• Title/Summary/Keyword: robot surgery

Search Result 129, Processing Time 0.036 seconds

Robotic Surgery in Cancer Care: Opportunities and Challenges

  • Mohammadzadeh, Niloofar;Safdari, Reza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.3
    • /
    • pp.1081-1083
    • /
    • 2014
  • Malignancy-associated mortality, decreased productivity, and spiritual, social and physical burden in cancer patients and their families impose heavy costs on communities. Therefore cancer prevention, early detection, rapid diagnosis and timely treatment are very important. Use of modern methods based on information technology in cancer can improve patient survival and increase patient and health care provider satisfaction. Robot technology is used in different areas of health care and applications in surgery have emerged affecting the cancer treatment domain. Computerized and robotic devices can offer enhanced dexterity by tremor abolition, motion scaling, high quality 3D vision for surgeons and decreased blood loss, significant reduction in narcotic use, and reduced hospital stay for patients. However, there are many challenges like lack of surgical community support, large size, high costs and absence of tactile and haptic feedback. A comprehensive view to identify all factors in different aspects such as technical, legal and ethical items that prevent robotic surgery adoption is thus very necessary. Also evidence must be presented to surgeons to achieve appropriate support from physicians. The aim of this review article is to survey applications, opportunities and barriers to this advanced technology in patients and surgeons as an approach to improve cancer care.

Robot Systemization of Ward Nursing Work (병동 간호업무의 로봇 시스템화)

  • Jang, Aeri;Cho, Yong Jin
    • Journal of Digital Convergence
    • /
    • v.19 no.3
    • /
    • pp.465-470
    • /
    • 2021
  • This study was attempted to predict the direction for ward nursing work through robotic systemization. Robot systems have not been universalized due to difficulties in operation, space constraints, and high prices. The robotic systemization should be focused on the robotic systemization of simple and repetitive tasks. The idea of a robot system for measuring vital signs and a robot system that helps bed sheet exchange is worth discussing with the engineering field. In addition, for successful nursing and interdisciplinary convergence, a detailed analysis of nursing work is required, and in order to overcome the trial and error of convergence, it is necessary to establish a converging society between nursing and interdisciplinary systems. Robotic systemization of successful ward nursing work will not only generate profits for hospitals, but also raise the status of nurses and will be the starting point for innovation in nursing work.

Application of Calibration Techniques to Enhance Accuracy of Markerless Surgical Robotic System for Intracerebral Hematoma Surgery (뇌혈종 제거 수술을 위한 무마커 수술 유도 로봇 시스템의 정확도 향상을 위한 캘리브레이션 기법)

  • Park, Kyusic;Yoon, Hyon Min;Shin, Sangkyun;Cho, Hyunchul;Kim, Youngjun;Kim, Laehyun;Lee, Deukhee
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.3
    • /
    • pp.246-253
    • /
    • 2015
  • In this paper, we propose calibration methods that can be applied to the markerless surgical robotic system for Intracerebral Hematoma (ICH) Surgery. This surgical robotic system does not require additional process of patient imaging but only uses CT images that are initially taken for a diagnosis purpose. Furthermore, the system applies markerless registration method other than using stereotactic frames. Thus, in overall, our system has many advantages when compared to other conventional ICH surgeries in that they are non-invasive, much less exposed to radiation exposure, and most importantly reduces a total operation time. In the paper, we specifically focus on the application of calibration methods and their verification which is one of the most critical factors that determine the accuracy of the system. We implemented three applications of calibration methods between the coordinates of robot's end-effector and the coordinates of 3D facial surface scanner, based on the hand-eye calibration method. Phantom tests were conducted to validate the feasibility and accuracy of our proposed calibration methods and the surgical robotic system.

First Experience of Thoracic Surgery with the da $Vinci^{TM}$ Surgical System in Korea (다빈치 수술로봇을 이용한 흉부수술 1예 보고)

  • Kim Dae-Joon;Chung Kyung-Young;Park In-Kyu;Park Sung-Yong
    • Journal of Chest Surgery
    • /
    • v.39 no.6 s.263
    • /
    • pp.482-485
    • /
    • 2006
  • Video-assisted thoracoscopic surgery has gained a broad acceptance for various thoracic lesions because it is the minimally invasive surgery with little tissue trauma, less pain, improved cosmetic results and short recovery time. However, there are some limitations for this method, such as restricted visual sensory information to a two-dimensional image and limited maneuverability of the tips of the instruments. To overcome these limitations, advanced technology has been introduced and the da $Vinci^{TM}$ Surgical System (Intuitive Surgical Inc, Mountain View, CA, USA) became available in 2001. In Korea, the da $Vinci^{TM}$ Surgical System was introduced in Severance hospital (Yonsei University College of Medicine) in May 2005, and approved by KFDA in July 2005. Herein, we report the first experience of robot-assisted thoracic surgery with the da $Vinci^{TM}$ Surgical System in extirpation of a large teratoma in anterior mediastinum.

Haptics for Human-Machine Interaction at The Johns Hopkins University

  • Okamura, Allison M.;Chang, Sung-Ouk
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2676-2681
    • /
    • 2003
  • The Haptic Exploration Laboratory at The Johns Hopkins University is currently exploring many problems related to haptics (force and tactile information) in human-machine systems. We divide our work into two main areas: virtual environments and robot-assisted manipulation systems. Our interest in virtual environments focuses on reality-based modeling, in which measurements of the static and dynamic properties of actual objects are taken in order to produce realistic virtual environments. Thus, we must develop methods for acquiring data from real objects and populating pre-defined models. We also seek to create systems that can provide active manipulation assistance to the operator through haptic, visual, and audio cues. These systems may be teleoperated systems, which allow human users to operate in environments that would normally be inaccessible due to hazards, distance, or scale. Alternatively, cooperative manipulation systems allow a user and a robot to share a tool, allowing the user to guide or override the robot directly if necessary. Haptics in human-machine systems can have many applications, such as undersea and space operations, training for pilots and surgeons, and manufacturing. We focus much of our work on medical applications.

  • PDF

Successful pregnancy following transmyometrial embryo transfer after robot-assisted radical trachelectomy

  • Hue, Hye Jeong;Choi, Hyun Ji;Park, Jee Yoon;Suh, Dong Hoon;Lee, Jung Ryeol;Jee, Byung Chul;Kim, Seul Ki
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.48 no.2
    • /
    • pp.184-187
    • /
    • 2021
  • Radical trachelectomy is a fertility-preserving alternative to radical hysterectomy in carefully selected young women with early-stage cervical cancer. However, in cases with subsequent severe cervical stenosis, assisted reproductive techniques can be difficult. This is a case report of a 34-year-old patient who underwent robot-assisted radical trachelectomy and cerclage for early-stage (IB2) adenosquamous carcinoma. Three months after surgery, the patient underwent ovarian stimulation using a gonadotropin-releasing hormone antagonist protocol. As it was impossible to perform transcervical embryo transfer due to the almost complete absence of the cervical opening, transmyometrial embryo transfer under ultrasound guidance was performed. This resulted in a successful singleton pregnancy. This is the first case of successful pregnancy conceived by in vitro fertilization with transmyometrial embryo transfer in a patient who had previously undergone robot-assisted radical trachelectomy.

Implementation of Auto Surgical Illumination Robotic System Using Ultrasonic Sensor-Based Tracking Algorithm (초음파 센서기반 추적 알고리즘을 이용한 자동 수술 조명 로봇 시스템)

  • Choi, Dong-Gul;Yi, Byung-Ju;Kim, Young-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.363-368
    • /
    • 2007
  • Most surgery illumination systems have been developed as passive systems. However, sometimes it is inconvenient to relocate the position of the illumination system whenever the surgeon changes his pose. To cope with such a problem, this study develops an auto-illumination system that is autonomously tracking the surgeon's movement. A 5-DOF serial type manipulator system that can control (X, Y, Z, Yaw, Pitch) position and secure enough workspace is developed. Using 3 ultrasonic sensors, the surgeon's position and orientation could be located. The measured data aresent to the main control system so that the robot can be auto-tracking the target. Finally, performance of the developed auto-illuminating system was verified through a preliminary experiment in the operating room environment.

Prototype Development of a Robotic System for Skull Drilling (로봇을 이용한 두개골 드릴링 시스템의 프로토타입 개발)

  • Chung, Yun-Chan
    • Korean Journal of Computational Design and Engineering
    • /
    • v.17 no.3
    • /
    • pp.198-207
    • /
    • 2012
  • This paper presents an overview of automated robotic system for skull drilling, which is performed to access for some neurosurgical interventions, such as brain tumor resection. Currently surgeons use automatic-releasing cranial perforators. The drilling procedure must be performed very carefully to avoid penetration of brain nerve structures; however failure cases are reported. The presented prototype system utilizes both preoperative and intraoperative information. Preoperative CT image is used for robot path planning. A NeuroMate robot with a six-DOF force sensor at the end effector is used for intraoperative operation. Intraoperative cutting force from the force sensor is the key information to revise an initial registration and preoperative path plans. Some possibilities are verified by path simulation but cadaver experiments are required for validation of this prototype.

A Perspective on Surgical Robotics and Its Future Directions for the Post-COVID-19 Era (포스트 코로나 시대 수술 로봇의 역할 및 발전 방향에 관한 전망)

  • Jang, Haneul;Song, Chaehee;Ryu, Seok Chang
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.2
    • /
    • pp.172-178
    • /
    • 2021
  • The COVID-19 pandemic has been reshaping the world by accelerating non-contact services and technologies in various domains. Hospitals as a healthcare system lie at the center of the dramatic change because of their fundamental roles: medical diagnosis and treatments. Leading experts in health, science, and technologies have predicted that robotics and artificial intelligence (AI) can drive such a hospital transformation. Accordingly, several government-led projects have been developed and started toward smarter hospitals, where robots and AI replace or support healthcare personnel, particularly in the diagnosis and non-surgical treatment procedures. This article inspects the remaining element of healthcare services, i.e., surgical treatment, focusing on evaluating whether or not currently available laparoscopic surgical robotic systems are sufficiently preparing for the era of post-COVID-19 when contactless is the new normal. Challenges and future directions towards an effective, fully non-contact surgery are identified and summarized, including remote surgery assistance, domain-expansion of robotic surgery, and seamless integration with smart operating rooms, followed by emphasis on robot tranining for surgical staff.

A Single-Center Experience of Robotic-Assisted Spine Surgery in Korea : Analysis of Screw Accuracy, Potential Risk Factor of Screw Malposition and Learning Curve

  • Bu Kwang Oh;Dong Wuk Son;Jun Seok Lee;Su Hun Lee;Young Ha Kim;Soon Ki Sung;Sang Weon Lee;Geun Sung Song;Seong Yi
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.1
    • /
    • pp.60-72
    • /
    • 2024
  • Objective : Recently, robotic-assisted spine surgery (RASS) has been considered a minimally invasive and relatively accurate method. In total, 495 robotic-assisted pedicle screw fixation (RAPSF) procedures were attempted on 100 patients during a 14-month period. The current study aimed to analyze the accuracy, potential risk factors, and learning curve of RAPSF. Methods : This retrospective study evaluated the position of RAPSF using the Gertzbein and Robbins scale (GRS). The accuracy was analyzed using the ratio of the clinically acceptable group (GRS grades A and B), the dissatisfying group (GRS grades C, D, and E), and the Surgical Evaluation Assistant program. The RAPSF was divided into the no-breached group (GRS grade A) and breached group (GRS grades B, C, D, and E), and the potential risk factors of RAPSF were evaluated. The learning curve was analyzed by changes in robot-used time per screw and the occurrence tendency of breached and failed screws according to case accumulation. Results : The clinically acceptable group in RAPSF was 98.12%. In the analysis using the Surgical Evaluation Assistant program, the tip offset was 2.37±1.89 mm, the tail offset was 3.09±1.90 mm, and the angular offset was 3.72°±2.72°. In the analysis of potential risk factors, the difference in screw fixation level (p=0.009) and segmental distance between the tracker and the instrumented level (p=0.001) between the no-breached and breached group were statistically significant, but not for the other factors. The mean difference between the no-breach and breach groups was statistically significant in terms of pedicle width (p<0.001) and tail offset (p=0.042). In the learning curve analysis, the occurrence of breached and failed screws and the robot-used time per screw screws showed a significant decreasing trend. Conclusion : In the current study, RAPSF was highly accurate and the specific potential risk factors were not identified. However, pedicle width was presumed to be related to breached screw. Meanwhile, the robot-used time per screw and the incidence of breached and failed screws decreased with the learning curve.