• 제목/요약/키워드: resonant response

검색결과 289건 처리시간 0.042초

Optimal Control Design-based Gain Selection of an LCL-filtered Grid-connected Inverter in State-Space under Distorted Grid Environment

  • Tran, Vi-Thuy;Yoon, Seung-Jin;Kim, Kyeong-Hwa
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.344-345
    • /
    • 2018
  • In order to alleviate the negative impacts of harmonically distorted grid condition on grid-connect inverters, an optimal control design-based gain selection scheme of an LCL-filtered grid-connected inverter and its ability to compensate selective harmonics are presented in this paper. By incorporating resonant terms into the control structure in the state-space to provide infinity gain at selected frequencies, the proposed control offers an excellent steady-state response even under distorted grid voltage. The proposed control scheme is achieved by using a state feedback controller for stabilization purpose and by augmenting the resonant terms as well as intergral term into a control structure for reference tracking and harmonic compensation. Furthermore, the optimal linear quadratic control approach is adopted for choosing an optimal feedback gain to ensure an asymptotic stability of the whole system. A discrete-time full state observer is also introduced into the proposed control scheme for the purpose of reducing a total number of sensors used in the inverter system. The simulation results are given to prove the effectiveness and validity of the proposed control scheme.

  • PDF

6배압 정류기를 이용한 고전압 전원장치에 관한 연구 (A Study of the High Voltage Power Supply using a Sixfold Voltage-Multiplying Rectifier)

  • 안태영;길용만
    • 조명전기설비학회논문지
    • /
    • 제29권2호
    • /
    • pp.19-26
    • /
    • 2015
  • This paper presents design, fabrication, and performance evaluation of a high voltage power supply for Carbon Nano Tube-based planar light sources. The proposed power supply employs an LLC resonant half-bridge converter and a sixfold voltage-multiplying rectifier. Steady-state characteristics of the voltage-multiplying rectifier are analyzed and used to derive the input-to-output voltage conversion ratio of the power supply. The input-to-output frequency response characteristics of the LLC tank circuit are analyzed and utilized in designing a proto-type power supply which produces a 15 KV output using a 400 V input source. The high-voltage transformer is fabricated using a sectional bobbin structure with an epoxy impregnation, in order to provide sufficient insulation for high voltage operations. The performance of the proposed power supply is confirmed with stable and reliable operations at the 15 KV output from no load to nominal load conditions. The proposed power supply is well suited as an electric ballast required stable operations of Carbon Nano Tube-based planar light sources.

주파수 응답해석을 통한 제작공차를 가지는 저압터빈 케이싱의 고진동 원인 규명 (Investigation of the Cause of High Vibration in a Low Pressure Turbine Casing with Manufacturing Defects by Frequency Response Analysis)

  • 윤희철;우창기;황재곤
    • 한국생산제조학회지
    • /
    • 제24권4호
    • /
    • pp.463-468
    • /
    • 2015
  • High vibration of a low pressure (LP) turbine casing caused safety problems and life at the facility it was housed in. The main focus of this study was the cause of the high vibration in a low pressure turbine casing with manufacturing defects by frequency response analysis, compared with the results of experiments. Therefore, excited accelerations were obtained from the LP casing fundamental, and frequency responses were analyzed. The measurement and the modal analysis showed that the natural frequency of the LP turbine casing was 61.26 Hz and the excited frequency of the turbine rotor was 60.25 Hz. The manufacturing defect caused a decrease in the casing natural frequency and resulted in the high vibration of the casing because it moved close to the resonant frequency.

Prediction of nonlinear characteristics of soil-pile system under vertical vibration

  • Biswas, Sanjit;Manna, Bappaditya;Choudhary, Shiva S.
    • Geomechanics and Engineering
    • /
    • 제5권3호
    • /
    • pp.223-240
    • /
    • 2013
  • In the present study an attempt was made to predict the complex nonlinear parameters of the soil-pile system subjected to the vertical vibration of rotating machines. A three dimensional (3D) finite element (FE) model was developed to predict the nonlinear dynamic response of full-scale pile foundation in a layered soil medium using ABAQUS/CAE. The frequency amplitude responses for different eccentric moments obtained from the FE analysis were compared with the vertical vibration test results of the full-scale single pile. It was found that the predicted resonant frequency and amplitude of pile obtained from 3D FE analysis were within a reasonable range of the vertical vibration test results. The variation of the soil-pile separation lengths were determined using FE analysis for different eccentric moments. The Novak's continuum approach was also used to predict the nonlinear behaviour of soil-pile system. The continuum approach was found to be useful for the prediction of the nonlinear frequency-amplitude response of full-scale pile after introducing the proper boundary zone parameters and soil-pile separation lengths.

Sensitivity analysis of melt spinning process by frequency response

  • Hyun, Jae-Chun;Jung, Hyun-Wook;Lee, Joo-Sung
    • Korea-Australia Rheology Journal
    • /
    • 제14권2호
    • /
    • pp.57-62
    • /
    • 2002
  • The sensitivity of the final filament to the ongoing sinusoidal disturbances has been Investigated in the viscoelastic spinning using frequency response method. Amplification ratios or gains of the spinline cross-sectional area at the take-up to any disturbances show resonant peaks along the frequency regime, where the frequencies at theme points directly correspond to the imaginary parts of the successive leading eigenvalues from the linear stability analysis. As shown in Jung et al. (1999) and Lee et al (2001), the sensitivity results on the effect of various process conditions such as spinline cooling and fluid viscoelasticity, obtained by dynamic transient simulation have been corroborated in this study. That is, increasing spinline cooling makes the system less sensitive to disturbances, thus stabilizes the spinning. Also, an increasing viscoelasticity for extension-thickening fluids decreases the sensitivity of the spinning. i.e., stabilizing the system, where, as it increases the sensitivity of the spinning of extension-thinning fluids. Furthermore, it has been found in the present study that the inertia force as one of secondary forces causes the system to be more stabile or less sensitive to process disturbances.

Probabilistic and spectral modelling of dynamic wind effects of quayside container cranes

  • Su, Ning;Peng, Shitao;Hong, Ningning;Wu, Xiaotong;Chen, Yunyue
    • Wind and Structures
    • /
    • 제30권4호
    • /
    • pp.405-421
    • /
    • 2020
  • Quayside container cranes are important delivery machineries located in the most frontiers of container terminals, where strong wind attacks happen occasionally. Since the previous researches on quayside container cranes mainly focused on the mean wind load and static response characteristics, the fluctuating wind load and dynamic response characteristics require further investigations. In the present study, the aerodynamic wind loads on quayside container cranes were obtained from wind tunnel tests. The probabilistic and spectral models of the fluctuating aerodynamic loads were established. Then the joint probabilistic distributions of dynamic wind-induced responses were derived theoretically based on a series of Gaussian and independent assumption of resonant components. Finally, the results were validated by time domain analysis using wind tunnel data. It is concluded that the assumptions are acceptable. And the presented approach can estimate peak dynamic sliding force, overturning moments and leg uplifts of quayside container cranes effectively and efficiently.

초음파 금속 용착용 40kHz 혼의 설계와 용착성 평가 (Design and Weldability Verification of the 40kHz Horn for Ultrasonic Metal Welding)

  • 장호수;박우열;박동삼
    • 한국기계가공학회지
    • /
    • 제12권2호
    • /
    • pp.55-61
    • /
    • 2013
  • The horn is a key part of the ultrasonic welder. As the shape, mass and material of a horn have effects on the resonant frequency and the vibration mode in ultrasonic welding, a horn has to be designed and manufactured accurately. In this study, 40kHz band horn was designed and manufactured through the vibration mode and finite element analysis. A result of modal analysis showed that the natural frequency of the horn was 39,794Hz, and the frequency response by a harmonic response analysis was 39,800Hz - close to the intended frequency, 40kHz. In addition, weldability of the developed horn was estimated by welding of two Ni sheets and tensile-shear test of welded samples. It was shown the developed horn could be used in metal sheet welding.

Versatile UPQC Control System with a Modified Repetitive Controller under Nonlinear and Unbalanced Loads

  • Trinh, Quoc-Nam;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.1093-1104
    • /
    • 2015
  • A standard repetitive controller (RC) is theoretically able to replace a bank of resonant controllers in harmonic signals tracking applications. However, the traditional RC has some drawbacks such as a poor dynamic response and a complex structure to compensate grid frequency deviations for an effective unified power quality conditioner (UPQC) control scheme. In order to solve these problems, an improved RC with an outstanding dynamic response and a simplified grid frequency adaptive scheme is proposed for UPQC control systems in this paper. The control strategy developed for the UPQC has delay time, i.e., one-sixth of a fundamental period (Tp/6), repetitive controllers. As a result, the UPQC system can provide a fast dynamic response along with good compensation performance under both nonlinear and unbalanced loads. Furthermore, to guarantee the excellent performance of the UPQC under grid frequency deviations, a grid frequency adaptive scheme was developed for the RC using a simple first order Padé's approximation. When compared with other approaches, the proposed control method is simpler in structure and requires little computing time. Moreover, the entire control strategy can be easily implemented with a low-cost DSP. The effectiveness of the proposed control method is verified through various experimental tests.

사용중 시간영역응답을 이용한 손상탐지이론의 검증 (Verification of Damage Detection Using In-Service Time Domain Response)

  • 최상현;김대혁;박남회
    • 한국방재학회 논문집
    • /
    • 제9권5호
    • /
    • pp.9-13
    • /
    • 2009
  • 현재까지 구조건전성 모니터링과 관련하여 제안된 대부분의 손상인식기법은 모달영역응답을 이용하고 있으나, 모달영역응답은 별도의 후처리가 필요하며 추출과정에서 오차를 포함하게 되므로 손상인식의 정확성을 저하시키는 요인이 되어왔다. 본 논문에서는 이동하중응답을 직접 이용하는 손상인식기법의 적용성을 실내 실험을 통하여 검증하였다. 실험은 강재로 만든 보에 이동하중을 재하시켜 수행하였으며, 보의 응답은 변위계를 이용하여 측정하였다. 이동하중은 쇠구슬과 활강장치를 이용하여 모사하였으며, 주기성과 비주기성 이동하중으로 구분하여 재하하였다. 계측된 응답을 이용한 손상인식 결과, 이동하중을 이용한 손상인식기법은 구조물의 손상을 성공적으로 탐지하는 것으로 나타났다.

Concept Design of a Parallel-type Tuned Mass Damper - Tuned Sloshing Damper System for Building Motion Control in Wind

  • Lee, Chien-Shen;Love, J. Shayne;Haskett, Trevor C.;Robinson, Jamieson K.
    • 국제초고층학회논문집
    • /
    • 제10권2호
    • /
    • pp.93-97
    • /
    • 2021
  • Supplementary damping systems, such as tuned mass dampers (TMDs) and tuned sloshing dampers (TSDs) - also known as tuned liquid dampers (TLDs) - have been successfully employed to reduce building motion during wind events. A design of a damping system consisting of a TMD and two TSDs performing in unison has been developed for a tall building in Taiwan to reduce wind-induced motion. The architecturally exposed TMD will also be featured as a tourist attraction. The dual-purpose TSD tanks will perform as fire suppression water storage tanks. Linearized equivalent mechanical TSD and TMD models are coupled to the structure to simulate the multi-degree of freedom system response. Frequency response curves for the structure with and without the damping system are created to evaluate the performance of the damping system. The performance of the combined TMD-TSD system is evaluated against a conventional TMD system by computing the effective damping produced by each system. The proposed system is found to have superior performance in acceleration reduction. The combined TMD-TSD system is an effective and affordable means to reduce the wind-induced resonant response of tall buildings.