• Title/Summary/Keyword: retrospective image

Search Result 123, Processing Time 0.026 seconds

A Study of the Concept of Futuristic Image in Fashion Since 2000 (2000년 이후 패션에 나타난 미래적 이미지의 개념에 관한 연구)

  • Kim, Yoon-Hee
    • Journal of the Korean Society of Costume
    • /
    • v.58 no.2
    • /
    • pp.107-119
    • /
    • 2008
  • This study aims to define the concept of the futuristic image in fashion since 2000. In this study, earlier studies of the futuristic images in the fashion are analyzed and it is discovered that the most important characteristics of the futuristic images are the cosmic space and virtual reality. An analysis of actual data of the futuristic images of the fashion since 2000 produces the following conclusions. First, since 2000 the futuristic fashion to convey the image of space tends to be minimalist, taking H or A silhouette and using white, silver, or other vivid colors. Second, since 2000 the image of virtual reality is often expressed in the fashion of futuristic image as female fighters or vampires of the future who mostly wear pants suit or skirts that expose the body line. Materials of advanced technology or shiny leather are often used and dark colors including black are dominant in these images. Third, when the space image is expressed, the androgynous youth is emphasized. However when female fighters or vampires of the future are shown, sexual image of gloomy atmosphere is often stressed. Fourth, the fashion of futuristic image since 2000 takes up the space age look of the 1960s and the techno-cyber look of the 1980s and the 1990s. However their internal meanings are lost and only external forms are repeated. In sum, the current fashion of futuristic image emulates the past look of the fashion which was circulated as futuristic images and may be considered as a result of combination of futuristic image and retrospective image.

Four-Dimensional Computed Tomography for Gated Radiotherapy: Retrospective Image Sorting and Evaluation

  • Lim, Sang-Wook;Park, Sung-Ho;Back, Geum-Mun;Ahn, Seung-Do;Shin, Seong-Soo;Lee, Sang-Wook;Kim, Jong-Hoon;Choi, Eun-Kyuong;Kwon, Soo-Il
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.71-74
    • /
    • 2005
  • To introduce the four-dimensional computed tomography (4DCT, Light Speed RT, General Electric, USA) scanner newly installed in our department and evaluate its feasibility for gated radiotherapy. Respiratory signal measured by real-time position management (RPM$^{\circledR}$, Varian Medical, USA) was recorded in synchronization with the 4DCT scanner. 4DCT data were acquired in axial cine mode and sorted retrospective image based on respiratory phase. PTVs delineated from helical CT and 4DCT images were compared. The PTV delineated from conventional helical CT images was 2 cc larger than that from 4DCT images. Dose in PTV of the plan from retrospective CT was 99.3% (minimum=72.0%, maximum=106.5%) and that of helical CT plan was 95.2% (minimum=24.1%, maximum=106.4%) of prescribed dose. Comparing with DVHs of both plan, the coverage for 4CDT plan was 3.7% improved. It is expected that 4DCT could improve tumor control and reduce radiation toxicity for liver cancer.

  • PDF

A Study on the Formative Feature Characteristics of Domestic Retrospective Fashion - focusing on 1990s - (국내 복고주의 패션의 조형성에 관한 연구 - 1990년대를 중심으로 -)

  • 최해주;안은경
    • Journal of the Korean Society of Costume
    • /
    • v.53 no.2
    • /
    • pp.137-151
    • /
    • 2003
  • Fashion photographs from leading monthly fashion magazines in 1990s were analyzed. The types and the formative feature characteristics and the aesthetic values of domestic retrospective fashion were studied. The major conclusions of the study are as follows 1. The types of domestic retro fashion were historicism, ethnic, ecology. Retro fashion was expressed through applying and reappearing silhouette, detail. fabric and image of the costumes of the past. 2. Renaissance. Baroque, Rococo styles and the costumes and styles of 1960s and 1970s were mainly applied in domestic fashion. 3. Orientalism was emphasized and Korean traditional styles and Chinese costumes were expressed mainly in domestic fashion. Fashion trends recurrent and intimate to the nature were expressed in patterns, fabrics, dyeing and silhouettes of nature. 4. The formative feature characteristics of domestic retro fashion were recurrence, purity. tradition and decoration. As retro fashion applies costumes of the past newly, it supplies unlimited possibilities to the present fashion which seeks versatility.

Development of Image Quality Measurement Method of Coronary Angiography Using Image Analysis Program (영상 분석 프로그램을 이용한 관상동맥 혈관 조영상의 화질 측정 방법 고안)

  • Seo, Young-Hyun;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.111-120
    • /
    • 2020
  • Research should be actively conducted for the ability of X-ray equipment and Retrospective image analysis of X-ray equipment used in hospitals. Retrospective image analysis of X-ray machines, CT and MRI of radiology and medical equipment has been actively conducted. However, image quality measurement using angiography equipment of angiography room is mostly measured with phantom, and image quality measurement on image after being taken by actual patient is insufficient and researches on accurate image quality measurement method are remarkable. It is in short supply. Therefore, through this study, the researcher devised a method to measure the image quality of the acquired image after coronary angiography, and to provide a high quality image to the operator. The equipment and programs used were angiographic examination equipment (Axiom Artis Zee Ceiling) and Image J program. Subjects were images automatically saved in PACS program after coronary angiography.For image quality measurement, selected the AP Caudal 30° image that show the LCA vessel well and the LAO 30° image that show the RCA vessel well during the coronary angiography. In order to measure the background and ROI of the selected image by selecting an image, a criterion on how to find and measure a section where the overlap of the shadow, such as blood vessel, liver and lung is minimized, is presented. In conclusion, there is no exact standard for analyzing an image quality measurement method of angiography image. Therefore, in order to provide quality images to the practistioners, not only the technicians of the equipment but also the users who actually use them should become researchers and conduct research on image quality measurement in various ways. Thus, it is expected to provide excellent images to patients.

An Estimate of Image Quality and Radiation Doses of Coronary Artery in MDCT Using Prospective and Retrospective ECG Gating Scan Mode (MDCT 관상동맥 조영 검사에서 전향적 동조화 및 후향적 동조화 기법의 화질과 선량 관계)

  • Oh, Jong-Kap
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.315-321
    • /
    • 2011
  • The goal of this study is to reduce patient exposure dose by providing image quality and radiation dose according to inspection methods. Volume Computed Tomography Dose Index(CTDIvol) and Dose Length Product(DLP) of prospective and retrospective ECG gating snapshot segment of Coronary CT angiography(CTA) were measured each snapshot segment methods. CT number, noise, uniformity, and resolution were also measured using phantom under the same condition of coronary CTA. The results showed that CT number, noise, uniformity and resolution are similar to each other. In terms of CTDIvol and DLP, however, measurement dose of prospective ECG gating snapshot segment was lower than the retrospective case by 37.5% and 40.3%. Therefore, it is highly recommended that in the coronary CTA, prospective ECG gating scan mode should be chosen to reduce patient dose.

Determination and classification of intraoral phosphor storage plate artifacts and errors

  • Deniz, Yesim;Kaya, Seher
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.219-228
    • /
    • 2019
  • Purpose: The aim of this study was to determine the reasons and solutions for intraoral phosphor storage plate (PSP) image artifacts and errors, and to develop an appropriate classification of the artifacts. Materials and Methods: This study involved the retrospective examination of 5,000 intraoral images that had been obtained using a phosphor plate system. Image artifacts were examined on the radiographs and classified according to possible causative factors. Results: Artifacts were observed in 1,822 of the 5,000 images. After examination of the images, the errors were divided into 6 groups based on their causes, as follows: images with operator errors, superposition of undesirable structures, ambient light errors, plate artifacts (physical deformations and contamination), scanner artifacts, and software artifacts. The groups were then re-examined and divided into 45 subheadings. Conclusion: Identification of image artifacts can help to improve the quality of the radiographic image and control the radiation dose. Knowledge of the basic physics and technology of PSP systems could aid to reduce the need for repeated radiography.

Image Quality and Lesion Detectability of Lower-Dose Abdominopelvic CT Obtained Using Deep Learning Image Reconstruction

  • June Park;Jaeseung Shin;In Kyung Min;Heejin Bae;Yeo-Eun Kim;Yong Eun Chung
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.402-412
    • /
    • 2022
  • Objective: To evaluate the image quality and lesion detectability of lower-dose CT (LDCT) of the abdomen and pelvis obtained using a deep learning image reconstruction (DLIR) algorithm compared with those of standard-dose CT (SDCT) images. Materials and Methods: This retrospective study included 123 patients (mean age ± standard deviation, 63 ± 11 years; male:female, 70:53) who underwent contrast-enhanced abdominopelvic LDCT between May and August 2020 and had prior SDCT obtained using the same CT scanner within a year. LDCT images were reconstructed with hybrid iterative reconstruction (h-IR) and DLIR at medium and high strengths (DLIR-M and DLIR-H), while SDCT images were reconstructed with h-IR. For quantitative image quality analysis, image noise, signal-to-noise ratio, and contrast-to-noise ratio were measured in the liver, muscle, and aorta. Among the three different LDCT reconstruction algorithms, the one showing the smallest difference in quantitative parameters from those of SDCT images was selected for qualitative image quality analysis and lesion detectability evaluation. For qualitative analysis, overall image quality, image noise, image sharpness, image texture, and lesion conspicuity were graded using a 5-point scale by two radiologists. Observer performance in focal liver lesion detection was evaluated by comparing the jackknife free-response receiver operating characteristic figures-of-merit (FOM). Results: LDCT (35.1% dose reduction compared with SDCT) images obtained using DLIR-M showed similar quantitative measures to those of SDCT with h-IR images. All qualitative parameters of LDCT with DLIR-M images but image texture were similar to or significantly better than those of SDCT with h-IR images. The lesion detectability on LDCT with DLIR-M images was not significantly different from that of SDCT with h-IR images (reader-averaged FOM, 0.887 vs. 0.874, respectively; p = 0.581). Conclusion: Overall image quality and detectability of focal liver lesions is preserved in contrast-enhanced abdominopelvic LDCT obtained with DLIR-M relative to those in SDCT with h-IR.

Magnetic Resonance Image Manifestations of the Atypical Meningioma

  • Wu, Qing-Wu;Yan, Rui-Fang;Li, Qiang;Hu, Ying;Zhou, Feng-Mei;Ren, Ji-Peng;Yang, Rui-Min;Zhang, Yan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6337-6340
    • /
    • 2013
  • Through retrospective analysis of 13 cases of magnetic resonance image (MRI) manifestations of atypical meningiomas confirmed by operation and pathology in the First Affiliated Hospital of Xinxiang Medical University, the objective of this study was to evaluate the diagnostic value of MRI in order to improve the accuracy rate of preoperative diagnosis. In this retrospective analysis of MRI findings for atypical meningiomas in First Affiliated Hospital of Xinxiang Medical University from January to July in 2012, the location, morphology and tumor signals and other tumor imaging characteristics were covered. In 13 cases of atypical meningioma patients of this group, most tumors were located at typical sites (10/13), mainly the falx cerebri, parasagittal, convexity, saddle area. Only two cases were at atypical locations, 1 in the cerebellar hemisphere and 1 in a lateral ventricle. Most of the tumors showed T1 and T2 isointensity signals, and necrosis, calcification, and peritumoral edema were always featured. DWI showed isointensity in 11 cases (11/13), and hyperintensity in 2. Some 9 cases had dural tail signs, 12 had accurate positioning (12/13), and 2 were postoperative recurrences. MRI has high value in the diagnosis of atypical meningiomas, with important roles in early clinical diagnosis, treatment and prognosis evaluation.

The Retrospective Study on the Correlation between the Multifidus Muscle Atrophy on Low Back Pain Patients and the Magnetic Resonance Images (자기공명영상 (Magnetic Resonance Image)을 통한 요통 환자의 다열근 위축에 대한 후향적 연구)

  • Lee, Kil-Joon;Park, Young-Hoi;Keum, Dong-Ho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.4
    • /
    • pp.151-163
    • /
    • 2009
  • Objectives : In the assessment of the lumbar spine by magnetic resonance imaging (hereinafter, "MRI"), changes in the paraspinal muscles are overlooked. The purpose of our study is to examine the correlation between the multifidus muscle atrophy on MRI findings and the clinical findings in low back pain (hereinafter, "LBP") patients. Methods : The retrospective study on 38 LBP patients, presenting either with or without associated leg pains, was undertaken. The MRI findings on the patients were visually analysed to find out a lumbar multifidus muscle atrophy, disc herniation, disc degeneration, spinal stenosis and nerve root compressions. The clinical history in each case was obtained from their case notes and pain drawing charts. Results : The lumbar multifidus muscle atrophy has occurred from more than 80% of the patients with LBP. Most of lumbar multifidus muscle atrophies have increased from lower level of lumbar spine. It was bilateral in the majority of the cases. In addition, multifidus muscle atrophy was correlated to the patient's age, disc degenerations and spinal stenosis. On the contrary, gender, the duration of LBP, referred leg pain, disc herniation and nerve root compressions had no relevance to multifidus muscle atrophies. Therefore, when assessing the MRIs of the lumbar spine, we should have more attetion on multifidus muscle, because it has lot's of information about spinal neuropathy problems. Conclusions : Therefore, the examination of multifidus muscle atrophies should be considered when assessing the MRIs of the lumbar spine. In addition, it helps to evaluate and plan the treatment modalities of LBP. Moreover, it prevents from LBP by discovering the importance between the multifidus muscle and the spine stabilization exercise.

Associated Lesions of Magnetic Resonance Image in the Chronic Lateral Ankle Instability (자기공명영상에서 나타난 만성 족근관절 외측 불안정성 동반 병변)

  • Lee, Ho-Jin;Chu, In-Tak;Choi, Kwang-Cheon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.1
    • /
    • pp.19-22
    • /
    • 2009
  • Purpose: This retrospective study was designed to determine the type and frequency of associated lesions in patients with chronic lateral ankle instability who had modified Brostrom lateral ankle ligament reconstruction. Materials and Methods: Between 2004 and 2007, 60 cases of 60 patients were enrolled in this study. A retrospective review of the magnetic resonance images of the affected ankle was conducted by two orthopedic surgeons who did not get any information about intraoperative findings and the lesions were admitted when two doctors were coincident. Results: The overall incidence of associated lesions found in this study was about 83%. Peroneal tenosynovitis was the highest frequency (32%), followed by osteochondral lesion of talus (28%), anterolateral impingement (15%), Os subfibula (13%), Os trigonum (12%), ankle synovitis (12%), anterior tibiofibular ligament tear (15%), anterior bony spur (7%). Another findings were loose bodies (5%), flexor tendon tenosynovitis (5%), medial osteophyte (3%). Conclusion: Identifying these associated lesions will be helpful in treating chronic lateral ankle instability especially when the surgeon have a plan to operate the instability. We suggest that the better results can be obtained when the associated lesions are corrected simultaneously.

  • PDF