• 제목/요약/키워드: roof surface

검색결과 270건 처리시간 0.027초

아치형 단동온실의 최적설계를 위한 풍력계수분포도의 분석 (An Analysis of Wind Force Coefficient Distributions for Optimum Design of Single-Span Arched Greenhouse)

  • 이석건;이현우;권무남
    • 생물환경조절학회지
    • /
    • 제4권1호
    • /
    • pp.1-8
    • /
    • 1995
  • One of the most destructive forces around greenhouses is wind. Wind loads can be obtained by multiplying velocity pressure by dimensionless wind force coefficient. Generally, wind force coefficients can be determined by wind tunnel experiments. The wind force coefficient distribution on a single - span arched greenhouse was estimated using experimental data and compared with reported values from various countries. The results obtained are as follows : 1. The coefficients obtained from this study agree with the values proposed by G. L. Nelson except about 0.5 of difference in the middle region of roof section. This discrepancy is mainly attributed to the dissimilarity of experimental conditions (or wind tunnel test such as Reynolds number, type of terrain, surface roughness of model, location of the lapping and measuring methods. 2. Considering that the wind force coefficients are varied along the height of a wall at wind direction perpendicular to wall, structural analysis using subdivided wind force coefficient distribution is more resonable for wall. 3. It is recommendable that wind force coefficient distribution on a roof should take more subdivision than the existing four equal divisions for more accurate structural design. 4. Structural design using wind forces close to real values is more advantageous in safety and expense.

  • PDF

Effects of Experimental Drought on Soil CO2 Efflux in a Larix Kaempferi Stand

  • Kim, Beomjeong;Yun, Youngjo;Choi, Byoungkoo
    • Journal of Forest and Environmental Science
    • /
    • 제34권3호
    • /
    • pp.253-257
    • /
    • 2018
  • Climate models forecast more frequent and a longer period of drought events which may impact forest soil carbon dynamics, thereby altering the soil respiration (SR) rate. We examine the simulated drought effects on soil $CO_2$ effluxes from soil surface partitioning heterotrophic and autotrophic soil respiration sources. Three replicates of drought plots ($6{\times}6m$) were constructed with the same size of three control plots. We examined the relation between $CO_2$ and soil temperature and soil moisture, each being measured at a soil depth of 15 cm. We also compared which factor affected $CO_2$ efflux more under drought conditions. Total SR, autotrophic respiration (AR) and heterotrophic respiration (HR) were positively correlated with soil temperature (p < 0.05), and the relationships were stronger in roof plots than in control plots. Total SR, AR, and HR were negatively correlated only in roof plots, and the only HR showed a significant correlation (p < 0.05, r = -0.59). Soil respiration rates were more influenced by soil temperature than by soil moisture, and this relationship was more evident under drought conditions.

지붕 설치형 결정질 실리콘 태양전지모듈의 온도 특성 (Roof-attached Crystalline Silicon Photovoltaic Module's Thermal Characteristics)

  • 김경수;강기환;유권종;윤순길
    • 한국태양에너지학회 논문집
    • /
    • 제32권3호
    • /
    • pp.11-18
    • /
    • 2012
  • To expect accurately the maximum power of solar cell module under various installation conditions, it is required to know the performance characteristics like temperature dependence. Today, the PV (photovoltaic) market in Korea has been growing. Also BIPV (building integrated photovoltaic) systems are diversified and become popular. But thermal dependence of PV module is little known to customers and system installers. In IEC 61215,a regulation for testing the crystalline silicon solar cell module, the testing method is specified for modules. However there is limitation for testing the module with diverse application examples. In extreme installation method, there is no air flow between rear side of module and ambient, and it can induce temperature increase. In this paper, we studied the roof type installation of PV module on the surface of one-axis tracker system. We measured temperature on every component of PV module and compared to open-rack structure. As a result, we provide the foundation that explains temperature characteristics and NOCT (nominal operation cell temperature) difference. The detail description will be specified as the following paper.

바로셀로나 파빌리온의 구축적 공간 특성에 관한 연구 (A Study on the Spatial Characteristics in the Tectonic of the Barcelona Pavilion)

  • 양재혁
    • 한국실내디자인학회논문집
    • /
    • 제33호
    • /
    • pp.19-26
    • /
    • 2002
  • This study analyzed the characteristics of spatial expression in the Barcelona Pavilion to be based on tectonics. Mies pointed out the image of materiality about the material rather than the process of tectonics using the material, and he also expressed demateriality in the image of each material through the reflection. To be liberated from structural matters, the wall has been introduced. He intended to show the design plan as the independent structural system, however, the wall actually seems to be supporting the roof that shows rather clearly self-contradictory because of the expression of materiality in the material. In terms of architectural elements; wall, roof, column, floor, and so forth, tectonic expression and abstract aesthetics stands face to face, because of hiding the productional process and transforming to line and surface in the image of materiality. The interior of the glass wall seems fairly closed space from the exterior, because materiality and reflection of materials of columns and podium. The character of experiential space is inconsistent and fragmentary because of the splendid images from maternality and reflection on the wall, and collision with the reality and the image the wall reflects, even though the geometrical space of the Pavilion's plan has the mutual penetrability and organic character.

Present State of Membrane Structures in Japan

  • Oda, Kenshi
    • 한국공간구조학회지
    • /
    • 제2권2호
    • /
    • pp.11-15
    • /
    • 2002
  • Formerly, it was called a tent and now, it is called membrane structure. If saying a tent, it imagines the tent of Bedouin, Mongolia and North American Indian. It became clear from the excavated wall painting that have been covered with the retractable roof of the canvas on the auditorium at the amphitheater in Pompeii and became a topic. These tents were made of the animal skins or fabric woven with the flax plants, and these tents are still used. However, if saying membrane material at present, it says the one to have applied a coating resin to the textile. Because the base fabric of membrane material is a woven fabric, the relation between the stress and the strain is different to the direction of the weaving thread. Moreover, the tensile force must always occur in the membrane surface. From these reasons, because the membrane structure corresponds to the particular building material and the construction method about the Building Standard Law, it must be examined specially that the membrane structural building have the same or any more safety as the provisions which was set to the Building Standard Law. Therefore, the technical standards about the membrane structural building became indispensable. In the paper, the kinds of the membrane materials, which are used for the membrane structural buildings, and technical standards process of the creating for the membrane structure buildings are introduced. Lastly, some of the soccer stadiums for 2002 FIFA World Cup KOREA/JAPAN which be covered with the roof of the membrane structures are presented.

  • PDF

옥상녹화 방수 및 방근 기술로서 동판재의 적합성 및 시공성에 관한 연구 (A Study on the Workability and Application of Cooper Plate based on the Waterproofing and Root Penetration Resistance)

  • 박창화;조일규;권시원;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.151-154
    • /
    • 2007
  • To build up the green roofs, it must not adverse effect to durability and structural safety. That is conducted by safety system which consist of waterproofing to form basically, root barrier to protect the waterproofing. The reason why root barrier form is to protect the penetration force of root growth and the root could penetrate concrete surface, move inward so far. It may cause shorten the life span on concrete structure. For this problem, government constantly demand the solution to form the root barrier for waterproofing and concrete structure before the building is service. However, the technical action is not fully prepared. Therefore, in this study, we would like to suggest the workability and suitability of the copper plate to solve not only the side of waterproofing but also root barrier for green roof system and exhibit the mechanism for root penetration resistance and corrosion resistance.

  • PDF

Application of Three-dimensional Scanning, Haptic Modeling, and Printing Technologies for Restoring Damaged Artifacts

  • Jo, Young Hoon;Hong, Seonghyuk
    • 보존과학회지
    • /
    • 제35권1호
    • /
    • pp.71-80
    • /
    • 2019
  • This study examined the applicability of digital technologies based on three-dimensional(3D) scanning, modeling, and printing to the restoration of damaged artifacts. First, 3D close-range scanning was utilized to make a high-resolution polygon mesh model of a roof-end tile with a missing part, and a 3D virtual restoration of the missing part was conducted using a haptic interface. Furthermore, the virtual restoration model was printed out with a 3D printer using the material extrusion method and a PLA filament. Then, the additive structure of the printed output with a scanning electron microscope was observed and its shape accuracy was analyzed through 3D deviation analysis. It was discovered that the 3D printing output of the missing part has high dimensional accuracy and layer thickness, thus fitting extremely well with the fracture surface of the original roof-end tile. The convergence of digital virtual restoration based on 3D scanning and 3D printing technology has helped in minimizing contact with the artifact and broadening the choice of restoration materials significantly. In the future, if the efficiency of the virtual restoration modeling process is improved and the material stability of the printed output for the purpose of restoration is sufficiently verified, the usability of 3D digital technologies in cultural heritage restoration will increase.

초고층건물의 사각조망에서 촬영된 지붕표면 열화상의 신뢰도 평가 (Evaluating Reliability of Rooftop Thermal Infrared Image Acquired at Oblique Vantage Point of Super High-rise Building)

  • 류택형;엄정섭
    • 한국태양에너지학회 논문집
    • /
    • 제33권5호
    • /
    • pp.51-59
    • /
    • 2013
  • It is usual to evaluate the performance of the cool roof by measuring in-site rooftop temperature using thermal infra-red camera. The principal advantage of rooftop thermal infrared image acquired in oblique vantage point of super high-rise building as a remote sensor is to provide, in a cost-effective manner, area-wide information required for a scattered rooftop target with different colors, utilizing wide view angle and multi-temporal data coverage. This research idea was formulated by incorporating the concept of traditional remote sensing into rooftop temperature monitoring. Correlations between infrared image of super high-rise building and in-situ data were investigated to compare rooftop surface temperature for a total of four different rooftop locations. The results of the correlations analyses indicate that the rooftop surface temperature by the infrared images of super high-rise building alone could be explained yielding $R^2$ values of 0.951. The visible permanent record of the oblique thermal infra-red image was quite useful in better understanding the nature and extent of rooftop color that occurs in sampling points. This thermal infrared image acquired in oblique vantage point of super high-rise made it possible to identify area wide patterns of rooftop temperature change subject to many different colors, which cannot be acquired by traditional in-site field sampling. The infrared image of super high-rise building breaks down the usual concept of field sampling established as a conventional cool roof performance evaluation technique.

강우시 도시지역 강우 유출수 오염부하 기원평가 (Evaluating pollution origins of runoff in urban area by stormwater)

  • 황병기
    • 한국산학기술학회논문지
    • /
    • 제7권5호
    • /
    • pp.930-934
    • /
    • 2006
  • 홍제천 유역의 평창 배수분구를 대상으로 강우시 발생하수의 특성을 파악하기 위해 유량 및 수질 조사를 수행하였고, 강우유출수를 기저하수, 강우, 지붕유출수, 도로유출수, 관내 퇴적물 등 오염원별로 분석하여 기원별 초염기여도를 파악하였다. 강우시 발생초기의 오염물질의 농도는 초기세척현상에 의해 비강우시 농도의 3-10배 이상 높게 나타났으나, 강우 후반기에는 희석에 의해 비강우시 평균 농도 보다 오히려 낮은 농도를 보이는 것으로 나타났다. 오염부하의 오염원별 기여도 분석에서 관거 퇴적물에 의한 오염도가 전체 오염도에서 COD의 경우 54.6%를, SS은 73.3%를 차지하여, 가장 높은 기여도를 보여 관거 내 퇴적물의 준설과 세정을 통하여 상당량의 오염부하를 저감시킬 수 있는 것으로 나타났다.

  • PDF

Augmenting external surface pressures' predictions on isolated low-rise buildings using CFD simulations

  • Md Faiaz, Khaled;Aly Mousaad Aly
    • Wind and Structures
    • /
    • 제37권4호
    • /
    • pp.255-274
    • /
    • 2023
  • The aim of this paper is to enhance the accuracy of predicting time-averaged external surface pressures on low-rise buildings by utilizing Computational Fluid Dynamics (CFD) simulations. To achieve this, benchmark studies of the Silsoe cube and the Texas Tech University (TTU) experimental building are employed for comparison with simulation results. The paper is structured into three main sections. In the initial part, an appropriate domain size is selected based on the precision of mean pressure coefficients on the windward face of the cube, utilizing Reynolds Averaged Navier-Stokes (RANS) turbulence models. Subsequently, recommendations regarding the optimal computational domain size for an isolated building are provided based on revised findings. Moving on to the second part, the Silsoe cube model is examined within a horizontally homogeneous computational domain using more accurate turbulence models, such as Large Eddy Simulation (LES) and hybrid RANS-LES models. For computational efficiency, transient simulation settings are employed, building upon previous studies by the authors at the Windstorm Impact, Science, and Engineering (WISE) Lab, Louisiana State University (LSU). An optimal meshing strategy is determined for LES based on a grid convergence study. Three hybrid RANS-LES cases are investigated to achieve desired enhancements in the distribution of mean pressure coefficients on the Silsoe cube. In the final part, a 1:10 scale model of the TTU building is studied, incorporating the insights gained from the second part. The generated flow characteristics, including vertical profiles of mean velocity, turbulence intensity, and velocity spectra (small and large eddies), exhibit good agreement with full-scale (TTU) measurements. The results indicate promising roof pressures achieved through the careful consideration of meshing strategy, time step, domain size, inflow turbulence, near-wall treatment, and turbulence models. Moreover, this paper demonstrates an improvement in mean roof pressures compared to other state-of-the-art studies, thus highlighting the significance of CFD simulations in building aerodynamics.