• 제목/요약/키워드: room strain

검색결과 422건 처리시간 0.026초

고온초전도 PIT선재의 반복 열응력 및 변형률 의존성 (Dependence of thermal cycling and axial strain on HTS PIT tapes)

  • 하홍수;이동훈;최정규;양주생;황선역;김상철;하동우;오상수;권영길
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.131-133
    • /
    • 2003
  • The effect of axial strain and thermal cycling on the critical current is investigated for the Bi-2223/Ag PIT tapes. The axial strain was applied to the tapes by the U-shape sample holder. Two kinds of Bi-2223/Ag tapes with different Ag sheath are used to know the effect of sheath alloying for the tensile strain. The influence of thermal cycling between room temperature and 77 K on critical current are examined. Critical current is drastically decreased for Ag/alloy and Ag/alloy/alloy sheathed tapes at tensile strain above 0.22% and 0.3%, respectively.

  • PDF

인장 및 압축실험을 통한 마그네슘 합금의 고온 물성 평가 (Estimation of Mechanical Properties of Mg Alloy at High Temperature by Tension and Compression Tests)

  • 오세웅;추동균;이준희;강충길
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2005
  • The crystal structure of magnesium is hexagonal close-packed (HCP), so its formability is poor at room temperature. But formability is improved in high temperature with increasing of the slip planes. Purpose of this paper is to know about the mechanical properties of magnesium alloy (AZ31B), before warm and hot forming process. The mechanical properties were defined by the tension and compression tests in various temperature and strain-rate. As the temperature is increased, yield${\cdot}$ultimate strength, K-value, work hardening exponent (n) and anisotropy factor (R) are decreased. But strain rate sensitivity (m) is increased. As strain-rate increased, yield${\cdot}$ultimate strength, K-value, and work hardening exponent (n) are increased. Also, microstructures of grains fine away at high strain-rate. These results will be used in simulations and manufacturing factor for warm and hot forming process.

  • PDF

22Cr 마이크로 듀플렉스 스테인리스강의 변형유기마르텐사이트에 미치는 Ni과 Mn의 영향 (Effect of Ni and Mn on Strain Induced Martensite Behavior of 22Cr Micro-Duplex Stainless steel)

  • 박준영;김기엽;안용식
    • 동력기계공학회지
    • /
    • 제17권6호
    • /
    • pp.122-129
    • /
    • 2013
  • The microstructure and deformation behavior in 22Cr-0.2N micro-duplex stainless steels with various Ni and Mn contents were compared using by OM, TEM, and XRD. The 22Cr-0.2N duplex stainless steel plates were fabricated and hot rolled, followed by annealing treatment at the temperature range of $1,000-1,100^{\circ}C$. All the samples showed the common strain hardening behaviour during the tensile test at a room temperature. The steels tested at the temperatures of $-30^{\circ}C$ or $-50^{\circ}C$ showed a distinct inflection point in the stress-strain curves, which should be resulted from the formation of strain-induced martensite(SIM) of austenite phase. This was confirmed by TEM observations. The onset strain of a inflection point in a stress-strain curve should be depended up the value of $M_d30$. With the decrease of the tensile test temperature, the inflection point appeared earlier, and the strength and fracture strain were higher. The tensile behaviour was discussed from the point of austenite stability of the micro-duplex stainless steels with the different Ni and Mn content.

강 용접 열영향부 놋치 선단 의 소성 스트레인 평가에 관한 연구 (A Study on Evaluation of Plastic Strain at Notch Tip of Weld HAZ in Steel)

  • 김태영;임재규;정세희
    • Journal of Welding and Joining
    • /
    • 제2권1호
    • /
    • pp.41-48
    • /
    • 1984
  • Recrystallization technique was applied to analyze plastic strain at the notch tip of coarse grain HAZ in mild steel (SB 41) and high strength steel (SA 588). The notch tip of specimen was deformed by three point bending. Accumulated displacement (Crack Opening Displacement ${delta}t$) by the monotonic and cyclic loading under room temperature and hot strain embrittlement temperature ($250^{\circ}C$) was 0~1.0mm. Recrystallization heat treatment conditions were $650^{circ}C{ imes}3hr$ for SB 41 and $700^{circ}C{ imes}3hr$ for SA 588. The experimental results obtained were as follows ; 1) Distribution of the effective plastic strain at plastic zone was appeared by the function of crack opening displacement, and plastic zone or the effective plastic strain increased with crack opening displacement. 2) Plastic strain at notch tip of HAZ due to accumulated hot strain calculated as follows. .epsilon. over bar $_{p}$ = .epsilon. over bar $_{cr}$ (x/ $R_{x}$ ) $^{m}$ (m=0.25) 3) Work hardending ratio of notch tip for hot strain was linearly increased with .epsilon. over bar $_{max}$ and dependent upon the material types.s.

  • PDF

신재 및 가동이력 Gr.91강의 재료강도 거동에 미치는 동적변형시효의 영향 (Influence of dynamic strain aging on material strength behavior of virgin and service-exposed Gr.91 Steel)

  • 남기언;이형연;어재혁;김형모;홍현욱
    • 한국압력기기공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.66-74
    • /
    • 2024
  • This study investigates the effects of temperatures and strain rates on the strength and ductility of Gr.91 (ASME Grade 91) steel which is widely being used as a heat-resistant material in Generation IV nuclear and super critical thermal power plants. The tensile behavior of modified 9Cr-1Mo (Gr.91) steel was studied for the three strain rates of 6.67×10-5/s, 6.67×10-4/s and 6.67×10-3/s over the temperature range from room temperature (RT) to 650℃. Experimental results showed that at specific combinations of temperatures (300~400℃) and strain rates, serrations appeared in the stress-strain curves. Concurrently, abnormal behaviors such as a plateau in yield strength and tensile strength, a minimum in ductility and negative strain rate sensitivity were observed. These phenomena were analyzed as significant characteristics of dynamic strain aging (DSA). Since this abnormal behavior in Gr.91 steel affects the material strength, it is judged that a correlation analysis between DSA and material strength should be crucial in the design and integrity evaluation of Gr. 91 steel pressure vessel and piping subjected to high-temperature loading.

병실 낙하균 및 산모감염에 관한 연구 (A Study on the Air Counts and the Infection of Maternity in n General Hospital)

  • 이남희
    • 대한간호학회지
    • /
    • 제9권2호
    • /
    • pp.17-26
    • /
    • 1979
  • This research is to prevent the infection of maternity in the hospital by examining the microbes contaminations in maternity through airbone microbes and those who are engaged in the ward of O.B. & G.Y. and to furnish the basic data available to hospital management. The bacterial growth of airbone microbes contaminations in nosocomial air and who thor the nasal cavity of passers by (doctors, nurses, parturient women) who went to the ward of O.B. & G.Y. contaminated or not were examined in“E”Univ. Hospital from July to August, 1979 by using thioglycollate broths and agar plates. The following results were obtained: 1. The average colony number of airborne microbes revealed as follows the pediatric ward (36 colonies), the internal ward (33 colonies), the ward of O.B. & G.Y. (30 colonies), the ward of surgery (24 colonies), delivery-waiting room (11 colonies), and the delivery room (3 colonies). 2. The bacterial growth beforenoon differed from that of afternoon. Namely, the latter (24 colonies) was higher than the former (21 colonies). 3. The type of strains isolated from the air of the ward revealed staphylococci (82%), Gram negative bacilli (18%), fungi (17%), Gram positive diplococci (13%), and Bacillus subtilis (2.8%). 4. The strains isolated in the delivery-waiting room revealed staphylococci (66.7%), Gram negative bacilli (33.6%), and revealed staphylococci (75%), Gram positive diplococci (8.3%), and fungi (8.3%), in delivery room. 5. Most of strains isolated in the ward of O.B. & G.Y. revealed staphylococci (100.0%), Gram positive diplococci (8.3%), and Gram negative bacilli (6.7%). 6. The strain isolated in the surgical ward revealed staphylococci (91.7%), fungi (33.3%), Gram positive diplococci (25%), Gram negative bacilli (25%) and Bacillus subtilis (8.3%). 7. The strain isolated in the pediatric ward revealed staphylococci (75%), fungi (25%), Gram positive diplococci (8.3%), Bacillus subtilis (8.3%), and Gram negative bacilli (8.3%). 8. The strain isolated in the internal ward revealed staphylococci (91.7%), fungi (33.3%), Gram positive diplococci (25%), and negative bacilli (16.7%). The strains isolated from the nasal cavity of those doctors and nurses who and enaged in the ward of O.B. & G.Y. revealed staphylococci (80%), Bacillus subtilis (10%), and Gram negative bacilli (10%), from doctors and Gram positive diplococci (10%), instead of Gram negative bacilli (10%), from nurses. 10. The strain isolated from nasal cavity of parturient women on admission revealed staphylococci (90%), and Gram negative bacilli (10%), but after admission revealed staphylococci (70%), Gram positive diplococci (10%), and Gram negative bacilli (10%). 11. Of the total 91 staphylococci isolated from the air of the ward, the Coagulase pastive was 36 (39.6%), and the negative 55 (60.4%), As a result of the coagulase experiment of the staphylococci isolated from the nasal cavity of those who are engaged in the ward of O.B. & G.Y. all were revealed as negative that belonged to non-pathogenic. 12. Consequence of the biochemic examination of the gram negative bacilli isolated from the air of the ward the aerobacter aerogens revealed was (16.7%) E-coli 5% in the nasal cavity of those came and went to the of O.B. & G.Y. and Aerobacter aerogens 7.5%.

  • PDF

변형가시화법을 이용한 열간 축대칭 평금형 압출의 실험적 해석 (An Experimental Analysis for Axisymetric Hot Extrusion Through Square Dies Using Visioplasticity Method)

  • 엄태복;한철호
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1995년도 춘계학술대회논문집
    • /
    • pp.107-113
    • /
    • 1995
  • To investigate the behavior of platic deformation inaxisymmetric hot extrusion through square dies, the physical modelling with the plasticine as a model material is carried out at the room temperature. Some mechanical properties of the model material are determined by compression and ring compression tests. Visioplasticity method using experimetal grid distortion is introduced to anlayze the plastic flow, strain rate and strain distribution.

  • PDF

폴리아세탈 소재의 확률론적 변형률-수명선도 평가 (An Evaluation of Probabilistic Strain-Life Curve in Polyacetal)

  • 장천수;김철수;박범규;김정규
    • 대한기계학회논문집A
    • /
    • 제30권11호
    • /
    • pp.1417-1424
    • /
    • 2006
  • In order to evaluate variation of fatigue life of mechanical components including engineering plastics, it is important to estimate probabilistic strain-life curves to accurately define the variation of fatigue characteristics. This paper intends to provide new assessment of P-$\varepsilon$-N (probabilistic strain-life curves) for considering the variation of fatigue characteristics in polyacetal. The fatigue strain controlled tests were conducted under constant 50% humidity and room temperature condition by a universal testing machine at strain ratio, R=0. A practical procedure is introduced to evaluate probabilistic strain-life curves. Three probabilistic distributions were used for generating P-$\varepsilon$-N curves such as normal, 2-parameter and 3-parameter Weibull. In this study, 3-parameter Weibull distribution was found to be most appropriate among assumed distributions when the probability distributions of the fatigue characteristic were examined using chi-square and Kolmogorov-Smirnov test. The more appropriate P-$\varepsilon$-N curves for these materials are generated by the proposed method considering 3-parameter Weibull distribution.

마그네슘의 진동감쇠능에 미치는 냉각 속도의 영향 (Effect of Cooling Rate on Damping Capacity of Magnesium)

  • 전중환
    • 열처리공학회지
    • /
    • 제30권6호
    • /
    • pp.258-263
    • /
    • 2017
  • The effect of cooling rate on the damping capacity of pure Mg was studied. Two Mg samples with different cooling rates were prepared by heat treatment at 873 K for 24 h, followed by water quenching and by furnace cooling to room temperature, respectively. The average grain sizes of the Mg samples were almost identical regardless of the cooling rate, but more twins were observed in the sample with faster cooling rate. The calculated vacancy fraction was higher in the fast cooling sample than the slow cooling one. It is noted that the fast cooling sample exhibited lower damping capacity both in the strain-amplitude independent and strain-amplitude dependent regions. Higher values of vacancy concentration and number density of twins in the fast cooling sample are considered to be responsible for the deteriorated damping capacity in the strain-amplitude independent and strain-amplitude dependent regions, respectively.

리브-웨브형 정밀단조에 관한 상계요소해석 (UBET Analysis on Precision Rib-Web Forgings)

  • 이종헌;김영호;배원병
    • 대한기계학회논문집
    • /
    • 제19권5호
    • /
    • pp.1211-1219
    • /
    • 1995
  • An upper bound elemental technique (UBET) program has been developed to analyze forging load, die-cavity filling and effective strain distribution for flash and flashless forgings. The simulation for flash and flashless forgings are applied axisy mmetric and plane-strain closed-die forging with rib-web type cavity. Inverse triangular and inverse trapezoidal elements are used to analyze flashless forging. The analysis is described for merit of flashless precision forging. Experiments have been carried out with pure plasticine billets at room temperature. Theoretical predictions of the forging load and the flow pattern are in good agreement with experimental results.