• 제목/요약/키워드: retrofitted method

검색결과 148건 처리시간 0.023초

기존 골조의 내진성능 향상을 위한 철근콘크리트 현장타설 끼움벽의 보강성능 평가 (Evaluation on Seismic Performance of Existing Frame retrofitted with RC CIP Infill Walls)

  • 김선우;윤현도;김윤수;지상규
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.53-56
    • /
    • 2008
  • A reinforced concrete (RC) cast-in-place (CIP) infill wall retrofitting method may provide an improved seismic performance and economical efficiency for the non-ductile rahmen structures. In this study, four one story-one bay non-ductile frame were constructed and retrofitted with CIP infill wall to evaluate seismic performance of CIP infill wall-frame. From the test results, infill wall-frame exhibited a marked increase in shear strength compared to non-ductile RC frame specimen. But the ductility and story-drift at maximum load were decreased when shear strength of infill wall larger than that of existing RC frame. Therefore, it is confirmed that adequate reinforcement detail is required to assure sufficient seismic performance.

  • PDF

볼트조립식 CFT 내진보강공법에 관한 실험적 연구 (Experimental Study on the Bolt Assembly type CFT Seismic Reinforcement Construction Method)

  • 강수진;이동운;윤정배;김용기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.6-7
    • /
    • 2020
  • The government of South Korea enacted Earthquake Recovery Plan Act in 2008. In order to meet the requirement of this law, the important buildings, such as schools, public offices and so on, are in the process of seismic retrofit. This paper introduces the experimental data about a non-retrofitted concrete column and retrofitted column with a bolt assembly type CFT(concrete-filled steel tube).

  • PDF

내진보강용 폴리우레아로 보강된 철근콘크리트 기둥의 내진성능 평가에 대한 유사동적실험 연구 (Pseudo Dynamic Test Study on Seismic Performance Evaluation of RC Columns Retrofitted by PolyUrea)

  • 조철민;이두성;김태균;김장호
    • 대한토목학회논문집
    • /
    • 제37권2호
    • /
    • pp.289-301
    • /
    • 2017
  • 국내외적으로 지진의 발생이 빈번함에 따라 인명 및 재산 피해가 발생하고 추가적인 경제적 손실을 초래한다. 국내의 비내진으로 설계된 구조물의 보수 보강이 시급할 뿐만 아니라 지진에 대한 관심이 고조됨에 따라 내진보강에 대한 연구가 활발히 진행되고 있다. 최근 고연성 보강재를 사용한 내진보강기법이 소개되면서 강성보강보다는 연성보강에 대한 신뢰도가 높아지고 있다. 따라서 본 연구에서는 연성보강 재료로써 최근 각광받고 있는 폴리우레아를 이용한 내진보강공법을 소개하기 위해서, 폴리우레아로 보강한 RC 시편에 대하여 일축압축시험과 유사동적실험을 수행하였다. 일축압축시험에서 폴리우레아 보강시 강도가 증진되었을 뿐 아니라 연성거동을 확인할 수 있었으며, 실제 지진파를 적용한 유사동적실험에서는 상대변위, 주철근의 변형률, 변위연성도, 소산에너지 모두 향상된 보강성능을 확인할 수 있었다. 연성보강의 목적으로 개발한 폴리우레아 보강방법은 기둥부재의 내진보강에 유용하게 사용될 것이라고 판단된다.

GFRP 표면매립공법으로 보강된 RC보의 고온노출 후 휨 성능 (Flexural Performance of RC Beams Strengthened with NSM-GFRP Exposed to High Temperature)

  • 김희승;이혜학;최경규
    • 대한건축학회논문집:구조계
    • /
    • 제34권4호
    • /
    • pp.35-42
    • /
    • 2018
  • This study evaluated the fire resisting capacity and post-fire serviceability of the concrete beams retrofitted by near surface mounted method(NSM) using GFRP plates. Main parameters in the test are grout materials and fire exposure. For the test, two types of grout materials between concrete substrate and GFRP plate were used; flame resisting epoxy and filling mortar. Four RC beam specimens were made and two of them were exposed to fire according to real scale fire curve proposed KS F 2257. After the fire exposure test, flexural test were performed to investigate the flexural performance of concrete beams including strength and deformation. From the test results, it was found that the beam retrofitted by NSM-GFRP presented higher flexural strength than that of the beam without retrofit, which indicates NSM-GFRP retrofit technologies is effective to maintain flexural strength even after fire exposure. In addition, the specimens grouted by epoxy showed good performance in strength but bad performance in ductility.

FRP 판으로 표면매입 보강된 철근콘크리트 보의 보강성능 (Retrofit Capacity of Near-Surface-Mounted RC Beam by using FRP Plate)

  • 서수연;최기봉;권영순
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.18-26
    • /
    • 2012
  • 최근 FRP를 이용한 철근콘크리트 구조물의 보강방법으로서, 표면매입 보강 (Near-Surface-Mounted Retrofit, NSMR)방법의 연구가 활발히 진행되고 있다. 이 방법은 콘크리트에 홈을 형성하는 추가의 작업이 필요하지만 보강효과를 높일 수 있고 FRP가 표면에 노출되지 않기 때문에 환경의 영향을 저감시킬 수 있다. 본 연구에서는 이와 같은 표면매입 보강공법 즉, FRP판을 세워서 표면에 매입보강하는 공법의 보강효과를 실험적으로 규명하고자 하였다. 이를 위하여 철근콘크리트 보를 제작한 뒤 기존의 표면부착 보강과 표면매입 보강을 실시한 뒤 실험을 통하여 보강성능을 비교하였다. 또한 매입보강의 경우에는 중앙부를 부분적으로 비부착시켜 그 효과를 관찰하였다. 연구결과, FRP판을 이용한 철근콘크리트 부재의 휨보강방법으로서 FRP판을 세워서 표면에 매입하는 보강방법은 기존의 판 부착보강에 비하여 높은 보강성능을 발휘하는 것으로 나타났다. ACI 440-2R의 휨보강시 내력산정방법을 따르고 정착부분의 세가지 파괴형태를 고려함으로써 표면매입 보강된 부재의 내력을 평가할 수 있는 것으로 나타났다.

Earthquake-resistant rehabilitation of existing RC structures using high-strength steel fiber-reinforced concrete jackets

  • Kalogeropoulos, George I.;Tsonos, Alexander-Dimitrios G.;Konstantinidis, Dimitrios;Iakovidis, Pantelis E.
    • Earthquakes and Structures
    • /
    • 제17권1호
    • /
    • pp.115-129
    • /
    • 2019
  • The effectiveness of an innovative method for the earthquake-resistant rehabilitation of existing poorly detailed reinforced concrete (RC) structures is experimentally investigated herein. Eight column subassemblages were subjected to earthquake-type loading and their hysteretic behaviour was evaluated. Four of the specimens were identical and representative of columns found in RC structures designed in the 1950s-70s period for gravity load only. These original specimens were subjected to cyclic lateral deformations and developed brittle failure mechanisms. Three of the damaged specimens were subsequently retrofitted with innovative high-strength steel fiber-reinforced concrete (HSSFC) jackets. The main variables examined were the jacket width and the contribution of mesh steel reinforcement in the seismic performance of the enhanced columns. The influence of steel fiber volume fraction was also examined using test results of a previous work of Tsonos et al. (2017). The fourth earthquake damaged subassemblage was strengthened with a conventional RC jacket and was subjected to the same lateral displacement history as the other three retrofitted columns. The seismic behaviour of the subassemblages strengthened according to the proposed retrofit scheme was evaluated with respect to that of the original specimens and that of the column strengthened with the conventional RC jacket. Test results clearly demonstrated that the HSSFC jackets effectively prevented the development of shear failure mechanisms, while ensuring a ductile seismic response similar to that of the subassemblage retrofitted with the conventional RC jacket. Ultimately, an indisputable superiority in the overall seismic performance of the strengthened columns was achieved with respect to the original specimens.

Hysteresis performance of earthquake-damaged resilient RAC shear walls retrofitted with CFRP strips and steel plates

  • Jianwei Zhang;Siyuan Wang;Man Zhang;Yuping Sun;Hongwei Wang
    • Steel and Composite Structures
    • /
    • 제52권3호
    • /
    • pp.357-376
    • /
    • 2024
  • In this paper, weakly bonded ultra-high-strength steel bars (UHSS) were used as longitudinal reinforcement in recycled aggregate concrete shear walls to achieve resilient performance. The study evaluated the repairability and hysteresis performance of shear walls before and after retrofitting. Quasi-static tests were performed on recycled aggregate concrete (RAC) and steel fiber reinforced recycled aggregate concrete (FRAC) shear walls to investigate the reparability of resilient shear walls when loaded to 1% drift ratio. Results showed that shear walls exhibited drift-hardening properties. The maximum residual drift ratio and residual crack width at 1% drift ratio were 0.107% and 0.01mm, respectively, which were within the repairable limits. Subsequently, shear walls were retrofitted with bonded X-shaped CFRP strips and steel plates wrapped at the bottom and retested. Except for a slight reduction in initial stiffness, earthquake-damaged resilient shear walls retrofitted with a composite method still had satisfactory hysteresis performance. A revised damage assessment index D, has been proposed to assess of damage degree. Moreover, finite-element analysis for the shear wall before and after retrofit retrofitting was established in OpenSees and verified with experimental results. The finite element results and test results were in good agreement. Finally, parametric analysis was performed.

그라우팅이 필요 없는 RC기둥 강판보강 기법 (Steel Jacketing Method without Grouting for RC Columns)

  • 최은수;조성철;정영수;조백순
    • 한국강구조학회 논문집
    • /
    • 제20권1호
    • /
    • pp.55-65
    • /
    • 2008
  • 본 연구에서는 주철근의 겹침이음으로 인해 효과적인 내진성능을 충분히 확보하지 못한 RC기둥 보강 기법의 개발을 위해 횡방향외부압력을 도입한 강판으로 RC기둥을 보강하는 기법을 제시하였다. 제시된 기법의 성능 검증을 위해 설계강도를 변수로 하여 콘크리트 공시체 45개를 제작하여 외부압력을 도입하여 강자켓으로 보강하였다. 본 연구에서 소개하는 강자켓팅 기법은 기존의 방법과 달리 강판과 콘크리트 사이에 그라우팅이 필요 없는 기법이다. 보강된 시편과 무보강 시편의 압축실험을 수행하여 각각의 결과를 비교, 분석하였 다. 본 연구를 통해 횡방향 외부압력을 도입한 강판보강은 콘크리트 시편의 강도 및 연성도 증가에 매우효과적인 것으로 나타났고 설계강도가 낮은 시편에서 강도증가현상이 두드러지게 나타났다. 두꺼운 강판은 더 큰 강도 증진효과가 있었다. 본 연구에서는 제시한 보강기법은 RC기둥에 적용하여 강도 및 연성도을 증진시키는 효과가 있을 것으로 기대된다.

FRP로 보강한 비보강 조적 벽체의 전단강도 산정 (Evaluation of Shear Strength of Unreinforced Masonry Walls Retrofitted by Fiber Reinforced Polymer Sheet)

  • 배백일;윤효진;최창식;최현기
    • 콘크리트학회논문집
    • /
    • 제24권3호
    • /
    • pp.305-313
    • /
    • 2012
  • 비보강 조적조 건축물은 전세계적으로 기존의 건물 및 역사 건축물의 많은 부분을 차지하고 있다. 특히, 최근 지진이 전세계적으로 빈번하게 나타남에 따라 비보강 조적조 구조물에 대한 내진 보강 대책이 요구되고 있다. 현재 비보강 조적조의 보강방법으로는 숏크리트, ECC jacketing, FRPs(fiber reinforced polymer sheet) 등이 개발되어 사용되고 있다. 특히 많은 엔지니어들이 FRPs를 사용한 보강방법을 채택하는 경향이 보이는데 이는 숏크리트나 ECC jacketing과는 달리 벽체의 두께 확장에 따른 구조물 자중 증가 문제없이 비보강 조적조의 전단강도를 향상시킬 수 있기 때문이다. 그러나 비보강 조적 벽체의 복잡한 역학적 거동과 FRPs를 사용한 실험 데이터의 부족은 아직까지도 적절한 보강량을 산정하는데 어려움을 주고 있다. 이 연구는 비보강 조적조의 면내 거동을 확인하고 두 가지의 다른 특징을 가진 FRPs를 사용한 보강 효과에 대한 정보를 주기 위해 수행되었다. 실험체는 1970년대 한국에서 빈번하게 지어진 저층형 연립주택의 내벽을 대상으로 하고 있으며 별도의 내진 설계는 되어있지 않은 상태이다. 실험체의 형상비는 실제 상황을 반영하기 위해 1에 가깝게 설정되어 있다. 보강 재료로는 탄소섬유보강 시트와 하이브리드 시트를 사용하였으며 이들은 각각 다른 극한 강도와 탄성계수 및 극한 변형률을 보유하고 있다. 연구 결과 비보강 조적 벽체의 면내 전단력 저항 성능을 확인하였으며 FRPs가 사용된 내진 보강 방안의 특성을 분석할 수 있었다. 또한 FRPs를 사용한 보의 전단보강 방법에 착안하여 비보강 조적조에 대한 FRPs의 보강 설계안을 도출할 수 있었다.

세로리브 내부 보강상세에 따른 강바닥판 연결부의 피로거동 특성에 관한 해석적 연구 (Analytical Study on the Characteristic of Fatigue Behavior in Connection Parts of Orthotropic Steel Decks with Retrofitted Structural Details in Longitudinal Rib)

  • 선창원;박경진;경갑수;김교훈
    • 한국강구조학회 논문집
    • /
    • 제20권1호
    • /
    • pp.105-119
    • /
    • 2008
  • 윤하중을 직접 받는 강바닥판교는 공용연수 증가에 따라 세로리브와 가로리브 교차부 주위 등의 구조상세 등에서 피로 균열발생 사례가 증가하고 있는데, 이러한 피로균열 억제방안으로는 바닥강판의 두께를 증가시키거나 세로리브 내부에 보강상세 적용 등이 효율적인 것으로 보고되고 있다. 본 연구에서는 기존 연구에서 피로균열 발생이 빈번히 보고되고 있는 가로리브와 세로리브 연결부, 세로리브 및 가로리브 슬릿부를 대상으로 세로리브의 무보강상세 및 보강상세에 대한 구조해석을 수행하여 피로강도 향상을 위한 구조상세를 제안하고자 한다. 해석에서는 세로리브내의 벌크헤드 및 수직리브를 대상으로 형상 및 크기 변화, 부착위치를 변수로 하여 상세 구조해석을 수행하였다. 해석 결 과 보강상세가 있는 경우가 대상 구조상세부에서의 응력감소가 더 크며, 벌크헤드 상세보다는 수직리브 보강상세에서 피로강도 향상이 더 효율적인 것으로 나타났다.