• 제목/요약/키워드: resistance measurement

검색결과 1,556건 처리시간 0.029초

EIS 분석을 통한 Mg 함량에 따른 Zn-Mg 박막의 부식 특성에 관한 연구 (The Study on the Corrosion Property of the Zn-Mg Alloy Coatings with Various Mg Contents using EIS Measurement)

  • 배기태;라정현;김광배;이상율
    • 한국표면공학회지
    • /
    • 제47권6호
    • /
    • pp.330-334
    • /
    • 2014
  • In this study, the Zn-Mg alloy coatings with various Mg contents were deposited using an unbalanced magnetron sputtering process. Their surface microstructure, chemical composition, phase, and corrosion property were investigated. The microstructure of the Zn-Mg coatings changed from porous microstructure to dense one with increasing Mg contents in the coatings. As Mg contents in coatings increased, intermetallic phases such as $Mg_2Zn_{11}$ and $MgZn_2$ were detected from X-ray diffraction (XRD) results. The corrosion resistance of the Zn-Mg alloy coatings was investigated quantitatively using electrochemical impedance spectroscopy (EIS) measurement with 3.5% NaCl solution. The results of EIS measurement showed that the charge transfer resistance and the phase angle of the Zn-Mg alloy coatings were increased from $162.1{\Omega}{\cdot}cm^2$ to $558.8{\Omega}{\cdot}cm^2$ and from about $40^{\circ}$ to $60^{\circ}$ with increasing Mg contents from 5.1 wt.% to 15.5 wt.% in the coatings. These results demonstrate that the Zn-Mg coatings with increasing Mg contents showed an enhanced corrosion resistance.

A Study on Composites of Ethylene-Vinyl Acetate Copolymer and Ethylene-Propylene-Diene Rubber with Aluminum Hydroxide as a Fire Retardant

  • Lee, Yu Jun;Lee, Su Bin;Jung, Jae Young;Lee, Dam Hee;Cho, Ur Ryong
    • Elastomers and Composites
    • /
    • 제51권2호
    • /
    • pp.93-98
    • /
    • 2016
  • The composites of EVA/EPDM including aluminum trioxide (ATH) as a fire retardant were manufactured for the purpose of improving low temperature property and flame resistance in the rubbery materials. The ratio of EVA to EPDM didn't affect the flame resistance of the rubber composites. The addition of ATH resulted in increase of the flame resistance. In the evaluation of the cold resistance, the increasing EPDM content showed enhancement of cold resistance in the composites due to increasing low Tg EPDM. It was found out that tensile strengths of the composites showed a maximum value at 100 phr of ATH by reinforcing effect, but a minimum value at 200 phr of ATH owing to slippage between the flame retardant by the external stress. In the measurement of solvent resistance in tetrahydrofuran, the increasing ATH content yielded enhancement of solvent resistance by reducing swelling of the composite, and increasing EPDM content also resulted from increase of the solvent resistance by reduction of polarizability as well as increase of crosslink in the composites.

Effects of Position of Auxiliary Probe on Ground Resistance Measurement Using Fall-of-Potential Method

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • International Journal of Safety
    • /
    • 제7권2호
    • /
    • pp.1-6
    • /
    • 2008
  • In this paper, the effects of the position and the angle of the potential probes on the measurements of the ground resistance using the fall-of-potential method are described and the testing techniques for minimizing the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the relative error in the measured value of the ground resistance due to the position of the potential probe, the ground resistance was measured for the case in which the distance of the current probe was fixed at 50[m] and the distance of the potential probe was located from 10[m] to 50[m]. Also, the potential probe was located in turn at $30[^{\circ}]$, $45[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$, and $180[^{\circ}]$. As a consequence, relative error decreased with increasing distance of the potential probe and decreasing angle between the current probe and potential probe. The results could help to determine the position of the potential probe during the ground resistance measurement.

진동삼축시험을 통한 포항 지역 사질토의 액상화 저항 특성 연구 (Liquefaction Characteristic of Pohang Sand Based on Cyclic Triaxial Test)

  • 황병윤;한진태;김종관;곽태영
    • 한국지반공학회논문집
    • /
    • 제36권9호
    • /
    • pp.21-32
    • /
    • 2020
  • 본 연구에서는 포항 액상화 현상 발생 현장에서 채취한 모래를 사용하여 진동삼축시험 및 전단파 속도 측정을 수행하였으며, 시험결과를 기반으로 액상화 저항곡선을 도출하여 액상화 저항강도(CRR)를 산정하였다. 전단파 속도는 지진 발생 전 현장상태를 모사하고자 압밀 단계 종료 시점에서 측정한 값을 활용하였다. 시험을 통해 액상화 저항강도에 대한 두 가지 인자(입도분포, 상대밀도)의 영향을 확인하였으며 기존 문헌에서 제시된 타 사질토의 액상화 저항강도와의 비교를 통해 포항 모래의 액상화 저항강도를 정량적으로 평가하였다. 또한, 측정한 전단파 속도를 활용하여 실제 현장에서 사용되는 액상화 평가 곡선과의 비교를 통해 시험 결과의 신뢰성을 확인하였다.

하남IC 상수도관로 대지비저항 측정 및 분석에 따른 전기방식 시공방안 제시 (A Proposal for Construction Plan of Electric Corrosion from Measurement and Analysis for Earth Resistivity of Ha-Nam IC Water Pipe Line)

  • 신강욱;이은춘;홍성택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.355-357
    • /
    • 2000
  • Measurement used electricsal sounding(MacOHM 2115, Japan) for grounding resistance of Jung-Bu highway Ha-Nam IC about 500m. To applied measurement method is fall of potential method and analysis earth resistivity used ESII(Electrical Sounding Interactive Interpretation) program. This result propose for construction plan of electric corrosion.

  • PDF

결정질 태양전지 모듈 내부 저항의 Missmatch 분석 (The Analysis of missmatch with resistance on Si-PV module)

  • 지양근;공지현;강기환;유권종;원창섭;안형근;한득영
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.98-103
    • /
    • 2009
  • In this paper, we test the electrical resistance of flat wire in the PV module. normally solar cell has two kind of flat wire(inter connection ribbon and bus bar ribbon). we found the phenomenon that has a unbalance with resistance when we make a wiling between of string. So, we measurement the resistance of flat wire each other. and analysis of missmatch with resistance between flat wires on PV module. next to survey of IR picture on missmatch flat wire samples for analyze of missmatch with current in the wire. and we perform IR test with solar cell that has a connection with flat wire for test the effect of missmatch resistance on solar cell. Finally we perform the Dark I-V test for survey of effect by the unbalance of resistance. By the result of Dark I-V test, the series resistance of existing connection sample is large more then innovated connection sample.

  • PDF

KCS 선형의 모형시험 및 CFD 해석을 통한 Newman-Sharma 파형저항 추정법의 검토 (Review of Newman-Sharma Wave Pattern Resistance Analysis Using Experimental and Computational Model Tests of KCS)

  • 김명수;김민창;서정화;석우찬
    • 대한조선학회논문집
    • /
    • 제60권2호
    • /
    • pp.76-85
    • /
    • 2023
  • The present study aims to review the wave pattern resistance analysis method suggested by the International Towing Tank Conference. From the experimental database of a container carrier ship model, the wave pattern measurement and resistance test results are utilized. The wave pattern resistance at the design Froude number is obtained to be compared with the wave making resistance of experiments. Wave pattern resistance is lower than wave making resistance by 1978 ITTC and uniform regardless of transverse location of wave cut. The method is also applied to the wave height field by Computational Fluid Dynamics (CFD) analyses with Froude number variation. Although numerical damping suppressed waves in downstream, waves around the hull and wave pattern resistance are properly predicted.

전압변성기용 부담특성 정밀분석용 자동평가시스템의 개발 (Development of an Automatic Evaluation System for the Precision Analysis of Potential Transformer Burden Characteristics)

  • 권성원;김문석;정재갑;이성하;김명수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권10호
    • /
    • pp.457-464
    • /
    • 2005
  • Both ratio error and phase angle error in potential transformer(PT) are critically affected by used burden, connected in parallel to the secondary terminal of the PT. Thus precise measurement of burden value is very important for the evaluation of PT An automatic measurement system has been developed for the measurement of burden value and power factor of a burden. The ac voltage, current and power of the burden are measured precisely, and the burden value and power factor were calculated from these measured values. The resistance and inductance values of the tested burden are also calculated. The overall measurement uncertainties are calculated and reported with the burden value and power factor. The best measurement uncertainty for the burden measurement with the developed automatic measurement system was estimated to be 0.5 $\%$.

전기저항 측정에 의한 FRP의 파괴 예측 기능의 평가 (Evaluation of Fracture Detection Function for the FRP by Electrical Resistance Measurement)

  • 신순기;김영희;이준희
    • 한국재료학회지
    • /
    • 제12권2호
    • /
    • pp.135-139
    • /
    • 2002
  • Carbon powders (CP) and carbon fiber (CF) were introduced info glass fiber reinforced plastics (FRP) composites to obtain fracture detection function. The composites were evaluated through the relation between a load-displacement curve and an electrical resistance change curve in three point bending test. CP containing FRP (CP-FRP) has a sensitivity of electrical resistance change at much lower load level than CF containing FRP (CF-FRP). In loading-unloading tests, CP-FRP showed a large amount of residual electrical resistance which enables the estimation of loading hysteresis.

Nb_{3}$Sn 초전도 CICC의 sub-cable to sub-cable 접합 및 접합저항 측정 (Measurement of electrical resistance at the Nb_{3}$Sn CICC joint fabricated by sub-cable to sub-cable joining)

  • 이호진;홍계원;김기백;권선칠;김기만
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.89-92
    • /
    • 1999
  • A small scale joint sample of Nb3Sn CICC was fabricated by sub-cable to sub-cable joining. This joint was produced by parallel insertion of one end of each sub-cable into the sub-cable space of the other side of cable, which can decrease the equivalent electrical resistance at the joint is expected to have average properties, dc resistance and ac losses, in view of the shapes of ITER type joint and strand to strand joint. The 3.8nOhm of dc resistance was measured in the range of 10-200A transport current. The normalized resistivity of the joint was about 6.7 $\mu}$Ohm-$^mm{2}$. Considering the normalized resistivity, the full scale joint prepared by sub-cable to sub-cable joining may have similar joint dc resistance with other conventional full scale joints with a shorter joining length.

  • PDF