Effects of Inoculated Bacillus subtilis on Geosmin and 2-Methylisoborneol Removal in Suspended Growth Reactors Using Aquacultural Waste for Biofloc Production

  • Luo, Guozhi;Wang, Jiao;Ma, Niannian;Liu, Zefeng;Tan, Hongxin
    • Journal of Microbiology and Biotechnology
    • /
    • 제26권8호
    • /
    • pp.1420-1427
    • /
    • 2016
  • Geosmin and 2-methylisoborneol (2-MIB) are two of the most common taint compounds that adversely affect the quality of aquacultural animals. In the present study, 94% of geosmin and 97% of 2-MIB in suspended growth reactors producing bioflocs (SGRs) with aquaculture waste were removed after inoculation with Bacillus subtilis, significantly higher than that of control SGRs (70% of geosmin and 86.4% of 2-MIB). The lowest concentrations of geosmin and 2-MIB achieved in the effluent of the SGRs were 2.43 ± 0.42 ng/l and 2.23 ± 0.15 ng/l, respectively. The crude protein content of the bioflocs produced in the SGRs was 35 ± 4%. The NH4+-N and NO2--N concentrations in the effluent of the reactors were 1.13 ± 0.21 mg/l and 0.42 ± 0.04 mg/l, respectively. These results suggest that inoculated with Bacillus subtilis, SGRs have a better performance to reuse the nitrogen in fish waste and to remove geosmin and 2-MIB from the culture water efficiently.

Feasibility Study of Agronomic Application of Treated Sewage for Paddy Rice Culture

  • Woo, Sun-Ho;Yoon, Chun-Gyeong
    • 한국환경농학회지
    • /
    • 제19권5호
    • /
    • pp.433-441
    • /
    • 2000
  • A feasibility study was performed to examine the agronomic application of treated sewage on paddy rice culture by field experiment for two consecutive years. The domestic sewage was treated by the constructed wetland system which was in subsurface flow type and consisted of sand and macrophyte. The effluent of the wetland system was used for irrigation water. The effluent was diluted to maintain the total nitrogen concentration below $26mg{\cdot}L^{-1}$ in the first year and used without dilution in the second year experiment. Growth components and yields were compared against the CONTROL plot where conventional method was applied. And also, soil characteristics of the plots before and after reclaimed sewage irrigation were analyzed. Generally, addition of the treated sewage to the irrigation water showed no adverse effects on paddy rice culture, and even enhancement was noticed in both growth and yield. Irrigation of treated sewage after concentration adjusted with conventional fertilization showed the better result, and the yield exceeded that of CONTROL case where clean water was irrigated. Soil characteristics changed after irrigation, and significant EC increasing was observed for the reclaimed sewage irrigation plots. From this study, it appears that reuse of treated sewage, as supplemental irrigation water could be a feasible and practical alternative. For full-scale application, further study is recommended on the specific guideline of major water quality components in treated sewage for irrigation and public health.

  • PDF

하수처리장 방류수의 UV 처리시 유기물질, 잔류염소 및 소독부산물 생성 거동 (Behavior of Organic Matter, Chlorine Residual and Disinfection By-Products (DBPs) Formation during UV Treatment of Wastewater Treatment Plant Effluents)

  • 한지희;손진식
    • 상하수도학회지
    • /
    • 제28권1호
    • /
    • pp.61-72
    • /
    • 2014
  • Study on effluent organic matter (EfOM) characteristic and removal efficiency is required, because EfOM is important in regard to the stability of effluents reuse, quality issues of artificial recharge and water conservation of aqueous system. UV technology is widely used in wastewater treatment. Many reports have been conducted on microbial disinfection and micro pollutant reduction with UV treatment. However, the study on EfOM with UV has limited because low/medium pressure UV lamp is not sufficient to affect refractory organics. The high intensity of pulsed UV would mineralize EfOM itself as well as change the characteristics of EfOM. Chlorine demand and DBPs formation is affected on the changed amounts and properties of EfOM. The objective of this study is to investigate the effect on EfOM, chlorine residual, and chlorinated DBPs formation with low pressure and pulsed UV treatment. The removal of organic matter through low pressure UV treatment is insignificant effect. Pulsed UV treatment effectively removes/transforms EfOM. As a result, the chlorine consumption is changed and chlorine DBPs formation is decreased. However, excessive UV treatment caused problems of increasing chlorine consumption and generating unknown by-products.

석유화학공장 방류수내 난분해성 유기물의 Fenton 산화처리 (Fenton난s Reagent Oxidation of Refractory Organics in Petrochemical Plant Effluent)

  • 이규훈;정대영;박태주
    • 한국환경과학회지
    • /
    • 제5권1호
    • /
    • pp.51-59
    • /
    • 1996
  • The purpose of this study was to evaluate the partial oxidation of the biological treatment plant effluents using Fenton's reagent as a pretreatment step prior to a tertiary biological oxidation of these effluents. Fenton's reagent was evaluated as a pretreatment process for inhibitory or refractory organics. Based on the Fenton oxidation system, the petrochemical wastewater treatment plant effluent was shown to have significant improvement in toxicity after oxidation with hydrogen peroxide. For example, at ranee of 42 ∼ 184 mg/L COD of petrochemical plant effluents, the COD removal efficiencies were from 38.2% to 60.1% after reaction with hydrogen peroxide 200 mg/L and Fe2+ 100 mg/L and reaction time was 30 minutes. The total TOC reduction were about 15.8∼22.4% with same test condition and difference between the overall removal rate and BOD/COD ratio after Fenton's oxidation estabilished in the biodegradation and otherwise meets the discharge standard or reuse for cooling tower make-up water.

  • PDF

수정된 MLE 공정을 이용한 Full-Scale에서의 돈사분뇨처리 (Piggery Waste Treatment using Improved MLE Process in Full-Scale)

  • 황인수;민경석
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.895-904
    • /
    • 2006
  • The improved MLE (modified Ludzack-Ettinger) process was operated for piggery waste treatment in full-scale public livestock waste treatment plant. The treated waste from bioreactor was suitable for the strict effluent standard of 200 mgCOD/L and 60 mgTN/L as it was dewatered chemically without settling tank and passed through filtration process. Though this treatment method produced a great deal of sludge ($6.4m^3\;per\;m^3$ dewatered piggery waste) it was able to accomplish predominant effluent quality by removing non-biodegradable COD and color without advanced oxidation process as ozone, fenton and etc.. The nitrogen removal efficiency of bioreactor was rapidly declined from March to May (from 0.016 to 0.005 kgN/kgVSS-day) when disinfection is in earnest as well as from warm season when reactor temperature rises higher than $35^{\circ}C$(from 0.016 to 0.008 kgN/kgVSS-day). This study proves that counterplanes for infection residuals, bioreactor temperature and dewatering sludge reduction are necessary for piggery waste treatment.

석유화학폐수 처리장 방류수의 재이용을 위한 고정생물막 공정에서 Fenton 산화전처리의 적응가능성 (Applicability of the lenten's Reagent Oxidation to Biological Fixed-Film Process for Reuse of Effluents from the Petrochemical Wastewster Effluent Treatment Plant)

  • 이규훈;김미화;박태주
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.115-115
    • /
    • 1995
  • Reuse of industrial effluents through the cooling systems in a petrochemical complex was described. The partial oxidation of the effluents from the biological treatment plant was examined, using Fenton''s reagent as a pretreatment step prior to a next treatment of the effluents. Next tertiary treatment using fixed-film reactor resulted in marked reductions in COD and suspended solids. The continuous fixed-film process with Fenton oxidation pretreatment showed a 23% increase in the COD removal efficiency when compared to that without pretreatment of Fenton oxidation under the volumetric organic loading rate of 0.1 kg COD/m3/day. The Fenton oxidation treatment seemed to be a possible method for tertiary biological treatment to reduce the residual toxicity with the enhanced biodegradation of the effluents.

석유화학폐수 처리장 방류수의 재이용을 위한 고정생물막 공정에서 Fenton 산화전처리의 적응가능성 (Applicability of the lenten류s Reagent Oxidation to Biological Fixed-Film Process for Reuse of Effluents from the Petrochemical Wastewster Effluent Treatment Plant)

  • 이규훈;김미화;박태주
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.501-508
    • /
    • 1995
  • Reuse of industrial effluents through the cooling systems in a petrochemical complex was described. The partial oxidation of the effluents from the biological treatment plant was examined, using Fenton's reagent as a pretreatment step prior to a next treatment of the effluents. Next tertiary treatment using fixed-film reactor resulted in marked reductions in COD and suspended solids. The continuous fixed-film process with Fenton oxidation pretreatment showed a 23% increase in the COD removal efficiency when compared to that without pretreatment of Fenton oxidation under the volumetric organic loading rate of 0.1 kg COD/m3/day. The Fenton oxidation treatment seemed to be a possible method for tertiary biological treatment to reduce the residual toxicity with the enhanced biodegradation of the effluents.

  • PDF

전기화학적 처리에 의한 배추 절임염수 재이용 가능성 평가 (Evaluation of brine reuse on salting of chinese cabbage using electrochemical process)

  • 정희숙;이은실;한성국;한응수
    • 상하수도학회지
    • /
    • 제28권5호
    • /
    • pp.541-548
    • /
    • 2014
  • The pickling brine generated from the salting process of kimchi production is difficult to treat biologically due to very high content of salt. When pickling brine is treated and discharged, it cannot satisfy the criteria for effluent water quality in clean areas, while resources such as the salt to be recycled and the industrial water are wasted. However, sterilization by ozone, UV and photocatalyst is expensive installation costs and operating costs when considering the small kimchi manufacturers. Therefore there is a need to develop economical process. The study was conducted on the sterilization efficiency of the pickling brine using electrochemical processing. The electrochemical treatment of organic matters has advantages over conventional methods such as active carbon absorption process, chemical oxidation, and biological treatment because the response speed is faster and it does not require expensive, harmful oxidizing agents. This study were performed to examine the possibility of electrochemical treatment for the efficient processing of pickling brine and evaluated the performance of residual chlorine for the microbial sterilization.

비료 유도용액의 정삼투를 이용한 하수처리수의 재이용 - 유도용액의 성능 평가 - (Water Reuse of Sewage Discharge Water Using Fertilizer Drawn Forward Osmosis - Evaluating the Performance of Draw Solution -)

  • 김승건;이호원
    • 멤브레인
    • /
    • 제26권2호
    • /
    • pp.108-115
    • /
    • 2016
  • 비료를 유도용액으로 사용하는 정삼투를 하수처리수(2차 침전지 유출수)의 재이용에 적용하여 유도용액의 성능을 평가하였다. 일반적으로 많이 사용되고 있는 비료 중에서 삼투압, 용해도 및 pH 등을 고려하여 $NH_4H_2PO_4$, KCl, $KNO_3$, $NH_4Cl$, $(NH_4)_2HPO_4$, $NH_4NO_3$, $NH_4HCO_3$$KHCO_3$을 유도용액 후보군으로 선정하고, 수투과선속 및 역용질선속을 측정하여 유도용액의 성능을 평가하였다. 평균 수투과선속은 KCl > $NH_4Cl$ > $NH_4NO_3$ > $KNO_3$ > $KHCO_3$ > $NH_4HCO_3$ > $NH_4H_2PO_4$ > $(NH_4)_2HPO_4$의 순서로 나타났으며, KCl을 유도용액으로 사용하였을 때, 평균 수투과선속은 13.49 LMH이었다. 하수처리장 2차 침전지 유출수의 삼투압은 탈이온수의 삼투압에 비해 큰 차이가 없었다. 역용질선속은 $NH_4H_2PO_4$ < $NH_4Cl$ < $(NH_4)_2HPO_4$ < $KNO_3$ < $NH_4HCO_3$ < $NH_4NO_3$의 순서로 나타났으며, $NH_4H_2PO_4$를 유도용액으로 사용하였을 때, 역용질선속은 $4.96{\times}10^{-3}mmol/m^2{\cdot}sec$이었다.

연탄재를 이용한 슬러지 저감 하수처리 연구 (Efficient Sewage Treatment with Less sludge Production by Used Briquets)

  • 정두영;정명희;송대용;김영준
    • 유기물자원화
    • /
    • 제16권2호
    • /
    • pp.81-87
    • /
    • 2008
  • 본 연구에서는 버려지는 연탄재를 하수처리에 이용하여 그 처리효율 및 활용성 등을 조사하였다. 본 연탄재 공법에 의해 처리된 처리수의 $BOD_5$, CODcr, SS 등은 각각 1.1 (mg/L), 9.5 (mg/L), 3.8(mg/L)를 나타내며 원수와 비교하여 99%, 92.7%, 96.3%의 처리효율을 보여주었다. 본 연탄재공법에 의한 처리수의 총 세균 및 대장균에 대한 제거효율은 각각 평균 9 (cfu/ml) 및 1.2 (cfu/ml)로 나타나 기존의 하수처리장 방류수와 비교하여 괄목할만한 감소효과를 보여주었다. 한편, 1년 이상의 장기적 운전실험에서는 변함없는 높은 처리효율의 유지와 함께 계절별 처리효율의 변동폭이 매우 낮았으며, 슬러지발생이 차단되는 효과를 보여주었다. 본 연탄재공법은 연탄재를 재활용함은 물론, 높은 처리효율과 슬러지의 발생을 감소시킴으로써 환경친화적인 공법이라 할 수 있으며, 중소규모의 하수처리 및 처리수의 재활용에 매우 유용할 것으로 사료되는 바이다.

  • PDF