• Title/Summary/Keyword: resonance test

Search Result 986, Processing Time 0.029 seconds

Evaluation of TOF MR Angiography and Imaging for the Half Scan Factor of Cerebral Artery (유속신호증강효과의 자기공명혈관조영술을 이용한 뇌혈관검사에서 Half Scan Factor 적용한 영상 평가)

  • Choi, Young Jae;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.92-98
    • /
    • 2016
  • To aim of this study was to assess the full scan and half scan of imaging with half scan factor. Patients without a cerebral vascular disease (n = 30) and were subject to the full scan half scan, and set a region of interest in the cerebral artery from the three regions (C1, C2, C3) in the range of 7 to 8 mm. MIP (maximum intensity projection) to reconstruct the images in signal strength SNR (signal to noise ration), PSNR (peak signal noise to ratio), RMSE (root mean square error), MAE (mean absolute error) and calculated by paired t-test for use by statistics were analyzed. Scan time was half scan (4 minutes 53 seconds), the full scan (6 minutes 04 seconds). The mean measurement range (7.21 mm) of all the ROI in the brain blood vessel, was the SNR of the first C1 is completely scanned (58.66 dB), half-scan (62.10 dB), a positive correlation ($r^2=0.503$), for the second C2 SNR is completely scanned (70.30 dB), half-scan (74.67 dB) the amount of correlation ($r^2=0.575$), third C3 of a complete scan SNR (70.33 dB), half scan SNR (74.64 dB) in the amount of correlation between the It was analyzed with ($r^2=0.523$). Comparative full scan with half of SNR ($4.75{\pm}0.26dB$), PSNR ($21.87{\pm}0.28dB$), RMSE ($48.88{\pm}1.61$), was calculated as MAE ($25.56{\pm}2.2$). SNR is also applied to examine the half-scans are not many differences in the quality of the two scan methods were not statistically significant in the scan (p-value > .05) image takes less time than a full scan was used.

Evaluation of Glioma with Thallium-201 Brain SPECT: The Correlation with $^1H$ MR Spectroscopy and Pathology ($^{201}Tl$ 뇌 SPECT을 이용한 신경교종의 평가)

  • Sohn, Hyung-Sun;Kim, Euy-Neyng;Kim, Sung-Hoon;Yoo, Ie-Ryung;Chung, Yong-An;Chung, Soo-Kyo;Hong, Yong-Gil;Lee, Youn-Soo;Choe, Bo-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.465-477
    • /
    • 2000
  • Purpose: Thallim-201 ($^{201}Tl$) brain SPECT and proton ($^1H$) magnetic resonance spectroscopy (MRS) have been used to evaluate tumor grade and viability of glioma. We assessed the correlations between $^{201}Tl$ brain index or spectrum of metabolites of $^1H$ MRS and grade of glioma or histopathologic findings. Materials and Methods: We studied 17 patients (4 astrocytoma, 7 anaplastic astrocytoma and 6 glioblastoma). On $^{201}Tl$ Brain SPECT, $^{201}Tl$ index was measured as the ratio of average counts for region of interest to those for the contralateral normal brain. On $^1H$ MRS, we calculated choline (Cho) /creatine (Cr) ratio and N-acetylaspartate (NAA)/Cr ratio in ROI defined as tumor center. Histopathologic findings were graded by Ki-67 index, cellularity, mitosis, pleomorphism, necrosis and endothelial proliferation. An unpaired t test and statistical correlations were performed to evaluate these data. Results: Tl-index showed the best correlation with Ki-67 index (p<0.01), less correlations with cellularity, mitosis, and endothelial proliferation, but no correlation with results of MRS, pleomorphism, or necrosis. The findings of MRS did not correlate with all of the above. The cases of glioblastoma demonstrated a higher Tl-index, Cho/cr ratio, Ki-67 index and lower NAA/Cr ratio, albeit without statistical significance. Conclusion: Even though $^{201}Tl$ brain SPECT did not correlate directly with grade of malignancy, it may still be useful in determining biological aggressiveness of tumor and prognosis of patients because it correlated well with Ki-67 index, a growth fraction of glioma, cellularity, mitosis and endothelial proliferation.

  • PDF

The Effect of Exercise on Pulmonary Function (운동이 폐기능에 미치는 영향)

  • Park, Jae-Seuk;Kim, Youn-Seup;Choi, Eun-Kyoung;Jee, Young-Koo;Lee, Kye-Young;Kim, Keun-Youl;Chun, Yong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.351-359
    • /
    • 1998
  • Background: The effects of exercise on pulmonary function are complex and have been the subject of many investigations. But, there has been disputes about the effect of exercise on spirometric parameters and there is no study about the effect of exercise on IOS(Impulse Oscillometry)parameters. IOS, a new method of pulmonary function test, is based on the relationship between the pressure and flow oscillation which is produced by applying sinusoidal pressure oscillation to the respiratory system via the mouth. Method: Fifty-nine young adults without respiratory symptoms were divided into three groups according to degree of exercise(hard exercise group: mean exercise time is over three hours per week at least for the last one month, light exercise group : between thirty minutes to three hours, nonexercise group : less than thirty minutes) and undertaken pulmonary function test(simple spirometry and IOS). Results: The effects of exercise on spirometric parameters; percentage of predictive value of forced vital capacity(FVC % pred) was higher in hard exercise group than nonexercise group(hard exercise group: $102.4{\pm}14.8$, nonexercise group: $93.7{\pm}9.9$, p=0.017), but there was no significant difference in percentage of predicted value of forced expiratory volume in one second(FEV 1 % pred) and percentage of predicted value of forced expiratory flow 50% (FEF 50% pred) between groups. The effects of exercise on IOS parameters: Reactance at 5Hz(X5) was significantly lower in hard exercise group than nonexercise group(hard exercise group: $-0.166{\pm}0.123hPa/1/s$, nonexercise group: $-0.093{\pm}0.036hPa/1/s$, p=0.006) but there was no significant difference in central resistance(Rc), peripheral resistance(Rp), resonance frequency(RF) and resistance at 5Hz, 20Hz between groups. Conclusion: Hard exercise increased FVC % pred on spirometric parameters and decreased reactance at 5Hz(X5) on IOS parameters.

  • PDF

Study on Volume Measurement of Cerebral Infarct using SVD and the Bayesian Algorithm (SVD와 Bayesian 알고리즘을 이용한 뇌경색 부피 측정에 관한 연구)

  • Kim, Do-Hun;Lee, Hyo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.591-602
    • /
    • 2021
  • Acute ischemic stroke(AIS) should be diagnosed within a few hours of onset of cerebral infarction symptoms using diagnostic radiology. In this study, we evaluated the clinical usefulness of SVD and the Bayesian algorithm to measure the volume of cerebral infarction using computed tomography perfusion(CTP) imaging and magnetic resonance diffusion-weighted imaging(MR DWI). We retrospectively included 50 patients (male : female = 33 : 17) who visited the emergency department with symptoms of AIS from September 2017 to September 2020. The cerebral infarct volume measured by SVD and the Bayesian algorithm was analyzed using the Wilcoxon signed rank test and expressed as a median value and an interquartile range of 25 - 75 %. The core volume measured by SVD and the Bayesian algorithm using was CTP imaging was 18.07 (7.76 - 33.98) cc and 47.3 (23.76 - 79.11) cc, respectively, while the penumbra volume was 140.24 (117.8 - 176.89) cc and 105.05 (72.52 - 141.98) cc, respectively. The mismatch ratio was 7.56 % (4.36 - 15.26 %) and 2.08 % (1.68 - 2.77 %) for SVD and the Bayesian algorithm, respectively, and all the measured values had statistically significant differences (p < 0.05). Spearman's correlation analysis showed that the correlation coefficient of the cerebral infarct volume measured by the Bayesian algorithm using CTP imaging and MR DWI was higher than that of the cerebral infarct volume measured by SVD using CTP imaging and MR DWI (r = 0.915 vs. r = 0.763 ; p < 0.01). Furthermore, the results of the Bland Altman plot analysis demonstrated that the slope of the scatter plot of the cerebral infarct volume measured by the Bayesian algorithm using CTP imaging and MR DWI was more steady than that of the cerebral infarct volume measured by SVD using CTP imaging and MR DWI (y = -0.065 vs. y = -0.749), indicating that the Bayesian algorithm was more reliable than SVD. In conclusion, the Bayesian algorithm is more accurate than SVD in measuring cerebral infarct volume. Therefore, it can be useful in clinical utility.

A study on image distortion improvement using silicon device in thyroid diffusion MRI images (갑상선의 확산강조영상 검사 시 실리콘 이용한 뒤틀림 감소에 관한 연구)

  • Choi, Kwan-Woo;Seo, Dae-Keon;Lee, Ho-Beom;Goh, Hee-Jin;Na, Sa-Ra;Han, Dong-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4380-4386
    • /
    • 2014
  • This study was conducted to minimize the imaging distortion by reducing the differences in susceptibility between the tissue and air surrounding it while performing a thyroid diffusion imaging procedure. The study group was composed of 23 healthy adults. Thyroids with many distortions near the air, larynx, and trachea were chosen to test and evaluate the diffusion imaging difference between before and after an application of silicon. As a result, there was reduced distortion with silicon application, and the differences decreased from 30% to 10%. According to One-way ANOVA and Duncan's post-hoc test, there were no significant differences between imaging with a silicon application and T2 imaging of the surface area, which was the standard image. In conclusion, this study presented a radical improvement in reducing the distortions in imaging by compensating for an uneven tissue surface near air without affecting the magnetic resonance contrast and complicating the imaging processes.

Preparation of Isophorone Diisocyanate-loaded Microcapsules and Their Application to Self-healing Protective Coating (Isophorone Diisocyanate 함유 마이크로캡슐의 제조와 자기치유형 보호코팅재에의 응용)

  • Lim, Ye-Ji;Song, Young-Kyu;Kim, Dong-Min;Chung, Chan-Moon
    • Polymer(Korea)
    • /
    • v.39 no.1
    • /
    • pp.56-63
    • /
    • 2015
  • The object of this study is to prepare microcapsules containing a diisocyanate compound, apply them to self-healing protective coating, and evaluate the self-healing capability of the coating by atmospheric moisture. Isophorone diisocyanate (IPDI) polymerized under humid atmosphere, indicating that IPDI can be used as a healing agent. Microencapsulations of IPDI were conducted via interfacial polymerization of a polyurethane prepolymer with diol compounds. The formation of microcapsules was confirmed by Fourier-transform infrared (FTIR) spectroscopy and nuclear magnetic resonance (NMR) spectroscopy. The mean diameter, size distribution, morphology and shell wall thickness of microcapsules were investigated by optical microscopy and scanning electron microscopy (SEM). The properties of microcapsules were studied by varying agitation rates and diol structure. The self-healing coatings were prepared on test pieces of CRC board. When scratch was generated in the coatings, the core material flew out of the microcapsules and filled the scratch. The self-healing coatings were damaged and healed under atmosphere with 68~89% relative humidity for 48 h, and SEM and impermeability test for the specimens showed that the scratch could be healed by atmospheric moisture.

Research fecal metabolite according to fed different ratios of roughage to concentrate on lactating cow using 1H-NMR analysis (조사료와 농후사료 급여비율에 따른 젖소 우분의 대사체 탐색)

  • Kim, Hyun Sang;Lee, Shin Ja;Eom, Jun Sik;Lee, Sung Sill
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.432-439
    • /
    • 2020
  • This study examined the metabolites in different roughage to concentrate ratios using proton nuclear magnetic resonance spectroscopy (1H-NMR). Six lactating cows were divided into two groups that were fed different roughage to concentrate ratios (HR group = 8:2, HC group = 2:8). Feces samples were collected individually at one time, and the metabolites were analyzed using an SPE-800 MHz NMR-MS system. The metabolites were identified and quantified using a Chenomx NMR suite 8.4. Metabolic pathway analysis and principal component analysis were conducted using a Metaboanalyst 4.0. Statistical analysis was performed using a Dunnett's test on the SAS program. As a result, several metabolites were identified, and among them, 77 metabolites were used in statistical analysis. The levels of twelve metabolites were significantly higher in the HC group: succinate, dimethylamine, histamine, homovanillate, thymol, acetate, propionate, butyrate, isovalerate, valerate, imidazole, N-nitrosodimethylamine, and O-acetylcholine. In the HC group, the concentrations of all metabolites were higher than in the HR group, and the metabolic pathway was also different. This study is expected to be useful for a variety of livestock studies by 1H-NMR because it examined the change in metabolites in the body metabolism and microorganisms.

Comparative Study between MRI and pain, duration, physical examination in 20 patients with knee joint pain (20례 슬통환자의 통증, 이환기간, 물리적 검사법과 MRI소견과의 비교 고찰)

  • Yang, Myung-bok;Jang, Byung-sun;Lee, Dae-yong;Lee, Seung-hoon;Hwang, Byung-chun;Park, Jung-un;Guk, Ui-suk;Lee, Geon-mok
    • Journal of Acupuncture Research
    • /
    • v.19 no.6
    • /
    • pp.221-233
    • /
    • 2002
  • Background and Purpose : MRI(Magnetic Resonance Imaging) has become one of the most sensitive diagnostic tool no evaluate problems of the knee, because it enables us to identify not only osseous tissue but also soft tissues including muscle, fascia, tendon, ligament, meniscus and fat around the knee joint. Objective : To compare between MRI reading and pain, duration, physical examination in patients with pain of knee joint. Methods : 20 patients with pain of knee joint included in this study. This study researched pain-degree, duration, physical examination with pain of knee joint. Using MRI(Horizon Lx 1.0T-GE), we obtained the results. Results : 1. In the distribution of sex; Female rate was 80.0% and male rate was 20.0%. In the distribution of age, above sixty group was the largest group by each 55.0%. 2. In the distribution of MRI reading; 'Meniscus horm tear' was 70.0%, 'Osteoarthritis' was 55.5%, 'ACL partial tear' was 15.0%, 'Bone bruise at tibia, femur' was 15.0%. 3. Correlation between duration of pain and MRI reading showed that acute and subacute stage related various MRI reading, that chronic stage related 'Osteoarthritis' and 'Meniscus horn tear' by each 69.2%, 92.3%. 4. Correlation between pain and MRI reading showed that severe pain(GVI) related 'ACL partial tear, PCL partial tear' by each 100%, that mild pain(GII) related 'Osteoarthritis, Meniscus horn tear' by each 70.0%, 80.0%. 5. Correlation between physical examination and MRI reading showed that Drawer test related ACL partial tear by each 60.0%, that McMurray test related 'Meniscus horn tear' by each 75.0%. 6. Correlation between effect of treatment and MRI reading showed that 'Osteoarthritis, Meniscus horn tear' related good effect, that ACL partial tear related poor effect. Conclusions : These results suggest that acute and sever pain relate 'ACL partial tear, PCL partial tear', that chronic and mild pain related 'Osteoarthritis, Meniscus horn tear'. So it is responsibility to use MRI as a sensitive diagnostic tool in the knee problems.

  • PDF

Physical and Chemical characteristics of Cokes Using Ash-Free Coal as binder (무회분 석탄(AFC)을 바인더로 이용한 코크스의 물리적 및 화학적 특성)

  • Kim, Gyeong Min;Kim, Jin Ho;Lisandy, Kevin Yohanes;Kim, Gyu Bo;Choi, Ho Kyung;Jeon, Chung Hwan
    • Korean Chemical Engineering Research
    • /
    • v.55 no.3
    • /
    • pp.395-400
    • /
    • 2017
  • Coke strength was increased by adding ash-free coal (AFC) binder. In this study, the effect of the AFC binder on the physical and chemical properties of coke was experimentally investigated to understand the molecular mechanism for the improved coke strength. For reduced $CO_2$ emission in steelmaking industry, torrefied biomass fuel mixed with coal binder is also considered. The interface between the base coal and AFC was thus examined using Scanning Electron Microscope (SEM). The coke strength was commonly measured by performing the indirect tensile test and Nuclear Magnetic Resonance (NMR) spectroscopy in $^1H$ and $^{13}C$ modes. For comprehensive mechanism study of the enhanced coke strength thus obtained, ordinary coal for thermal power plant use was carbonized with AFC for subsequent SEM examination. The NMR spectroscopy results of coke samples positively revealed that the tensile strength was proportional to the average number of aromatic rings.

Diffuse Hepatic Uptake of $^{99m}Tc$-DPD on Whole Body Bone Scan: The Influence of MRI Contrast (전신 뼈 검사에서 $^{99m}Tc$-DPD의 미만성 간 섭취: MRI 조영제의 영향)

  • Yun, Jong Jun;Jeong, Ji Uk;Hwang, Ju Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.57-61
    • /
    • 2012
  • Purpose : The whole body bone scan on nuclear medicine is a widely accepted examination and procedure. However, unusual nonosseous uptake can be observed, which reflects a rare interaction between the radiopharmacceutical and the patient. This study aimed to evaluate the influence of MRI(Magnetic Resonance Imaging) contrast and $^{99m}Tc$-DPD(Dicarboxpropane diphosphonate) on whole body bone scan. Materials and Methods : We analyzed the 982 patients who were examined by $^{99m}Tc$-DPD on whole body bone scan in nuclear medicine department of pusan national university hospital from january to december 2010. All these 982 patients had MRI contrast administration prior to whole body bone scan. We analyzed laboratory test. Results : 46 patients(men 39, women 7) showed diffuse hepatic uptake on whole body bone scan. These uptakes were disappeared on the follow-up whole body bone scan. There were no significant difference of CBC test, liver function tests and renal function tests. Conclusion : The study might be an indirect evidence that diffuse hepatic and splenic uptake of 99mTc-DPD on whole body bone scan after intravenous administration of Gadolinium(Gd) MRI contrast. To perform a precise examination, Gd-contrast agent should be removed from the body before performing a whole body bone scan.

  • PDF