• 제목/요약/키워드: resolution methods

검색결과 2,222건 처리시간 0.053초

Two new triterpenoid saponins derived from the leaves of Panax ginseng and their antiinflammatory activity

  • Li, Fu;Cao, Yufeng;Luo, Yanyan;Liu, Tingwu;Yan, Guilong;Chen, Liang;Ji, Lilian;Wang, Lun;Chen, Bin;Yaseen, Aftab;Khan, Ashfaq A.;Zhang, Guolin;Jiang, Yunyao;Liu, Jianxun;Wang, Gongcheng;Wang, Ming-Kui;Hu, Weicheng
    • Journal of Ginseng Research
    • /
    • 제43권4호
    • /
    • pp.600-605
    • /
    • 2019
  • Background: The leaves and roots of Panax ginseng are rich in ginsenosides. However, the chemical compositions of the leaves and roots of P. ginseng differ, resulting in different medicinal functions. In recent years, the aerial parts of members of the Panax genus have received great attention from natural product chemists as producers of bioactive ginsenosides. The aim of this study was the isolation and structural elucidation of novel, minor ginsenosides in the leaves of P. ginseng and evaluation of their antiinflammatory activity in vitro. Methods: Various chromatographic techniques were applied to obtain pure individual compounds, and their structures were determined by nuclear magnetic resonance and high-resolution mass spectrometry, as well as chemical methods. The antiinflammatory effect of the new compounds was evaluated on lipopolysaccharide-stimulated RAW 264.7 cells. Results and conclusions: Two novel, minor triterpenoid saponins, ginsenoside $LS_1$ (1) and 5,6-didehydroginsenoside $Rg_3$ (2), were isolated from the leaves of P. ginseng. The isolated compounds 1 and 2 were assayed for their inhibitory effect on nitric oxide production in LPS-stimulated RAW 264.7 cells, and Compound 2 showed a significant inhibitory effect with $IC_{50}$ of $37.38{\mu}M$ compared with that of NG-monomethyl-L-arginine ($IC_{50}=90.76{\mu}M$). Moreover, Compound 2 significantly decreased secretion of cytokines such as prostaglandin $E_2$ and tumor necrosis factor-${\alpha}$. In addition, Compound 2 significantly suppressed protein expression of inducible nitric oxide synthase and cyclooxygenase-2. These results suggested that Compound 2 could be used as a valuable candidate for medicinal use or functional food, and the mechanism is warranted for further exploration.

신장 CT 검사와 99mTc-DMSA Renal Scan 검사에서 측정한 신장 길이의 차이 및 상관분석 (Discrepancy and Correlation in the renal length between Kidney CT and 99mTc-DMSA Renal scan)

  • 정우영;심동오;이동훈;최재민
    • 핵의학기술
    • /
    • 제25권1호
    • /
    • pp.15-20
    • /
    • 2021
  • 핵의학 영상 검사 중에서 99mTc-DMSA Renal scan은 비침습적이면서도 신장의 기능과 형태를 동시에 평가할 수 있으며 좌우 양측 신장에 섭취를 분석함으로써 신기능을 정량적이면서 정확하게 분석할 수 있다. 신장의 크기 및 길이 평가도 신장 이상의 주요 평가 항목이며, 99mTc-DMSA Renal scan을 이용한 신장 길이의 측정은 호흡에 의한 흔들림이나 해상력의 한계로 인해서 CT 보다 신장의 길이가 과대 또는 과소평가 될 수 있다. 본 연구는 해부학적인 평가가 우수한 CT 검사와 기능적인 평가가 우수한 99mTc-DMSA Renal scan에서 측정한 신장 길이의 차이 및 상관관계를 분석하고, 99mTc-DMSA Renal scan에서 측정한 신장 길이의 정확성을 예측하는데 그 목적이 있었다. 신장 CT 검사와 99mTc-DMSA Renal scan을 검사한 200명의 환자 자료를 대상으로 연구 분석하였고, 통계 분석을 위해 SPSS Ver. 17.0 프로그램을 사용하였다. 호흡에 의한 영향과 해상력의 차이에 의해서 CT 검사 보다 99mTc-DMSA Renal scan에서 측정한 신장의 길이가 더 큰 것으로 분석되었다. 그러나 감마카메라와 연령에 따른 신장 길의 차이는 없었으나 신장 길이를 분석한 방사선사 별로는 차이가 있었다. 따라서 신장 길이 측정에서 방법의 표준화를 통한 정량 분석 결과의 일반화는 매우 중요할 것이며, 이는 99mTc-DMSA Renal scan에서 츠정한 신장 길이의 정확성을 향상할 수 있을 것이다. 또한 CT 영상과 99mTc-DMSA Renal scan에서 측정한 신장길이는 좌우측 신장 모두 매우 강한 양(+)의 상관관계가 있었다. 다수의 신장 질환에서 신기능 변화뿐만 아니라 길이나 크기가 변화하는 경우가 많으며 신장 길이를 정확하게 측정하는 방법과 표준화는 임상적인 진단에 매우 중요할 것으로 판단된다. 특히 소아의 경우에서는 다량의 방사선 피폭이 있는 CT 검사보다 99mTc-DMSA Renal scan을 이용하여 형태학적인 평가와 기능적인 평가를 모두 시행하는 경우 많으므로 99mTc-DMSA Renal scan에서 신장에 대한 기능적인 정보뿐만 아니라 크기나 길이, 위치 등과 같은 해부학적 정보를 정확하게 제공하는 것은 더욱 중요할 것으로 판단된다.

평균역학고도장과 인공위성고도계 자료를 이용한 동해 표층해류 추산 (Estimation of the Surface Currents using Mean Dynamic Topography and Satellite Altimeter Data in the East Sea)

  • 이상현;변도성;최병주;이은일
    • 한국해양학회지:바다
    • /
    • 제14권4호
    • /
    • pp.195-204
    • /
    • 2009
  • 인공위성 고도계로 측정한 해수면 높이 자료를 사용하여 준 실시간 동해 표층해류를 추정하기 위해, 세 가지 방법으로 평균 역학지형(또는 평균 해류장)을 계산하고 각각의 특징들을 살펴보았다. 프랑스 AVISO(Archiviing, Validation and Interpretation of Satellite Oceanographic data)는 인공위성 고도계 자료와 수치모델을 이용하여 전 지구 해양에 대하여 수평적으로 $0.25^{\circ}$의 해상도를 갖는 평균 역학지형을 계산하고 지형류 방정식을 적용하여 평균 해류장을 만들어 제공하고 있다. 동해에서 장기간 관측한 수온과 염분 자료를 사용하여 500 dbar를 기준면으로 사용한 역학적 해면(steric height)을 계산하고 이를 평균 여각지형으로 환산하였다. 또한 14년 동안 동행의 표층을 이동한 표층뜰개들(ARGOS)의 궤적을 이용하여 평균 해류장을 구하였다. 인공위성 고도계로 관측한 해수면 편차와 세 가지 평균 역학지형을 합하여 절대 역학지형을 얻고, 각각의 절대 역학지형에 지형류 방정식을 적용하여 세 가지 표층해류를 추정하였다. 각 방법으로 추정된 표층해류를 2005년에 동해 남서부 해역에서 선박장착 초음파 해류계(ADCP)로 관측한 해류 자료와 정량적으로 비교하였다. 육지에서 50 km 이상 떨어진 해역에서는 인공위성 고도계로 측정한 해수면 자료에 지형류 방정식을 적용하여 구한 표층해류와 현장 관측 해류의 상관계수(R)가 0.58~0.73이며 두 자료의 제곱 평균 제곱근 편차(Root Mean Square Deviation, RMSD)는 $17.1{\sim}21.8cm\;s^{-1}$이다. 육지에서 50 km 이내의 연안에서 두자료의 R이 0.06~0.46로 상대적으로 낮고 RMSD는 $15.5{\sim}28.0cm\;s^{-1}$이다. 이처럼 연안에서는 인공위성 고도계로 관측한 해수면 높이 자료의 오차가 크므로 향후 연안에 대해서는 새로운 표층해류 추정 방법에 대한 추가 연구가 필요하다.

Spine SBRT 치료시 Coaxial MLC VMAT plan의 유용성 평가 (Evaluating efficiency of Coaxial MLC VMAT plan for spine SBRT)

  • 손상준;문준기;김대호;유숙현
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.313-320
    • /
    • 2014
  • 목 적 : Spine SBRT 치료 시 보편적인 치료방법인 콜리메이터 각도 $30^{\circ}$$330^{\circ}$를 각각 사용한 2회전 치료계획 (이하 Universal MLC VMAT)과 MLC 운동 방향과 척수 또는 마미 (이하 OAR)의 장축을 일치시킨 콜리메이터 각도 $273^{\circ}$$350^{\circ}$를 사용한 2회전 치료계획 (이하 Coaxial MLC VMAT) 유용성을 비교, 평가하고자 한다. 대상 및 방법 : 본원에서 Varian TBX을 이용하여, Coaxial MLC VMAT 치료 계획으로 치료 받은 spine SBRT환자 10명을 대상으로 하였다. 전산화치료계획은 Eclipse (ver 10.0.42, Varian, USA), PRO3 (Progressive Resolution Optimizer 10.0.28), AAA (Anisotropic Analytic Algorithm Ver 10.0.28) 알고리즘을 이용하였다. 치료계획은 VMAT로 겐트리 회전반경이 각각 $360^{\circ}$인 두 개의 ARC, 10MV FFF (Flattening Filter Free)를 이용하여 수립하였고, 각 ARC는 콜리메이터 각도 $273^{\circ}$, $350^{\circ}$로 설정하였다. 기존 치료계획을 바탕으로 실험군인 Universal MLC VMAT 치료계획을 수립하였다. 콜리메이터 각도를 제외한 모든 조건은 동일하게 설정하였으며, 특히 최적화 (VMAT optimization) 과정에서 무작위하게 나타나는 선량차이를 최소화하기 위해 각각 2회의 최적화, 선량 계산 과정을 거쳤다. 계산 grid 는 0.2 cm, normalization은 타겟 $V_{100%}=90%$로 설정하였다. OAR의 선량 $V_{10Gy}$, $D_{0.03cc}$, Dmean, 타겟의 H.I (Homogeneity index) 그리고 각 치료 계획의 Total MU를 평가 지표로 설정하였고, Mapcheck2 (Sun Nuclear Co., USA) 와 Mapphan (Sun Nuclear Co., USA) 그리고 SNC patient (Sun Nuclear Co., USA Ver 6.1.2.18513) 를 이용하여 Coaxial MLC VMAT 계획의 임상 적용 가능 여부 확인을 위한 IMRT verification QA (gamma test)를 실시하였다. 결 과 : 두 치료계획을 비교한 결과 OAR의 $V_{10Gy}$차이는 최대 4.1%, 최소 0.4%, 평균 1.9%로, $D_{0.03cc}$ 는 최대 83.5 cGy, 최소 2.2 cGy, 평균 33.3 cGy로 Coaxial MLC VMAT plan 이 더 낮은 것으로 나타났다. Dmean 또한 최대 34.8 cGy, 최소 -13.0 cGy, 평균 9.6 cGy로 Coaxial MLC VMAT plan 이 낮은 것으로 나타났다. H.I. 는 최대 0.04, 최소 0.01로 Coaxial MLC VMAT plan 이 평균 0.02 낮은 것으로 나타났으며, Total MU의 평균값을 비교한 결과 Coaxial MLC VMAT plan 이 평균 74.1 MU 더 낮게 나타났다. Coaxial MLC VMAT plan에 대한 IMRT verification gamma test 결과는 1 mm / 2%, pass rate 90.0% 기준을 모두 통과하였다. 결 론 : Coaxial MLC VMAT 치료계획은 Universal MLC VMAT 치료계획에 비해 대부분의 평가지표에서 유리한 것으로 나타냈으며 특히 OAR의 선량 $V_{10Gy}$을 낮추는데 있어 탁월한 것으로 사료된다. 실험결과를 바탕으로 두 치료 계획을 비교해 볼 때, 같은 MU를 사용한다면 Coaxial MLC VMAT 치료계획이 Universal MLC VMAT 치료계획에 비해 효율적이라 사료된다.

골반 림프선을 포함한 전립선암 치료 시 Split VMAT plan의 유용성 평가 (Evaluating efficiency of Split VMAT plan for prostate cancer radiotherapy involving pelvic lymph nodes)

  • 문준기;손상준;김대호;서석진
    • 대한방사선치료학회지
    • /
    • 제27권2호
    • /
    • pp.145-156
    • /
    • 2015
  • 목 적 : 골반 림프선을 포함한 전립선암 치료 시 기존 치료방법인 직장 전체를 윤곽 그리기한 2회전 치료계획(이하 Conventional VMAT plan)과 직장의 선량을 낮추기 위하여 상부와 하부로 나누어 윤곽 그리기한 2회전 치료계획(이하 Split VMAT plan)의 유용성을 비교, 평가하고자 한다. 대상 및 방법 : 본원에서 TrueBeam STX(Varian Medical Systems, USA)를 이용하여, Split VMAT plan으로 방사선치료를 받은 전립선암 환자 9명을 대상으로 하였다. 전산화치료계획은 Eclipse(Ver 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28), AAA(Anisotropic Analytic Algorithm Ver 10.0.28) 알고리즘을 사용하였다. 전립선 PTV의 Superior 방향으로 1 cm부터 Inferior방향으로 1 cm까지를 하부 직장으로, 전체 직장에서 직장 하부를 제외한 부분을 상부 직장으로 윤곽 그리기(Contouring) 하였다. 치료계획은 콜리메이터 각도 $30^{\circ}$, $330^{\circ}$, 겐트리 회전반경이 각각 $360^{\circ}$인 두 개의 ARC, 10MV를 이용하였다. 처방 선량은 28회에 걸쳐 동시 추가 분할 선량법(Simultaneous Integrated Boost, SIB)으로 전립선에 총 선량이 각각 63~70 Gy, 골반 림프선에 총 선량이 50.4 Gy가 되도록 하였다. Split VMAT plan을 통해 도출된 전체 직장의 $D_{mean}$를 Conventional VMAT plan에서 전체 직장의 선량용적제한 값으로 설정하여 Conventional VMAT plan을 수립하였고, 그 외에 모든 조건은 동일하게 설정하였다. 모든 치료계획은 최적화 과정에서 나타나는 선량 차이의 무작위성을 최소화하기 위하여 각각 2회의 최적화와 선량 계산 과정을 거쳤으며 전립선 PTV100% = 90% 또는 95%로 Normalize 하였다. 전체 상부 하부 직장의 평균선량, 방광의 평균선량, 상부 직장의 $V_{50%}$, 각 치료 계획의 Total MU, 그리고 PTV의 H.I.(Homogeneity Index), C.I.(Conformity Index)를 평가 지표로 설정하였고, 전자영상유도장치를 이용하여 임상 적용 가능 여부 확인을 위한 IMRT verification QA(Gamma test)를 실시하였다. 결 과 : 두 치료계획의 평균선량을 비교한 결과 전체 직장은 최대 134.4 cGy, 최소 43.5 cGy, 평균 75.6 cGy로, 하부 직장은 최대 100.5 cGy, 최소 -34.6 cGy, 평균 34.3 cGy로, 상부 직장 은 최대 1113.5 cGy, 최소 87.2 cGy, 평균 550.5 cGy로, 방광은 최대 271 cGy, 최소 -55.5 cGy, 평균 117.8 cGy로 모두 Split VMAT plan이 낮은 값을 보였다. 상부 직장의 V50%도 최대 63.4%, 최소 3.2%, 평균 23.2%로 Split VMAT plan이 낮은 것으로 나타났다. Total MU는 Split VMAT plan이 최대 148, 최소 7로, 평균 77 더 많이 사용하는 것으로 나타났다. PTV에 대한 H.I.와 C.I.는 두 치료계획 모두 서로 비슷한 결과를 나타냈다. Split VMAT plan에 대한 IMRT verification QA 결과 2 mm / 2%, Gamma pass rate 90.0% 기준을 모두 통과하였다. 결 론 : 골반 림프선을 포함한 전립선암 치료 시 Split VMAT plan은 Conventional VMAT plan과 비교하여 대부분의 평가지표에서 유리한 것으로 나타냈으며 치료효율을 높이면서 특히 상부 직장 선량을 감소시켜 전체 직장 선량을 낮추는데 탁월한 효과를 나타냈기 때문에 이를 적용시켜 방사선 치료효과를 높이는 것이 중요할 것이라 사료된다.

  • PDF

새로운 간호윤리학 방법론;통합된 사례방법론 (An integrated Method of New Casuistry and Specified Principlism as Nursing Ethics Methodology)

  • 엄영란
    • 간호행정학회지
    • /
    • 제3권1호
    • /
    • pp.51-64
    • /
    • 1997
  • The purpose of the study was to introduce an integrated approach of new Casuistry and specified principlism in resolving ethical problems and studying nursing ethics. In studying clinical ethics and nursing ethics, there is no systematic research method. While nurses often experience ethical dilemmas in practice, much of previous research on nursing ethics has focused merely on describing the existing problems. In addition, ethists presented theoretical analysis and critics rather than providing the specific problems solving strategies. There is a need in clinical situations for an integrated method which can provide the objective description for existing problem situations as well as specific problem solving methods. We inherit two distinct ways of discussing ethical issues. One of these frames these issues in terms of principles, rules, and other general ideas; the other focuses on the specific features of particular kinds of moral cases. In the first way general ethical rules relate to specific moral cases in a theoretical manner, with universal rules serving as "axioms" from which particular moral judgments are deduced as theorems. In the seconds, this relation is frankly practical. with general moral rules serving as "maxims", which can be fully understood only in terms of the paradigmatic cases that define their meaning and force. Theoretical arguments are structured in ways that free them from any dependence on the circumstances of their presentation and ensure them a validity of a kind that is not affected by the practical context of use. In formal arguments particular conclusions are deduced from("entailed by") the initial axioms or universal principles that are the apex of the argument. So the truth or certainty that attaches to those axioms flows downward to the specific instances to be "proved". In the language of formal logic, the axioms are major premises, the facts that specify the present instance are minor premises, and the conclusion to be "proved" is deduced (follows necessarily) from the initial presises. Practical arguments, by contrast, involve a wider range of factors than formal deductions and are read with an eye to their occasion of use. Instead of aiming at strict entailments, they draw on the outcomes of previous experience, carrying over the procedures used to resolve earlier problems and reapply them in new problmatic situations. Practical arguments depend for their power on how closely the present circumstances resemble those of the earlier precedent cases for which this particular type of argument was originally devised. So. in practical arguments, the truths and certitudes established in the precedent cases pass sideways, so as to provide "resolutions" of later problems. In the language of rational analysis, the facts of the present case define the gounds on which any resolution must be based; the general considerations that carried wight in similar situations provide warrants that help settle future cases. So the resolution of any problem holds good presumptively; its strengh depends on the similarities between the present case and the prededents; and its soundness can be challenged (or rebutted) in situations that are recognized ans exceptional. Jonsen & Toulmin (1988), and Jonsen (1991) introduce New Casuistry as a practical method. The oxford English Dictionary defines casuistry quite accurately as "that part of ethics which resolves cases of conscience, applying the general rules of religion and morality to particular instances in which circumstances alter cases or in which there appears to be a conflict of duties." They modified the casuistry of the medieval ages to use in clinical situations which is characterized by "the typology of cases and the analogy as an inference method". A case is the unit of analysis. The structure of case was made with interaction of situation and moral rules. The situation is what surrounds or stands around. The moral rule is the essence of case. The analogy can be objective because "the grounds, the warrants, the theoretical backing, the modal qualifiers" are identified in the cases. The specified principlism was the method that Degrazia (1992) integrated the principlism and the specification introduced by Richardson (1990). In this method, the principle is specified by adding information about limitations of the scope and restricting the range of the principle. This should be substantive qualifications. The integrated method is an combination of the New Casuistry and the specified principlism. For example, the study was "Ethical problems experienced by nurses in the care of terminally ill patients"(Um, 1994). A semi-structured in-depth interview was conducted for fifteen nurses who mainly took care of terminally ill patients. The first stage, twenty one cases were identified as relevant to the topic, and then were classified to four types of problems. For instance, one of these types was the patient's refusal of care. The second stage, the ethical problems in the case were defined, and then the case was analyzed. This was to analyze the reasons, the ethical values, and the related ethical principles in the cases. Then the interpretation was synthetically done by integration of the result of analysis and the situation. The third stage was the ordering phase of the cases, which was done according to the result of the interpretation and the common principles in the cases. The first two stages describe the methodology of new casuistry, and the final stage was for the methodology of the specified principlism. The common principles were the principle of autonomy and the principle of caring. The principle of autonomy was specified; when competent patients refused care, nurse should discontinue the care to respect for the patients' decision. The principle of caring was also specified; when the competent patients refused care, nurses should continue to provide the care in spite of the patients' refusal to preserve their life. These specification may lead the opposite behavior, which emphasizes the importance of nurse's will and intentions to make their decision in the clinical situations.

  • PDF

NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가 (Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001)

  • 김진수;이재성;이동수;정준기;이명철
    • 대한핵의학회지
    • /
    • 제38권3호
    • /
    • pp.259-267
    • /
    • 2004
  • 목적: 전신용 PET에 대한 표준 성능 평가 방법으로 NEMA NU2-2001이 확립되어 제안되었다. 따라서 새로이 설치되는 PET 스캐너뿐 아니라 기존에 사용 중인 스캐너에 대한 성능 평가가 이 표준 방법에 따라서 새로이 이루어 져야 한다. 이 연구에서는 NEMA NU2-2001 방법을 이용하여 CTI ECAT EXACT 47 PET 스캐너의 공간해상도, 민감도, 산란분획, NECR 등을 측정하였다. 대상 및 방법: 공간해상도를 평가하기 위하여 축 방향 시야의 정 가운데와 축 방향 시야 길이의 1/4을 벗어난 횡단면에 F-10을 채운 유리관(내경 1.1 mm)을 횡단면의 중심에서 1, 10 cm 떨어진 지점에 축 방향과 평행하게 위치시킨 후 PET 영상을 얻었다. 민감도를 측정하기 위하여 폴리에틸렌 및 알루미늄 관에 F-18을 채운 후 불응시간 손실이 1%를 넘지 않는 것을 확인한 후 영상을 획득하였다. 산란분획 및 최적 영상 획득 조건을 얻기 위하여 NECR을 NEMA 산란 팬텀을 이용하여 측정하였다. 결과: FBP재구성 방법(화소 크기: $0.515{\times}0.515mm^2$)으로 영상을 재 구성했을 때 스캐너의 중심에서 1cm 벗어난 지점에서 축방향, 횡축방향 공간 분해능은 0.62, 0.66 cm (FBP, 2D와 3D), 0.67, 0.69 cm (FBP, 2D와 3D)이었고 중심에서 10 cm 벗어난 지점에서 축방향, 횡축반경방향, 횡축접선방향 공간 분해능은 0.72, 0.68 mm (FBP, 2D와 3D), 0.63, 0.66 mm (FBP, 2D와 3D), 0.72, 0.66 mm (FBP, 2D와 3D)이었다. 민감도는 스캐너의 횡축방향 708.6 (2D), 2931.3 (3D) counts/sec/MBq, 횡축방향 중심에서 10cm 벗어난 지점에서 728.7 (2D), 3398.2 (3D) counts/sec/MBq 이었다. 산란 분획은 0.19 (2D), 0.49 (3D)이었고 최고 참 계수율과 NECR은 2차원 영상 획득 모드에서 40.1 kBq/mL 일 때 64.0 kcps, 40.1 kBq/mL 일 때 49.6 kcps, 3차원 영상 획득 모드에서 4.76 kBq/mL 일 때 53.7 kcps, 4.47 kBq/mL 일 때 26.4 kcps이었다. 결론: 이 실험에서 NEMA NU2-2001로 측정한 PET스캐너의 물리적 특성은 PET스캐너에 대한 객관적 평가 및 최적화 된 영상 획득과 분석에 유용할 것이다.

PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향 (The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media)

  • 안샤론;박훈희;박민수;오신현;이승재;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제13권1호
    • /
    • pp.77-81
    • /
    • 2009
  • PET/CT (Positron Emission Tomography/ Computed Tomography)의 PET은 생체의 생리, 화학적인 정보를 정량적으로 영상화할 수 있지만 해부학적인 구조를 명확히 나타내는 데에는 한계를 가지고 있어 PET에 CT를 접목시켜 해상력을 높임은 물론, CT 데이터를 감쇠보정에 이용하여 촬영시간도 단축시키고 잡음제거 측면에서도 우수함을 나타내고 있다. 또한 CT 검사 시 조영제를 사용함으로써 병변의 정확한 범위를 확인하고 정상 구조물을 구별하는데 용이하여 조영제의 사용이 증가하고 있는 추세이다. 하지만 조영제를 사용한 경우 CT 영상의 보정에 따라 PET/CT 영상에서 표준화섭취계수(Standardized Uptake Value: SUV)에 영향을 미치기 때문에 본 연구에서는 조영제 보정에 따라 표준화섭취계수(SUV)에 미치는 정도를 평가하였다. 2008년 4월에서 7월 사이에 본원에서 PET/CT검사를 시행한 환자 중 요오드 조영제에 대한 부작용이 없고 당뇨병이 없는 환자 30명을 대상으로 (남: 20, 여: 10, 연령범위: 연령범위 27세~72세, 평균나이 49.6세) 후향적 조사를 하였다. 장비는 DSTe (General Electric Healthcare, Milwaukee, MI, USA)를 사용하였다. 검사자에게 $^{18}F$-FDG 370~555 MBq를 몸무게에 따라 주사하였으며, 1시간 정도의 안정된 자세를 취한 후 검사를 시행하였다. CT촬영은 140 kV, 210 mA로 설정하였으며 CT 검사에 사용되는 조영제의 양은 환자 몸무게 1 kg당 2 cc를 주입하였다. 검사 후 최초 획득 데이터(raw data)를 이용하여 조영제 영향을 보정한 CT데이터와 보정을 하지 않은 CT데이터로 감쇠보정을 하여 영상을 얻었으며 각 영상의 간, 심장, 폐에 관심영역(Region of Interest: ROI)를 그려 SUV를 측정하여 비교하였다. SUV를 측정한 결과 조영제 보정을 한 영상의 표준화섭취계수(SUV)가 줄어듦을 알 수 있었다. 조영제에 대한 영향이 거의 없는 폐에서는 수치적인 변화가 거의 나타나지 않았으며 통계적으로도 유의하지 않았다. 비교적 혈류가 풍부한 간과 심장에서 조영제 보정으로 인한 표준화 섭취계수(SUV) 값이 수치적인 차이를 보였으나 간에서만 통계적으로 유의했다. PET/CT 검사에서 조영제의 사용으로 인하여 검사하고자 하는 부위의 대조도를 증강시켜 진단의 효율성을 높이고 있지만 이로 인하여 표준화섭취계수(SUV)의 증가가 일어난다. 따라서 조영제를 사용한 CT로 감쇠보정을 할 경우에 조영제의 영향에 대한 보정을 해주어 고해상력의 해부학적 영상뿐만 아니라 신뢰를 할 수 있는 반정량적 방법으로 진단적 가치를 더욱 높일 수 있을 것이며 다른 장기에 대해서도 추가적인 연구가 필요하다고 생각된다.

  • PDF

감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 - (The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image -)

  • 정은미;정우영;류재광;김동석
    • 핵의학기술
    • /
    • 제12권3호
    • /
    • pp.208-213
    • /
    • 2008
  • 목적 : 전신 뼈 검사는 핵의학 에서 가장 많이 수행하는 대표적인 검사로서 서울아산병원 핵의학과에서는 다양한 감마 카메라(Philips BRIGHTVIEW, PRECEDENCE, Siemens - ECAM, ECAM signature, ECAM Plus, SYMBIA T2, GE - INFINIA)를 사용하여 검사를 시행하고 있다. 그러나 각각의 감마카메라는 같은 검사를 수행할지라도 여러 요인에 의해서로 다른 민감도를 가지며, 이는 전신 뼈 검사의 추적검사에 있어 진단의 일관성을 저해하는 요인이 되기도 한다. 따라서 전신 뼈 검사 시 주사 후 검사시간, 수분섭취량, 신진 대사 정도 등의 통제 불가능한 인자들은 제외하고 최소한의 통제 할 수 있는 감마카메라 그 자체의 민감도 보정을 목적으로, 본 연구에서는 각각의 감마카메라의 민감도를 측정하여 전신 뼈검사를 추적 검사(follow-up)로 시행하였을 경우 보정할 수 있는 합리적인 보정계수 산출에 대한 연구를 하였다. 실험재료 및 방법 : 각 감마카메라의 민감도 측정은 IAEA에서 권고하는 면 선원 민감도 측정 방법에 따라 BRIGHT-VIEW, PRECEDENCE, ECAM, ECAM signature, ECAM Plus, SYMBIA T2, INFINIA의 감마카메라 7대를 분석하였다. 민감도 측정을 위한 $^{99m}Tc$ 면 선원은 전신 뼈 검사에 일반적인 계수율인 4~7 Kcps를 기준으로 제작하였다. 모든 감마카메라는 저 에너지 고 분해능용 평행다중구멍 조준기 (Low Energy High Resolution multi parallel Collimator)를 장착하였고, 15%의 Window Width, 140-keV photopeak로 설정하였다. $^{99m}Tc$ 면 선원을 조준기에 최대한 밀착시킨 후 60초, 120초 동안 계수를 측정하여 보정계수를 산출하였다. $^{99m}Tc$ 면 선원으로 산출한 보정계수를 실제 환자 전신 뼈 검사에 적용시킬 수 있는지 확인하기 위하여 27명의 환자를 대상으로 전신 뼈 검사를 수행하고 보정계수를 적용 후 비교 분석하였다. 결과 : $^{99m}Tc$ 면 선원을 이용하여 실험한 결과, 각 감마카메라의 민감도는 ECAM plus가 가장 높았으며 ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, INFINIA, PRECEDENCE 감마카메라 순으로 관찰되었다. 이를 기초로 하여 상대적으로 중간 정도의 민감도를 갖는 ECAM 감마카메라를 기준으로 보정계수를 산출했을 때 각각 1.07, 1.05, 1.03, 1.00, 0.90, 0.83, 0.72로 분석되었다. $^{99m}Tc$ 면 선원의 실험을 통해 산출한 보정계수와 전신 뼈 검사로 산출된 보정계수의 차이를 분석하였을 때 통계적으로 유의한 차이가 없었다(p<0.05). 결론 : 암환자의 골 전이 진단에 있어 전신 뼈 검사는 예민도가 높고 비침습적이며 비교적 쉽게 시행할 수 있는 장점이 있어 추적검사로 널리 이용되고 있다. 그러나 추적 검사로 전신 뼈 검사를 시행할 경우 연속적으로 동일한 감마카메라만을 사용하는 것은 여건상 불가능하며, 동일한 감마카메라를 사용한다 하더라도 시간의 경과에 따른 장비의 효율에 변화를 고려하지 않을 수 없다. 따라서 서로 다른 감마카메라를 대상으로 산출된 민감도 보정계수의 임상적 적용은 정기적으로 전신 뼈 검사를 받는 환자의 진단에 일관성을 더 해 줄 수 있을 것으로 기대된다.

  • PDF

N-13 암모니아와 양전자방출단층촬영 동적영상을 이용하여 심근혈류량을 정량화하는 새로운 방법 개발에 관한 연구 (A Refined Method for Quantification of Myocardial Blood Flow using N-13 Ammonia and Dynamic PET)

  • 김준영;이경한;김상은;최연성;주희경;김영진;김병태;최용
    • 대한핵의학회지
    • /
    • 제31권1호
    • /
    • pp.73-82
    • /
    • 1997
  • N-13 암모니아 PET 동적영상을 이용하여 심근혈류량을 측정할 때, 부분용적효과와 스필오버현상을 보정하는 새로운 방법을 고안하고, 이 방법을 이용하여 측정한 심근혈류량을 2구획모델만을 이용한 종래의 방법과 비교, 분석하여 새로운 방법에 대한 효율성과 정확성을 고찰한다. 9명의 관상동맥 환자에서 20mCi의 N-13 암모니아를 안정상태와 부하상태에서 주사한 후, PET 동적영상을 얻어 심근의 3부분(중격, 전면벽, 측면벽)과 좌심실방에 관심영역을 그려 시간-방사능곡선을 얻었다. 심근의 3부분에 대한 심근혈류량과 스필오버분획을 기하학적 관심영역 모델 개념을 2구획모델에 포함시킨 새로운 방법과 종래의 2구획모델 방법으로 각각 구하였다. 이때 관심영역의 위치에 따른 심근혈류량을 알아보기 위해서 심근 밖에서 좌심실 중심쪽으로 20개의 관심영역을 그리고, 위의 두 방법을 이용하여 심근혈류량을 구하였다. 종래의 N-13 암모니아 2구획모델과 기하학적 모델 개념을 2구획모델에 포함시킨 새로운 방법으로 모델 합치 곡선을 구하였다. 관심영역 위치 변화에 대한 심근혈류량의 값을 종래의 방법과 새로운 방법으로 구하고, 부분용적효과를 정확하게 보정하기 위하여 관심영역을 심내막쪽에 설정하였다. 총 108개의 심근관심영역에서 두 가지 방법을 이용하여 구한 심근혈류량 사이의 회귀곡선 기울기는 1.57, 상관계수는 0.88이었다. 그리고 같은 방법으로 얻어진 스필오버분획들도 선형적 상관관계(r=1.00, 기울기=0.98)가 있었다. 결론적으로 N-13 암모니아 PET 동적영상과 기하학적 모델 개념을 2구획모델에 포함시킨 새로운 방법을 이용하여 구한 심근혈류량은 종래의 방법보다 더 효율적이며 정확하게 정량화되어짐을 알 수 있었으며, 앞으로 임상환경에서 심근혈류량 정량분석연구에 유용할 것이라고 생각한다. 환자 군에 비해 유의하게 낮았다(p<0.01). 결론적으로, 흉통을 호소한 환자에서 심근관류 신티그라피상 정상인 경우에는 심장사건의 발생율이 낮음을 알 수 있었고, 특히 관동맥조영술에 관동맥병변이있는 환자와 없는 환자간에 1차 심장사건의 발생율에 유의한 차이가 없는 것을 고려하면, 심근관류 신티그라피가 정상소견을 보이는 흉통환자는 정상 관동맥조영술 소견을 보이는 환자에 준하여 치료하여도 좋을 것으로 사료되었다.리고 0.19, 0.40, 0.53, 0.61이었다. 실제 속도상수의 비 $k_3/k_4$에 대한 (BG-OCC)/OCC와 $R_A,\;R_v$간의 상관계수는 각각 0.983, 0.984, 0.999이었으며 그때의 기울기는 각각 1.76, 0.47, 1.25이었다. 결 론 : IPT 약역학은 시간이 흐름에 따라 혈류량의 변동에 비해 도파민 운반체량의 변동에 더욱 민감한 경향을 보였으며 $k_3/k_4$에 대한 (BG-OCC)/OCC, $R_A,\;R_v$의 결과간에 좋은 상관관계를 가졌다. 따라서 이러한 약역학 컴퓨터시뮬레이션이 SPECT 영상을 이용한 도파민 운반체 또는 수용체 정량분석을 최적화하는데 매우 유용할 것으로 생각된다.TEX>-CIT SPECT는 파킨슨병의 조기진단 및 진행 추적에 임상적으로 유용할 것으로 판단된다., SCC 4예, AC 1예)였으며, 11예 중 9예(81.8%)에서 방사선학적 검사결과와 Tc-99m MIBI섭취율의 변화가 일치하였다. 결론적으로, Tc-99m MIBI SPECT는 폐암병소의 국소화 및 방사선치료 효과의 판정에 어느정도 유용하리라 사료되었다.냈고 4명에서는 low CBD obstruction을 나타내었으며 후에 CBD stone, CBD carcinoma,

  • PDF