• 제목/요약/키워드: resistive

검색결과 1,187건 처리시간 0.041초

새로운 저항성 누전전류 측정 방법 (A New Method for Resistive Leakage Current Measurement)

  • 함승진;한송엽;고창섭
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1397-1404
    • /
    • 2007
  • It is important to measure the resistive component separately from the total leakage current at power distribution line. It is because electric disasters such as electric shock and fire are caused mainly by the resistive component of the total leakage current. In this paper, a new theory for measuring the resistive component separately from the total leakage current is suggested, and is embodied to an actual circuit using operational amplifiers, analog switch and R-C low pass filter. Through experiments for various cases containing both the resistive and capacitive leakage currents, the suggested algorithm is confirmed to be able to measure the resistive leakage current within 4.1% of error even when the capacitive leakage current is much bigger than the resistive one. The suggested method is expected to lower the total cost because it can be realized using simple and cheap devices, and implies the measuring time can be possibly reduced because the resistive leakage current is computed exactly from the signals during only a half period of power voltage.

적분기를 이용한 저항성 누전전류 작동방식 누전차단기 개발 (Development of an Earth Leakage Breaker Operating by Resistive Leakage Current using a Resetable Integrator)

  • 함승진;한송엽;고창섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.917-918
    • /
    • 2007
  • The former earth leakage breaker is operating by total leakage current which is the vector-sum of resistive leakage current and capacitive leakage current. However, the electric disaster like the electric shock and fire is caused mainly by resistive leakage current. Therefore, the earth leakage breaker is ideal when it is operating by resistive leakage current. In this paper, the theory for finding the component of resistive leakage current from total leakage current is suggested and it is embodied to actual circuit. The resistive leakage current can be found by integrating the total leakage current during half cycle of line voltage. Thus, we can simply find resistive leakage current by using OP-AMP integrators, and we can confirm that the resistive leakage current is computed exactly from total leakage current obtained by resistive leakage current and capacitive leakage current. The results that the earth leakage breaker is operating within regular interrupt time are verified when the former earth leakage breaker's controller circuit is replaced by the proposed controller circuit.

  • PDF

EMTDC Modeling Method of Resistive type Superconducting Fault Current Limiter

  • Taejeon Huh;Lee, Jaedeuk;Park, Minwon;Yu, In-Keun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.60-65
    • /
    • 2003
  • An effective modeling and simulation scheme of a resistive type Superconducting fault Current Limiter (SFCL) using PSCAD/EMTDC is proposed in this paper. In case of High Temperature Superconducting (HTS) resistive type fault current limiter current limiting is implemented by the ultra-fast transition characteristics from the superconducting (non-resistive) state to the normal (resistive) state by overstepping the critical current density. The states can generally be divided into three sub-states: the superconducting state the quench state and the recovery state respectively. In order to provide alternative application schemes of a resistive type SFCL, an effective modeling and simulation method of the SFCL is necessary. For that purpose, in this study, an actual experiment based component model is developed and applied for the simulation of the real resistive type SFCL using PSCAD/EMTDC. The proposed simulation scheme can be implemented to the grid system readily under various system conditions including sort of faults and the system capacity as well. The simulation results demonstrate the effectiveness of the proposed model and simulation scheme.

낮은 변환손실 특성의 94 GHz MHEMT MIMIC Resistive 믹서 (Low Conversion Loss 94 GHz MHEMT MIMIC Resistive Mixer)

  • 안단;이복형;임병옥;이문교;오정훈;백용현;김성찬;박정동;신동훈;박형무;박현창;김삼동;이진구
    • 대한전자공학회논문지TC
    • /
    • 제42권5호
    • /
    • pp.61-68
    • /
    • 2005
  • 본 논문에서는 낮은 변환손실 특성의 94 GHz MIMIC(Millimeter-wave Monolithic Integrated Circuit) resistive 믹서를 설계 및 제작하였다. MIMIC resistive 믹서는 $0.1{\mu}m$ InGaAs/InAlAs/GaAs Metamorphic HEMT (High Electron Mobility Transistor)를 이용하여 설계 및 제작되었다. 제작된 MHEMT는 드레인 전류 밀도 665 mA/mm, 최대 전달컨덕턴스(Gm)는 691 mS/mm를 얻었으며, RF 특성으로 fT는 189 GHz, fmax는 334 GHz의 양호한 성능을 나타내었다. 94 GHz MIMIC 믹서의 개발을 위해 MHEMT의 비선형 모델과 CPW 라이브러리를 구축하였으며, 이를 이용하여 MIMIC 믹서를 설계하였다. 설계된 믹서는 본 연구에서 개발된 MHEMT MIMIC 공정을 이용해 제작되었다. 94 GHz MIMIC resistive 믹서의 측정결과 변환손실 특성은 94 GHz에서 8.2 dB의 양호한 특성을 나타내었으며, 입력 P1 dB는 9 dBm, 출력 P1 dB는 0 dBm의 결과를 얻었다. Resistive 믹서의 LO-IF 격리도는 94.03 GHz에서 15.6 dB의 측정 결과를 얻었다. 본 논문에서 설계 및 제작된 94 GHz MIMIC resistive 믹서는 기존의 W-band 대역 resistive 믹서와 비교하여 낮은 변환손실 특성을 나타내었다.

저항성 누전전류에 의하여 동작하는 새로운 누전차단기 (The New Residual Current Protective Devices Operating by Resistive Leakage Current)

  • 함승진;한송엽;고창섭
    • 전기학회논문지
    • /
    • 제57권2호
    • /
    • pp.198-207
    • /
    • 2008
  • The conventional Residual Current Protective Devices(RCD, or earth leakage circuit breaker, ELB) operates depending on the total leakage current which is the vector-sum of resistive and capacitive components of a leakage current. However, the electric disaster such as electric shock or fire is mainly caused by the resistive component. Therefore, in this view point, the RCD is more realistic when it operates by the resistive component of the leakage current. In this paper, a new algorithm for measuring the resistive leakage current from the total leakage current is suggested, and is realized to an actual circuit. According to the suggested algorithm, the resistive component of the leakage current can be found by integrating the total leakage current over only a half cycle of the line voltage, and it is realized by using analog switches and resettable integrators. It is confirmed through experiments that the suggested algorithm detects, within maximum average error of 6.74%, the resistive leakage current from the total leakage current, and the RCD employing the suggested algorithm brakes the circuit within the regular interrupt time(30msec).

피뢰기 열화진단을 위한 저항분 누설전류의 측정장치 (Measurement Device of Resistive Leakage Current for Arrester Deterioration Diagnosis)

  • 길경석;한주섭;김정배
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권10호
    • /
    • pp.469-475
    • /
    • 2003
  • Resistive leakage current flowing ZnO blocks increases with its ages, which is an important indicator of arrester deterioration. However, a complicated circuitry is essential to measure the resistive leakage current included in the total leakage current, and the difficult handling of the measurement makes few applications to the fields. In this paper, we propose a resistive leakage current measurement device which is composed of a current detection circuit and an analysis program operated on a microprocessor. The device samples the input leakage current waveform digitally, and discriminate the zero-cross and the peak point of the waveform to analyze the current amplitude vs. phase. The capacitive leakage current is then eliminated from the total leakage current by using an algorithm to extract the resistive leakage current only. Also, the device can be operated automatically and manually to analyze the resistive leakage current even when the leakage current waveform is distorted due to various types of arrester deterioration. To estimate the performance of the device, we carried out a test on ZnO blocks and lightning arresters. From the results, it is confirmed that the device could analyze most parameters needed for the arrester diagnostics such as total leakage current. resistive leakage current, and the $3^rd$ harmonic leakage current.

저항성 수하 제어를 적용한 3상 모듈형 UPS 인버터의 비통신선 방식 병렬 운전 (Wireless Parallel Operation of a Three-phase Modular UPS Inverter using Resistive Droop Control)

  • 김선태;지준근
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1672-1681
    • /
    • 2016
  • This paper proposes a wireless parallel operation method of three-phase modular UPS inverter using resistive droop control. Furthermore, it applies a virtual resistor to droop control so that the output impedance of UPS inverter gets closer to resistive. It makes resistive droop control effective. The simulation using PSIM was performed in order to verify the validity of proposed algorithm. After consisting two-parallel system with three-phase modular UPS inverter, the experiment according to resistive load was conducted. It demonstrated the performance of current sharing and power sharing.

A $160{\times}120$ Light-Adaptive CMOS Vision Chip for Edge Detection Based on a Retinal Structure Using a Saturating Resistive Network

  • Kong, Jae-Sung;Kim, Sang-Heon;Sung, Dong-Kyu;Shin, Jang-Kyoo
    • ETRI Journal
    • /
    • 제29권1호
    • /
    • pp.59-69
    • /
    • 2007
  • We designed and fabricated a vision chip for edge detection with a $160{\times}120$ pixel array by using 0.35 ${\mu}m$ standard complementary metal-oxide-semiconductor (CMOS) technology. The designed vision chip is based on a retinal structure with a resistive network to improve the speed of operation. To improve the quality of final edge images, we applied a saturating resistive circuit to the resistive network. The light-adaptation mechanism of the edge detection circuit was quantitatively analyzed using a simple model of the saturating resistive element. To verify improvement, we compared the simulation results of the proposed circuit to the results of previous circuits.

  • PDF

Bi-2223 초전도선재의 상전도- 및 초전도-접합부 특성평가 (Characterization of resistive-and supercodncuting-joint of Bi-2223 superconductor tape)

  • 김정호;지봉기;박형상;임준형;오승진;주진호;황보훈;나완수
    • 한국전기전자재료학회논문지
    • /
    • 제13권3호
    • /
    • pp.247-253
    • /
    • 2000
  • We evaluated the electric properties of Bi-2223 jointed tapes processed by both resistive-and superconducting-joint methods. For resistive-joint. filler materials of wood metal Pb/Sn. In and silver paste were used whereas for superconductive-joint lap joint method was used. In the resistive joint tape. critical transport property(CCR) n-value and contact resistance were observed to be in the range of 10-85% 1-8,9. and 0.71x10$\^$-6/-0.13x10$\^$-6/Ω, respectively. depending on their filler materials. Specifically it is believed that the electrical properties of resistive joint tape are significantly related to the resistivity of filler materials. On the other hand the CCR of superconductin joint type was varied 55 to 85% with uniaxial pressure probably due to the irregular microstructure in the transition region.

  • PDF

콘센트용 누전감지 모듈 개발 (Development of the Leakage Current Detection Module for a Concent)

  • 한영오
    • 한국전자통신학회논문지
    • /
    • 제8권3호
    • /
    • pp.447-452
    • /
    • 2013
  • 본 연구에서는 콘센트용 누설전류 감지 및 자동차단 모듈을 개발하였다. 제안된 누설전류 검출 모듈은 저항성 누설전류 검출 칩을 사용한 콘센트용 누설전류 검출 모듈과는 차별화된, 전력 프로세서인 MSP430 MCU(Micro Controller Unit)를 이용하여 합성 누설전류에서 저항성 누설전류를 프로그램으로 분리 검출한다. 제안된 방법으로 구현된 모듈은 저항성 누설전류 5mA 이상에서 조기 검출 및 자동차단 기능이 있을 뿐만 아니라, 저항성 누설전류 검출 기능이 프로그램으로 구현되어 있어 저항성 누설전류 5mA 이하 또는 이상으로도 쉽게 조정이 가능한 장점이 있다.