• 제목/요약/키워드: restorative technique

검색결과 302건 처리시간 0.022초

근관충전방법에 따른 폐쇄효과의 비교 (COMPARISON OF THE SEALING ABILITY OF VARIOUS ROOT CANAL FILLING TECHNIQUES)

  • 이동경;윤수한;배광식
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.346-356
    • /
    • 1998
  • The purpose of this study was to evaluate the sealing ability of various canal filling methods. Palatal roots of ninety extracted human maxillary molar teeth were resected at cementoenamel junction. Eighty of them were randomly assigned to four experimental groups, ten were served as positive and negative controls. All canals were prepared to # 40 using Profile. Experimental groups were obturated by lateral condensation technique, Thermafil technique, Continuous Wave of Condensation Technique, and down-pack & back-fill technique of Obtura-II, each with root canal sealer. Control groups were not obturated. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were then ground horizontally at 1.5mm(level 1), 2.5mm(level 2), 3.5 mm(level 3) from the anatomical apex and examined with a stereomicroscope at ${\times}40$ magnification. The gap between the canal wall and the filling material, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was obtained by calculating the ratio of the area of the resin to the total area of the canal and was analyzed statistically (Rank-sum test). The results were as follows : 1. At the level 1, there was the greatest leakage in the Thermafil group and Obtura-II group, and the difference between the Obtura-II group and Continuous Wave of Condensation Technique group was statistically significant(p<0.05). 2. At the level 2, there was the least leakage in the Continuous Wave of Condensation Technique group, but there was no statistically significant difference between each group (p>0.05). 3. At the level 3, there was no statistically significant difference between each group(p>0.05).

  • PDF

Clinical performance of class I cavities restored with bulk fill composite at a 1-year follow-up using the FDI criteria: a randomized clinical trial

  • Chinni Suneelkumar ;Puttaganti Harshala ;Koppolu Madhusudhana;Anumula Lavanya;Anirudhan Subha ;Sannapureddy Swapna
    • Restorative Dentistry and Endodontics
    • /
    • 제46권2호
    • /
    • pp.24.1-24.11
    • /
    • 2021
  • Objectives: The present study aimed to evaluate the survival rate and clinical performance of class 1 composite restorations restored with the Filtek Bulk Fill composite material using either the bulk fill technique or the incremental technique at baseline (1 week) and at 3, 6 and 12 months of follow-up. Materials and Methods: Forty-two patients with at least 2 carious teeth were selected. Following randomization, one tooth was restored with the Filtek Bulk Fill composite using the incremental fill technique, and the other tooth was restored with the same material using the bulk fill technique. Patients were recalled for follow-up at baseline (1 week) and 3, 6, and 12 months and evaluated using the FDI criteria. Results: The data were analyzed using the McNemar χ2 test. No statistically significant differences were found between the scores of teeth restored with either technique. At baseline and at 3, 6, and 12 months of follow-up; there were no significant difference in the clinical status of both groups of restorations. Conclusions: Within the limitations of this study, using the bulk fill technique for restorations with the Filtek Bulk Fill material seems to be equally efficient to using the incremental fill technique.

Silicoater technique을 이용한 veneered stainless steel crown수복의 임상적 평가 (CLINICAL EVALUATION OF VENEERED STAINLESS STEEL CROWN RESTORATION BY SILICOATER TECHNIQUE : CASE REPORT)

  • 정연화;김왕근;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제26권1호
    • /
    • pp.103-108
    • /
    • 1999
  • 광범위한 치질파괴가 있는 상악유전치를 갖는 소아에서 silicoater technique에 의한 veneered stainless steel crown으로 수복 후 $3{\sim}12$개월 동안 주기적 검사와 수복물의 평가 결과, 다음과 같은 결론을 얻었다. 1. 행동조절이 어려운 소아에서 chair time을 감소시킴으로써 행동조절에 도움을 주었다. 2. 유지력, 내구성, 심미성이 우수하였으므로 유전치부의 광범위한 치질손상시 유용한 수복방법이다.

  • PDF

리본 형태의 근관에서 열연화주입법의 근관벽에 대한 적합도에 관한 연구 (A COMPARISON OF THERMOPLASTICIZED INJECIABLE GUTTA-PERCHA TECHNIQUES IN RIBBON-SHAPED CANALS : ADAPTATION TO CANAL WALLS)

  • 황현숙;조경모;김진우
    • Restorative Dentistry and Endodontics
    • /
    • 제27권4호
    • /
    • pp.411-420
    • /
    • 2002
  • The aim of this study is to compare the adaptability of thermoplasticized injectable gutta-percha technique to the canal walls in ribbon-shaped canals. Thirty resin models simulated ribbon-shape canals were instrumented to #40 using .06 taper Profile systems. Three groups of each 10 resin models were obturated by the lateral condensation technique(LC) and the two thermoplasticized injectable gutta-percha technique; Ultrafil Endoset+Obtura II(EO) and Ultrafil Firmset(UF), respectively. After resin model were kept at room temperature for 4 days, they were resected horizontally with micro-tome at 1, 2, 3, 4 and 5mm levels from apex. At each levels. image of resected surface were taken using CCD camera under a stereomicroscope at $\times$40 magnification and stored. Ratio of the area of gutta-percha was obtained by calculating area of gutta-percha cone to the total area of canal using digitized image-ana-Iyzing program. The data were collected then analyzed statistically using One-way ANOVA. The results were as follows. 1 At 1mm levels, there was no statistically significant difference in the mean ratio of gutta-percha among the groups. 2. At 2mm level, EO showed the highest mean ratio of gutta-percha (p<0.05) and there was no significant difference between LC and UF. 3. At 3, 4, 5mm levels, EO and UF had significantly greater mean ratio of gutta-percha than LC(p<0.05) and there was no significant difference between EO and UF. In conclusion, the thermoplasticized injectable gutta-percha techniques demonstrated relatively favorable adaptability to canal walls than lateral condensation technique in ribbon-shaped canals except for 1mm level.

하악공 전달마취법과 Gow-Gates법의 치수마취 효과 (PULPAL ANESTHETIC EFFECT OF INFERIOR ALVEOLAR NERVE BLOCK AND GOW-GATES TECHNIQUE)

  • 안식환;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.278-290
    • /
    • 1997
  • The purposes of this study were to evaluate and compare the pulpal anesthesia induced by an inferior alveolar nerve block and that by Gow-Gates technique, and to investigate the relationship between pulpal anesthesia and intraoral soft tissue responses. After one side of mandibule was anesthetized with inferior alveolar nerve block or Gow-Gates technique using 2 % lidocaine with 1 : 100,000 epinephrine in 19 volunteers of ages between 24 and 29 (16 males and 3 females, average age 25.9 yrs.), electric pulp tests were done on the canine teeth of the anesthetized side and contralateral one before, at 1 min, continued at every 5 minutes until 60 min, and every 10 minutes until 100 min after completion of local anesthetic injection. Degree of pulpal anesthesia was classified as anesthetic failure, possible anesthesia and complete anesthesia by the criteria based on the thresholds to electric pulp test of contralateral canine and the currents of the electric pulp tester. Subjective signs on the lower lip and tongue were checked and prick-pin tests were done on the buccal gingiva of the first molar, buccal and lingual gingiva of the canine tooth at 5, 10 and 20 min after the completion of anesthetic injection. Thresholds to electric pulp test, degree of pulpal anesthesia and relationship between the pulpal anesthesia and soft tissue responses were analyzed with SPSS, paired t-test, Wilcoxon matched-pairs signed-ranks test and correlation analysis. The results were as follows : No significant differences were found in the peak thresholds to electric pulp test, in the induction time to it and in the depth of pulpal anesthesia between inferior alveolar nerve block and Gow-Gates technique (p>0.05). There was no significant relationship between pulpal anesthesia and soft tissue responses in both inferior nerve block and Gow-Gates technique.

  • PDF

In vivo assessment of accuracy of Propex II, Root ZX II, and radiographic measurements for location of the major foramen

  • Tampelini, Fernanda Garcia;Coelho, Marcelo Santos;de Azevedo Rios, Marcos;Fontana, Carlos Eduardo;Rocha, Daniel Guimaraes Pedro;Pinheiro, Sergio Luiz;da Silveira Bueno, Carlos Eduardo
    • Restorative Dentistry and Endodontics
    • /
    • 제42권3호
    • /
    • pp.200-205
    • /
    • 2017
  • Objectives: The aim of this in vivo study was to assess the accuracy of 2 third-generation electronic apex locators (EALs), Propex II (Dentsply Maillefer) and Root ZX II (J. Morita), and radiographic technique for locating the major foramen (MF). Materials and Methods: Thirty-two premolars with single canals that required extraction were included. Following anesthesia, access, and initial canal preparation with size 10 and 15 K-flex files and SX and S1 rotary ProTaper files, the canals were irrigated with 2.5% sodium hypochlorite. The length of the root canal was verified 3 times for each tooth using the 2 apex locators and once using the radiographic technique. Teeth were extracted and the actual WL was determined using size 15 K-files under a ${\times}25$ magnification. The Biostat 4.0 program (AnalystSoft Inc.) was used for comparing the direct measurements with those obtained using radiographic technique and the apex locators. Pearson's correlation analysis and analysis of variance (ANOVA) were used for statistical analyses. Results: The measurements obtained using the visual method exhibited the strongest correlation with Root ZX II (r = 0.94), followed by Propex II (r = 0.90) and Ingle's technique (r = 0.81; p < 0.001). Descriptive statistics using ANOVA (Tukey's post hoc test) revealed significant differences between the radiographic measurements and both EALs measurements (p < 0.05). Conclusions: Both EALs presented similar accuracy that was higher than that of the radiographic measurements obtained with Ingle's technique. Our results suggest that the use of these EALs for MF location is more accurate than the use of radiographic measurements.

Easy Filling 및 Quick Obturation System을 이용한 열연화 충전법의 치근단 밀폐도 평가 (A COMPARISON OF THE APICAL SEAL PRODUCED BY EASY FILLING SYSTEM AND QUICK OBTURATION SYSTEM)

  • 신정인;금기연;이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.202-211
    • /
    • 2000
  • The aim of this study was to compare the apical sealing ability of a new thermoplasticized gutta-percha filling technique, the Easy Filling and the Quick Obturation system with lateral condensation technique and Thermafil system to evaluate their clinical acceptabilities. Fifty-two extracted single-rooted teeth were instrumented to #35 using the .04 taper ProFile system. Four groups of 12 teeth were obturated by lateral condensation technique. Thermafil system and two new thermoplasticized gutta-percha techniques, the Easy Filling system and Quick Obturation system (Meta Dental co. Ltd. Korea), respectively. Four teeth served as controls. After the teeth were immersed in 2% methylene blue dye for 48 hours, they were resected horizontally at 1mm to 5mm level from the anatomical apex using a low-speed microtome. Each section was examined under a stereomicroscope at ${\times40}$ magnification and photographed. After each image was scanned, the leakage area was measured at each level using Brain 3 (Nosdia Tech., Korea) software. Leakage ratio was calculated for each group and was analyzed statistically to come up with the following results: 1. At 1mm level, the Quick Obturation system had the largest amount of apical leakage and it was statistically significant when compared with the lateral condensation group and the Thermafil group (p<0.05). 2. At 2mm and 3mm level, there were no significant difference of apical leakage among all four groups (p>0.05), and from 4mm level, no apical dye penetration was observed in all the groups. In conclusion, the apical seal produced by Easy Filling system and the Quick Obturation system was comparable to lateral condensation technique and Thermafil system except for the 1mm level. More improvement of the apical seal can be expected as the operator becomes skillful with the new techniques.

  • PDF

변형된 치관부 파절편 재부착술식을 이용한 치관치근파절의 치료 (Treatment of crown-root fracture with a modified crown fragment reattachment technique)

  • 송창원;송민주;신수정;박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제35권5호
    • /
    • pp.395-400
    • /
    • 2010
  • 치관부 파절편 재부착술식은 접착치의학의 발달과 더불어 치관파절 치료 방법 중 하나로 자리매김하였다. 하지만 치관치근파절된 치아에 있어서 기존의 치관부 파절편 재부착술식으로는 치은연하 영역의 수복 및 생물학적 폭경의 유지가 어려워 부가적인 치관연장술 또는 치아 정출술 등이 요구되게 된다. 하지만 이번 증례보고는 치수노출을 동반한 치관-치근파절을 치료함에 있어서 이러한 부가적인 술식 없이 변형된 치관부 파절편 재부착술식만을 이용하여 처치한 사례이다. 환자는 근관치료 후 post 삽입 및 재부착 술식을 시행 받았으며 이때 치관 파절편의 변형을 통해 생물학적 폭경을 위한 공간 유지 및 적절한 접착을 위한 영역을 확보할 수 있었고 이후 한차례의 재파절이 발생하였지만 재차 재부착 후 2년간의 follow up을 통해 치주부착상실 없이 치관 파절편이 잘 유지되는 것이 관찰되었다.

가변 광도에 따른 복합레진의 기계적 물성 및 변연누출도 변화 (MECHANICAL PROPERTIES AND MICROLEAKAGE OF COMPOSITE RESIN MATERIALS CURED BY VARIABLE LIGHT INTENSITIES)

  • 한승렬;민경산;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제28권2호
    • /
    • pp.134-145
    • /
    • 2003
  • Mechanical properties and microleakage of two composites [conventional hybrid type DenFil (VERICOM Co., Anyang, Korea) / micro matrix hybrid type Esthet X (Dentsply Caulk, Milford, DE, U.S.A.)] were evaluated to assess whether variable light intensity curing is better than conventional curing technique. Curing was done for 40 seconds in two ways of 2 step soft-start technique and 5 step ramping technique. Three kinds of light intensities of 50, 100, $200{\;}mW/\textrm{cm}^2$ were initially used for 10, 20, 30 seconds each and the maximum intensity of $600 {\;}mW/\textrm{cm}^2$ was used for the rest of curing time in a soft-start curing tech nique. In a ramping technique, curing was done with the same initial intensities and the light intensity was increased 5 times with the same rate to the maximum intensity of $600{\;}mW/\textrm{cm}^2$. After determining conditions that showed no different mechanical properties with conventional technique, Esthet X composite was filled in a class V cavity, which dimension was $4{\times}3{\times}1.5{\;}mm$ and cured under those conditions. Microleakage was evaluated in two ways of dye penetration and maximum gap estimation through SEM observation. ANOVA and Spearman's rho test were used to confirm any statistical significance among groups. The results were as follows : 1 Several curing conditions of variable light intensities resulted in the similar mechanical properties with a conventional continuous curing technique, except conditions that start curing with an initial light intensity of $50{\;}mW/\textrm{cm}^2$. 2. Conventional and ramping techniques were better than soft-start technique in mechanical properties of microhardness and compressive strength. 3. Soft-start group that started curing with an initial light intensity of $100{\;}mW/\textrm{cm}^2$ for 10 seconds showed the least dye penetration. Soft-start group that started curing with an initial light intensity of $200{\;}mW/\textrm{cm}^2$ for 10 seconds showed the smallest marginal gap, if there was no difference among groups. 4. Soft-start technique resulted in better dye-proof margin than conventional technique(p=0.014) and ramping technique(p = 0.002). 5. There was a very low relationship(p=0.157) between the methods of dye penetration and marginal gap determination through SEM evaluation. From the results of this study, it was revealed that ramping technique would be better than conventional technique in mechanical properties, however, soft-start technique might be better than conventional one in microleakage. It was concluded that much endeavor should be made to find out the curing conditions, which have advantages of both aspects or to solve these kinds of problems through a novel idea of polymerization.

Esthetic rehabilitation of single anterior edentulous space using fiber-reinforced composite

  • Kim, Hyeon;Song, Min-Ju;Shin, Su-Jung;Lee, Yoon;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • 제39권3호
    • /
    • pp.220-225
    • /
    • 2014
  • A fiber-reinforced composite (FRC) fixed prosthesis is an innovative alternative to a traditional metal restoration, as it is a conservative treatment method. This case report demonstrates a detailed procedure for restoring a missing anterior tooth with an FRC. A 44-year-old woman visited our department with an avulsed tooth that had fallen out on the previous day and was completely dry. This tooth was replanted, but it failed after one year. A semi-direct technique was used to fabricate a FRC fixed partial prosthesis for its replacement. The FRC framework and the pontic were fabricated using a duplicated cast model and nanofilled composite resin. Later on, interproximal contact, tooth shape, and shade were adjusted at chairside. This technique not only enables the clinician to replace a missing tooth immediately after extraction for minimizing esthetic problems, but it also decreases both tooth reduction and cost.