• 제목/요약/키워드: rhythm

검색결과 1,189건 처리시간 0.028초

망지 사단방법의 비교 (COMPARISON OF INDICATING NET SHAPING)

  • 고관서
    • 한국수산과학회지
    • /
    • 제1권2호
    • /
    • pp.129-133
    • /
    • 1968
  • The writer reviewed the cutting method of webbing practiced in major countries. Cutting rhythm Bar cutting to Point Cutting) should be chosen to approach as straight as possible, therefore the knot cuttings or the side cuttings should be 1, if possile. According to calculation, an arbitrary solution to a mixed cutting was undertaken, while another cutting method, of calculation 5 and 6, was taken by a prepared table. In no case, it was consequently possible to use an unmixed cutting rhythm. Sometimes, the cutting calculated from approximate value differs from desired result, tut this defference should not be taken too significant in practice.

  • PDF

폴리리듬 '7 against 3'에 대한 가상(假想)리듬 (Simulated Rhythm for Polyrhythm '7 against 3')

  • 김현종
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2010년도 춘계학술발표논문집 2부
    • /
    • pp.766-768
    • /
    • 2010
  • 폴리리듬 7 against 3 는 "기존의 3개의 동일한 길이의 음표가 진행하는 시간동안 7개의 동일한 길이의 음표가 동시에 연주되는 폴리리듬 이다"라고 간단히 설명할 수 있다. 이러한 폴리리듬 7 against 3를 실제로 연주하는 것은 쉽지 않다. 그러나 그 느낌이 어떠한 지는 본 연구에서 다루려고 하는 가상리듬을 통하여 알 수 있다. 본 연구에서는 7 against 3 에 대한 몇 가지 가상 리듬을 단계별로 제시하고 그 새로운 가능성에 대하여 생각해 보았다.

  • PDF

사용자 바이오리듬을 이용한 차량내 음악제공에 관한 연구 (A Study on Providing Music in Vehicle using User Bio-rhythm)

  • 용성중;김윤상
    • 디지털산업정보학회논문지
    • /
    • 제4권3호
    • /
    • pp.91-95
    • /
    • 2008
  • In this paper, a method for providing musics in vehicle user's bio-rhythm is proposed. The proposed method is a method to select and play musics automatically suitable for the user's emotion. Experimental results confirmed that the proposed method could provide better satisfaction to the users (drivers) compared to the methods given randomly.

개심술후 오버드라이브 심방페이싱(Over-drive atrial pacing)의 심방세동발생억제에 대한 연구 (Effects of Over-drive Pacing on the Suppression of Recurring the Atrial Fibrillation after open Heart Surgery)

  • 박영환
    • Journal of Chest Surgery
    • /
    • 제24권11호
    • /
    • pp.1081-1089
    • /
    • 1991
  • Atrial fibrillation is characterized by beat to beat irregularity of shape, size, conduction time and polarity. The mechanism of atrial fibrillation can be explained by so called "Multiple wavelet theory". The adverse effect of atrial fibrillation is the decrease of cardiac output by absence of atrial kick[10 ~ 15%] and the possibility of thrombosis in the left atrium which is dangerous to develop the thromboembolism is increased. The present study was designed to assess the effect of overdrive pacing on the suppression of recurring of atrial fibrillation after open heart surgery and the results were summarized as follows: 1. There were no significant differences of factors between converting patients and non-converting patients to normal sinus rhythm by electric cardioversion after open heart surgery. 2. Among converting patients to normal sinus rhythm, there were no significant differences of factors between study group and control group. 3. Cardiothoracic Ratio on the preoperative chest film was significantly larger in the patients of recurring atrial fibrillation within 72hrs than in the patients of maintaining normal sinus rhythm. [61.7$\pm$ 1.4% vs 67.7$\pm$2.4%, p=0.03] 4. There was a significant difference of suppressive effects between overdrive pacing group and control group among recurred cases until 24, 48, and 72hours [Fisher`s exact test ; p=0.037, p=0.076, p=0.53, respectively] 5. There was a difference of the delay of recurring of atrial fibrillation between study group and control group among recurred cases within 72 hours.[53.4$\pm$6.9hr vs. 19.3$\pm$3.8 hr, p<0.01] We think that the overdrive pacing may suppress the natural pacemaker and the converted normal sinus rhythm is maintained longer than control group during critical immediate postoperative period.ve period.

  • PDF

Effects of Morphine on Somatosyrnpathetic Reflex and Arterial Blood Pressure Response Evoked by Stimulation of Peripheral Nerves

  • Huh, Min-Gang;Yan, Hai-Dun;Lim, Won-Il;Kim, Jun
    • The Korean Journal of Physiology
    • /
    • 제29권2호
    • /
    • pp.309-321
    • /
    • 1995
  • In the present study, the relationship between the somatosympathetic reflexes and arterial blood pressure responses to electrical stimulation of the peripheral nerve was investigated in cats anesthetized with ${\alpha}-chloralose$. Single sympathetic postganglionic fiber activities were recorded from the hindlimb muscle and skin nerves and also from the cervical and abdominal sympathetic chains. Effects of the morphine on responses of the sympathetic nerve and arterial blood pressure to activation of the peripheral $A{\delta}-$ and C-afferent nerves were analyzed. The following results were obtained. 1) Arterial blood pressure was depressed by peripheral AS-afferent stimulation (A-response) and was elevated during C-afferent activation (C-response). 2) Intravenously administered morphine enhanced the C-response while the A-response decreased insignificantly, Only the C-response was decreased by intrathecal morphine. 3) All the ten recorded cutaneous sympathetic fibers showed periodic discharge pattern similar to respiratory rhythm and five of them also showed cardiac-related rhythm. However, most of the muscular sympathetic fibers had cardiac-related rhythm and only four fibers showed respiratory rhythm. 4) Morphine decreased the sympathetic C-reflex elicited by the peripheral C-afferent activation and the abdominal sympathetic A-reflex was also decreased by morphine. From the above results, it was concluded that supraspinal mechanisms were involved in the enhanced arterial pressor response to peripheral C-afferent activation by intravenous morphine.

  • PDF

LMS 적응필터를 이용한 직교 함수 기반의CPR 잡음 제거 알고리즘 설계 (Design of CPR Artifact Removal Algorithm Based on Orthogonal Function using LMS Adaptive Filter)

  • 임은호;남동훈;명현석;강동원;전대근;윤영로;이경중
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권5호
    • /
    • pp.153-160
    • /
    • 2016
  • This study proposes an algorithm for removal of CPR artifact in order that automated external defibrillator (AED) can effectively diagnose ECG rhythm during cardiopulmonary resuscitation (CPR). Current AED required to interrupt chest compression for reliable rhythm analysis to avoid the effect of artifacts produced by CPR. However even temporarily interruption of chest compression during CPR adversely affects the probability of restoration of spontaneous circulation (ROSC) and survival after the delivery of the shock. Therefore, we proposed a method for removal of CPR artifacts using least mean square (LMS) filter. The removal of the CPR artifacts would enable compressions to continue during AED rhythm analysis, thereby increasing the likelihood of resuscitation success. It was tested on 31 segments of shockable and 300 segments of non-shockable ECG signals recorded from three pigs during CPR. In the result, sensitivity (Se) and specificity (Sp) analysis on the test segments showed values of Se = 3.2%, Sp = 66.0% and Se = 96.8%, Sp = 98.7% in the case of unfiltered and filtered signals during CPR. In conclusion, it was shown that the proposed method can be a useful tool to exactly diagnose the ECG rhythm during the CPR.

뇌파측정을 이용한 비염 환아와 정상아의 주의집중력에 관한 연구 (The Study of Cognitive Function and EEG Spectrum Difference between Allergic Rhinitis and Normal Children)

  • 이남열;김윤희;한재경
    • 대한한방소아과학회지
    • /
    • 제21권2호
    • /
    • pp.1-12
    • /
    • 2007
  • Objectives : Allergic children have known to have multiple behavior problems. Among them, attentional ability disorder is one of the most common problems. This study is to examine relationship between learning ability and allergic rhinitis by analyzing EEG status of children. Methods : We analyzed cognitive functions of two different children groups; 21 children with allergic rhinitis and 19 normal children with CANS 3000(Central & Autonomic Nervous System, LAXTHA Inc., Korea), cognitive functions assessment program by EEG. Results : 1. According to mean active EEG rhythm of Theta, Alpha, SMR, M-beta, there were no significant difference between allergic rhinitis and the normal group. 2. According to mean active EEG rhythm of right H-beta, Gamma wave allergic rhinitis group's value was significantly higher than that of the normal group. 3. According to mean cognitive strength, response, concentration, left / right brain activity and learning ability score, there were no significant difference between allergic rhinitis and the normal group. 4. According to mean workload score, allergic rhinitis group's value was significantly higher than that of the normal group. Conclusions : It is likely that allergic rhinitis group, which showed relatively high frequency EEG rhythm, is more fragile to stress and less active on mental processing. Along side with physical examination, psychological assessment should also be conjugated on treating children with allergic rhinitis.

  • PDF

가용화 조성물과 난용성 약물군을 함유하는 고체분산체의 용출양상 (Dissolution Profiles of Solid Dispersions Containing Poorly Water-Soluble Drugs and Solubilizing Compositions)

  • 김태완;최춘영;;권경애;이범진
    • Journal of Pharmaceutical Investigation
    • /
    • 제32권3호
    • /
    • pp.191-197
    • /
    • 2002
  • Polymer based physical mixtures or solid dispersions containing solubilizing compositions[OA, tween80 and SLS] were prepared using a spray-dryer. Lovastatin(LOS), simvastatin(SIMS), aceclofenac(AFC) and cisapride(CSP) were selected as poorly water-soluble drugs. Dextrin, poly(vinylalcohol) (PVA), poly(vinylpyrrolidone)(PVP) and polyethylene glycol(PEG) were chosen as solubilizing carriers for solid dispersions. The solid dispersions containing solubilizing compositions without drug were prepared without using organic solvents or tedious changes of formulation compositions. This system could be used to quickly screen the dissolution profiles of poorly water-soluble drugs by simply mixing with drugs thereafter. In case of solid dispersion containing drug, organic solvent systems could be used to solubilize model drugs. The dissolution rates of the drugs were higher when mixed with drug and solid dispersions containing solubilizing compositions. However, solid dispersions of LOS, AFC, and CSP simultaneously containing drug and solubilizing compositions in organic solvent systems were more useful than physical mixtures of drug and solid dispersions without drug except SIMS. Based on solubilizing capability of polymer based physical mixtures in gelatin hard capsules, optimal solid dispersion system of poorly water-soluble drugs could be formulated. However, it should be noted that dissolution rate of poorly water-soluble drugs were highly dependent on drug properties, solubilizing compositions and polymeric carriers.

KCNQ1 S140G 돌연변이 발현과 심실세동과의 상관관계 분석을 위한 컴퓨터 시뮬레이션 연구 (Correlation Analysis of KCNQ1 S140G Mutation Expression and Ventricular Fibrillation: Computer Simulation Study)

  • 정다운;임기무
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권3호
    • /
    • pp.123-128
    • /
    • 2017
  • Background and aims: The KCNQ1 S140G mutation involved in $I_{ks}$ channel is a typical gene mutation affecting atrial fibrillation. However, despite the possibility that the S140G gene mutation may affect not only atrial but also ventricular action potential shape and ventricular responses, there is a lack of research on the relationship between this mutation and ventricular fibrillation. Therefore, in this study, we analyzed the correlation and the influence of the KCNQ1 S140G mutant gene on ventricular fibrillation through computer simulation studies. Method: This study simulated a 3-dimensional ventricular model of the wild type(WT) and the S140G mutant conditions. It was performed by dividing into normal sinus rhythm simulation and reentrant wave propagation simulation. For the sinus rhythm, a ventricular model with Purkinje fiber was used. For the reentrant propagation simulation, a ventricular model was used to confirm the occurrence of spiral wave using S1-S2 protocol. Results: The result showed that 41% shortening of action potential duration(APD) was observed due to augmented $I_{ks}$ current in S140G mutation group. The shortened APD contributed to reduce wavelength 39% in sinus rhythm simulation. The shortened wavelength in cardiac tissue allowed re-entrant circuits to form and increased the probability of sustaining ventricular fibrillation, while ventricular electrical propagation with normal wavelength(20.8 cm in wild type) are unlikely to initiate re-entry. Conclusion: In conclusion, KCNQ1 S140G mutation can reduce the threshold of the re-entrant wave substrate in ventricular cells, increasing the spatial vulnerability of tissue and the sensitivity of the fibrillation. That is, S140G mutation can induce ventricular fibrillation easily. It means that S140G mutant can increase the risk of arrhythmias such as cardiac arrest due to heart failure.

리듬분석과 비트매칭을 통한 조기심실수축(PVC) 검출 (The Detection of PVC based Rhythm Analysis and Beat Matching)

  • 전홍규;조익성;권혁숭
    • 한국정보통신학회논문지
    • /
    • 제13권11호
    • /
    • pp.2391-2398
    • /
    • 2009
  • 조기심실수축(Premature Ventricular Contractions, PVC)은 부정 맥 중 가장 빈번히 나타나는 심장질환으로 위험한 상황으로 발전할 가능성을 가지고 있다. 따라서 이의 검출은 심장질환에 대한 예방과 추후 발생여부에 대한 기초조사로서 매우 중요하다. 지금까지 PVC를 검출하는 많은 방법이 연구되어 왔으나 기존의 방법들은 잡음의 영향을 많이 받고 P파의 존재 유무에 의존적이기 때문에 검출의 정확도가 떨어지며, 처리시간이 많이 소요되기 때문에 실시간 검출에는 많은 어려움이 따른다. 이러한 문제점을 극복하기 위해 본 논문에서는 리듬분석과 비트매칭을 통한 PVC검출 방법을 제안한다. 이를 위해 전처리 과정 후 R 파를 검출하고, RR 간격의 리듬분석과 QRS 폭간격의 비트 매칭을 통해 비트 유형을 결정하는 알고리즘을 개발하였다. 제안한 알고리즘의 R파 및 PVC 검출 성능을 평가하기 위해 MIT-BIH 부정맥 데이터베이스를 사용하였다. 성능평가 결과, R파의 sensitivity는 99.74%, positive predictivity는 99.81%, PVC의 sensitivity는 93.91%, Positive predictivity는 96.48%의 검출 결과를 나타내었다.