• 제목/요약/키워드: retainer

검색결과 138건 처리시간 0.026초

Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems

  • Song, Tae-Jin;Kwon, Taek-Ka;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.219-225
    • /
    • 2013
  • PURPOSE. Few studies have investigated the marginal accuracy of 3-unit zirconia fixed partial dentures (FPDs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) system. The purpose of this study was to compare the marginal fit of zirconia FPDs made using two CAD/CAM systems with that of metal-ceramic FPDs. MATERIALS AND METHODS. Artificial resin maxillary central and lateral incisors were prepared for 3-unit FPDs and fixed in yellow stone. This model was duplicated to epoxy resin die. On the resin die, 15 three-unit FPDs were fabricated per group (45 in total): Group A, zirconia 3-unit FPDs made with the Everest system; Group B, zirconia 3-unit FPDs made with the Lava system; and Group C, metal-ceramic 3-unit FPDs. They were cemented to resin dies with resin cement. After removal of pontic, each retainer was separated and observed under a microscope (Presize 440C). Marginal gaps of experimental groups were analyzed using one-way ANOVA and Duncan test. RESULTS. Mean marginal gaps of 3-unit FPDs were $60.46{\mu}m$ for the Everest group, $78.71{\mu}m$ for the Lava group, and $81.32{\mu}m$ for the metal-ceramic group. The Everest group demonstrated significantly smaller marginal gap than the Lava and the metal-ceramic groups (P<.05). The marginal gap did not significantly differ between the Lava and the metal-ceramic groups (P>.05). CONCLUSION. The marginal gaps of anterior 3-unit zirconia FPD differed according to CAD/CAM systems, but still fell within clinically acceptable ranges compared with conventional metal-ceramic restoration.

Attachment를 이용한 후방연장 국소의치에 의한 압력분산에 관한 3차원 유한요소분석 (A THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS ON THE FORCE DISTRIBUTION BY DISTAL EXTENSION PARTIAL DENTURES EMPLOYING ATTACHMENTS)

  • 신상완;안원준;정연진;이영수;심광섭;유광희
    • 대한치과보철학회지
    • /
    • 제36권6호
    • /
    • pp.878-887
    • /
    • 1998
  • Although attachments have been utilized for a retainer of removable prostheses during several decades, there is little information on the force distribution by the attachments. This study was undertaken to evaluate the stress patterns developed by partial dentures employing rigid attachments on the supporting structures. Four types of the mandibular removable partial dentures were designed depending upon the position of the rigid attachment and the existency of lingual bracing. Under 100N of vertical and 25N of lateral loads on the 1st and 2nd lower molar of partial denture, stress distribution patterns and displacement were analysed with three dimensional finite element method by ANSYS version 5.3. 1. The highest stresses were concentrated on the distal alveolar crest of posterior abutment and the second stresses on the apical region of posterior abutment in the models. 2. The greatest displacement were shown on the distal alveolar crest of posterior abutment and the second displacement on the distal alveolar crest of anterior abutment in the models. 3. There was little difference between the models with intraoral attachment and those with extracoronal attachment. 4. There was little difference between the models with and without the lingual bracing.

  • PDF

The effect of bonded resin surface area on the detachment force of lingual bonded fixed retainers: An in vitro study

  • Lee, Il-Hong;Lee, Jung-Hwan;Park, In-Young;Kim, Ji-Hyun;Ahn, Jang-Hoon
    • 대한치과교정학회지
    • /
    • 제44권1호
    • /
    • pp.20-27
    • /
    • 2014
  • Objective: The aims of this study were to evaluate the relationship between the detachment force and bonding resin surface are and to determine the resin bonding surface area that would provide adequate bonding strength with minimum resin volume. Methods: One hundred and sixty human premolars were randomly divided into 4 groups of 40 teeth each. The diameter of the resin surface area in each group was as follows: group 1, 1.5 mm; group 2, 2.5 mm; group 3, 3.5 mm; and group 4, 4.5 mm. Respond Dead Soft straight (length 0.0175 inch) was used to fabricate the retainers, and $Transbond^{TM}$ XT was used to fix the retainers to the tooth surfaces. A pair of teeth was embedded in acrylic blocks for each specimen. Thus, each group comprised 20 samples. Fixed retainers were bonded to the teeth, and vertical force was applied at the middle of wire. The force was measured using a universal testing machine. Results: The mean value of detachment force was the highest for group 4 ($102.38{\pm}2.92N$), followed by group 3 ($63.54{\pm}2.21N$), group 2 ($51.95{\pm}1.61N$), and group 1 ($24.14{\pm}1.38N$). Conclusions: The detachment force of lingual fixed retainers was significantly affected as the area of the resin bonding surface increased. Considering the minimum bonding strength of brackets, a resin bonding surface area with a diameter of 3.5 mm would provide adequate bonding strength.

Comparison between fiber-reinforced polymers and stainless steel orthodontic retainers

  • Lucchese, Alessandra;Manuelli, Maurizio;Ciuffreda, Claudio;Albertini, Paolo;Gherlone, Enrico;Perillo, Letizia
    • 대한치과교정학회지
    • /
    • 제48권2호
    • /
    • pp.107-112
    • /
    • 2018
  • Objective: The aim of this study was to examine the properties of fiber-reinforced composite and stainless steel twisted retainers for orthodontic retention. Methods: Three different span lengths (5.0, 8.0, and 14.0 mm) of fiber-reinforced composite were investigated. The three fiber-reinforced composite retainer groups were subdivided according to the storage condition (dry and wet), resulting in a total of six groups. Each stainless steel and fiber-reinforced composite group was comprised of six specimens. The three-point bending flexural test was conducted using a universal testing machine. ANOVA was used to assess differences in the maximum load and maximum stress according to the span length, material, and storage condition. Post-hoc comparisons were performed if necessary. Results: The maximum stress and maximum load were significantly (p < 0.001) associated with the span length, material, and storage condition. The significant interaction between the material and span length (p < 0.001) indicated the differential effects of the material for each span length on the maximum stress and maximum load, with the difference between materials being the highest for the maximum span length. Conclusions: Our findings suggest that fiber-reinforced composite retainers may be an effective alternative for orthodontic retention in patients with esthetic concerns or allergy to conventional stainless steel wires.

17세기 초 홑철릭 유물의 시대특성과 유아형 인형의 체형특성을 응용한 단계별 복식문화상품 디자인 연구 (A Study on the Phased Cultural Product Design with Characteristics of Unlined Cheollik in Early 17th Century and Baby Typed Doll's Body)

  • 최정
    • 한국의류산업학회지
    • /
    • 제19권4호
    • /
    • pp.385-399
    • /
    • 2017
  • This study will broaden the application of doll costume product with historical characteristics and the image of unlined cheollik in the $17^{th}$ century period of transition during the Joseon Dynasty. Historical design sources were extracted from old documents and precedent studies. Unlined cheollik of Shin Gyeong-yu, meritorious retainer, were selected as main reference-relic because of various fabric, preserved conditions and definite shape. 'Baby doll' was selected as main model because of consumer preferences and awareness. Design sources from unlined cheollik in the early $17^{th}$ century were about a 1:2 ratio of upper and under parts, removable separated doori-somae, knife-shaped collar (outside), projected square collar (inside), long pleats line, side slit, traditional flat fell seam sewing. Trapezoidal side line, round waistline, and thin fabric were applied in designs because of toddler-body of doll model. Three designs were produced in step 1: Cheollik A focusing on the historical remake (traditional type), Cheollik B with belt and side slit (crossover type), and Cheollik C with back- opening (modern type). In step 2, interview with fashion major student was conducted to increase the utility of designs. As a result, modern trend sources (frill, velcro, round armhole line, slope of sleeves, and floral pattern) were reflected in Cheollik B, C. Finally, three doll cheollik and cheollik-styled doll apron sample were produced. Various versions must be suggested in the study of doll costume products with traditional sources that balance historical characteristics and practicality to improve customer satisfaction.

탄소/탄소 브레이크 디스크의 열탄성 해석과 3차원 응력해석 및 설계 (Thermo-Elastic Analysis, 3-Dimensional Stress Analysis and Design of Carbon/Carbon Brake Disk)

  • 오세희;유재석;김천곤;홍창선;김광수
    • Composites Research
    • /
    • 제15권1호
    • /
    • pp.41-52
    • /
    • 2002
  • 이 논문에서는 탄소/탄소 브레이크 제동중 시스템의 거동을 열탄성 해석을 수행하여 살펴보았고. 파손에 안정적인 디스크의 형상을 찾기 위하여 다양한 형상에 대한 3차원 응력해석을 수행하였다. 탄소/탄소 복합재료의 기계적 물성치가 적층면방향과 두께방향으로 측정되었다. 측정긴 기계적 물성치는 열탄성 해석과 3차원 응력해석을 위한 입력으로 사용 되었다. 로터 클립과 클립 리테이너 사이의 간격은 회전판의 하중전달 미케니즘에 있어서 중요만 인자이다. 간격변화는 기계적 변형과 열 변형으로 분리하여 고려하였다. 클립과 리테이터는 서로 접촉이 발생하지 않았으므로 해석 모델에서 리테이너와 리벳은 제외되었다. 로터 디스크는 반복대칭조건을 사용하여 모델링되었고, 로터 디스크와 로터 클립, 로터 클립과 키 드럼사이의 2중 접촉문제가 고려되었다. 3차인 응력해석의 결과로부터 브레이크 디스크의 키 홀 부분에 응력집중현상이 발생하는 것을 확인하였다. 응력분포는 키 홀 부분에서 접촉면의 회전각과 곡률반경의 변화에 따라 연구 되었다.

유지형태와 접착제 종류에 따른 수지 접착형 수복물과 법랑질간의 전단결합강도 및 파절양상에 관한 연구 (A STUDY ON THE SHEAR BOND STRENGTH BETWEEN RESIN-BONDED RETAINERS AND ENAMEL ACCORDING TO THE ADHESIVE RESINS AND RETENTION TYPES)

  • 조미숙;양재호
    • 대한치과보철학회지
    • /
    • 제33권4호
    • /
    • pp.662-684
    • /
    • 1995
  • The purpose of this study was to evaluate the shear bond strength between various resin-bonded retainers and enamel according to the adhesive resins and retention types and observe the bond filure modes with scanning electron microscope(SEM). For this purpose, the followin eight sub-groups were tested in shear bond strength : 1) electrochemically etched group(Verabond) using Panavia EX and Superbond C&B 2) tin-plated group(PG-S) using Panavia EX and Superbond C&B 3) salt-treated group(Verabond) using Panavia EX and Superbond C&B 4) meshtreated group(Verabond) using Panavia EX and Superbond C&B. Thermocycling test was conducted on the condition of 15 second dwell time each in $5^{\circ}C$ and $55^{\circ}C$bath. Shear bond strength was measured by Instron Universal Testing Machine(medel 1125). The obtained results were as follows : 1. After thermocycling, the shear bond strengths of tin-plated group and electrochemically etched group were significantly greater than those of salt-treated group and mesh-treated group. And the shear bond strength of Panavia EX was greater than that of Superbond C&B with salt-treated group and tin-plated group(p<0.05). 2. Before thermocycling, electrochemically etched group using Superbond C&B produced the greatest shear bond strength(p<0.01). 3. The shear bond strength of electrochemically etched group using Superbond C&B was significantly decreased after thermocycling(p<0.01). 4. In observation of bond failure modes before thermocycling, Panavia EX highly exhibited enamel fracture. Tin-plated group using Superbond C&B adhesive failure between metal and resin and electrochemically etched group using Superbond C&B exhibited adhesive failure between enamel and rdsin. 5. In observation of failure modes after thermocycling, Panavia EX exhibited cohesive failure and Superbond C&B exhibited adhesive failure between resin and metal.

  • PDF

Treatment and retention of relapsed anterior open-bite with low tongue posture and tongue-tie: A 10-year follow-up

  • Seo, Yu-Jin;Kim, Su-Jung;Munkhshur, Janchivdorj;Chung, Kyu-Rhim;Ngan, Peter;Kim, Seong-Hun
    • 대한치과교정학회지
    • /
    • 제44권4호
    • /
    • pp.203-216
    • /
    • 2014
  • The purpose of the current report is to present 6-year long-term stability and 10-year follow-up data for an adult patient who was treated with a tongue elevator for relapsed anterior open-bite. The 19-year-old male patient presented with the chief complaint of difficulty in chewing his food. Collectively, clinical and radiographic examinations revealed an anterior open-bite, low tongue posture, and tongue-tie. The patient opted for orthodontic treatment alone, without any surgical procedure. A lingual frenectomy was recommended to avoid the risk of relapse, but the patient declined because he was not experiencing tongue discomfort. Initial treatment of the anterior open-bite with molar intrusion and tongue exercises was successful, but relapse occurred during the retention period. A tongue elevator was used for retreatment, because the approach was minimally invasive and suited the patient's requirements regarding discomfort, cost, and time. The appliance changed the tongue posture and generated an altered tongue force, which ultimately resulted in intrusive dentoalveolar effects, and a subsequent counterclockwise rotation of the mandible. The results showed long-term stability and were maintained for six years through continual use of the tongue elevator. The results of this case indicated that a tongue elevator could be used not only as an alternative treatment for open-bite, but also as an active retainer.

소아치과 임상에서의 Thermoformed Appliance의 적용 (APPLICATION OF THERMOFORMED APPLIANCES IN PEDIATRIC DENTISTRY)

  • 김신;정태성;양철호
    • 대한소아치과학회지
    • /
    • 제25권3호
    • /
    • pp.539-544
    • /
    • 1998
  • 저자는 열성형재료와 진공성형기를 이용하여 소아치과 임상에서 사용되는 수 종의 장치를 제작하였다. 전공성형기의 구입에 따른 경제적인 부담은 있으나, 기존의 제작법에 비해 제작이 간편하여 시간이 단축될 뿐 아니라 plate 의 두께가 균일하므로 finishing이 거의 필요하지 않으며 더욱 심미적인 장치를 제작할 수 있다. 또한 조직과 접촉하는 부위는 soft한 열성형재료를 사용하여 치아 이동에 유리할 뿐 아니라, 기존의 resin에 비해 불쾌한 맛이 적다는 장점이 있다. Monomer가 없어 조직에 자극이 적고 mutagenous potential이 없으므로 생체 적합성이 뛰어나 조직의 적응이 용이하다. 복잡하거나 특수한 기능 및 견고성이 필요한 악기능교정 장치 등에서는 그 사용이 제한된다는 한계점이 있으나, 소아치과 임상에서 사용되는 대부분의 장치를 쉽고 간편하게 제작할 수 있어 앞으로 임상에서 널리 이용될 수 있을 것으로 생각된다.

  • PDF

주조체의 설계 변화에 따른 수지접착형 보철물의 접착강도에 관한 연구 (A STUDY ON THE BOND STRENGTH OF RESIN-RETAINED PROTHESIS WITH VARIOUS CAST RETAINER DESIGNS)

  • 주대원;장익태;김광남
    • 대한치과보철학회지
    • /
    • 제30권4호
    • /
    • pp.508-525
    • /
    • 1992
  • The purpose of this study was to evaluate the effect of some resistance form designs on the bond strength of resin-retained prosthesis. Six sub-groups are designed in natural teeth group and resin teeth group . The framework designs in natural teeth group: 1) no groove preparation 2) groove at the center of distal surface 3) groove at the distobuccal line angle 4) 45 degree lateral load with no groove 5) 45 degree lateral load with center groove 6) splint two teeth with no groove. The framework designs in resin teeth group: 1) no groove preparation 2) groove at the center of distal surface 3) groove at the distobuccal line angle 4) metal covered the 1/2 of distal surface 5) metal covered the 1/2 of mesial surface 6) metal extended over the 114 of buccal surface. Specimens were treated electrolytic etching by Oxy-Etch and cemented with Panavia EX. Failure load was measured by Instron. Another 30 specimens were carried out fatigue tests by MTS 810 fatigue testing machine for 5000 cycles at different load level. The following results were obtained from this study. 1. The failure load was significantly increased by resistance forms. 2. The failure load was not increased by increase of total surface area bonded with teeth. The distal surface area played an important role in failure load. 3. In 45 degree lateral load group, the failure load was decreased significantly than that of in vertical load group. 4. Bond failure modes between static test and fatigue test exhibited no differences.

  • PDF