• 제목/요약/키워드: restorative

검색결과 2,651건 처리시간 0.025초

High-plasticity mineral trioxide aggregate and its effects on M1 and M2 macrophage viability and adherence, phagocyte activity, production of reactive oxygen species, and cytokines

  • Betania Canal Vasconcellos;Layara Cristine Tomaz Tavares;Danilo Couto da Silva;Francielen Oliveira Fonseca ;Francine Benetti ;Antonio Paulino Ribeiro Sobrinho ;Warley Luciano Fonseca Tavares
    • Restorative Dentistry and Endodontics
    • /
    • 제48권1호
    • /
    • pp.6.1-6.14
    • /
    • 2023
  • Objectives: This study evaluated the effects of high-plasticity mineral trioxide aggregate (MTA-HP) on the activity of M1 and M2 macrophages, compared to white MTA (Angelus). Materials and Methods: Peritoneal inflammatory M1 (from C57BL/6 mice) and M2 (from BALB/c mice) macrophages were cultured in the presence of the tested materials. Cell viability (MTT and trypan blue assays), adhesion, phagocytosis, reactive oxygen species (ROS) production, and tumor necrosis factor (TNF)-α and transforming growth factor (TGF)-β production were evaluated. Parametric analysis of variance and the non-parametric Kruskal-Wallis test were used. Results were considered significant when p < 0.05. Results: The MTT assay revealed a significant decrease in M1 metabolism with MTA-HP at 24 hours, and with MTA and MTA-HP later. The trypan blue assay showed significantly fewer live M1 at 48 hours and live M2 at 48 and 72 hours with MTA-HP, compared to MTA. M1 and M2 adherence and phagocytosis showed no significant differences compared to control for both materials. Zymosan A stimulated ROS production by macrophages. In the absence of interferon-γ, TNF-α production by M1 did not significantly differ between groups. For M2, both materials showed higher TNF-α production in the presence of the stimulus, but without significant between-group differences. Likewise, TGF-β production by M1 and M2 macrophages was not significantly different between the groups. Conclusions: M1 and M2 macrophages presented different viability in response to MTA and MTA-HP at different time points. Introducing a plasticizer into the MTA vehicle did not interfere with the activity of M1 and M2 macrophages.

알카자이트 수복재의 색안정성 : 실험실적 연구 (Color Stability of Alkasite Restorative Material: in vitro Studies)

  • 안지혜;이상호;이난영;신혜원;지명관
    • 대한소아치과학회지
    • /
    • 제49권4호
    • /
    • pp.428-441
    • /
    • 2022
  • 이 연구의 목적은 알카자이트 수복재와 소아치과 영역에서 널리 사용되고 있는 수복재들의 색 안정성을 비교하고, 다양한 음료에서의 색상 변화를 비교하는 것이다. 글라스아이오노머, 레진강화형 글라스아이오노머, 알카자이트 수복재, 복합레진의 시편을 준비하였고, 열순환 후 색 안정성을 측정하였다. 침전 전과 7일, 14일, 21일, 28일 후 CIE L*a*b*값의 색상 변화를 분석하기 위해 각 수복재료의 시편을 5개의 군으로 나누어 각각 PBS, 커피, 녹차, 콜라, 오렌지주스 용액에 침전시켰다. 열순환 후 복합레진에서 가장 높은 색 안정성을 보였고, 알카자이트 수복재, 글라스아이오노머, 레진강화형 글라스아이오노머 순으로 높은 안정성을 보였다. 7일간 다양한 용액에 침전시킨 결과 모든 시편에서 색상 변화가 나타났으며, 알카자이트 수복재는 글라스아이오노머 계열보다 낮은 색상 변화를 보였고, 복합레진보다는 높은 색상 변화를 나타냈다. 알카자이트 수복재는 커피에서 가장 많은 색상 변화가 나타났으며 그 다음은 녹차, 오렌지주스 순이었으나, 콜라와 PBS 용액에서는 침전 28일 이후에도 색상 변화를 거의 보이지 않았다.

Si-O Bridged 실리카가 충진된 치아수복용 고분자 복합체의 중합 특성 (Polymerization Behavior of Polymeric Dental Restorative Composites Filled with Si-O Bridged Silica)

  • 김오영;이정수
    • 공업화학
    • /
    • 제16권5호
    • /
    • pp.672-676
    • /
    • 2005
  • 치아수복용 고분자 복합체(polymeric dental restorative composite, PDRC)의 전치부와 구치부에의 응용 가능성을 높이고자 PDRC를 구성하는 실리카 충진재를 다양한 온도에서 열처리시켜 siloxane 기로 연결된 구조의 개질된 실리카를 제조하고 이를 PDRC 제조에 사용하였다. 제조된 PDRC의 중합 특성을 중합전환률, 중합깊이, 그리고 체적 중합수축률 등을 분석하여 고찰하였다. 실험 결과, 사용된 실리카의 열처리 온도가 높아짐에 따라 제조된 PDRC의 중합깊이는 감소하였고 체적 중합수축률과 중합전환률 값은 실리카 입자의 평균크기 감소에 따른 PDRC 내 resin matrix의 상대적 양의 증가로 인해 일정하게 증가함을 알 수 있었다.

근관 치료 후 수복 방법이 파절 강도와 파절 양상에 미치는 영향 (The Effect of Restorative Method on Fracture Strength and Fracture Pattern in Endodontically Treated Teeth)

  • 안동국;조인호;신수연
    • 구강회복응용과학지
    • /
    • 제21권2호
    • /
    • pp.133-142
    • /
    • 2005
  • The purpose of this study was to evaluate interaction of restorative method according to amount of remaining clinical crown length. For the study, sixty healthy mandibular premolars with no dental caries were chosen. Specimens with clinical crown length of 1 mm, 2 mm, 3 mm above the cemento-enamel junction(CEJ) were prepared and root canal treatment was conducted using Ni-Ti rotaty files. Thirty specimens were restored with $LuxaCore^{(R)}$ and thirty were restored with casting posts. All specimens were restored with full coverage crowns and the fracture strength was teseted with the MTS universal testing marchine. The fracture pattern was observed by measuring the distance between CEJ and fracture line. From the results above, the fracture strength seems to be influenced more by amount of remaining clinical crown length than restorative method. Good prognosis could be expected, when more than 2mm of clinical crown length is retained. In the future, the further studies on restorative method, to increase fracture strength of teeth will be necessary.

치과용 3D 프린터로 제작된 임시 수복용 레진의 정확도 평가 (Evaluation of the accuracy of provisional restorative resins fabricated using dental 3D printers)

  • 김민수;김원기;강월
    • 한국치위생학회지
    • /
    • 제19권6호
    • /
    • pp.1089-1097
    • /
    • 2019
  • Objectives: The purpose of this study is to assess the accuracy of provisional restorative resins fabricated using dental three-dimensional (3D) printers. Methods: Provisional restorative resins were fabricated using the first molar of the right mandibular. Three groups comprising a total of 24 samples of such resins were fabricated. The prepared abutment was scanned initially and then designed using a computer-aided design (CAD) software. The conventional subtractive manufacturing system was employed to fabricate the first group of resins, while the second and third groups were fabricated using a digital light processing (DLP) 3D printer and a stereolithography (SLA) 3D printer, respectively. The internal surfaces of the resins were scanned and 3D measurements of the resins were taken to confirm their accuracy. Results: The root-mean-square deviation (RMS±SD) of the accuracy of the resins fabricated using the conventional subtractive manufacturing system, DLP 3D printer, and SLA 3D printer were 68.83±2.22 ㎛, 74.63±6.23 ㎛, and 61.74±4.09 ㎛, respectively. A one-way analysis of variance (ANOVA) test showed significant differences between the three groups (p < 0.05). Conclusions: Provisional restorative resins fabricated using DLP and SLA 3D printers demonstrated clinically-acceptable results.

중합가시광 파장대에 따른 심미성 수복재의 미세경도 변화 (MICROHARDNESS OF ESTHETIC RESTORATIVE MATERIALS CURED BY 3 TYPES OF NARROW-BANDED WAVELENGTH)

  • 김현철;조경모;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제26권2호
    • /
    • pp.127-133
    • /
    • 2001
  • There are several factors affecting the effectiveness of polymerization of the esthetic restorative materials. Among those factors, the initiator. camphoroquinone has the unique characteristic. of which the light sensitivity is very dependent on the wavelength of blue light. Camphoroquinone shows the most light absorption ability in the wavelength range of 470nm. So most of clinically used light curing systems adopt this phenomenon as their polymerization mechanism. The most popular way of light curing system is standard 40 second curing. But the problem of standard curing technique shows the rapid increase of resin viscosity followed by the acceleration of polymerization and the limited resin flow, resulted in reduction of the physicalproperty of restoration by retained stress. The object of this study was to verify the effects of narrow-banded wavelength on the microhardness of the esthetic restorative materials. a composite resin and a compomer, using filters which have peak wave length of 430nm, 450nm, 470nm, respectively. The results were as follows: 1. All the experimental groups showed lower hardness value than the control group. 2. In DyractAP, the hardness value by wavelength showed the same changing pattern on both upper and lower surfaces. 3. In DenFil, the hardness value by wavelength showed different changing pattern on upper and lower surfaces. 4. The hardness ratio showed similar pattern to the hardness variation of lower surface. but there was no significant difference between measurement in 10 minutes and 3 days later, besides the increase of hardness value.

  • PDF

수종(數種) 수복물(修復物)의 표면(表面) 연마효과(硏磨效果)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON THE SURFACE POLISHING EFFECTS OF VARIOUS RESTORATIVE MATERIALS)

  • 박영호;민병순;최호영;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제10권1호
    • /
    • pp.103-114
    • /
    • 1984
  • The purpose of this study was to compare the polished surfaces of two composite resins (Clearfil F and Durafill) with those of glass ionomer cement (Fuji ionomer cement) and to observe what types of polishing devices are valuable, and then to establish a clinically satisfactory procedures. Studies have been undertaken to determine the effects of glass plate matrix and finishing instruments (Carborundum point, White point and Sof-Lex medium) on the surface finish of three restorative materials. The results were examined with profilometer (Kosaka laboratory LTD. Tokyo, Japan) and scanning electron microscopy (JSM-T20: JEOL). The results were as follows: 1. The most satisfactory surface finishes were produced against glass matrix. 2. Coarser finishes were obtained with use of carborundum point. 3. Generally Fuji ionomer cement were left surfaces with higher roughness values. 4. The smoothest finishes were obtained with Sof-lex medium. 5. Clearfil-F was showed more smoother than the other restorative materials.

  • PDF

Intraoperative discomfort associated with the use of a rotary or reciprocating system: a prospective randomized clinical trial

  • Gomes, Aline Cristine;Soares, Adriana Jesus;Souza, Erick M;Zaia, Alexandre Augusto;Silva, Emmanuel Joao Nogueira Leal
    • Restorative Dentistry and Endodontics
    • /
    • 제42권2호
    • /
    • pp.140-145
    • /
    • 2017
  • Objectives: The aim of this randomized, controlled, prospective clinical study was to evaluate patients' intraoperative discomfort during root canal preparations in which either multi-file rotary (Mtwo) or single-file reciprocating (Reciproc) systems were used. Materials and Methods: Fifty-five adult patients, aged between 25 and 69 years old, with irreversible pulpitis or pulp necrosis participated in this study. Either the mesiobuccal or the distobuccal canals for maxillary molars and either the mesiobuccal or the mesiolingual canals for mandibular molars were randomly chosen to be instrumented with Mtwo multi-file rotary or Reciproc single-file reciprocating systems. Immediately after each canal instrumentation under anesthesia, patient discomfort was assessed using a 1 - 10 visual analog scale (VAS), ranging from 'least possible discomfort' (1) to 'greatest possible discomfort' (10). The Wilcoxon signed-rank test was used to determine significant differences at p < 0.05. Results: Little intraoperative discomfort was found in all cases. No statistically significant differences in intraoperative discomfort between the 2 systems were found (p = 0.660). Conclusions: Root canal preparation with multi-file rotary or single-file reciprocating systems had similar and minimal effects on patients' intraoperative discomfort.

Chair-side CAD/CAM fabrication of a single-retainer resin bonded fixed dental prosthesis: a case report

  • Jurado, Carlos Alberto;Tsujimoto, Akimasa;Watanabe, Hidehiko;Villalobos-Tinoco, Jose;Garaicoa, Jorge Luis;Markham, Mark David;Barkmeier, Wayne Walter;Latta, Mark Andrew
    • Restorative Dentistry and Endodontics
    • /
    • 제45권2호
    • /
    • pp.15.1-15.7
    • /
    • 2020
  • This clinical report describes designing and fabricating a single-retainer resin-bonded fixed dental prosthesis with a chair-side computer-aided design/computer-aided manufacturing system. The whole procedure, from tooth extraction to final placement of the prosthesis, was completed in one day, and a single clinic visit. No clinical complications were found at the 2-year follow-up after placement of the restoration, and satisfactory functional and esthetic results were achieved.

Influence of different universal adhesives on the repair performance of hybrid CAD-CAM materials

  • Demirel, Gulbike;Baltacioglu, Ismail Hakki
    • Restorative Dentistry and Endodontics
    • /
    • 제44권3호
    • /
    • pp.23.1-23.9
    • /
    • 2019
  • Objectives: The aim of this study was to investigate the microshear bond strength (${\mu}SBS$) of different universal adhesive systems applied to hybrid computer-aided design/computer-aided manufacturing (CAD-CAM) restorative materials repaired with a composite resin. Materials and Methods: Four types of CAD-CAM hybrid block materials-Lava Ultimate (LA), Vita Enamic (VE), CeraSmart (CS), and Shofu Block HC (SH)-were used in this study, in combination with the following four adhesive protocols: 1) control: porcelain primer + total etch adhesive (CO), 2) Single Bond Universal (SB), 3) All Bond Universal (AB), and 4) Clearfil Universal Bond (CU). The ${\mu}SBS$ of the composite resin (Clearfil Majesty Esthetic) was measured and the data were analyzed using two-way analysis of variance and the Tukey test, with the level of significance set at p < 0.05. Results: The CAD-CAM block type and block-adhesive combination had significant effects on the bond strength values (p < 0.05). Significant differences were found between the following pairs of groups: VE/CO and VE/AB, CS/CO and CS/AB, VE/CU and CS/CU, and VE/AB and CS/AB (p < 0.05). Conclusions: The ${\mu}SBS$ values were affected by hybrid block type. All tested universal adhesive treatments can be used as an alternative to the control treatment for repair, except the AB system on VE blocks (the VE/AB group). The ${\mu}SBS$ values showed variation across different adhesive treatments on different hybrid CAD-CAM block types.