Seong-Wook;Lee, Deug-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.3
    • /
    • pp.285-291
    • /
    • 2011
  • The error motion of a machine tool spindle directly affects the surface errors of machined parts. The error motions of the spindle are not desired errors in the three linear direction motions and two rotating motions. Those are usually due to the imperfect of bearings, stiffness of spindle, assembly errors, external force or unbalance of rotors. The error motions of the spindle have been needed to be decreased to desired goal of spindle's performance. The level of error motion is needed to be estimated during the design and assembly process of the spindle. In this paper, the estimation method for the five degree of freedom (5 D.O.F) error motions of the spindle is suggested. To estimate the error motions of the spindle, waviness of shaft and bearings, external force model was used as input data. And, the estimation models are considering geometric relationship and force equilibrium of the five degree of the freedom. To calculate error motions of the spindle, not only imperfection of the shaft, bearings, such as rolling element bearing, hydrostatic bearing, and aerostatic bearing, but also driving elements such as worm, pulley, and direct driving motor systems, were considered.

The Performance Evaluation of the Exhaust Stack used in High Riser Public House (초고층 공동주택 국소배기용 입상덕트의 배기성능평가)

  • Kwon, Yong-Il;Kim, Ung-Yong;Shin, Hyun-Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.3
    • /
    • pp.60-67
    • /
    • 2014
  • Exhaust system used in toilet and cooking place of high riser public house is roof fan of two basic types : natural roof ventilator and natural/forced roof ventilator. Natural/forced roof ventilator has a motor in the rotary shaft. There are many high riser public house in Korea. These buildings were not viewed as being major contributors to exhaust pollutants producted in indoor. It was because many engineers thought that exhaust in high riser building depend on stack effect. This study investigates on stack pressure determined by exterior pressure and the difference pressure control in exhaust stack used in high riser public house. This paper focuses mainly on the effect of the time interval for power supply of motor installed in roof fan with function of natural wind velocity and of exhaust air volume of toilet. It is observed there are higher exhaust efficiency than the existing natural roof ventilator.

Design and testing of the KC-100 Spin Recovery Parachute System (SRPS)

  • Lee, Dong-Hun;Nho, Byung-Chan;Kang, Myung-Kag;Kang, Kyung-Woo;Lee, Ju-Ha;Kim, Su-Min;Kwon, Young-Suk
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.1
    • /
    • pp.117-125
    • /
    • 2012
  • This paper presented the design of SRPS, ground function test, and the deployment test on a high speed taxi of KC-100 airplane. KAI has developed a spin recovery system in collaboration with Airborne Systems for KC-100 general aviation airplane. Spin mode analysis, rotary balance and forced oscillation tests were performed to obtain the rotational, dynamic derivatives in the preliminary design phase. Prior to the detailed design process of SRPS, approximations for initial estimation of design parameters- fineness ratio, parachute porosity, parachute canopy filling time, and deployment method- were considered. They were done based on the analytical disciplines such as aerodynamics, structures, and stability & control. SRPS consists of parachute, tractor rocket assembly for deployment, attach release mechanism (ARM) and cockpit control system. Before the installation of SRPS in KC-100 airplane, all the control functions of this system were demonstrated by using SBTB(System Breakout Test Box) in the laboratory. SBTB was used to confirm if it can detect faults, and simulate the firing of pyrotechnic devices that control the deployment and jettison of SRPS. Once confirmed normal operation of SRPS, deployment and jettison of parachute on the high speed taxiing were performed.

DVI cable Improvement for Preventing MFD Abnormal Display of a Rotary-wing Aircraft (회전익 항공기 다기능시현기의 이상시현을 방지하기 위한 DVI 케이블 개선)

  • Kim, Young Mok;Jeong, Sang-Gyu;Cho, Jae Po;Choi, Doo-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.9
    • /
    • pp.782-789
    • /
    • 2018
  • Multi-Function Display (MFD) of Korean Utility Helicopter (KUH) displays image information(navigation, flight, topographical and maintenance information) delivered from Mission Computer (MC) during flight operation. The abnormal display of MFD such as flickering phenomenon was identified in the system development. It was solved by improving the shielding performance of the DVI cable and changing the DVI cable installation path at the first mass production. However, it was occurred again when the aircraft was operated for one or two years after delivery. It was also identified in the evaluation process of the derivative helicopters. Therefore, a comprehensive review of the aircraft system level has been performed to solve the problem of MFD malfunction at first and then a design improvement plan was derived by improving the DVI cable. In this paper, the causes of MFD anomalies are analyzed and also the process of design improvement are summarized. The validity of the improvement has been verified through the DVI cable assembly comparison test, SIL/ground/flight test.

Nozzle Flow Characteristics and Simulation of Pesticide Spraying Drone (농약 살포 드론의 노즐 유동 특성 및 시뮬레이션)

  • Kang, Ki-Jun;Chang, Se-Myong;Ra, In-Ho;Kim, Sun-Woo;Kim, Heung-Tae
    • Smart Media Journal
    • /
    • v.8 no.4
    • /
    • pp.38-45
    • /
    • 2019
  • When there is a spray flow such as from a pesticide nozzle, winds affect the droplet flow of a rotary-wing drone accompanied by a strong wake, with a severe oscillation. Especially, during forwarding flights or when winds come from the side, compare to a simple hovering flight as the droplet is in the effect of aerodynamic drag force, the effect of spraying region becomes even larger. For this reason, the spraying of pesticides using drones may cause a greater risk of scattering or a difference in droplet dispersion between locations, resulting in a decrease in efficiency. Therefore, through proper numerical modeling and its applied simulation, an indication tool is required applicable for the various flight and atmospheric conditions. In this research, we completed both experiment and numerical analysis for the strong downwash from the rotor and flight velocity of the drone by comparing the probability density function of droplet distribution to build a spraying system that can improve the efficiency when spraying droplets in the pesticide spray drone.

Crack growth behavior of fatigue surface crack initiated from a small surface defect (작은 表面缺陷에서 發생.成長하는 表面疲勞균열의 成長特性에 관한 硏究)

  • 서창민;권오헌;이정주
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.191-197
    • /
    • 1987
  • It has been well known that the fracture mechanics can be applied to large through crack growth. But the growth rate of small surface cracks initiated from a small defect under rotary bending fatigue tests can not be treated as a function of stress intensity factor range. In this paper, to investigate the growth behavior of surface small fatigue cracks in the view-point of both fracture mechanics and strength of materials, the fatigue test has been carried out on two kinds of plain carbon steels with a small surface defect. Applying the concept of the cyclic strain intensity factor range .DELTA. $K_{\epsilon}$/$_{t}$ to the analysis of small surface fatigue crack growth, it is found that the relationship between cyclic strain intensity factor range and crack growth rate shows linear relation on logarithmic coordinates regardless of defect sizes and two kinds of carbon steels.s.s.

Regenerative procedure using rotary titanium brush for surface decontamination of peri-implantitis: 3 cases with a 2-year follow-up (회전형 타이타늄 브러쉬를 이용한 임플란트 주위염 재생술식: 2년 추적결과 증례 보고)

  • Baek, Min-Woo;Yu, Jeoung-A;Choi, Seong-Ho;Lee, Dong-Woon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.4
    • /
    • pp.259-267
    • /
    • 2021
  • Peri-implantitis, in which inflammation caused by plaque and biofilm on the implant surface spreads to the hard tissue, can be treated by decontamination of the implant surface and reconstruction of the lost hard tissue through surgical methods. We have described the management of 3 peri-implantitis cases by decontamination of the implant surface using a round titanium brush and regenerative therapy. All cases showed clinical improvements, and no further radiographic bone loss was observed during a 2-year follow-up. This treatment method can be effective for clinical improvement and bone regeneration. However, a longer follow-up period is necessary to support these outcomes.

Shaping characteristics of two different motions nickel titanium file: a preliminary comparative study of surface profile and dentin chip (두 가지 다른 행정의 니켈 티타늄 파일의 성형 성상: 표면 성상, 상아질 삭편과 도말층에 대한 예비적 비교 연구)

  • Park, So-Ra;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.121-130
    • /
    • 2014
  • Purpose: To assess the surface profile of dentinal wall, dentin chips and smear layer during the canal shaping with rotary (ProTaper) and ProFile and reciprocating (WaveOne) nickel-titanium file. Materials and Methods: Sixty human extracted mandibular premolars and incisors with single canals were randomly selected. Three experimental groups (n = 20) were instrumented with ProTaper (F2), ProFile (25/.06), WaveOne (25/.08) with irrigation of 2.5% NaOCl. The dentin chips were collected from flute of file during each canal preparation. After canal preparation, roots were grinded and each group was divided into two subgroups (n = 10) for surface profile and smear layer of dentinal wall of shaped root canal. Each specimen was observed under scanning electron microscope for evaluating size of dentin chips, root canal surface recessions and smear layer. Scores of Smear layer were statistically analyzed using Kruskal Wallis test and Mann Whitney test at P = 0.05 level. Results: The size of dentin chips from ProFile, ProTaper and WaveOne was up to $7{\mu}m$, $6.5{\mu}m$, and$4{\mu}m$, respectively. In the surface profile, the width of surface irregularity was measured and Profile, ProTaper and WaveOne was up to $150{\mu}m$, $70{\mu}m$, and $80{\mu}m$, respectively. Completely cleaned root canals were not found. In the middle and apical third of the canals, WaveOne group showed higher smear layer score than ProFile and ProTaper groups (P < 0.05). Conclusion: Within limits of this study, reciprocating motion WaveOne group was not significant difference of shaping ability with the full-sequence ProFile and ProTaper systems except canal clearness of middle and apical third of root canal. When using WaveOne to shaping root canal, thorough root canal irrigation is recommended.