• Title/Summary/Keyword: rib-reinforcement

Search Result 59, Processing Time 0.03 seconds

Mechanical Behavior of Rib-reinforced Precast Cut-and-cover Tunnels by Large-sized Experiments

  • Gyuphil Lee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.10
    • /
    • pp.25-31
    • /
    • 2023
  • Wide tunnels,such as those with high filling, can suffer limited applicability and also reduced structural stability. Therefore, to improve these limitations of precast cut-and-cover tunnel segments, this study proposes rib reinforcement of the vaults of the precast segments. Large-sized experiments assess the effectiveness of the various rib-reinforced precast arch cut-and-cover tunnel structures, and compare them against otherwise similar non-rib-reinforced specimens. The results show that the rib-reinforced precast cut-and-cover segments are suitable for building wide tunnels with high filling.

A study on the effect of support structure of steel rib in partitioning excavation of tunnel (터널 상·하반 분할 굴착 시 강지보재 지지구조 효과에 대한 연구)

  • Kim, Ki-Hyun;Kim, Yeon-Deok;Hwang, Beoung-Hyeon;Choi, Yong-Kyu;Kim, Sang-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.5
    • /
    • pp.543-561
    • /
    • 2020
  • This paper is the result of the study on the effect of the support structure of the tunnel steel rib. In tunnel excavation, the top and bottom half excavation methods result in subsidence of steel rib reinforcement due to insufficient support of steel rib reinforcement when the ground is poor after excavation. The foundation of the steel rib installed in the upper half excavates the bottom part of the base, causing the subsidence to occur due to various effects such as internal load and lateral pressure. As a result, the tunnel is difficult to maintain and its safety is problematic. To solve these problems, steel rib support structures have been developed. For the purpose of verification, the behavior of the supporting structure is verified by model experiments reduced to shotcrete and steel rib material similarity, the numerical analysis of ΔP and ΔP generated by bottom excavation by Terzaghi theoretical equation. As a result, it was found that the support structure of 20.100~198.423 kN is required for the 10~40 m section of the depth for each soil of weathered soil~soft rock. In addition, as a result of the reduced model experiment, a fixed level of 50% steel rib deposit of steel rib support structure was installed. The study shows that the installation of steel rib support structures will compensate for uncertainties and various problems during construction. It is also thought that the installation of steel rib support structure will have many effects such as stability, economy, and air reduction.

A FEA Study on the Bond Property according to the Rib-Shape of Reinforcement (철근 마디형상에 따른 부착특성에 관한 해석적 연구)

  • Mihn, Joon-Soo;Hong, Geon-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.2
    • /
    • pp.38-46
    • /
    • 2014
  • Effects of various parameters on bond property between reinforcing bar and concrete are investigated in many researchers, and various study is on going to improve the bond strength. Properties of interface between reinforcement and concrete is important role in bond property. This study analyzed the interfacial bond mechanism between deformed bar and concrete by finite element analysis (FEA) to evaluate the effect of rib shape. The FEA model in this study is simplified 2D plane stress model. The variables of analysis are selected by rib angle, rib height, rib spacing and relative rib area. From the results of analysis, reinforcing bars with rib angle $30{\sim}60^{\circ}$ showed better bond strength than the others. Bond strength ratio following to the rib height is proportionally increased up to the $0.12d_b$, but rib spacing has little effect on bond strength. The results also indicated that relative rib area can be efficiently represented the properties of deformed shape in reinforcing bars, and zigzagged rib height shape showed excellent bond strength increase.

An Experiment Study of Cyclic Seismic Behavior of Steel Moment Connections Reinforced with Ribs (리브로 보강된 철골 모멘트 접합부의 내전거동에 관한 실험적 연구)

  • 이철호;이재광;정종현;오명호;구은숙
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.317-326
    • /
    • 2002
  • Recently a simple design method for rib-reinforced seismic steel moment connections has been proposed based on equivalent strut model. An experimental program was implemented to verify the proposed design method and to develop the schemes that will prevent the cracking at the rib tip, where stress concentration was evident. All the specimens designed by the proposed method were able to develop satisfactory connection plastic rotation of 0.04 radian. Slight beam flange trimming, in addition to rib reinforcement, pushed the plastic hinging and local buckling of the beam away from the rip tip and effectively reduced the cracking potential at the rib tip. The strut action of the rib and resulting reverse shear in the beam web were also experimentally identified through the strain gage readings.

  • PDF

An Analysis and Retrofit of U-rib Fatigue Cracks in the Steel Deck Bridge (강바닥판 교량의 U리브 피로균열 해석 및 보강)

  • Ryu, Duck-Yong;Jung, Hie-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.2
    • /
    • pp.176-183
    • /
    • 2010
  • In the steel deck box girder bridges, the deck is composed of deck plate, longitudinal and lateral direction ribs. The bridge, that is considered in this study, has been used for about 40 years and, recently, several cracks were found in the connection area of U-ribs. Further, additional cracks were occurred after some lateral rib plates and longitudinal frames were attached for the purpose of reinforcement. Therefore, the connection method in the U-ribs reinforcement was changed from the bolting to the weldment to get rid of stress concentration and further cracking. In this study, the stress in the U-ribs connection was analysed numerically and variable amplitude stress for the real traffic loads was measured experimentally before and after the frame reinforcement. Finally, the effects of reinforcement method were investigated and discussed.

A Study on Structural Analysis of Reinforced Longitudinal Rib in Orthotropic Steel Deck Bridge (보강된 세로리브에 의한 강바닥판교의 응력변화 연구)

  • Kong, Byung-Seung;Kim, Min-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.468-475
    • /
    • 2007
  • The Steel deck a structural analysis in head plate form change the objective bridge which it sells it accomplished a detailed structural analysis from the research which it sees and Bulk-head plate it accomplished. The length rib where the fatigue crack which is considerable generally occurs, width rib connection department and the length rib side, the width rib side it compares principal stress in the object and it does to sleep. It applied the grudge element model which it describes consequently after words and a load and a boundary condition and it executed it compared a static test and principal stress. It grasped the stress conduct of the The Steel deck petal which it follows in hand weaving rib affix location and the affix location to sleep in order to analyze a same location Bulk-head the head and comparison considered. From the detailed section which is reinforced with the stress investigation result hand weaving rib of the location which is weak in structural analysis result fatigue crack of form star reinforcement details basic form and Bulk-head the form which is reinforced with the head plate compared to principal stress investigation hour it is judged at the section which separates most.

  • PDF

Evaluate Bond Strength of High Relative Rib Area Bars (높은마디면적 철근의 부착 성능평가)

  • Yang Seung Yul;Seo Dong Min;Hong Gun Ho;Choi Oan Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.311-314
    • /
    • 2005
  • Bond between reinforcing bar and surrounding concrete is supposed to transfer load safely in the process of design of reinforced concrete structures. Bond failure of reinforcing bar generally take place by splitting of the concrete cover as bond force between concrete and reinforcing bars exceeds the confinement of the concrete cover and reinforcement. In this study, to evaluate bond strength of high relative rib area bars, beam-end bond and splice beam specimens are tested and the results are discussed. Higher rib height bars when bars are confined showed higher bond strength than lower rib height bars.

  • PDF

Evaluate Anchorage Strength of High Relative Rib Area Bars Using Hook Test Specimens (갈고리 시험체를 이용한 높은마디면적 철근의 정착성능)

  • Seo Dong Min;Hong Gi Suop;Choi Dong Uk;Choi Oan Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.327-330
    • /
    • 2005
  • Bond failure of reinforcing bar generally take place by splitting of the concrete cover as bond force between concrete and reinforcing bars exceeds the confinement of the concrete cover and reinforcement. However, the confinement force in practice has a limitation. Thus, the only variable is the bearing area corresponding to the change of bond force. In this study, to the evaluate anchorage strength of high relative rib area bars, hook bond test specimens are tested and the results are discussed. Higher rib height bars when bars are confined showed higher anchorage strength than lower rib higher bars.

  • PDF

ADINA/FSI Analysis of Petrochemical Plant Column Mixer (화학 플랜트용 칼럼 믹서의 ADINA/FSI 해석)

  • Lee, Won-Suk;Jung, Goo-Choong;Choi, Yeon-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.916-921
    • /
    • 2006
  • Column mixer is one of the facility to mix fluids at petrochemical plants. The column vibration is caused by pumps for fluid inflow and mixing of inside fluids. This fluid induced vibration is mainly responsible for the reduction of column life. Measurements were performed three times for understanding the vibration characteristics of the column. First experimental results showed the need of stiffness reinforcement. After the reinforcement work, second measurement conformed the difference between two results. Modal analysis was also performed to investigate the resonance of the column vibration and the damage of the rib plate. To confirm the generation of the fluid instability in the column mixer fluid structure interaction analysis using ADINA/FSI was performed which showed the necessity of the modification of the rotary valve.

  • PDF

ADINA/FSI Analysis of Petrochemical Plant Column Mixer (화학 플랜트용 칼럼믹서의 ADINA/FSI 해석)

  • Lee, Won-Suk;Jung, Goo-Choong;Choi, Yeon-Sun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.3 s.120
    • /
    • pp.213-219
    • /
    • 2007
  • Column mixer Is one of the facilities to mix fluids at petrochemical plants. The vibration of column mixer is usually caused by pumps for fluid inflow and mixing of inside fluids. This fluid induced nitration is mainly responsible for the reduction of column life. Measurements were performed for understanding the vibration characteristics of the column. First measurement results showed the need of stiffness reinforcement. After the reinforcement work, second measurement confirmed the difference between two results. Modal analysis was also performed to investigate the resonance of the column vibration and the damage of the rib plate. To confirm fluid induced vibration at the column mixer fluid structure interaction analysis using ADINA/FSI was performed, which showed the necessity of the modification of the rotary valve.