• Title/Summary/Keyword: return loss

Search Result 1,073, Processing Time 0.036 seconds

A Case of Micturition Syncope in a Child (소아에서 발현한 배뇨 후 실신 1례)

  • Lee, Sun Youn;Ryu, Su Jeong;Kim, Deok Soo;Kim, Young Hwue;Ko, Tae Sung;Kim, Jae Moon
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.12
    • /
    • pp.1274-1278
    • /
    • 2003
  • Syncope in children and adolescents have a common occurrence according for up to 15% before adulthood. Micturition syncope, a kind of situational syncope, can be considered a form of reflex syncope. It can typically occur in healthy young men after rising from bed in the early morning who experience sudden loss of consciousness during or immediately after urination. The mechanism of micturition syncope is not completely understood, but it has been suggested that vasovagal reflex mediated bradycardia and peripheral vasodilation and decreased venous return due to Valsalva effect and standing position lead to the decrease in cerebral blood flow resulting in syncope. The causes of syncope are variable. So complete history taking, physical examination, electrocardiography, exercise stress test, echocardiography, head-up tilt table test, electroencephalography(EEG), brain magnetic resonance image and urodynamic study should be required for the diagnosis of micturition syncope. There were several reports about micturition syncope. However, literature of micturition syncope at the pediatric age has rarely been reported in Korea so far. Therefore, we report a case of a 9-year-old boy with micturition syncope with typical EEG findings of high amplitude delta wave and flattening during syncope.

Design of V-Band Waveguide Slot Sub-Array Antenna for Wireless Communication Back-haul (무선통신 백-홀용 V-밴드 도파관 슬롯 서브-배열 안테나의 설계)

  • Noh, Kwang-Hyun;Kang, Young-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.334-341
    • /
    • 2016
  • In this paper, the study of a waveguide aperture-coupled feed-structured antenna has been conducted for the purpose of applying it to a wireless back-haul system sufficient for high-capacity gigabits-per-second data rates. For this study, a $32{\times}32$ waveguide slot sub-array antenna with a corporate-feed structure was designed and produced. Also, this antenna is used at 57 GHz to 66 GHz in the V-band. The construction of the antenna is a laminated form with radiating parts (outer groove and slot, cavity), a coupled aperture, and feeds in each. The antenna was designed with HFSS, which is based on 3D-FEM, produced with aluminum processed by a precision-controlled milling machine, and assembled after a silver-plating process. The measurement result from analysis of the characteristics of the antenna shows that return loss is less than -12 dB, VSWR < 2.0, and a wide bandwidth ranges up to 16%. An overall first side lobe level is less than -12.3 dB, and a 3 dB beam width is narrow at about $1.85^{\circ}$. Also, antenna gain is 38.5 dBi, offering high efficiency exceeding 90%.

Advanced Design of Birdcage RF Coil for Various Absorption Regions at 3T MRI System

  • Lee, Jung-Woo;Choe, Bo-Young;Choi, Chi-Bong;Huh, Soon-Nyoung
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.9 no.1
    • /
    • pp.48-60
    • /
    • 2005
  • Purpose: The purpose of this study was to design and build an optimized birdcage resonator configuration with a low pass filter, which would facilitate the acquisition of high-resolution 3D-image of small animals at 3T MRI system. Methods and Materials: The birdcage resonator with 12-element structures was built, in order to ensure B1 homogeneity over the image volume and maximum filling factor, and hence to maximize the signal to noise ratio (SNR) and resolution of the 3-dimensional images. The diameter and length of each element of a birdcage resonator were as follows: (1) diameter 13 cm, length 22 cm, (2) diameter 15 cm, length 22 cm, (3) diameter 17 cm, length 25 cm. Spin echo pulse sequence and fast spin echo pulse sequence were employed in obtaining MR images. The quality of the manufactured birdcage resonators wes evaluated on the basis of the return loss following matching and tuning process. Results: The experimental MR image of phantoms by the various manufactured birdcage resonators were obtained to compare the SNR in accordance with the size of objects. The size of an object to that of coil was identified by parameters that were estimated from the image of a phantom. First, the diameter of the birdcage resonator was 15cm, and the ratio of the tangerine to the birdcage resonator accounted for approximately 27%. The Q factor was 53.2 and the SNR was 150.7. Second, at the same birdcage resonator, the ratio of the orange was approximately 53%. The SNR and the Q parameter was 212.8 and 91.2, respectively. Conclusion: The present study demonstrated that if birdcage resonators have the same forms, SNR could be different depending on the size of an object, especially when the size of an object to that of coil is approximately 40~80%, the former is bigger than the latter. Therefore, when the size of an object to be observed is smaller than that of coil, the coil should be manufactured in accordance with the size of an object in order to obtain much more excellent images.

  • PDF

A Study on the Design and Fabrication of a Dual-Ground and Broad-band Internal Antenna for 4th-Generation Mobile Communications (4세대 이동통신용 이중접지 내장형 광대역 안테나의 설계와 제작에 관한 연구)

  • Park, Jung-Ryul;Choi, Byoung-Ha;Kong, Jin-Woo;Yun, Hyun-Su;Kim, Gue-Chol
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.2
    • /
    • pp.100-108
    • /
    • 2008
  • In this paper, the dual-ground, high-gain and broad-band internal antenna has been designed and fabricated for 4th-generation mobile communication applications. The optimized antenna was fabricated using photolithography method. The antenna consist of the patches, antenna and system ground, and a probe. The patch and ground plane were separated by air. In order to prevent the demage due to radiator swaying, the foams(${\varepsilon}_r{\fallingdotseq}1.03$) were used to fix the patches and ground. The conductor for the radiators was 0.05 [mm] thick. The measured input return loss showed less than -10 [dB] at the broadband from 3499 to 4743 [MHz]. It's measured bandwidth was 1244 [MHz]. The radiation patterns measured at 3400, 3600, 3800, 4000 and 4200 [MHz] showed Omni-directional characteristics. The gain in the E-plane and H-plane was 4.7 ~ 6.1 and 2.1 ~ 4.3 [dBi], respectively.

  • PDF

Performance Evaluation of Hybrid Solar Air-Water Heater when the Heated Air is used as Inlet Air during Air and Water is Heated Simultaneously (가열 공기 유입에 따른 복합형 태양열 가열기 공기-물 제조 성능에 관한 연구)

  • Choi, Hwi-Ung;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.5
    • /
    • pp.21-29
    • /
    • 2015
  • In this study, the performance of hybrid solar air-water heater when the heated air was used as inlet air was investigated during air and liquid were heated simultaneously. Temperature difference between inlet air and ambient was set as $0^{\circ}C$, $13^{\circ}C$ and $22^{\circ}C$ and it was maintained during the daily operation. As a result, thermal efficiency of liquid heating was increased when the inlet air temperature was increased and heat gain of the water in heat storage tank was also increased with increment of temperature difference between inlet air and ambient temperature. On the contrary to this, the decrement of air heating efficiency and total efficiency of collector was confirmed with increment of inlet air temperature and it is considered that heat gain of liquid side is lower than heat loss of air side that occurring by using heated air as inlet air of collector. So, from these results, maximum temperature that the liquid in heat storage tank can reach was expected to increase if the return air or any heated air was used as inlet air. But air and total efficiency of hybrid solar air-water is decreased, so using outdoor air as inlet air is considered as better way on perspective of using of solar thermal energy by hybrid solar collector. However, it is hard to conclude that using outdoor air is better than heated air on the perspective of energy saving of building because the performance of heat storage performance was increased even air and total thermal efficiency was decreased, so the necessity of more profound consideration about these result in further research was confirmed for putting the hybrid solar air-water heater to practical use.

16-port Feed Waveguide Array for DBS Reception System Mounted on Vehicle (차량 탑재형 DBS 수신 시스템용 16 포트 급전 도파관 어레이)

  • Min, Gyeong-Sik;Kim, Dong-Cheol
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.2
    • /
    • pp.92-100
    • /
    • 2002
  • The 16-port feed waveguide array with inductive walls analyzed by Galerkin's method of moments are proposed for the DBS reception system mounted on vehicle. First of all, in order to verify the validity of electromagnetic analysis and design for a $\pi$-junction feed waveguide, it is designed and fabricated at DBS band. The measurement results of a $\pi$-junction feed waveguide agree well with the theoretical ones. Based on this design method, an array design for WR-90 standard waveguide is conducted. Since the width of a $\pi$-junction feed WR-90 standard waveguide is larger than a guided wave length in an array design, the difference of amplitude and phase of 8-port array are calculated 2.3 dB and 62 degrees, respectively. The bandwidth with return loss of -20 dB below is about 220 MHz and it doesn't satisfy DBS band. To solve this problem, we propose a novel design that the width of a $\pi$-junction feed waveguide equals to a guided wave length. By the proposed novel design for 8-port feed waveguide array, the difference of amplitude and phase are decreased 1 dB and 13 degrees, respectively. The broad bandwidth of 700 MHz is also realized. The size of 16-port waveguide away compared with WR-90 array is reduced about 10 cm. The measured antenna gain for the fabricated 16-port feed waveguide array is observed 24 dBi above at DBS band.

Fabrication and characterization of the 0.25 ${\mu}m$ T-shaped gate P-HEMT and its application for MMIC low noise amplifier (0.25 ${\mu}m$ T형 게이트 P-HEMT 제작 및 특성 평가와 MMIC 저잡음 증폭기에 응용)

  • Kim, Byung-Gyu;Kim, Young-Jin;Jeong, Yoon-Ha
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.1
    • /
    • pp.38-46
    • /
    • 1999
  • o.25${\mu}m$ T-shaped gate P-HEMT is fabricated and used for design of X0band three stage monolithic microwave integrated circuit(MMIC) low noise amplifier(LNA). The fabricated P-HEMT exhibits an extrinsis transconductance of 400mS/mm and a drain current of 400mA/mm. The RF and noise characteristics show that the current gain cut off frequency is 65GHz and minimum noise figure(NFmin) of 0.7dB with an associated gain of 14.8dB at 9GHz. In the design of the three stage LNA, we have used the inductive series feedback circuit topology with the short stub. The effects of series feedback to the noise figure, the gain, and the stability have been investigated to find the optimal short stub length. The designed three staage LNA showed a gain of above 33dB, a noise figure of under 1.2dB, and ainput/output return loss of under 15dB and 14dB, respectively. The results show that the fabricated P-HEMT is very suitable for a X-band LNA with high gain.

  • PDF

Analysis and Design Theory of Aperture-Coupled Cavity-Fed Back-to-Back Microstrip Directional Coupler (개구면 결합 공진기 급전 마이크로스트립 방향성결합기 해석 및 설계)

  • Nam, Sang-Ho;Jang, Guk-Hyun;Nam, Kyung-Min;Lee, Jang-Hwan;Kim, Chul-Un;Kim, Jeong-Phill
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.3 s.357
    • /
    • pp.7-17
    • /
    • 2007
  • An analysis and design theory of an aperture-coupled cavity-fed back-to-back microstrip directional coupler is presented for the efficient and optimized design. For this purpose, an equivalent network is developed, and simple but accurate calculations of circuit element values are described. Design equations of the coupler are derived based on the equivalent circuit. In order to determine various structural design parameters, the evolutionary hybrid optimization method based on the genetic algorithm and Nelder-Mead method is invoked. As a validation check of the proposed theory and optimized design method, a 10 dB directional coupler was designed and fabricated. The measured coupling was 10.3 dB at 3 GHz, and the return loss and isolation were 31.8 dB and 30.5 dB, respectively. The directional coupler also showed very good quadrature phase characteristics. Good agreements between the measured and the design specifications fully validate the proposed network analysis and design procedure.

Post Discharge Nursing Needs of Patients with Open Heart Surgery (개심술 환자의 퇴원후 간호요구에 대한 조사연구)

  • 김명희
    • Journal of Korean Academy of Nursing
    • /
    • v.23 no.4
    • /
    • pp.664-677
    • /
    • 1993
  • The purpose of this study was to provide basic data for the development of educational material in Korean for patient3 being discharge after open heart surgery. The subjects were 45 adult patients who were seen in the out -patient department of the thoracic surgery unit of P University hospital between February 1993 and May 1993. The data were collected through a chart review and interview. Nursing needs, and the patients status related to diet, activity, medication, physical and psychoemotional limitations were analyzed. The results are summarized as follows ; 1. Mitral valve replacement was the most frequent type of surgery(91.2%). In most cases, a mechanical valve was used (91.0%) . The duration of admission after the operation was two to four weeks for most of the patients(48.9%). The follow-up period was between one and two years for 28.9% of the patients and below 6 years for all of the patients. 2. Many Patients didn’t know the importance of a low salt diet(57.8%), and did not get any education on low salt diet (66.7%). Gimchi was included as one of the most commonly ingested foods (77.8%). All of the patients indicated nursing needs related to education about low salt diets and further they indicated a major interest in foods that are harmful (57.7%) or foods that are safe(51.1% ). 3. Most patients did not recognize the need for limitations on physical activity(84.4%). Further, 31.1% of them could not return to work at the time of the study. All patients had nursing needs related to physical activity, with the most frequent questions being about the permissble degree of activity and special cautions dictated by their illness (60.0%). 4. Many patients were ignorant of the necessity of medication(55.6%) . Forty percent of the patients were taking additional drugs, usually herb drugs. The time and duration of medication and the side effects of drugs were common concerns (57.7%) related to nursing. needs about medication and were mentioned by all of the patients. 5. All of the patients complained of physical discomfort including the following : memory disturbance(62.2%), weight gain(60.0%), chest tightness (55.6%), hair loss(51.1%), sleep disturbance(46.7%) and other symptoms in that order of frequency. Nursing needs related to physical condition were a concern for all of them. The viability and function of the replaced valve(53.3%) and weight gain(60.0%) were mal or concerns. 6. Looking at their psychoemotional condition it was found that 36 patients(80.0%) were emotionally unstable. The causes were physical discomfort(17 patients), insufficient knowlege of open heart surgery(6 patients), fear of death(6 patients), familial over protection(2 patients ) and lack of support (5 patients).

  • PDF

A Study on Securing a Stable GM for Each Ship Type Considering the Ship's Operating Status (선박의 운항 상태를 고려한 선종별 안정적인 GM 운용에 관한 연구)

  • Kim, Hong-Beom;Kim, Jong-Kwan;Lee, Yun-Sok
    • Journal of Navigation and Port Research
    • /
    • v.44 no.4
    • /
    • pp.275-282
    • /
    • 2020
  • Recently, the occurrence of a ship capsizing was analyzed as the main cause of the lack of stability or loss because of the improper management of the center of gravity, the movement of cargo or heavy weight when excessive steering occurs or when navigating during bad weather. Thus, to prevent a ship from capsizing, it is necessary to secure stability to enable the ship's return to its upright position, even if a dangerous heel occurs. The GM is a crucial evaluation factor regarding stability, which the navigation officer uses to preserve stability. In this study, based on the stability data collected from the operating of ships for five years, The GM by ship's type according to the operating status was analyzed specifically such as a ship's length, breadth, and gross tonnage. The feature of the GM distribution according to a ship's length was confirmed, and after performing the correlation analysis between the breadth and the GM, the ratio of the GM to breadth was calculated, and the result was compared with the previous ratio. Additionally, a simple approximation formula and minimum GM for the estimation of the GM by ship type were proposed by the regression analysis of the GM using the gross tonnage (GT)/breadth (B) to reflect the trend of larger ships being built. The results of this study are expected to be used as data for the review of securing a stable GM on ships.