• 제목/요약/키워드: river load

검색결과 496건 처리시간 0.025초

하천수 열원 2단 압축 열펌프시스템의 부분부하 운전특성에 관한 실험적 연구 (An Experimental Study on the Part-Load Performance of a River Water Source 2-Stage Heat Pump)

  • 김지영;백영진;이영수;나호상
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1964-1968
    • /
    • 2007
  • The river water heat source heat pump has the advantage in the performance compared to air source heat pump. Although its better performance, the large temperature difference between load and source makes system performance worse by nature. In this study, 2-stage compression is considered as the solution of this problem. Generally, heat pump is designed for maximum capacity rate, but it actually operates at part load condition in many cases. Therefore, an information on the part-load character is very important in view of the system overall performance. In this study, part-load performance tests of a R134a 2-stage compression heat pump were carried out over the river water and supply heating water temperature changes. The experimental results show that the system performance is influenced by the part load rates, river water temperature, load temperature, etc.

  • PDF

유사량 산정에 관한 연구 (밀양강을 중심으로) (A Study on Sediment Load in the Milyang River)

  • 안세영;민벙형
    • 한국농공학회지
    • /
    • 제22권4호
    • /
    • pp.96-107
    • /
    • 1980
  • This study is carried out to estimate the rate of sediment transportation both to measure the amount of suspended and bedload sediment that moves on or near the river bed and passes through the cross section of a river in unit time, with suspended and bed load samplers used for the Milyang river and to determine the most satisfactory and convenient formula of some formulas for sediment discharge by comparing the measured rate with the calculated rate. The results of this study are summarized as follows; 1) The interrelationship (1) between the total discharge and the total sediment discharge (2) between discharge and suspended sediment load and (3) between discharge and bed load in the Milyang river are (1) i) 4$\leq$Q$\leq$100 C.M.S. Qr=0. 00272 Q0.70 (kg/sec) ii) 150$\leq$Q$\leq$800 C.M.S. Qr=0. 4807 Q0.46 (kg/sec) (2) Qs~=0. 07576 Q1.02 (kg/sec) (3) QB=0. 00957 Q0.44 (kg/sec) 2) The rate of suspended sediment load to total sediment discharge is found to be about; 99%. The suspended load is shown to be almost wash load which consists of silt and clay. 3) The relation between the total discharge and the suspended sediment load that are measured at three medium and small rivers in Korea is Qs=0. 13831 Q0.97 (kg/sec) 4) Brown's formula is determined to be the most convenient formula for application and comparison with observed data obtained for the Milyang river.

  • PDF

Evaluation of the tributaries by influence index on the mid-lower portion of the Nakdong River basin

  • Lee, Shun-Hwa;Jung, Seung-Gyu;Park, Seoung-Muk;Lee, Byung-Dae
    • Environmental Engineering Research
    • /
    • 제23권2호
    • /
    • pp.150-158
    • /
    • 2018
  • The deteriorating role of Nakdong River due to the Four Major Rivers Project has caused a series of problems, including water pollution, drying streams, aggravation of the hydroecology. Geumho River and Gyeongseong-cheon had a higher concentration index and is believed to impact the water quality of the main stream. The influence index of Geumho River and Nam River between 2015 and 2016, which have a large amount of discharge, was the highest among the tributaries in terms of the load material balance. Showing the highest average concentration and average load in the index assessment, Geumho River is believed to require an intensive management for improving the water quality of the main stream. Furthermore, when the cumulative percentage of the average concentration and average load was compared based on the water quality improvement of the tributaries mixed to Nakdong River, which was set to 60%, Geumho River, Nam River, Topyeong-cheon, and Cha-cheon, which showed the highest ratio in that order, were determined to require a water quality management program as a priority.

낙동강수계 수질오염총량관리를 위한 유량조사 평가 (Evaluation on Actual Discharge Data for TMDL in Nakdong River Basin)

  • 김경훈;김용석;박배경;윤종수;신찬기
    • 환경위생공학
    • /
    • 제23권4호
    • /
    • pp.65-71
    • /
    • 2008
  • To drive efficiently total water pollution load management, needs to calculate the exact load emissions, pollution load allocation and implementation evaluation in each unit area of watershed and accurate and regular flow of data. For these reasons, the Nakdong River TMDL Research Center has produced directly or indirectly in the average interval of eight days (30 times or more / year) 41 points for unit area of the total water pollution load management and 8-point of municipal requirement for a total of 49 branches as a flow data in 2004 from August. This acquired the survey flow is evidence of trends and changes each point in the Nakdong River based on time, such as 10 years based on average design flow available to the foundation of the summit as the major water policy is to be utilized. This study was performed on actual discharge measuring data and introduced performance results each drainage basin of Nakdong River from 2004 to 2008 over the total of past five years.

금호강 유역의 대장균 부하지속곡선 개발 및 적용 (Development and Application of Coliform Load Duration Curve for the Geumho River)

  • 정강영;임태효;김경훈;이인정;윤종수;허성남
    • 한국물환경학회지
    • /
    • 제28권6호
    • /
    • pp.890-895
    • /
    • 2012
  • Duration curves describe the percentage of time that a certain water quality (total/fecal coliform (=TC/FC)) or discharge is exceeded. The curves methodology are usually based on daily records and are useful in estimating how many days per year and event will be exceeded. The technique was further applied to estimated TC/FC loading to the Geumho River, using the daily mean flow rate and TC/FC concentration data during January, 2001 and December, 2011 for the Geumhogang6 (=Seongseo water level station) where an automated monitoring station is located in Gangchang-bridge. Low flow of the Seongseo (=11.1 cms) was equivalent to 75.3% on an exceedance probability scale. Load Duration curve for TC/FC loading at the Seongseo was constructed. Standard load duration curve was constructed with the water quality criteria for class III (TC/FC concentration = 5000/1000 CFU/ 100 mL). By plotting TC/FC observed load duration curve with standard load duration curve, it could be revealed that water quality do not meet the desired water quality for 68.8/11.2% on an exceedance probability scale. IF linear correlation between flow rate and coliform concentration is assumed, it can be interpreted that water quality exceed desired criteria when daily average flow rate is over 11.9/109.9 cms.

낙동강유역 과수재배지의 단위면적당 비점오염부하량 산정에 관한 연구 (The Calculation of NPS Load per Unit Area in Orchard to the Nakdong River Basin)

  • 이재운;권헌각;이윤정;천세억
    • 환경영향평가
    • /
    • 제22권6호
    • /
    • pp.557-568
    • /
    • 2013
  • In this study, Calculated the nonpoint sources(NPS) load per unit area about various rainy events in vineyard of Nakdong River basin. NPS monitoring and calculation for NPS load per unit area were estimated from 'Investigation method of precipitation discharge(National Institute of Environmental Research, 2007)'. The evaluation of applicability for NPS load per unit by compared with prior research data and Total Maximum Daily Load(TMDL) data. Five target areas were each $2000m^2$, $1800m^2$, $1943m^2$, $2484m^2$, $864m^2$ and located in Gyeongsangbukdo Gyeongju, Gyeongsangbukdo Sangju, Gyeongsangnamdo Hapcheon in Korea. Since fruits were the only crop on the target area, the characteristics of stormwater discharge at survey sites could be evaluated independently. A total of 115 rainfall events in the Orchard area during five years(2008-2012) was surveyed, and 38 of them became stormwater discharge. In the Nakdong River watershed, average of event mean concentrations(EMCs) in Orchard area for biochemical oxyzen demand(BOD), Chemical oxyzen demand(COD), total nitrogen(T-N), total phosphorus(T-P) were 2.0mg/L, 10.1mg/L, 3.195mg/L, 0.578mg/L, respectively. NPS load per unit area in Orchard area showed BOD : $2.0kg/km^2{\cdot}day$, COD : $10.2kg/km^2{\cdot}day$, T-N : $3.220kg/km^2{\cdot}day$, T-P : $0.606kg/km^2{\cdot}day$.

2단 압축 수열원 열펌프 시스템의 부분부하 운전특성에 관한 연구 (A study on the part-load performance of 2-stage water source heat pump)

  • 이영수;백영진
    • 한국지열·수열에너지학회논문집
    • /
    • 제5권1호
    • /
    • pp.13-17
    • /
    • 2009
  • The river water heat source heat pump has the advantage in the performance compared to air source heat pump. In this study, an experimental study on a 2-stage heat pump, which is designed to utilize a river water heat source, were carried out. Generally, a heat pump is designed for maximum capacity rate, but it actually operates at part load condition in most cases. Therefore, an information on the part-load characteristic is very important in view of the system overall performance. In this study, part-load performance tests of a R134a 2-stage compression heat pump were carried out over the river water and supply heating water temperature changes.

  • PDF

진위천 단위유역의 유량-수질 특성 및 하천 등급화 평가 (Evaluation of Discharge-Water Quality Characteristics and River Grade Classification of Jinwi River Unit Basin)

  • 조용철;최진우;노창완;권필상;김상훈;유순주
    • 환경영향평가
    • /
    • 제27권6호
    • /
    • pp.704-716
    • /
    • 2018
  • 본 연구는 진위천 단위유역의 수질오염총량제도에 따른 유량 및 수질 특성을 정확히 파악하고 목표 수질을 달성하기 위하여 수질 개선이 우선적으로 필요한 총량 지점을 선정하여 관리 방안을 제시하는 것이다. 진위천 단위유역의 2014년부터 2016년까지 14개 총량 지점을 대상으로 유량 및 수질 특성, 통계 분석, 유달부하량 및 유달부하 밀도 산정, 하천 등급화 등을 평가하였다. 진위천 단위유역의 유량은 평균 $22.411m^3/s$이고 황구지천의 유량이 32.8%를 차지하였으며 지류 하천에 따른 공간적으로 수질특성이 뚜렷하게 나타났다. 주성분 분석 결과 오산천과 황구지천은 유기오염 간접지표 및 계절적 요인, 성은천은 유기오염 간접지표 요인, 관리천은 계절적 요인이 수질에 영향을 미치는 것으로 분석되었다. 유달부하량 산정 결과 HG-3 지점에서 6,470.4 BOD kg/day, 6,846.7 TN kg/day로 높게 나타났으며 유달부하 밀도는 HG-4 지점에서 $220.9BOD\;kg/day/km^2$, $22.4TP\;kg/day/km^2$로 높게 나타났다. 하천 등급화 방법을 이용한 진위천 단위유역의 수질 개선이 우선으로 필요한 총량 지점은 HG-3 지점으로 나타났다.

금호강, 남강 중권역 지류·지천의 상세오염 현황 및 오염기여율 조사 (Analysis of Specific Contaminated Status and Pollutant Loads Contribution Rate of the Tributaries in Gumho and Nam River Basin)

  • 나승민;권헌각;김경훈;신동석;임태효
    • 한국습지학회지
    • /
    • 제18권4호
    • /
    • pp.363-377
    • /
    • 2016
  • 본 연구는 낙동강수계 오염도가 높은 금호강 및 남강 중권역의 지천들 가운데 수질측정망과 일정한 거리에 있고 오염도가 높은 지천들을 선정하여 각 지점의 오염부하량, 오염특성, 중점관리지천별 세부 유입되는 지천의 오염현황 및 중점 지류가 낙동강 본류에 미치는 영향 등을 살펴보았다. 그 결과, 금호강 및 남강의 대부분의 수질항목별 오염도는 유사하였으나, TN, Chl-a 및 SS는 금호강이 남강에 비해 약 20~120% 이상 높은 오염도를 보였다. 오염발생부하율(kg/day) 및 발생밀도($kg/day/km^2$)는 유량과 하천유하면적에 따라 하천 오염도 순위가 달랐으며, 이러한 영향은 남강에서 더 크게 차이가 발생하였다. 금호강 및 남강의 상세오염조사는 하천의 유로길이, 합류되는 소하천의 개수와 형태에 따라 상세지점을 2개에서 최대 9개까지 나누어 조사하였으며, 그 결과 달서천과 의령천의 오염도가 높게 나타났다. 이외에도, 달서천과 의령천의 본류오염 기여율이 약 10% 내외로 높게 나타났으며, 이는 주변공단, 생활거주지역 형태 및 크기, 농경지 경작 유 무 및 축사 존재 유 무에 따라 오염도 및 상 하류 오염형태가 다르기 때문으로 판단된다

Assessment of Pollution Levels in the Jangsungcheon Watershed Using Load Duration Curves and Analysis of the Causes

  • Cho, Sohyun;Bak, Jonghun;Lee, Yeong Jae;Kim, Kyunghyun;Jung, Kang Young
    • 한국환경과학회지
    • /
    • 제28권10호
    • /
    • pp.873-885
    • /
    • 2019
  • In this study, a load duration curve was applied to the Jangseongcheon, one of the tributaries of the Yeongsan River, to assess whether the target water quality was achieved. In addition, pollution of the water body was investigated to develop and suggest the optimal management time with respect to polluted flow sections and monthly conditions. The average flow rates of sections JS1 and JS2 were $0.25m^3/s$ and $1.08m^3/s$, respectively. The BOD and T-P for water-quality standards at JS1 were rated at II, whereas the COD and TOC were rated at III, thus indicating a fair level of water quality. By contrast, the BOD at JS2 was rated at III, the T-P at IV, and the TOC at V, indicating poor water quality in this section. The load duration curve was plotted using the actual flow data measured in eight-day intervals for eight years from 2011 to 2018 at locations JS1 and JS2 in the Jangsungcheon Basin. In an assessment using the load duration curve on whether the target water quality was met at location JS1, all of the water quality parameters (BOD, COD, TOC, T-N, T-P, and SS) satisfied the target water quality. By contrast, at location JS2, parameters COD, TOC, T-N, and T-P exceeded target values by more than 50%, indicating the target water quality was not met. The discharge loads of locations JS1 and JS2 were analyzed to identify the reasons the target water quality was exceeded. Results revealed that the land system contributed considerably. Furthermore, the discharge load of JS2 accounted for more than 80% of the load on the entire basin, excluding that of JS1. Therefore, the best method for restraining the inflow of pollutants into the stream near location JS2 must be applied to manage the water quality of the Jangsungcheon.