• Title/Summary/Keyword: rinse time

Search Result 52, Processing Time 0.026 seconds

A study on how lifestyle and shampoo habits affect middle-aged men with seborrheic Scalp - especially office workers (30~50대 중장년층 남성의 생활과 샴푸 습관이 지루성 두피에 미치는 영향에 관한 연구 : 사무직 군무 종사자들을 중심으로)

  • Lee, Jong-Youl;You, Seon-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.701-707
    • /
    • 2016
  • This study surveyed 150 men aged 30 to 50, a demographic which seborrheic dermatitis is common. The time of day one shampoos and recurrent fatigue were found to have a statistically significant impact on symptoms contributing to the main causes of seborrhea, including itchiness, excessive oil, acne, and redness on the scalp (p<0.01). Study results confirm lifestyle and shampoo habits, such as the frequent sense of fatigue, a routine work schedule, susceptibility to stress, the time of day one uses shampoo, and whether hair styling products are used, affects seborrheic scalp disease. This study found seborrheic scalp disease for office workers primarily resulted from shampoo habits, rashes were predominantly caused by a failure to rinse shampoo and dry hair completely, while secondary aggravating factors included irregular work schedules, recurrent tiredness, and chronic stress.

EFFECT OF WETTING CONDITION ON BONDING OF RESIN CEMENT TO DENTIN (상아질 표면의 건조에 따른 습윤상태가 레진세멘트의 접착에 미치는 영향)

  • Son, Kang-Ha;Park, Jin-Hoon;Cho, Kyeu-Zeung
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.1
    • /
    • pp.97-112
    • /
    • 1995
  • The purpose of this study was to evaluate the effect of wetting condition made by drying time on bonding of resin cement to dentin. Freshly extracted bovine teeth were grinded to expose flat dentin surfaces. After the exposed dentin surfaces were treated with pretreatment agents and water rinse, each wetting condition of dentin surfaces was made according to drying times and methods including slight blow bry for I-second by air syringe, blow dry for 20-second by air syringe, and 12-hour dry in desiccator respectively. and then, previously made composite resin specimens were bonded onto each conditioned dentin surface of the specimen using Panavia-21(Kuraray Co.), Bistite(Tokuso Co.), and Choice(use with All bond-2, Bisco Inc.) resin cement according as manufacturer's instruction. Bonded specimens were stored in $37^{\circ}C$ distilled water for 24 hours, then the tensile bond strength was measured, cohesive failure rate was calculated, and fractured dentin surfaces and acrylic rod sides were examined under scanning electron microscope. The result were as follows ; In the group of bonding with Panavia-21 resin cement, higher tensile bond strength was seen in 12-hour dry group than in I-second and 20-second dry group(p<0.01). In the group of bonding with Bistite resin cement, higher tensile bond strength was seen in 1-second dry group than in 20-second and 12-hour dry group(p<0.01). In the group of bonding with Choice resin cement, no significant differences of bond strength under given drying time were seen. Cohesive failure rates derived from the groups of bonding with Panavia-21 and Choice resin cement were increased with the increase of tensile bond strength in each drying time. On SEM examination of fractured surface, adhesive failure mode with fractured resin tags was mostly seen in wet condition with I-second drying time in the group of bonding with Panavia-21 resin cement, mixed failure mode with shortened and fractured resin tag was seen in the group of bonding with Bistite resin cement, and regardless of drying time, and cohesive-adhesive mixed failure mode with fracture of 'Hollow' typed resin tags was mainly seen in the group of bonding with Choice resin cement.

  • PDF

Effects of Bamboo Salt with Sodium Fluoride on the Prevention of Dental Caries

  • Lee, Hye-Jin;Park, A-Reum;Oh, Han-Na
    • Journal of dental hygiene science
    • /
    • v.19 no.4
    • /
    • pp.288-293
    • /
    • 2019
  • Background: Dental caries is one of several prevalent oral diseases caused by dental plaque biofilms. This study evaluated the anti-cariogenic effects of a bamboo salt (BS) and sodium fluoride (NaF) mixture on oral bacteria. Methods: The effects of several mixtures of NaF and BS on acid production, growth, and adhesion to glass beads of Streptococcus mutans, and their anti-cariogenic properties were investigated. The growth of S. mutans was measured according to optical density at 3, 6, 9, 12, 15, 18, and 24 hours after treatment using spectrophotometry at a wavelength of 600 nm, while pH was measured using a pH meter. Adhesion of S. mutans was measured according to the weight of glass beads from each group before and after incubation. Gene expression was measured using real-time polymerase chain reaction. Acid production and growth patterns of S. mutans were compared using repeated measures analysis of variance, followed by Scheffe's post-hoc test. The Kruskal-Wallis test was used to compare adhesion, followed by the Mann-Whitney test. Gene expression in the experimental and control samples was compared using the Student's t-test. Results: Growth, acid production, and adhesion of S. mutans were inhibited in all experimental groups. Expression of gft and fructosyltransferase in S. mutans was inhibited in all groups. A mixture of NaF and BS significantly reduced growth, acid production, adhesion, and gene expression of S. mutans compared with the other groups. Conclusion: Results of the present study demonstrated that a mixture of NaF and BS was useful as a mouth rinse in preventing dental caries.

Study on Heavy Metal Desorption and Recovery of the Carbon Foam used in Industrial Plating Wastewater Treatment as Adsorbent (산업도금폐수 처리에 사용된 탄소폼 흡착소재의 중금속 탈착 및 회수에 관한 연구)

  • Lee, Da-Young;Lee, Chang-Gu;Kim, Dae-Woon;Park, Sang-Hyen;Kweon, Ji-Hyang;Lee, Sang-Hyup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.11
    • /
    • pp.627-634
    • /
    • 2016
  • We investigated the characteristics of heavy metal desorption and recovery from carbon foam after plating wastewater treatment. The heavy metal desorption depends on solution chemistry because desorption occurred in HCl and $H_2SO_4 $ solution but did not occur in distilled water. Heavy metal desorption efficiency was increased using ultrasonication with desorption solution. The higher ultrasonic power and the longer reaction time improve efficiency. The copper plating rinse solution was treated reliably by carbon foam adsorbent during 200 bed volume. The adsorbed copper was dissolved using desorption solution and recovered by DC power supply. After copper recovery, the reuse efficiency of desorption solution was 84.2%.

Nondestructive, Quantitative Synchrotron Grazing Incidence X-ray Scattering Analysis of Cylindrical Nanostructure in Supported Thin Films

  • Yoon, Jin-Hwan;Yang, Seung-Yun;Lee, Byeong-Du;Joo, Won-Chul;Heo, Kyu-Young;Kim, Jin-Kon;Ree, Moon-Hor
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.300-300
    • /
    • 2006
  • Nondestructive nanostructural analysis is indispensable in the development of nano-materials and nano-fabrication processes for use in nanotechnology applications. In this paper, we demonstrate for the first time a quantitative, nondestructive analysis of nanostructured thin films supported on substrates and their templated nanopores by using grazing incidence X-ray scattering and data analysis with a derived scattering theory. Our analysis disclosed that vertically oriented nanodomain cylinders had formed in 20-100 nm thick films supported on substrates consisting of a mixture of poly(styrene-b-methyl methacrylate) (PS-b-PMMA) and PMMA homopolymer, and that the PMMA nanodomains were selectively etched out by ultraviolet light exposure and a subsequent rinse with acetic acid, resulting in a structure consisting of hexagonally packed cylindrical nanopores.

  • PDF

THE EFFECT OF MOUTH RINSE PRODUCTS CONTAINING DEEP SEA WATER (해양심층수를 이용한 구강청정제의 효과)

  • Kim, Seon-Ah;Jang, Hae-Jin;Yoo, Yung-Geun;Chu, Yong-Shik;Park, Yang-Ho;Park, Jun-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.6
    • /
    • pp.601-608
    • /
    • 2007
  • The aim of this study was to evaluate the effect of mouthrinse products containing deep sea water. We used original deep sea water(DSW) and processed deep sea water desalinated by reverse osmosis at one time(DDW-1), by reverse osmosis at two times(DDW-2) and concentrated by reverse osmosis(CDW). We made 2 kinds of mouthrinse products containing CDW and other agents for smell and taste and one product without deep sea water. The negative control was distilled water. In vivo study, the dental plaque index scores and the gingival index scores were reduced after 4 weeks mouthrinsing three times daily with 4 kinds of deep sea water and 3 kinds of mouthrinse products(p<0.05). The pH of dental plaque in 1 minute after mouthrinsing was not higher than 5.5 in all solutions, but the pH in 20 minutes after mouthrinsing was higher than 5.7 in DSW, CDW and 3 kinds of products which had higher mineral contents. In vitro study, the mouthrinse solutions containing the higher mineral contents were also the more effective in reduction of methyl mercaptan which is one of the causes of halitosis. The 2 kinds of products containing deep sea water killed Streptococcus mutans(ATCC 25175) in culture plates in one minute. These results indicate the usability of deep sea water in mouthrinses for oral hygiene management.

Electroplating process for the chip component external electrode

  • Lee, Jun-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.1-2
    • /
    • 2000
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the onventional rotating barrel, vibrational barrel(vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components. The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed thatbthe average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value. Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components. However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. 2H20 + e $\rightarrow$M/TEX> 20H + H2.. Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure there by resulting to bad plating condition.

  • PDF

Oral Care Behavior according to Orthodontic Treatment Experience: Use of the 9th National Health and Nutrition Survey

  • Ho-Jin Jeong;Jung-Hwa Lee
    • Biomedical Science Letters
    • /
    • v.30 no.2
    • /
    • pp.81-85
    • /
    • 2024
  • Among all subjects who participated in the survey in the 9th 1st year (2022), 2,448 men (44.0%) and 3,166 women (56.0%) aged 12 or older were identified to determine oral care behavior according to orthodontic treatment experience. The purpose was to provide basic data on the oral care of patients wearing orthodontic appliances. 1. When it comes to brushing teeth, brushing before going to bed was the highest. Regarding the use of oral care products, 3,965 people (69.1%) said they 'do not use dental floss', 4,064 people (73.2%) said they 'do not use interdental brushes', and 4,064 people (73.2%) said they used oral rinse. 'I don't do it' was the highest at 4,417 (77.7%), and electric toothbrushes were the highest at 'I don't do it' at 5,241 (93.6%). 2. In terms of the effect of orthodontic treatment experience on toothbrushing time, with orthodontic treatment experience, toothbrushing after breakfast was 0.598 times more likely (P<0.001), and toothbrushing after lunch was 1.482 times more likely (P<0.001). Toothbrushing after dinner was 0.805 times higher (P=0.049), and toothbrushing before going to bed was 1.794 times higher (P<0.001), which was statistically significant. 3. When having orthodontic treatment experience, dental floss was found to be used 1.434 times more often (P=0.002), interdental brushes were used 1.464 times more times (P<0.001), and oral rinses were found to be used 1.457 times more times (P=0.002), which was statistically significant.

The micro-tensile bond strength of two-step self-etch adhesive to ground enamel with and without prior acid-etching (산부식 전처리에 따른 2단계 자가부식 접착제의 연마 법랑질에 대한 미세인장결합강도)

  • Kim, You-Lee;Kim, Jee-Hwan;Shim, June-Sung;Kim, Kwang-Mahn;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.148-156
    • /
    • 2008
  • Statement of problems: Self-etch adhesives exhibit some clinical benefits such as ease of manipulation and reduced technique-sensitivity. Nevertheless, some concern remains regarding the bonding effectiveness of self-etch adhesives to enamel, in particular when so-called 'mild' self-etch adhesives are employed. This study compared the microtensile bond strengths to ground enamel of the two-step self-etch adhesive Clearfil SE Bond (Kuraray) to the three-step etch-and- rinse adhesive Scotchbond Multi-Purpose (3M ESPE) and the one-step self-etch adhesive iBond (Heraeus Kulzer). Purpose: The purpose of this study was to determine the effect of a preceding phosphoric acid conditioning step on the bonding effectiveness of a two-step self-etch adhesive to ground enamel. Material and methods: The two-step self-etch adhesive Clearfil SE Bond non-etch group, Clearfil SE Bond etch group with prior 35% phosphoric acid etching, and the one-step self-etch adhesive iBond group were used as experimental groups. The three-step etch-and-rinse adhesive Scotchbond Multi-Purpose was used as a control group. The facial surfaces of bovine incisors were divided in four equal parts cruciformly, and randomly distributed into each group. The facial surface of each incisor was ground with 800-grit silicon carbide paper. Each adhesive group was applied according to the manufacturer's instructions to ground enamel, after which the surface was built up using Light-Core (Bisco). After storage in distilled water at $37^{\circ}C$ for 1 week, the restored teeth were sectioned into enamel beams approximately 0.8*0.8mm in cross section using a low speed precision diamond saw (TOPMET Metsaw-LS). After storage in distilled water at $37^{\circ}C$ for 1 month, 3 months, microtensile bond strength evaluations were performed using microspecimens. The microtensile bond strength (MPa) was derived by dividing the imposed force (N) at time of fracture by the bond area ($mm^2$). The mode of failure at the interface was determined with a microscope (Microscope-B nocular, Nikon). The data of microtensile bond strength were statistically analyzed using a one-way ANOVA, followed by Least Significant Difference Post Hoc Test at a significance level of 5%. Results: The mean microtensile bond strength after 1 month of storage showed no statistically significant difference between all adhesive groups (P>0.05). After 3 months of storage, adhesion to ground enamel of iBond was not significantly different from Clearfil SE Bond etch (P>>0.05), while Clearfil SE Bond non-etch and Scotchbond Multi-Purpose demonstrated significantly lower bond strengths (P<0.05), with no significant differences between the two adhesives. Conclusion: In this study the microtensile bond strength to ground enamel of two-step self-etch adhesive Clearfil SE Bond was not significantly different from three-step etch-and-rinse adhesive Scotchbond Multi-Purpose, and prior etching with 35% phosphoric acid significantly increased the bonding effectiveness of Clearfil SE Bond to enamel at 3 months.

Study of Spin Jig Development for Cleaning of the PCB component (PCB기판 세척용 스핀 지그개발에 관한 연구)

  • Lee, Seung-Chul;Park, Suk-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.4736-4741
    • /
    • 2014
  • This study examined PCB component cleaning on a PCB component surface, which has defects of precipitation type washing (existing rinse method), sealant and foreign material formed in the adhesive process that could not be removed easily. The spin jig was developed for PCB component cleaning, in which the PCB component settled down, to solve the conventional problem of the removal of foreign material with the centrifugal force by high speed rotation. The results are as follows. With decreasing fraction defect in PCB component washing, the development and substrate damage decreased by more than 80% according to the abstergent in the rotary type using the centrifugal force in the existing precipitation type. When the base plate showed a large difference with the time to include the process after washing the design using the existing method, easy attachment and separation of the PCB component could be possible. The washing time was enhanced 90% compared to the existing time. The reliability of the security and washing collaboration of the design and stability of the cleaning process could be secured so that there was no phenomenon of secession, the PCB component fixed for a cleansing rotation jig could maintain a fixed force by the centrifugal force. The stability and reliability of the washing process and the defective rate could be improved to less than 1%.