• Title/Summary/Keyword: resolution methods

Search Result 2,198, Processing Time 0.036 seconds

A Study on the DC Resistivity Method to Image the Underground Structure Beneath River or Lake Bottom (하저 지반특성 규명을 위한 수상 전기비저항 탐사에 관한 연구)

  • Kim Jung-Ho;Yi Myeong-Jong;Song Yoonho;Choi Seong-Jun;Lee Seoung Kon;Son Jeong-Sul;Chung Seung-Hwan
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.4
    • /
    • pp.223-235
    • /
    • 2002
  • Since weak Bones or geological lineaments are likely to be eroded, there may develop weak Bones beneath rivers, and a careful evaluation of ground condition is important to construct structures passing through a river. DC resistivity method, however, has seldomly applied to the investigation of water-covered area, possibly because of difficulties in data aquisition and interpretation. The data aquisition having high quality may be the most important factor, and is more difficult than that in land survey, due to the water layer overlying the underground structure to be imaged. Through the numerical modeling and the analysis of a case history, we studied the method of resistivity survey at the water-covered area, starting from the characteristics of measured data, via data acquisition method, to the interpretation method. We unfolded our discussion according to the installed locations of electrodes, ie., floating them on the water surface, and installing them at the water bottom, because the methods of data acquisition and interpretation vary depending on the electrode location. Through this study, we could confirm that the DC resistivity method can provide fairly reasonable subsurface images. It was also shown that installing electrodes at the water bottom can give the subsurface image with much higher resolution than floating them on the water surface. Since the data acquired at the water-covered area have much lower sensitivity to the underground structure than those at the land, and can be contaminated by the higher noise, such as streaming potential, it would be very important to select the acquisition method and electrode array being able to provide the higher signal-to-noise ratio (S/N ratio) data as well as the high resolving power. Some of the modified electrode arrays can provide the data having reasonably high S/N ratio and need not to install remote electrode(s), and thus, they may be suitable to the resistivity survey at the water-covered area.

Derivation of rock parameters from Televiewer data (텔레뷰어에 의한 토목설계 매개변수의 산출)

  • Kim Jung-Yul;Kim Yoo-Sung
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 1999.08a
    • /
    • pp.137-155
    • /
    • 1999
  • Recently, Televiewer(Borehole Acoustic Scanner(Televiewer)) has come to be widely used specially for the general engineering construction design. The Televiewer tool using a focussed acoustic beam is to detect the amplitude and traveltime of each reflected acoustic signal at the wall, resulting in the amplitude- and traveltime image respectively. Fractures can be well detected, because they easily scatter the acoustic energy due to the highly narrow beam. In addition, the drilling work will rough the borehole wall so that the acoustic energy can be scattered simply due to the roughness of the wall. Thus, the amplitude level can be directed associated with the elastic properties(impedance) and the hardness of the rock as well. Meanwhile, the traveltime image provides an information about the borehole shape and can be converted to a high precision 3D caliper log(max. 288 arms). In this paper, based on the high resolution of Televiewer images, general evaluation methods are illustrated to derive very reliable rock parameters.

  • PDF

Molecular Cytogenetic Characterization of Supernumerary Marker Chromosomes by Chromosomal Microarray (염색체 마이크로어레이를 이용한 표지염색체의 분자세포유전학적 특성)

  • Bae, Mi-Hyun;Yoo, Han-Wook;Lee, Jin-Ok;Hong, Maria;Seo, Eul-Ju
    • Journal of Genetic Medicine
    • /
    • v.8 no.2
    • /
    • pp.119-124
    • /
    • 2011
  • Purpose: Supernumerary marker chromosome (SMC) could be associated with various phenotypic abnormalities based on the chromosomal origin of SMCs. The present study aimed to determine the genomic contents of SMCs using chromosomal microarray and to analyze molecular cytogenetic characterizations and clinical phenotypes in patients with SMCs. Materials and Methods: Among patients with SMCs detected in routine chromosomal analysis, SMCs originating from chromosome 15 were excluded from the present study. CGH-based oligonucleotide chromosomal microarray was performed in 4 patients. Results: The chromosomal origins of SMCs were identified in 3 patients. Case 1 had a SMC of 16.1 Mb in 1q21.1-q23.3. Case 2 showed 21 Mb gain in 19p13.11-q13.12. Case 3 had a 4.5 Mb-sized SMC rearranged from 2 regions of 2.5 Mb in 22q11.1-q11.21 and 2.0 Mb in 22q11.22-q11.23. Conclusion: Case 1 presented a wide range of phenotypic abnormalities including the phenotype of 1q21.1 duplication syndrome. In case 2, Asperger-like symptoms are apparently related to 19p12-q13.11, hearing problems and strabismus to 19p13.11 and other features to 19q13.12. Compared with cat-eye syndrome type I and 22q11.2 microduplication syndrome, anal atresia in case 3 is likely related to 22q11.1-q11.21 while other features are related to 22q11.22-q11.23. Analyzing SMCs using high-resolution chromosomal microarray can help identify specific gene contents and to offer proper genetic counseling by determining genotype-phenotype correlations.

Evaluation of Cat Brain infarction Model Using MicroPET (마이크로 PET을 이용한 고양이 뇌 경색 모델의 평가)

  • Lee, Jong-Jin;Lee, Dong-Soo;Kim, Yun-Hui;Hwang, Do-Won;Kim, Jin-Su;Lim, Sang-Moo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.528-531
    • /
    • 2004
  • Purpose: PET has some disadvantage in the imaging of small animal due to poor resolution. With the advent of microPET scanner, it is possible to image small animals. However, the image quality was not good enough as human image. Due to larger brain, cat brain imaging was superior to mouse or rat. In this study, we established the cat brain infarction model and evaluate it and its temporal charge using microPET scanner. Materials and Methods: Two adult male cats were used. Anesthesia was done with xylazine and ketamine HCl. A burr hole was made at 1cm right lateral to the bregma. Collagenase type IV 10 ${\mu}l$ was injected using 30 G needle for 5 minutes to establish the infarction model. $^{18}F$-FDG microPET (Concorde Microsystems Inc., Knoxville, TN) scans were performed 1, 11 and 32 days after the infarction. In addition, $^{18}F$-FDG PET scans were performed using human PET scanner (Gemini, Philips medical systems, CA, USA) 13 and 47 days after the infarction. Results: Two cat brain infarction models were established. The glucose metabolism of an infarction lesion improved with time. An infarction lesion was also distinguishable in the human PET scan. Conclusion: We successfully established the cat brain infarction model and evaluated the infarcted lesion and its temporal change using $^{18}F$-FDG microPET scanner.

Probabilistic Anatomical Labeling of Brain Structures Using Statistical Probabilistic Anatomical Maps (확률 뇌 지도를 이용한 뇌 영역의 위치 정보 추출)

  • Kim, Jin-Su;Lee, Dong-Soo;Lee, Byung-Il;Lee, Jae-Sung;Shin, Hee-Won;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.317-324
    • /
    • 2002
  • Purpose: The use of statistical parametric mapping (SPM) program has increased for the analysis of brain PET and SPECT images. Montreal Neurological Institute (MNI) coordinate is used in SPM program as a standard anatomical framework. While the most researchers look up Talairach atlas to report the localization of the activations detected in SPM program, there is significant disparity between MNI templates and Talairach atlas. That disparity between Talairach and MNI coordinates makes the interpretation of SPM result time consuming, subjective and inaccurate. The purpose of this study was to develop a program to provide objective anatomical information of each x-y-z position in ICBM coordinate. Materials and Methods: Program was designed to provide the anatomical information for the given x-y-z position in MNI coordinate based on the Statistical Probabilistic Anatomical Map (SPAM) images of ICBM. When x-y-z position was given to the program, names of the anatomical structures with non-zero probability and the probabilities that the given position belongs to the structures were tabulated. The program was coded using IDL and JAVA language for 4he easy transplantation to any operating system or platform. Utility of this program was shown by comparing the results of this program to those of SPM program. Preliminary validation study was peformed by applying this program to the analysis of PET brain activation study of human memory in which the anatomical information on the activated areas are previously known. Results: Real time retrieval of probabilistic information with 1 mm spatial resolution was archived using the programs. Validation study showed the relevance of this program: probability that the activated area for memory belonged to hippocampal formation was more than 80%. Conclusion: These programs will be useful for the result interpretation of the image analysis peformed on MNI coordinate, as done in SPM program.

Increase of Tc-99m RBC SPECT Sensitivity for Small Liver Hemangioma using Ordered Subset Expectation Maximization Technique (Tc-99m RBC SPECT에서 Ordered Subset Expectation Maximization 기법을 이용한 작은 간 혈관종 진단 예민도의 향상)

  • Jeon, Tae-Joo;Bong, Jung-Kyun;Kim, Hee-Joung;Kim, Myung-Jin;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.6
    • /
    • pp.344-356
    • /
    • 2002
  • Purpose: RBC blood pool SPECT has been used to diagnose focal liver lesion such as hemangioma owing to its high specificity. However, low spatial resolution is a major limitation of this modality. Recently, ordered subset expectation maximization (OSEM) has been introduced to obtain tomographic images for clinical application. We compared this new modified iterative reconstruction method, OSEM with conventional filtered back projection (FBP) in imaging of liver hemangioma. Materials and Methods: Sixty four projection data were acquired using dual head gamma camera in 28 lesions of 24 patients with cavernous hemangioma of liver and these raw data were transferred to LINUX based personal computer. After the replacement of header file as interfile, OSEM was performed under various conditions of subsets (1,2,4,8,16, and 32) and iteration numbers (1,2,4,8, and 16) to obtain the best setting for liver imaging. The best condition for imaging in our investigation was considered to be 4 iterations and 16 subsets. After then, all the images were processed by both FBP and OSEM. Three experts reviewed these images without any information. Results: According to blind review of 28 lesions, OSEM images revealed at least same or better image quality than those of FBP in nearly all cases. Although there showed no significant difference in detection of large lesions more than 3 cm, 5 lesions with 1.5 to 3 cm in diameter were detected by OSEM only. However, both techniques failed to depict 4 cases of small lesions less than 1.5 cm. Conclusion: OSEM revealed better contrast and define in depiction of liver hemangioma as well as higher sensitivity in detection of small lesions. Furthermore this reconstruction method dose not require high performance computer system or long reconstruction time, therefore OSEM is supposed to be good method that can be applied to RBC blood pool SPECT for the diagnosis of liver hemangioma.

Study on Image Quality Assessment in Whole Body Bone Scan (전신 뼈검사에서의 영상 평가 연구)

  • Kwon, Oh Jun;Hur, Jae;Lee, Han Wool;Kim, Joo Yeon;Park, Min Soo;Roo, Dong Ook;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(P<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.

  • PDF

Analytical Method Development for Determination of Silymarin by LC-MS/MS for Related Health Functional Foods (LC-MS/MS를 이용한 건강기능식품 중 실리마린 분석법 연구)

  • Oh, Mihyune;Lee, Jin Hee;Kim, Sang-A;Kim, Meehye
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.2
    • /
    • pp.124-130
    • /
    • 2018
  • The Ministry of Food and Drug Safety (MFDS) is amending its test methods for the use of health functional foods (dietary food supplement), in order to establish regulatory standards and specifications in Korea. In this regard, we continue to pursue and perform our research on the analytical method development for the items being researched and reviewed. In this study, we have developed a sensitive and selective test method that could simultaneously separate and determinate six major bioactive flavonolignans in silymarin, which are based on the use of a liquid chromatographic-tandem mass spectrometry (LC-MS/MS). The standard calibration curves presented a linearity effect with the correlation coefficient ($r^2$) > 0.999. The limits of detection (LODs) and limits of quantitation (LOQs) were in the range of $0.3{\sim}9.0{\mu}g/L$ and $0.8{\sim}27.3{\mu}g/L$, respectively. The recovery results ranged between 96.2~98.6% at 3 different concentration levels, and its relative standard deviations (RSDs) were less than 5% as noted in this study. The proposed analytical method was characterized with a noted high resolution of the individual silymarin constituents, and the assay was fully validated as well. Our research can provide a significant scientific evidence that can be useful to amend the silymarin test method for the Health Functional Food Code.

Endoscopic Carpal Tunnel Release Using Single Portal Technique (단일 입구를 이용한 내시경적 수근관 감압술)

  • Cheon Sang-Jin;Kim Hui-Taek;Suh Kuen-Tak;Suh Jeung-Tak;Yoo Chong-Il
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.159-165
    • /
    • 2000
  • Purpose : Endoscopic carpal tunnel release technique was developed and has being used to decrease postoperative morbidity and complications. The purpose of this study was to evaluate the clinical results and clinical usefulness of endoscopic carpal tunnel release using single portal technique. Methods and Materials : 18 carpal tunnel syndrome patients who were diagnosed by means of clinical symptoms, physical examination, and electrodiagnostic study had endoscopic carpal tunnel release using single portal technique with about 1 cm oblique wrist incision on 30 hands. And then they were followed-up and reviewed in the same way. Late results of operation were analysed by grading system according to patient's own assessments of relief of symptoms at the final fellow-up. The follow-up period ranged 6 to 13 months from surgery. Results : There were postoperative improvements with respect to clinical symptoms, physical examination, and electrodiagnostic study. 23 of 30 hands$(76.7\%)$ had complete resolution of symptoms. 27 hands$(90\%)$ were able to return to normal activities and work within 6 weeks, and 30 hands$(100\%)$ returned within 8 weeks. In grip strength study, 29 hands$(96.6\%)$ regained preoperative strength in 6 months. 12 of 22 hands$(55\%)$ had improvement with respect to thenar atrophy within 6 months. Late results were as follows . 23 hands$(76.7\%)$ was graded as excellent, 6 hands$(20\%)$ graded as good and 1 hand$(3.3\%)$ graded as fair, and there was no poor result. Conclusion : We think that endoscopic carpal tunnel release with single portal technique is technically safe and simple, if the surgeon takes step to stay within the safety zone based on local anatomy and selects an appropriate patient and that endoscopic carpal tunnel release does have advantages over open release. We agree that the surgeon must be prepared to perform an open technique, if technical difficulties arise, difficulty in introducing the device into the carpal tunnel is encountered, or the transverse fibers of the transverse carpal ligaments are not clearly seen.

  • PDF

The Effect of Exercise Program for Prevention of Falling on Physical Fitness, Posture and Fall Prevention Self-Efficacy for Elderly Women (넘어짐 예방 운동이 여성노인의 체력, 자세, 낙상효능감에 미치는 영향)

  • Son, Nam Jeong;Yi, Kyung Ock;An, Ju Yeun
    • 한국노년학
    • /
    • v.37 no.1
    • /
    • pp.237-250
    • /
    • 2017
  • The purpose of this study is to analyze the effects of exercise program for prevention of falling on physical fitness, posture and fall prevention self-efficacy for elderly women. 30 females above the age of 65 were subjects for this study. Over an twelve week period, 14women in the experimental group performed exercise 2 times a week for 60 minutes per session. 16women in the control group didn't participate in the exercise program. The independent variable was a exercise program for prevention of falling. Dependent variables were physical fitness, posture and fall prevention self-efficacy. Prevention of falling exercise program is consisted of an elastic band using exercise and Korean dance movement exercise. Physical fitness consisted of grip strength, upper and lower body endurance, cardiovascular endurance, flexibility, balance, coordination. The posture was measured the static posture when standing, using a high-resolution camera, body style to automatically measure the distance and angle(M-zen, Korea). Posture was measured in both the coronal and sagittal plane via reference board. Fall prevention self-efficacy was measured via questionnaire using the Korea Falls Self-Efficacy Scale (FES-K). The physical fitness, posture and fall prevention self-efficacy were measured twice with pre and post exercise, and the difference between groups with Wilcox signed rank test, and the group-specific post verification was carried out with U-validated methods (Mann Whitney U test). Statistical significance level was verified by setting the p<.05. Lower body endurance, cardiovascular endurance, flexibility, balance and coordination significantly increased in the experimental group. The control group was no significant increase in physical fitness variables. shoulder slope angle, pelvic slope angle(coronal/sagittal), leg length difference, scapular inferior angle and left/right calcaneus angle significantly decreased in the experimental group. Both the experimental group and control group were no significant increase in fall prevention self efficacy. The prevention of falling exercise program for elderly women indicated the positive changes in physical fitness(except grip strength) and posture(except upper body slope). However, there are no significant differences of falling prevention self-efficacy between the both group. Thus, the prevention of falling exercise program for the elderly has been proved that it is highly efficient on improving physical fitness and posture proofreading. However, we still need to consider supplement exercise for grip strength and upper body slope.