• Title/Summary/Keyword: rigid frame

Search Result 339, Processing Time 0.024 seconds

Dynamic response of a linear two d.o.f system visco-elastically coupled with a rigid block

  • Di Egidio, Angelo;Pagliaro, Stefano;Fabrizio, Cristiano;de Leo, Andrea M.
    • Coupled systems mechanics
    • /
    • v.8 no.4
    • /
    • pp.351-375
    • /
    • 2019
  • The present work investigates the use of a rigid rocking block as a tool to reduce vibrations in a frame structure. The study is based on a simplified model composed by a 2-DOF linear system, meant to represent a general M-DOF frame structure, coupled with a rocking rigid block through a linear visco-elastic device, which connects only the lower part of the 2-DOF system. The possibility to restrain the block directly to the ground, by means of a second visco-elastic device, is investigated as well. The dynamic response of the model under an harmonic base excitation is then analysed in order to evaluate the effectiveness of the coupling in reducing the displacements and the drift of the 2-DOF system. The nonlinear equations of motion of the coupled assemblage 2-DOF-block are obtained by a Lagrangian approach and then numerically integrated considering some reference mechanical and geometrical quantities as variable parameters. It follows an extensive parametric analysis, whose results are summarized through behaviour maps, which portray the ratio between the maximum displacements and drifts of the system, with and without the coupling with the rigid block, for several combinations of system's parameters. When the ratio of the displacements is less than unity, the coupling is considered effective. Results show that the presence of the rocking rigid block improves the dynamics of the system in large ranges of the characterizing parameters.

Seismic performance of mid-rise steel frames with semi-rigid connections having different moment capacity

  • Bayat, Mohammad;Zahrai, Seyed Mehdi
    • Steel and Composite Structures
    • /
    • v.25 no.1
    • /
    • pp.1-17
    • /
    • 2017
  • Seismic performance of hybrid steel frames defined as mixture of rigid and semi-rigid connections is investigated in this paper. Three frames with 10, 15 and 20 stories are designed with fully rigid connections and then with 4 patterns for semi-rigid connection placement, some of beam to column rigid connections would turn to semi-rigid. Each semi-rigid connection is considered with 4 different moment capacities and all rigid and semi-rigid frames consisting of 51 models are subjected to 5 selected earthquake records for nonlinear analysis. Maximum story drifts, roof acceleration and base shear are extracted for those 5 earthquake records and average values are obtained for each case. Based on numerical results for the proposed hybrid frames, story drifts remain in allowable range and the reductions in the maximum roof acceleration of 22, 29 and 25% and maximum base shear of 33, 31 and 54% occur in those 10, 15 and 20-story frames, respectively.

Development of a Rigid-ended Beam Element and Its Application to Simplify 3-Dimensional Analysis of Bracketed Frame Structures (강체 단부 보요소의 개발 및 브라켓이 있는 골조 구조의 3차원 해석 단순화를 위한 적용)

  • Seo, Seung Il;Lim, Seong Joon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.34 no.3
    • /
    • pp.76-84
    • /
    • 1997
  • At the initial design stage, for rapid evaluation of strength of ship structures, finite element analysis using beam elements is carried out in general. In beam modeling of ship structures, brackets are usually represented by rigid elements to simplify the analysis. Extent of rigid ends, which is called as a span point, can be determined from the three kinds of view points, i.e., bending, shearing and axial deformation. In this paper, a 2-dimensional novel beam element is developed and a method to replace the 3-dimensional analysis with 2-dimensional analysis is proposed. The developed novel beam element named rigid-ended beam element can consider the effect of three kinds of span points within one element, which was impossible in modeling with the ordinary beam element. Calculated results for the portal frame using the rigid-ended beam element agree with the results using membrane elements. And also, the proposed semi 3-dimensional analysis method which includes two step analysis using influence coefficients shows good accuracy. Structural analysis using the rigid-ended beam element and the semi 3-dimensional method is revealed to have good computing efficiency due to unnecessity of elements corresponding to the brackets and simplification of 3-dimensional analysis.

  • PDF

Structural Performance Evaluation of Reinforced Concrete Frame and Shear Wall with Various Hoop Ratios of Boundary Column (철근콘크리트 프레임 및 전단벽체의 경계기둥 띠철근비 변화에 따른 구조성능 평가)

  • 신종학;하기주;전찬목
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.6
    • /
    • pp.303-311
    • /
    • 1998
  • Ten reinforced concrete rigid frames and infilled shear wall frames were tested under both vertical and cyclic loadings. Experiments were carried out to evaluate the structural performance of such test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. under load reversals. All the specimens were modeledin one-third scale size. Based on the test results reported in this study, the follwing conclusions can be made. For the rigid frame type and the fully rigid babel type shear wall specimens, the hysteresis diagrams indicate that the degradations of their strength were developed slowly beyond maximum carrying capacity. It was shown that when the hoop reinforcement ratio became higher, the energy dissipation capacity became larger and the failure mode became ductile. The specimens designed by the less hoop reinforcement for the fully rigid babel type shear wall, were mainly failed due to diagonal crack in comparison with the specimens designed by the larger hoop reinforcement ratio. Maximum horizontal resisting moment capacity of speciment designed by the fully rigid babel shear wall were increased by 5.47~7.95 times in comparison with the rigid frame type.

Practical design guidlines for semi-continuous composite braced frames

  • Liew, J.Y. Richard;Looi, K.L.;Uy, Brian
    • Steel and Composite Structures
    • /
    • v.1 no.2
    • /
    • pp.213-230
    • /
    • 2001
  • This paper presents a simplified approach for the design of semi-continuous composite beams in braced frames, where specific attention is given to the effect of joint rotational stiffness. A simple composite beam model is proposed incorporating the effects of semi-rigid end connections and the nonprismatic properties of a 'cracked' steel-concrete beam. This beam model is extended to a sub-frame in which the restraining effects from the adjoining members are considered. Parametric studies are performed on several sub-frame models and the results are used to show that it is possible to correlate the amount of moment redistribution of semi-continuous beam within the sub-frame using an equivalent stiffness of the connection. Deflection equations are derived for semi-continuous composite beams subjected to various loading and parametric studies on beam vibrations are conducted. The proposed method may be applied using a simple computer or spreadsheet program.

Pushover analysis of gabled frames with semi-rigid connections

  • Shooshtari, Ahmad;Moghaddam, Sina Heyrani;Masoodi, Amir R.
    • Steel and Composite Structures
    • /
    • v.18 no.6
    • /
    • pp.1557-1568
    • /
    • 2015
  • The nonlinear static analysis of structure, which is under the effect of lateral loads and provides the capacity curve of the structure, is defined as a push-over analysis. Ordinarily, by using base shear and the lateral displacement of target point, the capacity curve is obtained. The speed and ease of results interpretation in this method is more than that of the NRHA responses. In this study, the nonlinear static analysis is applied on the semi-rigid steel gabled frames. It should be noted that the members of this structure are analyzed as a prismatic beam-column element in two states of semi-rigid connections and supports. The gabled frame is modeled in the OpenSees software and analyzed based on the displacement control at the target point. The lateral displacement results, calculated in the top level of columns, are reported. Furthermore, responses of the structure are obtained for various support conditions and the rigidity of nodal connections. Ultimately, the effect of semi-rigid connections and supports on the capacity and the performance point of the structure are presented in separated graphs.

The Structural Behavior of the Frames with Semi-Rigid Connections Using Reformed T-stubs (개량 T-stub를 이용한 반강접 골조의 거동)

  • Lee, Myung Jae;Cho, Won Hyuck
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.4 s.47
    • /
    • pp.339-350
    • /
    • 2000
  • The objective of this study is to investigate the structural behavior of the beam to column connection with reformed T-stubs and to ascertain the application of semi-rigid connection with reformed T-stubs to middle high rise buildings. The tests of steel frame using semi-rigid connections with reformed T-stub and existing T-stub were performed under cyclic loading condition. Finite element analysis was also carried out and the results of FEM were compared with results of tests. The thickness of reformed T-stub and the distance of bolt were used for parameters in the analysis. The structural behaviors of reformed T-stub were understood qualitatively and the possibility of application of semi-rigid connections with reformed T-stubs was ascertained.

  • PDF

A Study of Nonlinear Unstable Phenomenon of Framed Space Structures Considering Joint Rigidity (절점 강성을 고려한 공간 구조물의 비선형 불안정 거동에 관한 연구)

  • Shon, Su-Deok;Kim, Seung-Deog;Hwang, Kyung-Ju;Kang, Moon-Myung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.3 no.1 s.7
    • /
    • pp.87-97
    • /
    • 2003
  • The structural system that discreterized from continuous shells is frequently used to make a large space structures. As well these structures show the unstable phenomena when a load level over the limit load, and snap-through and bifurcation are most well known of it. For the collapse mechanism, rise-span ratio, element stiffness and load mode are main factor, which it give an effect to unstable behavior. In our real situation, most structures have semi-rigid joint that has middle characteristic between pin and rigid joint. So the knowledge of semi-rigid joint is very important problem of stable large space structure. And the instability phenemena of framed space structures show a strong non-linearity and very sensitive behavior according to the joint rigidity For this reason In this study, we are investigating to unstable problem of framed structure with semi-rigidity and to grasp the nonlinear instability behavior that make the fundamental collapse mechanism of the large space frame structures with semi-rigid joint, by proposed the numerical analysis method. Using the incremental stiffness matrix in chapter 2, we study instability of space structures.

  • PDF

An Analysis of the Airtightness Performance and Heating Energy Demand According to Building Structural Characteristics -Focused on Newly Apartment Houses- (건물 구조 특성에 따른 기밀성능 및 난방 에너지 요구량 분석 - 신축 공동주택 중심으로 -)

  • Lee, Su-In;Kim, Jeong-Gook;Kim, Seo-Hun;Kim, Jong-Hun;Jeong, Hak-Geun;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • Purpose: The importance of building airtightness is increased as the demand and expectation of building energy efficiency is growing. Previous research only focused on airtightness of building openings only to improve building airtightness. However, the analysis of difference of airtightness performance according to the characteristic of building structure has not been performed. Therefore, this study analyzed the difference of airtightness performance according to building structural characteristics in a number of ways. Method: Airtightness that are classified as rigid-frame type or wall type are measured and analyzed the difference of airtightness performance between rigid frame type apartments and wall type apartments. This study calculated the heating energy demand and quantitatively analysis using ISO 13790. Futhermore, this study compared research trend of domestic airtightness performance with airtightness standards of the developed countries based on the field measurement. Result: Airtight performance of wall type is better than rigid frame type in terms of energy saving. The difference of heating energy demand between wall type and rigid frame type was $8.14kWh/m^2yr$.

A Study on the Flexibility of Semi-Rigid Steel Frames under Lateral Loadings( II ) (횡하중을 받는 반강접 철골 골조의 유연도에 관한 연구( II ) -골조 해석모형을 중심으로-)

  • Kang, Cheol Kyu;Han, Young Cheol;Lee, Gab Jo
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.4 s.29
    • /
    • pp.121-131
    • /
    • 1996
  • Semi-rigid frames are frames for whcih the connections joining the beam and column are neither fully rigid nor perfectly pinned. In reality, all steel frames are semi-rigid in nature as all connections exhibit a certain degree of flexibility under loads. For semi-rigid frmaed structures, it is tended to reduce more rigidity of the member for the nonlinear behavior of connections and the P-delta effects of framed structure. To predict the actual behavior of semi-rigid steel frames, a more realistic analysis methods which explicitly takes into account the effect of connection flexibility should be used. In this research, the effect of connection flexibility in the semi-rigid structure has been investigated. To predict the response of flexibility connected frames, the algorithm of semi-rigid steel frame is developed using connection model having nonlinear spring on end of beam.

  • PDF