• Title/Summary/Keyword: resolution methods

Search Result 2,190, Processing Time 0.033 seconds

Evaluation of the Usefulness of Virtual Reality Equipment for Relieving Patients' Anxiety during Whole-Body Bone Scan (전신 뼈 검사 환자의 불안감 해소를 위한 가상현실 장비의 유용성 평가)

  • Kim, Hae-Rin;Kim, Jung-Yul;Lee, Seung-Jae;Baek, Song-Ee;Kim, Jin-Gu;Kim, Ga-Yoon;Nam-Koong, Hyuk;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.27-32
    • /
    • 2022
  • Purpose When performing a whole-body bone scan, many patients are experiencing psychological difficulties due to the close distance to the detector. Recently, in the medical field, there is a report that using virtual reality (VR) equipment can give pain relief to pediatric patients with weak concentration or patients receiving severe treatment through a distraction method. Therefore, in this paper, VR equipment was used to provide psychological stability to patients during nuclear medicine tests, and it is intended to evaluate whether it can be used in clinical practice. Materials and Methods As VR equipment, ALLIP Z6 VR (ALLIP, Korea) was used and the experiment was conducted after connecting to a mobile phone. The subjects were 30 patients who underwent whole-body bone examination from September 1, 2021 to September 30, 2021. After intravenous injection of 99mTc-HDP, 3 to 6 hours later, VR equipment was put on and whole body images were obtained. After the test, a survey was conducted, and a Likert scale of 5 points was used for psychological anxiety and satisfaction with VR equipment. Hypothesis verification and reliability of the survey were analyzed using SPSS Statistics 25 (IBM, Corp., Armonk, NY, USA). Results Anxiety about the existing whole-body bone test was 3.03±1.53, whereas that of anxiety after wearing VR equipment was 2.0±1.21, indicating that anxiety decreased to 34%. When regression analysis of the effect of the patient's concentration on VR equipment on anxiety about the test, the B value was 0.750 (P<0.01) and the t value was 6.181 (P<0.01). decreased and showed an influence of 75%. In addition, overall satisfaction with VR equipment was 3.76±1.28, and the intention to reuse was 66%. The Cronbach α value of the reliability coefficient of the questionnaire was 0.901. Conclusion When using VR equipment, patients' attention was dispersed, anxiety was reduced, and psychological stability was found. In the future, as VR equipment technology develops, it is thought that if the equipment can be miniaturized and the resolution of VR content images is increased, it can be used in various clinical settings if it provides more realistic stability to the patient.

Analysis of Landslide Occurrence Characteristics Based on the Root Cohesion of Vegetation and Flow Direction of Surface Runoff: A Case Study of Landslides in Jecheon-si, Chungcheongbuk-do, South Korea (식생의 뿌리 점착력과 지표유출의 흐름 조건을 고려한 산사태의 발생 특성 분석: 충청북도 제천지역의 사례를 중심으로)

  • Jae-Uk Lee;Yong-Chan Cho;Sukwoo Kim;Minseok Kim;Hyun-Joo Oh
    • Journal of Korean Society of Forest Science
    • /
    • v.112 no.4
    • /
    • pp.426-441
    • /
    • 2023
  • This study investigated the predictive accuracy of a model of landslide displacement in Jecheon-si, where a great number of landslides were triggered by heavy rain on both natural (non-clear-cut) and clear-cut slopes during August 2020. This was accomplished by applying three flow direction methods (single flow direction, SFD; multiple flow direction, MFD; infinite flow direction, IFD) and the degree of root cohesion to an infinite slope stability equation. The application assumed that the soil saturation and any changes in root cohesion occurred following the timber harvest (clear-cutting). In the study area, 830 landslide locations were identified via landslide inventory mapping from satellite images and 25 cm resolution aerial photographs. The results of the landslide modeling comparison showed the accuracy of the models that considered changes in the root cohesion following clear-cutting to be improved by 1.3% to 2.6% when compared with those not considered in the area under the receiver operating characteristics (AUROC) analysis. Furthermore, the accuracy of the models that used the MFD algorithm improved by up to 1.3% when compared with the models that used the other algorithms in the AUROC analysis. These results suggest that the discriminatory application of the root cohesion, which considers changes in the vegetation condition, and the selection of the flow direction method may influence the accuracy of landslide predictive modeling. In the future, the results of this study should be verified by examining the root cohesion and its dynamic changes according to the tree species using the field hydrological monitoring technique.

Efficient Deep Learning Approaches for Active Fire Detection Using Himawari-8 Geostationary Satellite Images (Himawari-8 정지궤도 위성 영상을 활용한 딥러닝 기반 산불 탐지의 효율적 방안 제시)

  • Sihyun Lee;Yoojin Kang;Taejun Sung;Jungho Im
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_3
    • /
    • pp.979-995
    • /
    • 2023
  • As wildfires are difficult to predict, real-time monitoring is crucial for a timely response. Geostationary satellite images are very useful for active fire detection because they can monitor a vast area with high temporal resolution (e.g., 2 min). Existing satellite-based active fire detection algorithms detect thermal outliers using threshold values based on the statistical analysis of brightness temperature. However, the difficulty in establishing suitable thresholds for such threshold-based methods hinders their ability to detect fires with low intensity and achieve generalized performance. In light of these challenges, machine learning has emerged as a potential-solution. Until now, relatively simple techniques such as random forest, Vanilla convolutional neural network (CNN), and U-net have been applied for active fire detection. Therefore, this study proposed an active fire detection algorithm using state-of-the-art (SOTA) deep learning techniques using data from the Advanced Himawari Imager and evaluated it over East Asia and Australia. The SOTA model was developed by applying EfficientNet and lion optimizer, and the results were compared with the model using the Vanilla CNN structure. EfficientNet outperformed CNN with F1-scores of 0.88 and 0.83 in East Asia and Australia, respectively. The performance was better after using weighted loss, equal sampling, and image augmentation techniques to fix data imbalance issues compared to before the techniques were used, resulting in F1-scores of 0.92 in East Asia and 0.84 in Australia. It is anticipated that timely responses facilitated by the SOTA deep learning-based approach for active fire detection will effectively mitigate the damage caused by wildfires.

Dokdo of Korea, A Chance for Peace and Co-Prosperity A Study Using Perspectives of Public Diplomacy and Negotiation Strategies (Memorial Lesson from fisherman, An Yong-bok as a Supreme Negotiator) (한국의 독도, 평화와 상생의 기회: 공공외교 및 협상 관점의 연구 (탁월한 소시민 협상가, 어부 안용복을 기리며))

  • Mi-ae Hwang
    • Journal of Public Diplomacy
    • /
    • v.2 no.2
    • /
    • pp.27-52
    • /
    • 2022
  • Objectives: The neighboring countries of South Korea and Japan in Northeast Asia have interacted in both positive and negative ways, at times as close partners and other times adversaries, throughout their long and thorny history of extensive dynamics. The controversial dispute over Dokdo is one of the most critical issues evoking harsh tensions and arguments asserting wholly opposite claims. Dokdo is a small island between two coastal states, but significant in terms of territorial, botanical, and marine resources, and thus ownership of the island has become a point of conflict accompanied by a troubled history. But why has Dokdo been a source of conflicts and how should the controversial Dokdo issue be addressed in a way that fosters positive influence and co-prosperity? Methods: This study provides comprehensive and critical insights from a wealth of previous research and strategic suggestions for the Korean government. It utilizes the three perspectives of historical documents and political context, international regulations and legal frames, and public diplomacy. Furthermore, it applies these resources to negotiation theories and strategies to propose reasonable solutions. Results: This study suggests that it is important for Korea and Japan to try to build mutual trust through more active communication and interaction in order to understand each other before attempting to create a formal resolution via negotiation. In addition to these efforts, Korea needs to be ready for the inevitable need to take decisive action in terms of negotiation, using analytic and efficient strategies. The study proposes three solutions: 1) Strong Action Strategy, 2) International Legal Strategy, and 3) Public Diplomacy Strategy. Conclusions: From the perspective of public diplomacy, the Dokdo issue needs to be converted from a symbol of conflicts between Korea and Japan into a symbol of peace and co-prosperity. In addition to promoting a positive relationship between the two states, it can also contribute to the security environment of the Northeast Asian region and global peace.

Usefulness of volumetric BMD measurement by using low dose CT image acquired on L-spine Bone SPECT/CT (L-spine Bone SPECT/CT에서 획득된 저선량 CT 영상을 이용한 용적 골밀도 결과의 유용성)

  • Hyunsoo Ko;Soonki Park;Eunhye Kim;Jongsook Choi;Wooyoung Jung;Dongyun Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.99-109
    • /
    • 2023
  • Purpose: CT scan makes up for the weak point of the nuclear medicine image having a low resolution and also were used for attenuation correction on image reconstruction. Recently, many studies try to make use of CT images additionally, one of them is to measure the bone mineral density(BMD) using Quantitative CT(QCT) software. BMD exams are performed to scan lumbar and femur with DXA(Dual-Energy X-Ray Absorptiometry) in order to diagnose bone disease such as osteopenia, osteoporosis. The purpose of this study is to identify the usefulness of QCT_BMD analyzed with low dose CT images on L-spine Bone SPECT/CT comparing with DXA_BMD. Materials and Methods: Fifty five women over 50 years old (mean 66.4 ± 9.1) who took the both examinations(L-spine Bone SPECT/CT with SIEMENS Intevo 16 and DXA scan with GE Lunar prodigy advance) within 90 days from April 2017 to July 2022, BMD, T-score and disease classification were analyzed. Three-dimensional BMD was analyzed with low dose CT images acquired on L-spine Bone SPECT/CT scan on Mindways QCT PROTM software and two-dimensional BMD was analyzed on DXA scan. Basically, Lumbar 1-4 were analyzed and the patients who has lesion or spine implants on L-spine were excluded for this study. Pearson's correlation analysis was performed in BMD and T-score, chi-square test was performed in disease classification between QCT and DXA. Results: On 55 patients, the minimum of QCT_BMD was 18.10, maximum was 166.50, average was 82.71 ± 31.5 mg/cm3. And the minimum of DXA-BMD was 0.540, maximum was 1.302, average was 0.902 ± 0.201 g/cm2, respectively. The result shows a strong statistical correlation between QCT_BMD and DXA_BMD(p<0.001, r=0.76). The minimum of QCT_T-score was -5.7, maximum was -0.1, average was -3.2 ± 1.3 and the minimum of DXA_T-score was -5.0, maximum was 1.7, average was -2.0 ± 1.3, respectively. The result shows a statistical correlation between QCT T-score and DXA T-score (p<0.001, r=0.66). On the disease classification, normal was 5, osteopenia was 25, osteoporosis was 25 in QCT and normal was 10, osteopenia was 25, osteoporosis was 20 in DXA. There was under-estimation of bone decrease relatively on DXA than QCT, but there was no significant differences statistically by chi-square test between QCT and DXA. Conclusion: Through this study, we could identify that the QCT measurement with low dose CT images QCT from L-Spine Bone SPECT/CT was reliable because of a strong statistical correlation between QCT_BMD and DXA_BMD. Bone SPECT/CT scan can provide three-dimensional information also BMD measurement with CT images. In the future, rather than various exams such as CT, BMD, Bone scan are performed, it will be possible to provide multipurpose information via only SPECT/CT scan. In addition, it will be very helpful clinically in the sense that we can provide a diagnosis of potential osteoporosis, especially in middle-aged patients.

A study on conflicts between different occupational categories of dental hygienists and nursing assistances in terms of relationships with dentist (치과의사와의 관계에서 치과위생사와 간호조무사의 직종 간 갈등 연구)

  • Moon, Hee-Jung;Kim, Young-Sun;Seong, Mi-Gyung
    • Journal of Korean Dental Hygiene Science
    • /
    • v.1 no.2
    • /
    • pp.9-19
    • /
    • 2018
  • The purpose of this study was to examine the state of conflicts among dental health care workers. A survey was conducted on 266 dental hygienists and nursing assistants who worked in dental institutions from September 12 to November 13, 2017, and SPSS(statistical package for the social science) version 20.0 was employed to analyze the collected data. The findings of the study were as follows: 1. The most common reason of the dental hygienists for turnover was working hours and heavy workload(24.6%), followed by pay (22.6%), conflicts with dentists(16.0%) and conflicts with colleagues (11.3%). The most dominant reason of the nursing assistants for turnover was pay(31.1%), followed by working hours(24.4%), heavy workload(17.8%), conflicts with dentists(15.6%) and conflicts with colleagues(8.9%). 2. The largest reason for unsuccessful communication with dentists was that heavy workload reduced the opportunity to communicate well(54.5%). The second biggest reason was that they couldn't communicate well though they had the opportunity(24.0%), and the third greatest reason was that they tended to lag behind dentists in terms of professional knowledge(16.9%). 3. The biggest reason for unsuccessful communication among the dental health care workers was that they didn't have a lot of chances to communicate well on account of heavy workload(41.0%). The second largest reason was the differences in professional knowledge(24.9%), and the third greatest reason was that they couldn't communicate well though they had the chance(23.7%). 4. The most dominant reason for conflicts with dentists was the difference in power(24.0%), followed by poor communication skills(22.1%) and a lack of mutual respect(18.1%). But the opinions of the nursing assistants were different from those of the dental hygienists, as they cited poor communication skills as the most common reason, which was followed by the difference in power and a shortage of understanding of each other's work. 5. The most common reason for conflicts among the dental health care workers was a shortage of communication and communication skills(22.9%), and the second most dominant reasons were a lack of mutual respect and poor understanding of each other's work(17.5%), followed by a lack of mutual respect(17.2%). 6. As to the ways of resolving conflicts with dentists, the most common case was making some mutual concessions to compromise (28.9%), followed by delivering opinions through the staff meeting (23.9%), resolving conflicts by candidly exchanging opinions(15.8%), avoiding each other in moderation(11.7%) and following the opinions or assertions of dentists(1.3%). 7. Concerning the conflict resolution methods among the dental health care workers, the most prevalent way was making some mutual concessions to compromise(36.4%), followed by resolving conflicts by candidly exchanging opinions(23.0%) and conveying opinions through the staff meeting(18.5%). 8. Regarding communication among the dental health care workers, the dental hygienists(3.53±.729) considered themselves to be better at communicating than the nursing assistants(3.29±.745) did(p<0.05), and the dental hygienists(3.45±.809) who thought there was respectful treatment among workers who were different in occupational categories found themselves to be better than the nursing assistants(3.21±.952) who had the same thought did(p<0.05). As a result of analyzing whether frequent job-related meetings occurred among the workers whose occupational categories were different, the dental hygienists(3.05±.975) perceived that there were more frequent meetings than the nursing assistants(2.67±.955) did (p<0.01).

Clinical Features and Associated Factors of Macrolide-Unresponsive Mycoplasma pneumonia and Efficacy Comparison Between Doxycycline, Tosufloxacin and Corticostreoid as a Second-Line Treatment (마크로라이드 불응성 마이코플라즈마 폐렴의 임상 양상 및 연관 인자와 2차 치료제로서 doxycycline, tosufloxacin 및 corticosteroid의 효능 비교)

  • Han Byeol Kang;Youngmin Ahn;Byung Wook Eun;Seungman Park
    • Pediatric Infection and Vaccine
    • /
    • v.31 no.1
    • /
    • pp.37-45
    • /
    • 2024
  • Purpose: This study aimed to examine the clinical features and determinants of macrolide-unresponsive Mycoplasma pneumoniae pneumonia (MUMP) and to assess the differences in the time to fever resolution between doxycycline (DXC), tosufloxacin (TFX) and corticosteroid (CST) as second-line treatment. Methods: We retrospectively analyzed the medical records of patients under the age of 18 who were admitted to Nowon Eulji University Hospital between July 2018 and February 2020, diagnosed with mycoplasma pneumonia. Macrolide resistance was confirmed by detecting point mutations in the 23S rRNA gene. MUMP was clinically defined by persistent fever (≥38.0℃) lasting for 72 hours or more after the initiation of macrolide treatment. In cases of MUMP, patients were treated with an addition of CST, or the initial macrolide was replaced either DXC or TFX. Results: Out of 157 cases of mycoplasma pneumonia, 83 cases (52.9%) did not respond to macrolides. Patients with MUMP exhibited significantly higher C-reactive protein (CRP) levels (3.2±3.0 vs. 2.4±2.2 mg/dL, P=0.047), more frequent lobar/segmental infiltrations or pleural effusions (56.6% vs. 27.0%, P<0.001; 6.0% vs. 0.0%, P=0.032), and a higher prevalence of 23S rRNA gene mutations (96.4% vs. 64.6%, P<0.001) when compared to those with macrolide-susceptible M. pneumoniae pneumonia. In terms of second-line treatment, 15 patients (18.1%) responded to CST, 30 (36.1%) to DXC, and 38 (45.8%) to TFX. The time to defervescence (TTD) after initiation second-line treatment was significantly shorter in the CST group compared to the DXC (10.3±12.7 vs. 19.4±17.2 hours, P=0.003) and TFX groups (10.3±12.7 vs. 25.0±20.1 hours, P=0.043), with no significant difference observed between the DXC and TFX groups (19.4±17.2 vs. 25.0±20.1 hours, P=0.262). Conclusions: High CRP levels, the presence of positive 23S rRNA gene mutation, lobar or segmental lung infiltration, and pleural effusion observed in chest X-ray findings were significant factors associated with macrolide unresponsiveness. In this study, CST demonstrated a shorter TTD compared to DXC or TFX. Further, larger-scale prospective studies are needed to determine the optimal second-line treatment for MUMP.

A study of the plan dosimetic evaluation on the rectal cancer treatment (직장암 치료 시 치료계획에 따른 선량평가 연구)

  • Jeong, Hyun Hak;An, Beom Seok;Kim, Dae Il;Lee, Yang Hoon;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.171-178
    • /
    • 2016
  • Purpose : In order to minimize the dose of femoral head as an appropriate treatment plan for rectal cancer radiation therapy, we compare and evaluate the usefulness of 3-field 3D conformal radiation therapy(below 3fCRT), which is a universal treatment method, and 5-field 3D conformal radiation therapy(below 5fCRT), and Volumetric Modulated Arc Therapy (VMAT). Materials and Methods : The 10 cases of rectal cancer that treated with 21EX were enrolled. Those cases were planned by Eclipse(Ver. 10.0.42, Varian, USA), PRO3(Progressive Resolution Optimizer 10.0.28) and AAA(Anisotropic Analytic Algorithm Ver. 10.0.28). 3fCRT and 5fCRT plan has $0^{\circ}$, $270^{\circ}$, $90^{\circ}$ and $0^{\circ}$, $95^{\circ}$, $45^{\circ}$, $315^{\circ}$, $265^{\circ}$ gantry angle, respectively. VMAT plan parameters consisted of 15MV coplanar $360^{\circ}$ 1 arac. Treatment prescription was employed delivering 54Gy to recum in 30 fractions. To minimize the dose difference that shows up randomly on optimizing, VMAT plans were optimized and calculated twice, and normalized to the target V100%=95%. The indexes of evaluation are D of Both femoral head and aceta fossa, total MU, H.I.(Homogeneity index) and C.I.(Conformity index) of the PTV. All VMAT plans were verified by gamma test with portal dosimetry using EPID. Results : D of Rt. femoral head was 53.08 Gy, 50.27 Gy, and 30.92 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. D of Rt. aceta fossa was 54.86 Gy, 52.40 Gy, 30.37 Gy, respectively, in the order of 3fCRT, 5fCRT, and VMAT treatment plan. Likewise, Lt. Femoral head showed average 53.68 Gy, 51.01 Gy and 29.23 Gy in the same order. The maximum dose of both femoral head and aceta fossa was higher in the order of 3fCRT, 5fCRT, and VMAT treatment plan. C.I. showed the lowest VMAT treatment plan with an average of 1.64, 1.48, and 0.99 in the order of 3fCRT, 5fCRT, and VMAT treatment plan. There was no significant difference on H.I. of the PTV among three plans. Total MU showed that the VMAT treatment plan used 124.4MU and 299MU more than the 3fCRT and 5fCRT treatment plan, respectively. IMRT verification gamma test results for the VMAT plan passed over 90.0% at 2mm/2%. Conclusion : In rectal cancer treatment, the VMAT plan was shown to be advantageous in most of the evaluation indexes compared to the 3D plan, and the dose of the femoral head was greatly reduced. However, because of practical limitations there may be a case where it is difficult to select a VMAT treatment plan. 5fCRT has the advantage of reducing the dose of the femoral head as compared to the existing 3fCRT, without regard to additional problems. Therefore, not only would it extend survival time but the quality of life in general, if hospitals improved radiation therapy efficiency by selecting the treatment plan in accordance with the hospital's situation.

  • PDF

Evaluation of Usefulness and Procedures for Safety of Radiopharmaceuticals in Cisternography (Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가)

  • Kim, Da-Eun;Yoo, Yeon-Wook;Choi, Ho-Yong;Kim, Yun-Cheol;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.45-49
    • /
    • 2010
  • Purpose: Several radiopharmaceuticals were used for cisternography. But recently, due to more short acquisition time, high resolution than other radiopharmaceuticals like In-111 DTPA, we were using Tc-99m DTPA in cisternography. Using of Tc-99m DTPA for intrathecal, was not officially recognised by the FDA. And there are matters of aseptic meningitis, muscular tetany, seizures by inappropriate radiopharmaceuticals handling. So, it is necessary to prevent adverse reactions while handling the radiopharmaceuticals using in cisternography. Therefore, this study aims to evaluation of usefulness and procedures for safety of radiopharmaceuticals in cisternography. Materials and Methods: Subjects were 12radioactive tracer vials using in cisternography in 2008 Dec. 16 - 2009 Dec. 30. (1) Radioactive tracer Vial test - We were measured NaPertechnetate radiation dose and volume, normal saline volume for dilution, source volume and dose activity for patient injection. And then, calculated mass of pure DTPA. (2) Bacterial endotoxin test - We performed pyrogen test using by negative/positive control vials which was added normal saline 0.2 mL and added normal saline 0.1 mL, Tc-99m DTPA 0.1 mL in test control vial. And then, reacted by digital hot plate in $37.5^{\circ}C$ for 1 hour and compared of gel-clot in each control vials. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety procedure exam sheet. Results: (1) Radioactive tracer Vial test - Mass of DTPA per dose for patient injection (mg) was 0.88 (mg) on average, and Mass of DTPA per volume for patient injection (mg) was 0.74 (mg) on average. (2) Bacterial endotoxin test - All control test vials showed negative reactions. (3) Compliance safety procedure - We were checked safety issues and wrote out a safety exam sheet in all the exams. So, there were no adverse reactions. Conclusion: We could examine easier to safety tests using by Techscan - DTPA (Mallinckrodt): CaNa3. Each test results were passed the safety tests and there are no adverse reactions. The use of Tc-99m DTPA for cisternography, always has been become an issue. Since it has occur adverse reaction while examine the cisternography using by Tc-99m DTPA, it needs to set up the 'Standard Operating procedures'.

  • PDF

The Evaluation of Reconstruction Method Using Attenuation Correction Position Shifting in 3D PET/CT (PET/CT 3D 영상에서 감쇠보정 위치 변화 방법을 이용한 영상 재구성법의 평가)

  • Hong, Gun-Chul;Park, Sun-Myung;Jung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.172-176
    • /
    • 2010
  • Purpose: The patients' moves occurred at PET/CT scan will cause the decline of correctness in results by resulting in inconsistency of Attenuation Correction (AC) and effecting on quantitative evaluation. This study has evaluated the utility of reconstruction method using AC position changing method when having inconsistency of AC depending on the position change of emission scan after transmission scan in obtaining PET/CT 3D image. Materials and Methods: We created 1 mL syringe injection space up to ${\pm}2$, 6, 10 cm toward x and y axis based on central point of polystyrene ($20{\times}20110$ cm) into GE Discovery STE16 equipment. After projection of syringe with $^{18}F$-FDG 5 kBq/mL, made an emission by changing the position and obtained the image by using AC depending on the position change. Reconstruction method is an iteration reconstruction method and is applied two times of iteration and 20 of subset, and for every emission data, decay correction depending on time pass is applied. Also, after setting ROI to the position of syringe, compared %Difference (%D) at each position to radioactivity concentrations (kBq/mL) and central point. Results: Radioactivity concentrations of central point of emission scan is 2.30 kBq/mL and is indicated as 1.95, 1.82 and 1.75 kBq/mL, relatively for +x axis, as 2.07, 1.75 and 1.65 kBq/mL for -x axis, as 2.07, 1.87 and 1.90 kBq/mL for +y axis and as 2.17, 1.85 and 1.67 kBq/mL for -y axis. Also, %D is yield as 15, 20, 23% for +x axis, as 9, 23, 28% for -x axis, as 12, 21, 20% for +y axis and as 8, 22, 29% for -y axis. When using AC position changing method, it is indicated as 2.00, 1.95 and 1.80 kBq/mL, relatively for +x axis, as 2.25, 2.15 and 1.90 kBq/mL for -x axis, as 2.07, 1.90 and 1.90 kBq/mL for +y axis, and as 2.10, 2.02, and 1.72 kBq/mL for -y axis. Also, %D is yield as 13, 15, 21% for +x axis, as 2, 6, 17% for -x axis, as 9, 17, 17% for +y axis, and as 8, 12, 25% for -y axis. Conclusion: When in inconsistency of AC, radioactivity concentrations for using AC position changing method increased average of 0.14, 0.03 kBq/mL at x, y axis and %D was improved 6.1, 4.2%. Also, it is indicated that the more far from the central point and the further position from the central point under the features that spatial resolution is lowered, the higher in lowering of radioactivity concentrations. However, since in actual clinic, attenuation degree increases more, it is considered that when in inconsistency, such tolerance will be increased. Therefore, at the lesion of the part where AC is not inconsistent, the tolerance of radioactivity concentrations will be reduced by applying AC position changing method.

  • PDF