• 제목/요약/키워드: resonance evaluation

검색결과 834건 처리시간 0.026초

Evaluation of Antioxidant Activities and Active Compounds Separated from Water Soluble Extracts of Korean Black Pine Barks

  • Shen, Chang-Zhe;Jun, Hong-Young;Choi, Sung-Ho;Kim, Young-Man;Jung, Eun-Joo;Oh, Gi-Su;Joo, Sung-Jin;Kim, Sung-Hyun;Kim, Il-Kwang
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권12호
    • /
    • pp.3567-3572
    • /
    • 2010
  • Black pine barks from the southern region of Korea were extracted using pressurized hot water and the water soluble extracts were then separated in a stepwise fashion using a variety of solvents, column chromatography (CC), thin layer chromatography (TLC), and high pressure liquid chromatography (HPLC). The antioxidant activities of each fraction and the active compounds were determined based on the radical scavenging activities of 2,2-diphenyl-1-picrylhydrazyl (DPPH), reductive potential of ferric ion, and total phenol contents. A DPPH test showed that the half maximal effective concentration ($EC_{50}$ value : $6.59{\pm}0.31\;{\mu}g/mL$) of the ethyl acetate fraction (ca. 0.67%) was almost the same as that of the control compounds and inversely proportional to the value of the total phenol contents. The cell viability of the water extracts was confirmed by methyl thiazol-2-yl-2,5-diphenyl tetrazolium bromide (MTT) with enzyme linked immune sorbent assay (ELISA). Catechin, epicatechin, quercetin and ferulic acid were isolated from the ethyl acetate fraction as active compounds and identified by nuclear magnetic resonance. The antioxidant activity as value of DPPH of each of the separated compounds was lower than the ethyl acetate fraction, and ferulic acid was the lowest among these compounds.

연소안정성을 평가하기 위한 일렬형 다중 인젝터로 구성된 헤드의 매니폴드 유동해석 (Flow Analysis of a Engine Manifold with Multiple Injectors Arranged in a Row for Evaluation of Combustion Stability)

  • 최지선;유이상;신동해;박진수;고영성;김선진
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.622-627
    • /
    • 2017
  • 본 연구에서는 실물형 연소기와 동일한 연소 및 음향 공진 조건을 가질 수 있는 축소형 모델 연소기의 추진제 공급부 매니폴드의 수치해석을 진행하였다. 비원통형 연소기의 형상을 고려한 일렬형 다중 인젝터로 구성된 헤드를 대상으로 해석하였으며 매니폴드의 형상과 유입유로의 개수 및 형태에 따라 해석결과를 분석했다. 메인추진제의 매니폴드 형태는 재순환영역이 적고 제작이 용이할 수 있게 원형으로 구성하였다. 액체산소는 유동을 균일하게 공급하기 위해 distributor를 구성하였고 케로신은 직접 화염면이 닿는 곳이기 때문에 재순환영역을 최대한 줄이도록 방사형 $360^{\circ}$로 유입유로를 구성하였다. 액체질소 매니폴드는 분사기 근처의 속도차이를 줄이고자 방사형 유입유로로 구성하였다.

  • PDF

Effects of Size and Permittivity of Rat Brain on SAR Values at 900 MHz and 1,800 MHz

  • Hyun Jong-Chul;Oh Yi-Sok
    • Journal of electromagnetic engineering and science
    • /
    • 제6권1호
    • /
    • pp.47-52
    • /
    • 2006
  • The objective of this study is to evaluate the effects of size and permittivity on the specific absorption rate(SAR) values of rat brains during microwave exposure at mobile phone frequency bands. A finite difference time domain (FDTD) technique with perfect matching layer(PML) absorbing boundaries is used for this evaluation process. A color coded digital image of the Sprague Dawley(SD) rat based on magnetic resonance imaging(MRI) is used in FDTD calculation with appropriate permittivity values corresponding to different tissues for 3, 4, 7, and 10 week old rats. This study is comprised of three major parts. First, the rat model structure is scaled uniformly, i.e., the rat size is increased without change in permittivity. The simulated SAR values are compared with other experimental and numerical results. Second, the effect of permittivity on SAR values is examined by simulating the microwave exposure on rat brains with various permittivity values for a fixed rat size. Finally, the SAR distributions in depth, and the brain-averaged SAR and brain 1 voxel peak SAR values are computed during the microwave exposure on a rat model structure when both size and permittivity have varied corresponding to different ages ranging from 3 to 10 weeks. At 900 MHz, the simulation results show that the brain-averaged SAR values decreased by about 54 % for size variation from the 3 week to the 10 week-old rat model, while the SAR values decreased only by about 16 % for permittivity variation. It is found that the brain averaged SAR values decreased by about 63 % when the variations in size and permittivity are taken together. At 1,800 MHz, the brain-averaged SAR value is decreased by 200 % for size variation, 9.7 % for permittivity variation, and 207 % for both size and permittivity variations.

Evaluation of an Experimentally Designed Stereotactic Guidance System for Determining Needle Entry Point during Uniplanar Fluoroscopy-guided Intervention

  • Lee, Jae-Heon;Jeon, Gye-Rok;Ro, Jung-Hoon;Byoen, Gyeong-Jo;Kim, Tae-Kyun;Kim, Kyung-Hoon
    • The Korean Journal of Pain
    • /
    • 제25권2호
    • /
    • pp.81-88
    • /
    • 2012
  • Background: In discography performed during percutaneous endoscopic lumbar discectomy (PELD) via the posterolateral approach, it is difficult to create a fluoroscopic tunnel view because a long needle is required for discography and the guide-wire used for consecutive PELD interrupts rotation of fluoroscope. A stereotactic system was designed to facilitate the determination of the needle entry point, and the feasibility of this system was evaluated during interventional spine procedures. Methods: A newly designed stereotactic guidance system underwent a field test application for PELD. Sixty patients who underwent single-level PELD at L4-L5 were randomly divided into conventional or stereotactic groups. PELD was performed via the posterolateral approach using the entry point on the skin determined by premeasured distance from the midline and angles according to preoperative magnetic resonance imaging (MRI) findings. Needle entry accuracy provided by the two groups was determined by comparing the distance and angle measured by postoperative computed tomography with those measured by preoperative MRI. The duration and radiation exposure for determining the entry point were measured in the groups. Results: The new stereotactic guidance system and the conventional method provided similarly accurate entry points for discography and consecutive PELD. However, the new stereotactic guidance system lowered the duration and radiation exposure for determining the entry point. Conclusions: The new stereotactic guidance system under fluoroscopy provided a reliable needle entry point for discography and consecutive PELD. Furthermore, it reduced the duration and radiation exposure associated with determining needle entry.

Evaluation of the cross-sectional area of acromion process for shoulder impingement syndrome

  • Joo, Young;Cho, Hyung Rae;Kim, Young Uk
    • The Korean Journal of Pain
    • /
    • 제33권1호
    • /
    • pp.60-65
    • /
    • 2020
  • Background: Anatomic changes in the acromion have been considered a main cause of shoulder impingement syndrome (SIS). To evaluate the relationship between SIS and the acromion process, we devised a new morphological parameter called the acromion process cross-sectional area (APA). We hypothesized that the APA could be an important morphologic diagnostic parameter in SIS. Methods: We collected APA data from 95 patients with SIS and 126 control subjects who underwent shoulder magnetic resonance imaging (MRI). Then we measured the maximal cross-sectional area of the bone margin of the acromion process on MRI scans. Results: The mean of APAs were 136.50 ± 21.75 ㎟ in the male control group and 202.91 ± 31.78 ㎟ in the male SIS group; SIS patients had significantly greater APAs (P < 0.001). The average of APAs were 105.38 ± 19.07 ㎟ in the female control group and 147.62 ± 22.90 ㎟ in the female SIS group, and the SIS patients had significantly greater APAs (P < 0.001). The optimal APA cut-off in the male group was 165.14 ㎟ with 90.2% sensitivity, 91.4% specificity, and an area under the curve (AUC) of 0.968. In the female group, the optimal cut-off was 122.50 ㎟ with 85.2% sensitivity, 84.9% specificity, and an AUC of 0.928. Conclusions: The newly devised APA is a sensitive parameter for assessing SIS; greater APA is associated with a higher possibility of SIS. We think that this result will be helpful for the diagnosis of SIS.

Usefulness of $^{11}C-Methyl-L-and$ D-Methionine PET in Gliomas : with Special Attention to Recurrence

  • Cho, Won-Sang;Kim, Chi-Heon;Kim, Jeong-Eun;Chung, June-Key;Paek, Sun-Ha;Jung, Hee-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제39권3호
    • /
    • pp.176-182
    • /
    • 2006
  • Objective : This study concernes the usefulness of $^{11}C-methyl-L-and$ D-methionine[Met]-positron emission tomography[PET] for glioma grading and detection of recurrence in gliomas, compared with fluorine-18, 2-fluoro-deoxyglucose[FDG]-PET. Methods : Eighty patients underwent Met-PET study for evaluation of glioma : 37 astrocytomas [WHO grade II, 3; III, 8; IV, 26]. 27 oligodendrogliomas [WHO grade II, 16; III, 11]. and 12 suspicious recurrent gliomas. All images were taken within 2 weeks before operation. For suspicious recurrent cases on magnetic resonance images, both FDG-PET and Met-PET were performed. Results : In astrocytoma, Mean maximum standard uptake value[SUV] of region of interest[ROI] was not different between WHO grades [p=0.108]. but ROI/normal contralateral tissue SUV [T/N] ratio was statistically different between WHO grades [p=0.002]. T/N ratio was more closely related to visual scale than maximum SUV of ROI [p<0.001 and p=0.107 respectively]. In oligodendroglioma, there was no statistical difference between WHO grades in view of maximum SUV and T/N ratio. For recurrent gliomas, sensitivity of FDG-PET and Met-PET was 25% and 100%, while specificity of FDG-PET and Met-PET were 100% and 80%, respectively. Conclusion : Met-PET might be an appropriate tool for tumor grading in astrocytoma and be more sensitive for detection of recurrence in gliomas than FDG-PET.

악관절 내장증 환자에서 자기공명영상사진상의 관절원판 형태의 평가 (Magnetic Resonance Evaluation of the Articular Disc Configuration in the Patients with Internal Derangement of the Temporomandibular Joint)

  • 김귀애;김선희;기우천;최재갑
    • Journal of Oral Medicine and Pain
    • /
    • 제25권3호
    • /
    • pp.305-313
    • /
    • 2000
  • 이 연구의 목적은 악관절 내장증 환자에서 관절원판의 형태를 자기공명영상사진으로 평가하고 임상적 증상과의 관계를 알아보고자 하는 것이다. 악관절 내장증의 증상을 가진 90명의 환자에서 169개의 관절을 자기공명영상사진으로 관절원판과 하악과두의 관계를 기준으로 정상군, 정복성 관절원판 변위군, 비정복성 관절원판 변위군으로 분류하고 관절원판의 형태를 5가지로 나누었다. 임상검사는 측두하악관절통과 관절음의 유무를 확인하여 그 상관관계를 알아보았다. 실험 결과에서 측두하악관절통은 각 군에서 관절원판의 형태와는 정상군을 제외하고는 통계적인 유의성이 없었으며, 염증성 삼출액과 유의한 관계를 보였다. 관절음은 정복성 관절원판 변위환자에서 관절원판형태와 통계적으로 유의성을 보였으며, 비정복성 관절원판 변위환자에서도 상당수 관절음이 발생하였음을 알 수 있었다. 이 결과는 측두하악관절의 통증은 관절원판의 형태가 많이 변형될수록 통증이 심해지는 경우가 많았지만, 다른 여러 가지 원인들이 존재할 수 있으며, 관절음은 정복성 관절원판 변위환자에서 관절원판의 변형이 심할수록 관절원판이 정복할 때 발생될 수 있다는 것을 의미한다. 따라서, 임상적인 검사와 더불어 자기공명영상사진으로 정확한 진단을 함으로써 관절원판 변위의 적절한 치료가 행해질수 있으리라 생각된다.

  • PDF

방사선(放射線)으로 조사(照射)된 Polyvinylchloride의 내방사성(耐放射性) 전기전도도(電氣傳導度)에 가소제(可塑劑)가 미치는 영향(影響) (Effects of Plasticizer to Radioresistance and Electrical Conductivity of Irradiated Polyvinylchlorde)

  • 김봉흡
    • Journal of Radiation Protection and Research
    • /
    • 제3권1호
    • /
    • pp.23-28
    • /
    • 1978
  • 유기석계(有機錫系) 안정제(安定劑)를 포함하고 있는 polyvinylchloride (PVC)의 내방사성(耐放射性)은 가소제(可塑劑)로서 첨가된 dioctylphthalate(DOP)의 양의 증가와 더부러 증가하며 이와 같은 내방사성(耐放射性)의 평가는 시료의 IR 특성 상에서 안정제의 해이(解離)에 기인(起因)하고 있는 $1,540{\sim}1,640cm^{-1}$에서의 흡수대가 선량과 더부러 변화하는 거동으로 살필 수 있다. 가소화된 PVC에서의 내방사성의 증가는 DOP 분자구조의 일부를 형성하는 benzen 환(環)에서 방사 에너지가 공명흡수 되기 때문이라 사료(思料)되며 이와 같은 견해(見解)는 방사선량에 대한 도전율변화특성(導電率變化特性)의 고찰 결과와도 잘 일치 한다. 실용적면(實用的面)에서 $0{\sim}100Mrad$ 사이의 선량에 대한 충분(充分)한 내방사성(耐放射性)을 얻기 위하여는 30phr 전후의 DOP 첨가량이 필요하다.

  • PDF

PSL과 ESR 분석에 의한 건조수산물의 방사선 조사 여부 판별 특성 연구 (Detection Properties of Irradiated Dried Seafoods Using PSL and ESR)

  • 송범석;한인준;윤영민;최수정;김재경;박종흠;정일윤;이주운;김병근;김규헌;김재훈
    • 방사선산업학회지
    • /
    • 제6권2호
    • /
    • pp.119-123
    • /
    • 2012
  • The detection properties of gamma-irradiated (0~10 kGy) dried seaweed, dried shrimp, and seasoned dried filefish were investigated by photo-stimulated luminescence (PSL) and electron spin resonance (ESR). PSL could be used as a detection method on irradiated dried seaweed and dried shrimp as they showed photon counts greater than 5,000 counts/60 s (positive) in the irradiated samples with doses above l kGy. However, PSL could not be applied to detect irradiated seasoned dried filefish, because gamma-irradiated sample at 10 kGy even yielded photon counts less than 700 counts/60 s (negative). The ESR spectroscopy for only dried shrimp revealed specific signals derived from free radicals captured in the shell of shrimp. As a result, it is considered that PSL or ESR methods for detection of gamma-irradiated dried shrimp and only PSL can be used to detect gamma-irradiated seaweed. Furthermore, it is considered that hydrocarbon analysis of seasoned dried filefish containing fat by GC/MS and Thermo Luminance (TL) analysis of dried seaweed should be studied for detection of irradiation.

The association between pain, balance, fall, and disability in patients with lumbar spinal stenosis with vascular claudication

  • Gunes, Musa;Ozmen, Tarik;Guler, Tugba Morali
    • The Korean Journal of Pain
    • /
    • 제34권4호
    • /
    • pp.471-478
    • /
    • 2021
  • Background: The effect of lumbar spinal stenosis (LSS) and peripheral vascular disease (PVD), which occurs with similar degenerative conditions, when seen together, has not been studied. The aim of this study is to examine and compare the relationship between pain, balance, disability, fear of falling, and kinesiophobia in LSS patients with intermittent vascular claudication (IVC). Methods: Seventy-two patients diagnosed with LSS using magnetic resonance imaging participated in this study. Thirty-five patients with IVC symptoms and showing vascular lesions by lower extremity venous and arterial Doppler ultrasonography imaging were included in the IVC-LSS group. The pain, static balance, dynamic balance, disability, fear of falling, and kinesiophobia were evaluated using the numeric rating scale, single leg stance test, Time Up and Go (TUG), the Oswestry Disability Index (ODI), Fall Efficacy Scale-International (FES-I), and Tampa Scale for Kinesiophobia (TSK), respectively. Results: Age and female sex were found to be higher in the IVC-LSS group (P = 0.024; P = 0.012). The IVC-LSS group had a shorter single leg stance time and TUG test duration, pain intensity, ODI, FES-I, and TSK scores were higher than patients with LSS (P = 0.001). Pain, fear of falling, and kinesiophobia were moderately correlated with disability in the IVC-LSS group. No relationship was found between pain and dynamic balance. Also, the pain was not related to kinesiophobia. Conclusions: The findings indicated that IVC causes loss of balance and an increase in pain, disability, fear of falling, and kinesophobia in patients with LSS.