Effect of flowable resin composite on bond strength to wedge shaped cavity walls.

  • Ogata, M.;Pereira, PNR.;Harada, N.;Nakajima, M.;Nikaida, T.;Tagami, J.
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.558.1-558
    • /
    • 2001
  • Flowable resin composite is a relatively new restorative material. It has been reported that a low viscosity, low modulus intermediate resin applied between the bonding agent and restorative resin act as an "elastic buffer" that can relieve contraction stress. This in-vitro study aimed to evaluate the effect of flowable composite resin as a restorative material on regional tensile bond stredgth to cervical wedge shaped cavity walls. (omitted)

  • PDF

심미보철을 위한 치주치료 (Periodontal Plastic Surgery for Esthetic Restoration)

  • 김정해
    • 대한치과의사협회지
    • /
    • 제48권9호
    • /
    • pp.670-679
    • /
    • 2010
  • Esthetic demands for dental treatment are increasing every day. The interdisciplinary relationship of the restorative treatment, periodontal therapy and other treatments such as endodontics, orthodontics and so on is more emphasized nowadays to reconstruct the hard and soft tissue foundation for the esthetic restorative treatment. This article will focus on the periodontal plastic surgery for esthetic restorative treatment. These followings will be discussed. 1. Understand the relationship between teeth and gingival scaffold for esthetics 2. Discuss the classification and treatment of gummy smile 3. Recognize the gingival margin irregularities by gingival recession and how to achieve the harmonic soft tissue margins 4. describe the hard and soft tissue augmentation for ridge augmentation.

단열성 단면복구 Mortar의 내구성에 관한 연구 (A Study on the Durability of Restorative Cement Mortar with Insulation Performance)

  • 나승현;김형진;서병돌;강현주;송명신
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.495-496
    • /
    • 2009
  • 콘크리트는 항온에서보다 온도의 편차가 클수록 열화가 빠르게 진행되기 때문에 열화된 콘크리트의 물성을 복구하기 위하여 사용되는 단면복구재는 외부 온도 변화에 의한 단면복구재의 품질 변화가 적거나 단면복구재에 의해 복구된 열화 콘크리트의 안정화를 유지할 수 있는 품질을 확보해야 할 필요가 있다. 본 연구에서는 일반적인 단면복구 mortar에 단열성능을 부여하여 열화 콘크리트 보수용 재료로서의 내구성능 변화에 대해 연구하였다.

  • PDF

금원시대(金元時代) 이후(以後) 침구보사이론(鍼灸補瀉理論) 발전사(發展史)에 관(關)한 연구(硏究) (A Study of restorative and restrictive theory after Jin and Yuan Dynasty)

  • 김규만;김기욱;박현국;이병욱
    • 한국의사학회지
    • /
    • 제15권1호
    • /
    • pp.3-10
    • /
    • 2002
  • Acupuncture and moxibustion of theory had begun in the "Nei-Jing" and "Nan-Jing". But definite acupuncture needling techniques had been investigated after Jin and Yuan Dynasty. After Ming Dynasty, much more scholars had studied about definite acupuncture needling techniques. So various techniques and theorys about how to select and operate needling points appeared in print. "Zi-Wu-Liu-Zhu-Zhen-Jing", "Zhen-Jing-Zhi-Nan", "Shen-Ying-Jing", "Zhen-Jiu-Da-Quan" and so forth are representative books. But these books include mutually different techniques, so then scholars would be thrown into confusion. So I have analysed acupuncture and moxibustion of theory into Ki(vital energy)-blood's circulation, disease region, time, sex, restorative and restrictive techniques. As a result, I have known that every restorative and restrictive techniques and theories are connected with Ki(vital energy)-blood's circulation and practical application methods are decided by sex, time, disease region, pathogenic energy.

  • PDF

Translucency changes of direct esthetic restorative materials after curing, aging and treatment

  • Lee, Yong-Keun
    • Restorative Dentistry and Endodontics
    • /
    • 제41권4호
    • /
    • pp.239-245
    • /
    • 2016
  • The purpose of this article was to review the changes in translucency of direct esthetic restorative materials after curing, aging and treatment. As a criterion for the evaluation of clinical translucency changes, visual perceptibility threshold in translucency parameter difference (${\Delta}TP$) of 2 was used. Translucency changes after curing were perceivable depending on experimental methods and products (largest ${\Delta}TP$ in resin composites = 15.9). Translucency changes after aging were reported as either relatively stable or showed perceivable changes by aging protocols (largest ${\Delta}TP$ in resin composites = -3.8). Translucency changes after curing, aging and treatment were perceivable in several products and experimental methods. Therefore, shade matching of direct esthetic materials should be performed considering these instabilities of translucency in direct esthetic materials.

Clinical efficacy of activated irrigation in endodontics: a focused review

  • Amelia Wan Tin Cheung;Angeline Hui Cheng Lee;Gary Shun Pan Cheung
    • Restorative Dentistry and Endodontics
    • /
    • 제46권1호
    • /
    • pp.10.1-10.16
    • /
    • 2021
  • Root canal debridement, which includes the removal of infected tissues and microbial biofilms, is considered the corner stone of root canal treatment. Chemical adjuncts play a multitude of functions in this regard, as tissue solvents, antimicrobial agents and for removing the smear layer. These adjuncts (irrigants) are usually delivered using a syringe and needle. With increasing knowledge of the complexity of root canal anatomy and tenacity of microbial biofilms, the need for strategies that potentiate the action of these irrigants within the root canal system cannot be overemphasized. Several such activated irrigation strategies exist. The aim of this review is to comprehensively discuss the different irrigant activation methods from the context of clinical studies.

The effect of individualization of fiberglass posts using bulk-fill resin-based composites on cementation: an in vitro study

  • Lins, Rodrigo Barros Esteves;Cordeiro, Jairo Matozinho;Rangel, Carolina Perez;Antunes, Thiago Bessa Marconato;Martins, Luis Roberto Marcondes
    • Restorative Dentistry and Endodontics
    • /
    • 제44권4호
    • /
    • pp.37.1-37.10
    • /
    • 2019
  • Objectives: This study evaluated the bond strength of various fiberglass post cementation techniques using different resin-based composites. Materials and Methods: The roots from a total of 100 bovine incisors were randomly assigned to 5 treatment groups: G1, post + Scotchbond Multi-Purpose (SBMP) + RelyX ARC luting agent; G2, relined post (Filtek Z250) + SBMP + RelyX ARC; G3, individualized post (Filtek Z250) + SBMP; G4, individualized post (Filtek Bulk-Fill) + SBMP; G5, individualized post (Filtek Bulk-Fill Flow) + SBMP. The samples were subjected to the push-out (n = 10) and pull-out (n = 10) bond strength tests. Data from the push-out bond strength test were analyzed using 2-way analysis of variance (ANOVA) with the Bonferroni post hoc test, and data from the pull-out bond strength test were analyzed using 1-way ANOVA. Results: The data for push-out bond strength presented higher values for G2 and G5, mainly in the cervical and middle thirds, and the data from the apical third showed a lower mean push-out bond strength in all groups. No significant difference was noted for pull-out bond strength among all groups. The most frequent failure modes observed were adhesive failure between dentine and resin and mixed failure. Conclusions: Fiberglass post cementation using restorative and flowable bulk-fill composites with the individualization technique may be a promising alternative to existing methods of post cementation.

A COMPARATIVE STUDY BETWEEN DEGREE OF CONVERSION AND FLEXURAL STRENGTH OF COMPOSITE RESINS

  • Lee Seong-Hee;Pae Ahran;Kim Sung-Hun
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.333-342
    • /
    • 2006
  • Statement of problem. Although many studies have been carried out to investigate the correlation between the degree of conversion and the flexural strength of composite resins, there is minimal information in the literature attempting to compare degree of conversion, flexural strength and their correlation between restorative composite resins and flowable composite resins. Purpose. The purposes of this study were to measure the degree of conversion and flexural strength of composite resins with different rheological behavior and to correlate the two properties. Materials and methods. Four restorative (Vit-1-escence, Z-250, Tetric ceram, Esthet-X) and four flowable (Aeliteflo, Admiraflow, Permaflo, Revolution) light-curing composite resins were investigated. The degree of conversion(DC) was analyzed with Fourier transfer infra-red spectroscopy(FTIR) spectrum by a potassium bromide(KBr) pellet transmission method. The spectrum of the unpolymerized specimen had been measured before the specimen was irradiated for 60s with a visible light curing unit. The Poiymerized specimen was scanned for its in spectrum. The flexural strength(FS) was measured with 3-point bending test according to ISO 4049 after storage in water at $37^{\circ}C$ for 24 hours. The data were statistically analyzed by an independent sample t-test and one-way ANOVA at the significance level of 0.05. The dependence of flexural strength on the degree of conversion was also analyzed by regression analysis. Results. Mean DC and FS values ranged from 43% to 61% and from 84.7MPa to 156.7MPa respectively. DC values of the flowable composite resins were significantly higher than those of restorative composite resins (P < 0.05). The FS values of restorative composite resins were greater than those of flowable composite resins. No statistically significant correlation was observed between the DC and the FS tested in any of the composites. The dependence of FS on DC in restorative or flowable composite resins was not significant. Conclusion. It can be concluded that radical polymerization of the organic matrix is not a major factor in determining flexural strength of the commercially available composite resins.

광중합 시 수종의 심미적 수복재와 이장재의 사용에 따른 치수내 온도변화 (TEMPERATURE CHANGES IN THE PULP ACCORDING TO VARIOUS ESTHETIC RESTORATIVE MATERIALS AND BASES DURING CURING PROCEDURE)

  • 장혜란;이형일;이광원;이세준
    • Restorative Dentistry and Endodontics
    • /
    • 제26권5호
    • /
    • pp.393-398
    • /
    • 2001
  • Polymerization of light-activated restorations results in temperature increase caused by both the exothermic reaction process and the energy absorbed during irradiation. Within composite resin, temperature increases up to 2$0^{\circ}C$ or more during polymerization. But, insulation of hard tissue of tooth lowers this temperature increase in pulp. However, many clinicians are concerned about intrapulpal temperature injury. The purpose of this study was to evaluate temperature changes in the pulp according to various restorative materials and bases during curing procedure. Caries and restoration-free mandibular molars extracted within three months were prepared Class I cavity of 3$\times$6mm with high speed handpiece fissure bur. 1mm depth of dentin was evaluated with micrometer in mesial and distal pulp horns. Pulp chambers were filled with 37.0$\pm$0.1$^{\circ}C$ water to CEJ. Chromium-alumina thermocouple was placed in pulp horn below restorative materials for evaluating of temperature changes. This thermocouple was connected to temperature-recording device(Multiplication analyzer MX, 6.000, JAPAN). Temperature changes was evaluated from initial 37.$0^{\circ}C$ after temperature changes to 37.$0^{\circ}C$. Tip of curing unit was placed in the center of prepared cavity separated 1mm from restorative materials. Curing time was 40s. The restorative materials were used with Z 100, Fuji II LC, Compoglass flow and bases were used with Vitrebond, Dycal. Resrorative materials were placed in 2mm. The depth of bases were formed in 1mm and in this upper portion, resin of 2mm depth was placed. This procedure was performed 10 times. The results were as follows. 1. All the groups showed that the temperature in pulp increased as curing time increased 2. The temperature increase of glass ionomer was significantly higher than that of Resin and Compomer during curing procedure (P<0.05). 3. The temperature increase in glass ionomer base was significantly higher than that of Calcium hydroxide base during Resin curing procedure (P<0.05).

  • PDF

Influence of operator's experience level on lifespan of the WaveOne Primary file in extracted teeth

  • Saleh, Abdulrahman Mohammed;Tavanafar, Saeid;Vakili-Gilani, Pouyan;Al Sammerraie, Noor Jamal;Rashid, Faahim
    • Restorative Dentistry and Endodontics
    • /
    • 제38권4호
    • /
    • pp.222-226
    • /
    • 2013
  • Objectives: The aim of this study was to assess the influence of operator experience level on the lifespan of the WaveOne Primary file (Dentsply Maillefer, Ballaigues, Switzerland) in extracted teeth. Materials and Methods: Moderately curved canals of extracted maxillary and mandibular molars were randomly distributed into 2 groups: experienced and inexperienced operators. Ten files were allocated to each group (n = 10). Each canal was prepared until the working length was reached, and the same file was used to prepare additional canals until it separated. The number of canals prepared before file separation was recorded. The fragment length of each file was measured, and the location of the fragment in the canal was determined. Data were statistically analysed using the independent 2-sample t-test. Results: The 2 operators prepared a total of 324 moderately curved canals of maxillary and mandibular molars. There was no significant intergroup difference in the mean number of canals prepared (p = 0.27). The average lifespan of the WaveOne Primary file was 17.1 and 15.3 canals, and the longest lifespan was 25 and 20 canals, when used by experienced and inexperienced operators, respectively. There were no statistically significant intergroup differences in separated fragment length and location. Conclusions: Within the limitations of this study, operator experience level appears to have no effect on the lifespan of the WaveOne Primary file in preparation of moderately curved canals. Single teeth with multiple canals can be prepared safely even by a novice operator by using a single file.