• Title/Summary/Keyword: rinse time

Search Result 52, Processing Time 0.021 seconds

The effect of MTAD on the apical leakage of obturated root canals: an electrochemical study (MTAD의 치근단 누출에 미치는 영향에 대한 전기화학적 연구)

  • Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.2
    • /
    • pp.119-124
    • /
    • 2006
  • The purpose of this study was to evaluate the effect of newly developed endodontic root canal cleanser (MTAD) on the apical leakage of obturated root canal using an electrochemical method. Canals of 60 extracted single-rooted human teeth were prepared by using a crown-down technique with rotary nickel-titanium files. In Group 1 (positive control group) and 2 (negative centre) group), 5.25% NaOCl was used as a canal irrigant and no canal wall treatment was done. In group 3 only 5.25% NaOCl were used as canal irrigant, canal wall treatment and final rinse. In group 4, specimens were irrigated with 5.25% NaOCl, treated with 5 ml of 17% EDTA for 5 minutes and final rinsed with 5.25% NaOCl Specimens of group 5 were irrigated with 1 3% NaOCl and treated with 5 ml of MTAD for 5 minutes. All root canals are dried with paper points and obtuated with gutta-percha and AH plus as a sealer using a continuous wave of condensation technique except in the group 1. The electrical resistance between the standard and experimental electrodes in canals was measured over a period of 10 days. Rising of apical leakage with time was observed for all the groups. Group 4 and 5 showed lower apical leakage than group 3 but differences between the group 3, 4 and 5 were no statistical significance at any measurement time.

Fabrication of Nanopatterned Oxide Layer on GaAs Substrate by using Block Copolymer and Reactive Ion Etching (블록 공중합체와 반응성 이온식각을 이용한 GaAs 기판상의 나노패터닝된 산화막 형성)

  • Kang, Gil-Bum;Kwon, Soon-Mook;Kim, Seoung-Il;Kim, Yong-Tae;Park, Jung-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.4
    • /
    • pp.29-32
    • /
    • 2009
  • Dense and periodic arrays of nano-sized holes were patterned in oxide thin film on GaAs substrate. To obtain the nano-size patterns, self-assembling diblock copolymer was used to produce thin film of uniformly distributed parallel cylinders of polymethylmethacrylate (PMMA) in polystyrene (PS) matrix. The PMMA cylinders were removed with UV expose and acetic acid rinse to produce PS nanotemplate. By reactive ion etching, pattern of the PS template was transferred to under laid silicon oxide layer. Transferred patterns were reached to the GaAs substrate by controlling the dry etching time. We confirmed the achievement of etching through the removing oxide layer and observation of GaAs substrate surface. Optimized etching time was 90 to 100 sec. Pore sizes of the nanopattern in the silicon oxide layer were 20~22 nm.

  • PDF

Development of an Automatic Nutrient-Solution Mixing and Supplying System (다구역 재배용 양액 자동 조제.공급 시스템 개발)

  • 김기영;전성필;류관희
    • Journal of Bio-Environment Control
    • /
    • v.9 no.1
    • /
    • pp.11-19
    • /
    • 2000
  • In recent, multi-sector nutriculture in which each sectors are managed with different compositions and supplying amounts of nutrient solution is being prevalent especially in large-scale greenhouses. This study was carried out to develop an automatic mixing and supplying system of nutrient solution for the multi-sector greenhouse which can control various compositions of nutrient solution and supplying amounts for each sector. The stock solution control device could control discharge of the stock solution with device actuating time. The experimental result showed high correlation between the discharge and the actuating time. The system could make nutrient solution of various compositions and showed possibility of changing compositions of nutrient solution according to changes of growth stages or environments. Undesirable remnant nutrient-solution effect on the next supply was decreased by lowering RC of the previous nutrient solution remaining in the tank and supply pipe through rinse process. To evaluate performance of the developed system, experiments that compare N $O_3$$^{[-10]}$ , and P $O_4$$^{3-}$ concentrations of nutrient solution made in laboratory level with those made by the developed system were conducted. The experimental results showed that the deviations for N $O_3$$^{[-10]}$ , and P $O_4$$^{3-}$ concentrations of nutrient solution composited by the developed system were -2.36% and -5.15%, respectively.

  • PDF

Stimulation of Seed Germination of Korean Lawn grass (Zoysia japonica Steud.) by Sodium Hypochlorite Treatment (Sodium Hypochlorite 처리(處理)에 의한 한국잔디 종자(種子)의 발아촉진(發芽促進))

  • Ku, Ja Hyeong;Lee, Jong Suk;Lee, Young Bok
    • Korean Journal of Agricultural Science
    • /
    • v.11 no.2
    • /
    • pp.201-206
    • /
    • 1984
  • In order to obtain an easy and effective scarification method for stimulating the seed germination of Korean lawn grass (Zoysia japonica Steud.), sodium hypochlorite (SH), which is used as a commercial bleach and a seed disinfestant, was tested as a chemical scarifier instead of potassium hydroxide (KOH). 1. Scarification with 4% SH for 2 hours followed by 8-hour water-rinse stimulated seed germination more effectively compared to generalized scarification method by KOH treatment. 2. The degree of stimulating seed gemination was different by the various water-rinsing time after SH treatment, but the optimum rinsing time was about 4 to 8 hours. 3. GA treatment after SH scarification stimulated seed germination. However, the stimulation effect of GA was not showed in non-scarified control. 4. SH treatment significantly decreased the percentage of the infection of microflora in seed samples compared to KOH treatment. 5. Under practical seed scarification conditions for stimulating germination of Korean lawn grass seed. SH may have advantages over KOH with respect to ease of preparing, securing and handling.

  • PDF

The Incidence of Microorganisms during the Slaughtering Process of Chicken (닭 도계공정 중의 미생물 증감 추이)

  • Cha Seong Kwan;Seo Mi Young;Kim Yoon Sook;Kim Myung Ho;Kim Yun Ji
    • Food Science of Animal Resources
    • /
    • v.24 no.4
    • /
    • pp.335-341
    • /
    • 2004
  • This study was carried out to evaluate the microbiological quality of poultry carcasses at different slaughtering process in large (>50,000 chicken/day) and small (<30,000 chicken/day) scale slaughtering houses. Whole bird rinse technique was used to analyze the incidence of microorganisms on poultry carcasses in each process of before visceration, after evisceration, after final wash, after main chilling and in cold room. In summer time, small scale slaughterhouse showed lower incidence of aerobic microorganisms (10$\^$4/ CFU/mL) than those of large scale slaughterhouse (10$\^$5/ CFU/mL) at the process of after main chilling and in cold room. But small scale slaughterhouse showed higher incidence of E. coli (10$^2$-10$^4$ CFU/mL) than those of large scale slaughterhouse (10$\^$-2/ CFU/mL) at each slaughtering process observed. During autumn and winter time, small scale slaughterhouse showed similar incidence of aerobic microorganisms as large scale slaughterhouse (10$\^$5/ CFU/mL after evisceration, 10$^4$ CFU/mL after main chilling and cold storage). Samples from carcasses during autumn and winter time in cold room showed no difference in E. coli counts (10$^2$ in autumn time and 10$^3$ CFU/mL in winter time) between large and small scale slaughterhouse. In spring time, small scale slaughterhouse showed lower incidence of aerobic microorganisms than those of large scale slaughterhouse at each slaughtering process observed except after main chilling. Small scale slaughterhouse showed higher incidence of aerobic microorganisms in final cooling water than large scale slaughterhouse during spring time.

Effect of a Mouthwash Containing Cetylpyridinium and Zinc Chloride on Oral Malodor (세틸피리디늄(Cetylpyridinium) 및 염화아연(Zinc chloride)을 함유한 구강 양치액의 구취제거 효과에 대한 연구)

  • Kim, Ju-Sik;Park, Ji-Woon;Kim, Dae-Jung;Kim, Young-Ku;Lee, Jeong-Yun
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.4
    • /
    • pp.245-252
    • /
    • 2011
  • The aim of this study is to clinically evaluate the effect of a mouthwash containing cetylpyridinium and zinc chloride on reduction of morning oral malodor in healthy subjects measured by organoleptic measurement and a portable sulfide monitor. A total of 8 healthy non-smoking male volunteers were enrolled in this study of crossover design consisting of two experimental phases. The subjects were instructed to rinse the mouth with 10 mL of the experimental mouthwash containing cetylpyridinium and zinc chloride for 30 seconds at the first phase. At the second phase after a one-week washout period, each subject rinsed with distilled water as a control. All experiments were conducted at around 8:30 a.m. and oral malodor was measured using organoleptic measurement and a portable sulfide monitor just before rinsing with the experimental mouthwash or control (baseline), 1 hr, 2 hrs, and 3 hrs after rinsing. The mouthwash containing cetylpyridinium and zinc chloride reduced morning oral malodor up to 3 hrs after rinsing. Organoleptic score and concentrations of volatile sulfur compounds after use of the experimental mouthwash significantly decreased with time, and the decreases were significantly different between the mouthwash and control. In conclusion, the mouthwash containing cetylpyridinium and zinc chloride is significantly effective on reduction of morning oral malodor in healthy subjects by 3 hrs.

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF

A Study on Influential Factors for the Effective Demand of Workers for Dental Treatment (근로자들의 유효구강보건진료수요에 영향을 미치는 요인에 관한 연구)

  • Park, Chung-Soon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.10 no.5
    • /
    • pp.819-829
    • /
    • 2010
  • Objectives : The purpose of this study was to examine factors affecting the effective demand of workers for dental treatment in a bid to provide some information on the improvement of oral health. Methods : The subjects in this study were 255 workers who were engaged in the pharmaceutical industry. A self-administered survey was conducted, and the collected data were analyzed by a spss(statistical package for the social science) win 12.0 program to find out their demographic characteristics, oral health awareness, oral health behavior and factors for the choice of a dental institution. Results : 1. Concerning the level of oral health awareness, 47.0 percent were at a low level(0 to three scores), and 35.2 percent were at an intermediate level(four to six scores). 2. As to oral health behavior involving a daily mean toothbrushing frequency, they brushed their teeth 2.65 times per day on the average. The most widely utilized oral hygiene supply was mouth rinse. Regarding oral health status, 53.7 percent weren't in good dental health, and just 23.0 percent got a dental checkup on a regular basis. 45.8 percent of those who didn't get a dental checkup cited time constraints as the reason. 26.0 percent received oral health education, and 91.4 percent were aware of the necessity of a corporate incremental dental care system. 3. Marital status, age and the reliability of dental institutions made differences to their choice of a dental institution. 4. As for the relationship between oral health awareness and the factors for the choice of a dental institution, oral health awareness had a statistically significant positive correlation to the reliability of dental institutions. Conclusions : The above-mentioned findings suggest that oral health education enables workers to have a correct knowledge on oral health, to change their own oral health behavior and to make the right choice of a dental institution in consideration of their oral characteristics. They should be urged to get a regular dental checkup not to develop chronic oral diseases so that they couldn't have to receive first-aid dental treatment. To promote the oral health of workers, oral health care personnels available should be utilized, and the incremental dental care system should be more vitalized to cut down on their effective demand for dental treatment.

A study on oral health status and oral health behavior practice perceived by workers in part areas (일부 지역의 근로자가 지각하는 구강건강상태와 구강건강행위실천에 관한 연구)

  • Kim, Mi-Jeong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.1
    • /
    • pp.201-212
    • /
    • 2012
  • Objectives : The purpose of this study was to examine about workers' oral health status and oral health behavior practice. Methods : Questionnaire survey was carried out targeting 331 workers within the industrial complex of Jeonju city in 2011. As a result of surveying and analyzing workers' oral health status, habit related to oral health, activity restriction, which is oral disease phase, and oral health practice level by using SPSSWIN 12.0. Results : 1. Workers' experience of visiting dental hospital(clinic) for the past one year was indicated to be the highest with 64.9% in the working period with 10 years-under 20 years(p<0.001). Experience of scaling was indicated to be averagely 38.8%. 2. The oral health status perceived by workers was the highest with 40.5% in 'having something abnormal'. A problem was the highest with 28.0% in 'dental caries'. A cause was indicated to be 42.6% in 'because of being naturally weak in tooth or the gum.' The biggest reason for having failed to receive the dental treatment at a proper time was indicated to be the highest with 24.8% in 'because of feeling burdensome about dental expense. '3. 58.4% of male workers were smoking. The use of dental hygiene device was the highest with 40.6% in mouth-rinse. 4. Absence caused by oral disease was indicated to be the highest with 13.8% in the household income in more than 3,500,000won, thereby having shown the significant difference(p<0.05). Early leaving was indicated to be the highest 13.9% in more than 50s age, thereby having shown the significant difference(p<0.05). Also, as for factors of absence and early leaving, a pain was the highest with 64.7%. 5. Workers' oral health practice level was the highest with 2.85 points in 'Brushing teeth before going to bed'. Conclusions : Synthesizing these findings, the oral management could be known to be made negligently in the workers with the older age, the lower academic background, and the lower income. The institutional foundation is considered to be necessary for which the oral health education can be efficiently performed in addition to a need of periodic oral examination for these classes.

REAL-TIME MEASUREMENT OF DENTINAL TUBULAR FLUID FLOW DURING AND AFTER AMALGAM AND COMPOSITE RESTORATIONS (아말감과 복합레진의 수복 과정과 수복 후 발생하는 상아세관액 흐름의 실시간 측정)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lim, Bum-Sun;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.467-476
    • /
    • 2009
  • The aim of this study was to measure the dentinal tubular fluid flow (DFF) during and after amalgam and composite restorations. A newly designed fluid flow measurement instrument was made. A third molar cut at 3 mm apical from the CEJ was connected to the flow measuring device under a hydrostatic pressure of 15 $cmH_2O$. Class I cavity was prepared and restored with either amalgam (Copalite varnish and Bestaloy) or composite (Z-250 with ScotchBond MultiPurpose: MP, Single Bond 2: SB, Clearfil SE Bond: CE and Easy Bond: EB as bonding systems). The DFF was measured from the intact tooth state through restoration procedures to 30 minutes after restoration, and re-measured at 3 and 7days after restoration. Inward fluid flow (IF) during cavity preparation was followed by outward flow (OF) after preparation, In amalgam restoration, the OF changed to IF during amalgam filling and slight OF followed after finishing. In composite restoration, application CE and EB showed a continuous OF and air-dry increased rapidly the OF until light-curing, whereas in MP and SB, rinse and dry caused IF and OF, respectively. Application of hydrophobic bonding resin in MP and CE caused a decrease in flow rate or even slight IF. Light-curing of adhesive and composite showed an abrupt IF. There was no statistically significant difference in the reduction of DFF among the materials at 30 min. 3 and 7 days after restoration (p > 0.05).